HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGRECEIVED
AUG 092018 ���,✓l�
.y
y�i�•'-- F"i'
�t ����an�r Pirnlittltg; i� a r
eCES Home ;log In ! User Registration i Not Top -us } Submr Surcharge Stats & Facts Pubricatinne i FUC.Statf i' BCIS Site'Map ; Links !_ Search A7
b03d
Product Approval
';��,• USER: AyhllC User
d,.xtS
aStc^:ry n.^'
Frndu:;t.Aranlval Meru> F<tducr or Arnhcanrn Seard(> Arl aHon t€,: > Application Detail
a? Y FL z FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Ernail
08118/2017v. date reapply 06/21/17
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
ilvalidation@yahoo.com
Richard McKuhen
fivalidation@yahoo.com
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
Rchard@emfab.net
Category Roofing
Subcategory ieta Rtwfin
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
E3 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc,
Quality Assurance Contract Expiration Date 04/22/2024
Validated By zachary R. Priest, P.a.
validation Checklist - Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022. 1 5 V CRIMP Ssr )df
Referenced Standard and Year (of standard) Standard
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
yes
2003
2012
2006
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summary of Products
r
FL #
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underiayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Fl,.if04F R6 T.T 2017 09 FINAL. ER TRI-
Approved for use outside HVHZ: Yes
BUR T. LIN()r.Rf AY4i .NT �t S n04g-R6.ndP
Impact Resistant: N/A
Verified By; Robert Rierninen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of roam -on tile systems overtop the self -adhering
FLi6048_ R6 AE 2017 0% FINAL F..R I?iL
underlayment for one particular application. See ER Section
800=7 UNDERLAY,, 7'� FL16048-R6 odf
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
Beck tYext
Contact Us.:: 760.1. Glair Stone Road Tallahassee R 32399 Phone: 850•.487-1824
The State of Florida is an WEED employer. Copyright 2007-2013 Stare of Florida.:: privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the.Office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. `Pursuant to Section 455.275
(1), FloridaStatutes, effective October i, 2012, licensees licensed under chapter 455, F.S. must provide the'Deoartment with An email address If they have one. -Fite
emails provided may be used for Official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with fin email address which can be made available to Ute,public, To detemniue If you area licensee under Chapter 455, F.S.,please
tuck; here .
Product Appr—rooval AAcce�pts: El
M OR
Credit Cwd
safe
!160 SW Ponca Drive
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ ruin. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment). #9 x 1-1/2" Hex -Washer Head wood screw` to penetrate
311V min. thru deck or 5/8." embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min, thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1S07.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment sDecifications abnve
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.S PSF
-101 PSF
-228 PSF
ROW SPACING
12" o.c.
12" ®:c.
12" O.C.
FASTENER SPACING (ALONG Panel width)
1 12" o.c.
FASTENER SIZE I
#9
#10
#10
#10
Reference Data: ARCHITEcrURAL TESTING, INC. TST ID##: 1.527
UL 580-06 & 1897-041 Test Report 893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to teststandard UL 1897-12 *Design pressure margin of safety 2.1
Locke Bowden, U.
Sowden, P.E. does not have, not will acquire a financial in Ire�rm�� facturing or distributing products.
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by air cosipati ;)rnjjl5fa4turepD ortUstributing products under this
report.
r`r ��� �(� j► e 3 a d VC)
FL17022.1 5VCrNmm 24=Wide Roof Panel
~Details
1.Undorlayment to be compliance with current Florida Building Code (FBC)201761h ed.
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3.Products are compliant for State ofFlorida product approval per Rule GiG2O'8.Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
8.Support framing in compliance w/FBC 2017 VII ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside ofthis report.
Deck;
1613Z'orgreaterPlywood, or
Wood plark
__Fasteners -
4*1 .1Xwin, or
'Am win. perTable ^ for m= svuamp Roof Panel
d Design Pressures
li-ISPZOI-inhg�ralnead Wood Screws
»r
-.
Nominal 12" Nominal 12"
Fasten
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Wdth
Panel Refer to Table "A"for'Spacing Along. Panel
Overlap Length
Deck- 15/32" or greater
Plywood, or
-Mod plank