HomeMy WebLinkAboutLETTER - SCOPE OF WORKPAUL WELCH -INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
December 14, 2017
Re: Ellington Re -Roof
10725 S. Ocean Drive Lot 55
Jensen Beach, FL 34957
SCOPE OF WORK:
Remove existing roofing and install new 5-V Crimp Metal Roof (Gulf Coast Supply &
Manufacturing FL # 11651.13) at above referenced residence address over new underlayment
and existing plywood sheathing.
DESIGN CRITERIA:
FBC 2014
,ASCE7-10
PROJECT DATA:
BUILDING HIEGHT =10'
A= 3'
MEAN ROOF HIEGHT = <15'
ROOF ANGLE = 3:12
SHAPE = PITCHED GABLE
RVIPROTANCE FACTOR =1.00
WIND VELOCITY V uit =165 MPH
WIND VELOCITY V asd =124 MPH
EXPOSURE = D
ENCLOSURE CLASS = ENCLOSED BUILDING
INTERNAL PRESSURE COEFFICIENT = -0.18
171 �-
poll Coy,
APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (nsf):
ZONE 1 (Field) = -44.7
ZONE 2 (Perimeter/ Ridge) = -75.5
ZONE 3 (Comers) = -110.8
10725 S. Ocean Drive Lot 55 Jensen Beach, FL 34957
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
December 14, 2017
/ 1 of 4
METAL ROOFING ATTACHMENT REQUIREMENTS:
Metal roofing to be attached with #9 -15 x 1 %Z" long (minimum V4" penetration through
plywood sheathing) Woodgrip screws with weather sealing'washers spacing'as follows:
ZONE 1(Field):
Fasteners through ribs (Type 1 per product approval) at 16" O.C.
ZONE -2 (Perimeter/ Ridge):
Fasteners through ribs (Type 1 per product approval) at 16" O.C.
ZONE 3 (Corners):
Fasteners adjacent to ribs both sides (Type 2 per product approval) at 16" O.C.
Zones 1 & 2 Design uplift Pressure: -94.25 psf
Zone 3 Design uplift Pressure: - 131.0 psf
Zones 1 &2: 94.25 > 75.5 > 44.7 Therefore O.K.
Zone 3: 131.0 > 110.8 Therefore O.K.
NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL
SIDELAPS FOR SLOPES LESS THAN 3:12.
UNDERLAYMENT:
Underlayment shall be Tri-Built Roofing Products FL# 16048.1 "Tri-Built S/A HT TU".
While priming is optional, TRI-BUILT recommends priming the deck if the final roof cover is
not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back
the first 3 ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as. far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while
holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal
seams _should be minimum 3-inches, configured to shed water. Vertical seams, should be 6inches
and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -
laps shall be sealed using either heat -welding or hot air welding techniques. For Valleys and
Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge
in each direction. For valleys, apply the sheet starting at the lowest point and work upward.
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
December 14, 2017
10725 S. Ocean Drive Lot 55 Jensen Beach, FL 34957 2 of 4
DECK INSTALLATION:
Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C.
perimeter and 6" O.C. field for all zones.
All work to be in compliance with product approval (FL # 11651.13), (FL#.16048.1),
manufacturer's specifications, and the Florida Building Code 2014. '
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
December 14, 2017
10725 S. Ocean Drive Lot 55 Jensen Beach, FL 34957 3 of 4
/I & 03LIr
�y
Q
Aa
li I la l IT
10
ROOF ZONE PLAN
A=3'
ZONE DESIGNATION (TYPICAE-).
NOTE: CONTINUOUS APPROVED LAP SEALANT M.USTBE USED ATALL PANEL
SIDELAPS FOR SLOPES LESS THAN 3:12.
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
December 14, 2017
10725 S. Ocean Drive Lot 55 Jensen Beach, FL 34957 4 of 4
11/19/2017 Florida Building Code OnlineFLORIDA 09FARTMIINT OF
_
r
Business ►ProfessionalRegulation
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I links I Search I
dbor
i ' Product Approval
p USER: Public User
Product Approval Menu > Product or Application Search
> Application List> Application Detail
0 OFFICE OF THE
FL #
FL11651-R2
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived 0
Product Manufacturer Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-0778
flvalidation@yahoo.com
Authorized Signature Ray Bowen
fivalidation@yahoo.com
Technical Representative
Address/Phone/Email YY�
Quality Assurance Representative
Address/Phone/Email
Category Roofing FILE
Subcategory Metal Roofing Copy
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
OO Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
Cl Validation Checklist - Hardcopy Received
Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Ena.pdf
FL11651 R2 COI Letter of Name change.pdf
Referenced Standard and Year (of Standard) Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
https://floddabuilding.orglpr/pr app_ofl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5wgNNppMyNezj3512E8POQwgAO1pad%3d 1/5
11/19/2017
Florida Buikjing Code Online
Sections from the Code _ `I/
Product Approval Method Method 1 Option D
Date Submitted
07/01/2015
Date Validated
07/10/2015
Date Pending FBC Approval
07/18/2015
Date Approved
08/18/2015
Date Revised
10/10/2017
Summary of Products
Go to Page I 1
FL # I Model, Number or Name
11651.1 0.032" Aluminum 5V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
11651.2 1 0.032" Aluminum Gulf Lok
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.OPSF
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0
psf @ 5 3/16" o.c. fastener spacing. Install per
manufacturers details. Not for use in HVHZ Zones.
11651.3 1 1" 24ga. Gulf Snap
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
11651.4 1 1" 24ga. Versal-oc
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5PSF
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
4' 0 Pagel/20 40
Description
0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 RZ II 14FL11651 1 R2 0325vCrimo 15-
32Plywood NonHVHZ.Ddf
FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 1 R2 0325vCrimD IS-
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 15-
32Plvwood NonHVHZ.pdf
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 2 R2 032Gulf-ok 16 15-
32Plywood NonHVHZ.pdf
Created by Independent Third Party: Yes
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.pdf
FL11651 R2 II 14FL11651 3 R2 1 24GuIfSnaD 17 15-
32Plvwood HVHZ..adf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 3 R2 1 24GuIfSnaD 17 15-
32Plywood HVHZ..Ddf
Created by Independent Third Party: Yes
1" Versal-oc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 4 R2 24VemaLoc SR 16.5 15-
32Plvwood HVHZ..Ddf
FL11651 R2 II 14FL11651 4 R2 Metal Roof Panel Detail..Pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR 16.5 IS-
32Plvwood HVHZ..pdf
Created by Independent Third Party: Yes
111651.5 11" Versal-oc .032" Aluminum 11" VersaLoc .032" Aluminum over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-IO1.OPSF
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6"
Installation Instructions
FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15-
32Plvwood HVHZ..pdf
FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail..Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
https:llfloridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 2/5
11/19/2017 Fl9rida Building Code Online ,--\�
o.c. clip spacing. Install pert_ iifacturers details. For use
in HVHZ Zones.
Evaluation Report:.
FL11651 R2 AE 14FPC6651 5 R2 lin 032VersaLoc SR 16 1S-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
11651.6
1.5" 24ga. Gulf Snap
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL116S1 R2 II 14FL11651 6 R2 1.5 24GulfSnao 16 15-
32Plvwood HVHZ..odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail..odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Created by Independent Third Party: Yes
o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install
Evaluation Reports
per manufacturers detals. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnao 16 15-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
11651.7
1.5" 24ga. Versal-oc
1.5" Versal-oc 24ga. 16" wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc 16 15-
32Plvwood HVHZ..pdf
FL11651 R2 II 14FL11651 7 R2 Metal Roof Panel Detail..odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @
Created by Independent Third Party: Yes
12" o.c. clip spacing. Install per manufacturers details. For
Evaluation Reports
use in HVHZ Zones.
FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 15-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
11651.8
2" 24ga. MegaLoc
24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 8 R2 24MegaLoc 18 IS -
32Plvwood NonHVHZ.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail.�df
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Created by Independent Third Party: Yes
o.c. clip spacing. Install per manufacturers details. Not for
Evaluation Reports
use in HVHZ Zones.
FL11651 R2 AE 14FL11651 8 R2 24MegaLoc 18 15-
32Pfywood NonHVHZ.pdf
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 15-
32Plywood NonHVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel Detail.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
Created by Independent Third Party: Yes
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
Evaluation Reports
fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install
FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 IS -
32Plvwood NonHVHZ.Ddf
per manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.10
24 Ga. Gulf Seam
24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins
over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 10 R2 24GulfSeam 16 1x4 IS -
32Plvwood NonHVHZ.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL116S1 R2 II 14FL11651 10 R2 Metal Roof Panel Detaii.ndf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
Created by Independent Third Party: Yes
details. Not for use in HVHZ Zones.
Evaluation Reports
FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 15-
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
11651.11
24 Ga. Gulf Seam
24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 11 R2 24GulfSeam 18 15-
32Plywood NonHVHZ.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 11 R2 Metal Roof Panel Detafl.pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Other: -69.25 psf @ 24" o.c, clip spacing. -108.5 psf @
Created by Independent Third Party: Yes
12" o.c. clip spacing. Install per manufacturers details. Not
Evaluation Reports
for use in HVHZ Zones.
FL11651 R2 AE 14FL11651 11 R2 24GulfSeam 18 15-
32Plywood NonHVHZ.odf
Created by Independent Third Party: Yes
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 3/5