HomeMy WebLinkAboutSCOPE OF WORK METAL ROOFy 1. PAUL WELCH INC. Mechanical . Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com December 14, 2017 Re: Neubauer Re -Roof 1186 Nettles Blvd. Jensen Beach, FL 34957 SCOPE OF WORK: Install new Metal Roof (Extreme Metal Fabricators, LLC "5-V Crimp FL #17022.1) at above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE7-10 PROJECT DATA: BUILDING HIEGHT = 10'-0" A= 3' MEAN ROOF HIEGHT = <25' ROOF ANGLE = 4:12 SHAPE = PITCHED HIP ADJUSTMENT FACTOR = 1.00 IMPROTANCE FACTOR = 1.00 WIND VELOCITY V ult=165MPH WIND VELOCITY V asd = 128 MPH EXPOSURE = D ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF): ZONE 1' (Field) = -40.3 ZONE 2 (Perimeter/ Ridge) = -68.0 ZONE 3 (Corners) = -99.8 Paul Welch Inc. 'Paul Welch P.E. Reg. No. 29945 December 14, 2017 1186 Nettles Blvd. Jensen Beach, FL 1 of 3 METAL ROOFING ATTACHMENT REQUIREMENTS: , Metal roofing to be attached with corrosion resistant Hex -Head wood screws #10 x 1 minimum with weather sealing washers (minimum 3/16" penetration through deck). Fasteners shall be placed through the panel ribs at 12" on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING =16" O.C. ZONE 2 (Perimeter/ Ridge): FASTENER SPACING =16" O.C. ZONE 3 (Corners): FASTENER SPACING = 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ.- Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 & 2:-93.5PSF / Zone 3:-101PSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2. Underlayment shall be Approved 30# Roofing Felt. DECK INSTALLATION: Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL # 17022.1), manufacturer's specifications, and the Florida Building Code 2014. Paul Welch Inc. Paul Welch P.E. Reg: No. 29945 December 14, 2017 1186 Nettles Blvd. Jensen Beach, FL 2 of 3 pt A ntw ROOF ZONE PLAN A=3' Q Q, 0 = ZONE DESIGNATION (TYPICAL) NOTE: ZONE "3 SHOWN ONLY (DIFFERENT ATTACHMENT, ZONES I & 2 REQUIRE ATTACHMENT PER SHEET2. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 December 14,2017 1186 Nettles Blvd. Jensen. Beach, FL 3 of 3