HomeMy WebLinkAboutBUILDING CODE11/19/2017 f, -, Florida Building Code Online �
11651.12
26 Ga. 5V Crimp
26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 12 R2 265vCrimp 15-
Approved for use outside HVHZ: Yes
32Plvwood HVHZ.pdf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
Created by Independent Third Party: Yes
@ 6" o.c. fastener spacing. Install per manufacturers
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 12 R2 265vCrimp 15-
32Plywood HVHZ.pdf
Created by Independent Third Party: Yes
11651.13
26 Ga. 5V Crimp
26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 13 R2 265vCrimp 15-
Approved for use outside HVHZ: Yes
32Plvwood NonHVHZ.odf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 13 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf
Created by Independent Third Party: Yes
@ 16" o.c. fastener pattern. Install per manufacturers
Evaluation Reports
details. Not for use in HVHZ Zones.
FL11651 R2 AE 14FL11651 13 R2 265vCrimp 15-
32Plvwood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 14 R2 265vCrimp 1x4 15-
32Plvwood NonHVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 14 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c, fastener spacing. -156.5 psf
Created by Independent Third Party: Yes
@ 6" o.c. fastener spacing. Install per manufacturers
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 14 R2 265vCrimp 1x4 15-
32Plvwood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lok
26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 15 R2 26GulfLok 16 15-
32Plvwood HVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-161.OPSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Created by Independent Third Party: Yes
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
Evaluation Reports
spacing. Install per manufacturers details. For use in HVHZ
FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15-
32Plvwood HVHZ.pdf
Zones.
Created by Independent Third Party: Yes
11651.16
26 Ga. Gulf Lok
26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 16 R2 26GulfLok 16 15-
32Plvwood NonHVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 16 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-63.5PSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Created by Independent Third Party: Yes
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
Evaluation Reports
spacing. Install per manufacturers details. Not for use in
FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16 15-
32Plvwood NonHVHZ.Ddf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.17
26 Ga. GulfPBR
26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 17 R2 26GulfPBR 15-32Plvwood NonHVHZ.pdf
FL11651 R2 II 17 R2 Metal Roof Panel Detail.pdf
Approved for use outside HVHZ: Yes
Verified By: Dan Kuhn, P.E. 75519
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf
Evaluation Reports
@ 12" o.c. fastener pattern. Install per manufacturer
FL11651 R2 AE 17 R2 26GulfPBR 15-
details. Not for use in HVHZ
32Plvwood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.18
26 Ga. GulfPBR
26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use
Installation Instructions
https://floridabuilding.org/prlpr app otl.aspx?param=wGEVXQwtDgsQFc5K%2ffrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 4/5
11/19/2017
Figrida Building Code Online -
Approved for use in HVF . !s
Approved for use outside HVHZ: Yes
FL11651 R2 II 14f 351 18 R2 26GulfPBR lx4 IS -
32Plvwood HVHZ.Ddf
Impact Resistant: N/A
FL11651 R2 II 18 R2 Metal Roof Panel Detaii.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
For use in HVHZ Zones
FL11651 R2 AE 14FL11651 18 R2 26GulfPBR lx4 15-
32Plvwood HVHZ.Ddf
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
26 Ga. GulfPBR over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 19 R2 26Gu1fPBR 15-
Approved for use outside HVHZ: Yes
32Plvwood HVHZ.adf
Impact Resistant: N/A
FL11651 R2 II 19 R2 Metal Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Other: -60.5 psf @ 24" D.C. fastener spacing.-154.75 psf
Created by Independent Third Party: Yes
@ 12" o.c. fastener spacing. Install per manufacturer's
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 19 R2 26GulfPBR 15-
32Plywood HVHZ.Ddf
Created by Independent Third Party: Yes
11651.20
26 Ga. GulfPBR
26 Ga. GulfPBR over lx4 Wood Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 20 R2 26GulfPBR lx4 15-
Approved for use outside HVHZ: Yes
32Plvwood NOnHVHZ.Ddf
Impact Resistant: N/A
FL11651 R2 II 20 R2 Metal Roof Panel Detailpdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" D.C. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
Not for use in HVHZ Zones
FL11651 R2 AE 20 R2 26GulfPBR lx4 15-
32Plvwood NonHVHZ.adf
Created by Independent Third Party: Yes
Go to Page Pagel / 2
Back fdext
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
®a M22
See-Llr1tYMhTRIC
hfps://floridabuilding.org/prlpr app_dti.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgNNppMyNezj3512EBPOQwgA%3d%3d 5/5