Loading...
HomeMy WebLinkAboutREVISION 4-23-19OFFICE USE ONLY: DATE FILED: 1 a3 1 REVISION FEE: LOCATION/SITE PERMIT # /. �j / 0 - U 3 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 11 DETAILED DESCRIPTION OF PROJECT i CONTRACTOR INFORMATION: STATE of FL REG./CER . #: n C,I 5101 `?jg' ST. LUCIE CO CERT. #: BUSINESS NAME: ► e 'QUALIFIERS NAME: i�Q0L.&)ICLACI ADDRESS S �` 3 CITY:Sz eA,Q { STATE: ZIP: 2�, caa (.p,9- PHONE (DAYTIME): —1 �1-1 a-- L) !l I Cl rl FAX: OWNER//B1'�BU_ILDER1I_NFORMATION: NAME: l c- l \ ADDRESS: :3-ti- CITY: STATE: ZIP: _ PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: IZ-1zl. ZIP: SLCCC: 9/23/09 FI Revised 06130/17 RLm.VISION L�.�"` gip..`.. RECEIVED APR 2 3 2019 FORM R405-2017 FLORIDA ENERGY EFI��1�`G=YP- FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NEWLAND RESIDENCE Builder Name: Street: 6513 DELEON AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: RICHARD NEWLAND Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1456.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 1176.00 ft2 b. Frame - Wood, Adjacent R=11.0 280.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1551.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1551.00 ft2 6. Conditioned floor area above grade (ft2) 1551 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(115.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 130 a. U-Factor: Sgl, U=0.45 115.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1551.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1551.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.074 Total Proposed Modified Loads: 46.56 PASS Total Baseline Loads: 48.77 I hereby certify that the plans and specifications covered by Review of the plans and O��friE ST,�l� this calculation are in compliance with the Florida Energy specifications covered by this �' a ., 0,�, Code. calculation indicates compliance with the Florida Energy Code. 411 •""'% :;; "'°::�°y��, O PRE REDPV. Before construction is completed C DATE: this building will be inspected for �j � compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. y�.. with the Florida Energy Code. y'Otj WETR� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR CODE C®MPLIANCE � 01F 8P rAeCQ rfl RY05.4.1 F BOCC FORM R405-2017 INPUT 5UMMARY CHF-GKLI5T REPUKI PROJECT Title: NEWLAND RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1551 Lot # Owner Name: RICHARD NEWLAND Total Stories: 1 Block/Subdi%ision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6513 DELEON AVENU Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL , 34951 New/Epsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1551 12408 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIVING ROOM 431 3448 No 0 1 Yes Yes Yes 2 BEDROOM 180 1440 No 0 1 1 Yes Yes Yes 3 CLST 24 192 No 0 1 Yes Yes Yes 4 BATH 72 576 No 0 1 Yes Yes Yes 5 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 6 M CLST 20 160 No 0 1 Yes Yes Yes 7 M BATH 92 736 No 0 1 Yes Yes Yes 8 HALL 36 288 No 0 1 No Yes Yes 9 KITCHEN 180 1440 Yes 0 1 No Yes Yes 10 LAUNDRY 105 840 No 0 1 Yes Yes Yes 11 FOYER 187 1496 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio LIVING ROOM 60 ft 0 431 ft2 — 1 0 0 2 Slab -On -Grade Edge Insulatio BEDROOM 27 ft 0 180 ft2 — 1 0 0 3 Slab -On -Grade Edge Insulatio CLST 2ft 0 24 ft2 — 1 0 0 4 Slab -On -Grade Edge Insulatio BATH 2ft 0 72 ft2 — 1 0 0 5 Slab -On -Grade Edge Insulatio MASTER BEDRO 30 ft 0 224 ft2 — 1 0 0 6 Slab -On -Grade Edge Insulatio M CLST 2ft 0 20 ft2 1 0 0 4/17/2019 12:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPURT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio M BATH 6 ft 0 92 ft2 — 1 0 0 8 Slab -On -Grade Edge Insulatio HALL 1 ft 0 36 ft2 — 1 0 0 9 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 180 ft2 — 1 0 0 10SIab-On-Grade Edge Insulatio LAUNDRY 7 ft 0 105 ft2 — 1 0 0 11Slab-On-Grade Edge Insulatio FOYER 11 ft 0 187 ft2 — 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1680 ft2 0 ft2 Medium 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1551 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) LIVING ROOM 20 Blown 431 ft2 0.1 Wood 2 Under Attic (Unvented) BEDROOM 20 Blown 180 ft2 0.1 Wood 3 Under Attic (Unvented) CLST 20 Blown 24 ft2 0.1 Wood 4 Under Attic (Unvented) BATH 20 Blown 72 ft2 0.1 Wood 5 Under Attic (Unvented) MASTER BEDRO 20 Blown 224 ft2 0.1 Wood 6 Under Attic (Unvented) M CLST 20 Blown 20 ft2 0.1 Wood 7 Under Attic (Unvented) M BATH 20 Blown 92 ft2 0.1 Wood 8 Under Attic (Unvented) HALL 20 Blown 36 ft2 0.1 Wood 9 Under Attic (Unvented) KITCHEN 20 Blown 180 ft2 0.1 Wood 10 Under Attic (Unvented) LAUNDRY 20 Blown 105 ft2 0.1 Wood 11 Under Attic (Unvented) FOYER 20 Blown 187 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Ext InddVING ROO 5 13 0 8 0 104.0 ft2 0 0 0.8 0 2 S Exterior Concrete Block - Ext InddVING ROO 5 13 0 8 0 104.0 ft2 0 0 0.8 0 3 W Exterior Concrete Block - Ext InddVING ROO 5 34 0 8 0 272.0 ft2 0 0 0.8 0 4 S Exterior Concrete Block - Ext Ins(HEDROOM 5 15 0 8 0 120.0 ft2 0 0 0.8 0 5 W Exterior Concrete Block - Ext InsiIHEDROOM 5 12 0 8 0 96.0 ft2 0 0 0.8 0 6 W Exterior Concrete Block - Ext Insul CLST 5 2 0 8 0 16.0 ft2 0 0 0.8 0 7 W Exterior Concrete Block - Ext Insul BATH 5 2 0 8 0 16.0 ft2 0 0 0.8 0 8 E Exterior Concrete Block - Ext IndMASTER BE 5 16 0 8 0 128.0 ft2 0 0 0.8 0 4/17/2019 12:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 9 S Exterior Concrete Block - Ext In4dASTER BE 5 14 0 8 0 112.0 ft2 0 0 0.8 0 10 E Exterior Concrete Block - Ext InsulM CLST 5 2 0 8 0 16.0 ft2 0 0 0.8 0 11 E Exterior Concrete Block - Ext InsulM BATH 5 6 0 8 0 48.0 ft2 0 0 0.8 0 12 N Exterior Concrete Block - Ext Insd1AUNDRY 5 7 0 8 0 56.0 ft2 0 0 0.8 0 13 E Exterior Concrete Block - Ext Insul FOYER 5 11 0 8 0 88.0 ft2 0 0 0.8 0 14 N Garage Frame - Wood FOYER 11 21 8 168.0 ft2 0 0.25 0.600000 0 15 E Garage Frame - Wood LAUNDRY 11 14 8 112.0 ft2 0 0.25 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Vinyl Low-E Single Yes 0.46 0.25 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 3 Vinyl Low-E Single Yes 0.45 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 3 S 4 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 4 E 8 Vinyl Law-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft4 in None None 5 E 13 Vinyl Low-E Single Yes 0.45 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 294 ft2 294 ft2 35 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1447.6 79.47 149.46 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heatt None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 4/17/2019 12:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply --- -- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 130 ft2 Attic 13 ft2 Default Leakage LAUNDRY (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Feb Mar Apr Ma Jun Jul Au Se Oct [ ]Nov Dec Jan H Feb Heating H Mar 1XXI Apr I I May Jun f 1 Jul ri Au41 ri SeP Oct [X] IXi Nov Dec 1XI Ventin Jan Feb Mar [X Apr May Jun [ Jul Aug [ Se Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/s .ft. ft2 ft 0.3 FOYER Name: Rating Compant: 4/17/2019 12:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: NEWLAND RESIDENCE Builder Name: Street: 6513 DELEON AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Y U Owner: RICHARD NEWLAND Jurisdiction: ST LUCIE COUNTY W 2 Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ljil)ing and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Oates and walls or ceilings. a. in addition, inspection of jog watts shall oe in accortlance with the provisions of ]CC-400. 4/17/201912:58 PM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 24.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1551 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.450 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 17.0 c) Area 7c. 115.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 6513 DELEON AVENUE City/FL Zip: FORT PIERCE, FL 34951 4/17/2019 12:68:46 PM EnergyGaugeB USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 ® Date: APRIL 17, 2019 Project Summary +�- wrightsoft Enure House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS(m' 40L.COM For: NEWLAND RESIDENCE 6513 DELEON AVENUE, FORT PIERCE, FL 34951 Notes: Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 14719 Btuh Ducts 3355 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 18074 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heating Cooling Area (ft� 1551 1551 Volume (ft3) 12408 12408 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 79 41 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.2 kW 17645 Btuh 20 OF 800 cfm 0.044 cfm/Btuh 1.00 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17162 Btuh Ducts 858 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier n 0.95 Equipment sensible load 17119 Btuh Latent Cooling Equipment Load Sizing Structure 2928 Btuh Ducts 1288 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4216 Btuh Equipment Total Load (Sen+Lat) 21334 Btuh Req. total capacity at 0.70 SHR 2.0 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1624AJlNA Coil RH1T2417STANJA AHRI ref 7940891 Efficiency 13.0 EER, 16 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 1- wrightsoft- 2019-Apr-1712:54:16 Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1 % ...ets\Wrightsoft WAC\NEWLAND RES- DELEON AVE.rup Calc = MJ8 Front Door faces: E wrightsoft• Right-M Worksheet Job: Entire House Date: APRIL 17, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Ergrosed wall Room height Room dimensions Room area Entire House 147.0 ft 8.0 ft 1551.0 ftz LIVING ROOM 60.0 ft 8.0 ft heat/cool 1.0 x 431.0 ft 431.0 ftz Ty Construction number U-value (Btuh/ft' °F) Or HTM (Btuh/ft2) Area (ftz or perimeter (ft) Load (Btuh) Area (ftz or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 yW � W W . W W--G C F__ _13A Sops _� 13A 5ocs 2 glazing, clr low-e 11D0 _ 13A-5ocs 2 glazing, clrlow-e 2.glazing,_clr low_e 13A-5ocs 2 glaz nq, clr Igw-e 16A-30ad 22 tph _a _ 0.125 0.125 0.450 0.390 0.125 0.450 0.450 0.125 0.450 _ 0 032 1_358 :n a a e__ s s __s_ w w �. _ - :__ 3.50. 3.50 12.60 . 10.92 i 3.50 12.60 , 12.6Q 3.50 12.60 �0,90. - 38.02, _,.__f:0 1.91 24.15 f 10.34 1.91 11.99 -11.99 1.91 29.42 224 _ 0.00 a1.60 280 30 ___ 20 336 15 ._41. 400 _30 1551, _ 1551 ___160 230 2 20 560 804 378 _ _ _223 981 189 _51.4 1295 _ 378 � 1390 . 5590 ,_ 306 439 724 _ _ __211 536 180 489 708 883 _ ._3474 0 _ 104 0 0 �_ 0 104 0 __ 41 272 30 =_ "'439 431 104 0 0 0 63 0 ___41 242 _ 2 431 60 __`_364 0 0 0 ' 221 0 _514 847 378 __3_86 2281 _ __ 199 0 0 0 _ _ 280 15 4.1 121 0 ______489. 463 883 .____0 370 2 1551, _ 147 6 c) AED excursion 0 200 Envelope loss/gain 12300 7950 4992 3320 12 a) Infiltration b) Room ventilation 2418 0 682 0 987 0 278 0 13 Internal gains: Occupants @ 230 Appliances/other 1 230 8300 0 0 1900 Subtotal (lines 6 to 13) 14719 17162 5979 5498 14 151 Less extemal load Less transfer Redistribution Subtotal uct loads 23% 5% 0 0 0 14719 3355 0 0 0 17162 858 23% 5% 0 0 0 5979 1363 0 0 0 5498 275 Total room load Air required (cfm) 18074 8001 18020 800 _ 7 7342 325 5773 256 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. wrigFrrtsoftw -- .4 A Right -Suite® Universal 2018 18.0.31 RSUD8101 2019-Apr-1712:54:16 Page 1 et'\Wrightsoft HVAC\NEWLAND RES- DELEON AVE.rup Calc = MJ8 Front Door faces: E wrightsofr Right-JO Worksheet Job: Entire House Date: APRIL 17, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)qosed wall Room height Room dimensions Room area BEDROOM 27.0 ft 8.0 ft heat/cool 12.0 x 15.0 ft 180.0 ft2 CLST 2.0 ft 8.0 ft heaticool 2.0 x 12.0 ft 24.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft� Area (ft5 or perimeter (ft) Load (Btuh) Area (ft5 or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool - 6 11 - -- 1N W -- --- 13A Socs_. _ 13A 5ocs 2 glazing, clr low-e 11D0---- ----_ 13A-5ocs 2 glazing, clr low-e 2 glazing,_olr low e-,_. 13A-5ocs 2 plazinm clr low=e _ _16A 30aad - 0.125 0.125 0.450 ._ 0.390 0.125 0.450 -- 0._450 0.125 0.450 --_0.032 1.358 -�- n_ a a ey s a __s__ w w --- _ 3.50. 3.50 12.60 10;92 3.50 12.60 -__12.e0 3.50 12.60 _ 0.9Q _38.02 - - -1.91. 1.91 24.15 10.34 1.91 11.99 - 11.99 1.91 29.42 -2.24 -_0.00 - -::::---0 0 0 - _ 0 0 0 0 - - ---_-0.--- 0 0 ------ __0 0 0 0 --- -- --_-0 0 0 0 -- - -0 0 0 -_ 0 0 0 _._0 16 0 ___24 2 - --- ---- - - 0 0 0 _ W . -0 0 0 _�_ ._ _0 56 _ 0 -� _22 76 - - -----9 0 0 --.__._ 0 0 0 _�-_. _ 0 31 ___ -_ Q __54- 0 _-- _ W WL-G1 _C - ____0 120 15 0 96 0 _ 966 15 - 0 96 0 -ry-0 368 189 0 336 0 _ 201 180 -� �0 184 0 _ 0 0 0 16 0 ..�_ 180 180 180 27 __ _-_ 161 _ 1027 _ _ 403 0 _�24 24 ^� - 6 c)AED exursion -62 -3 Envelope loss/gain 2080 905 154 82 12 a) Infiltration b) Room ventilation 444 0 125 01 33 0 9 0 13 Internal gains: Occupants @ 230 Appliances/other 1 230 800 0 0 0 Subtotal (lines 6 to 13) 2525 2060 186 91 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 5% 0 0 97 2621 598 0 0 54 2114 106 23% 5% 0 0 -186 0 0 0 0 -91 0 0 Total room load Air required (cfm) 3219 142 2220 99 T0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �'�- wrYgF�tsoft® Right -Suite® Universal 2018 18.0.31 RSU08101 2019-Apr-17 12:e 16 ACC"' 9 ACC"'...ets\Wrightsoft HVAC\NEWLAND RES- DELEON AVE.rup Calc = MJ8 Front Door faces: E Page 2 wrightsoft' Right-M Worksheet Job: Entire House Date: APRIL 17, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 2.0 ft 8.0 ft heat/cool 6.0 x 12.0 ft 72.0 ftz MASTER BEDROOM 30.0 ft 8.0 ft heat/cool 16.0 x 14.0 ft 224.0 ftz Ty Construction number U-value (Btuh/ft;-°F) Or HTM (Btuh/ft� Area (ft5 or perimeter (ft) Load (Btuh) Area (ftz or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W WI _ W IW L-G C F 13A=5ocs_ 13A-5ocs 2 glazing, clr low-e 11D0 _ 13A 5ocs �' u 2 glazing, clr low-e 2,glazing, clr low-er � 13A-5ocs 2 alazinq, clr low-e 16A 30ad ----0.- 22A-tPh __i 0,125 0.125 0.450 _ 0.390 - 0.125 0,450 _0,450 0.125 0.450 n_ a a a s s ._s_ w w T 3 50_�1.91. 3.50 12.60 10.92 3.50 12.60 _ 12.6Q 3.50 12.60 ____0.90. , 38.02 1.91 24.15 10.34 ' 1.91 11.99 _- 11 99 1.91 _29.42 �2.24 0.00 ��_�, 0 V 0 0 0 _ __0 =0 396 189 0 392 0 ___ _ 0. 0 0 216 362 0 214 0 ._ 0_ 0 __ __ 0 _ �502 0_ 0 0 0 �_ 0 0 _ -___D 16 0 ,,. -72 72 0 0 0 0 0 0 0 0 _.- _ 0 0 0 0 0 _-___ 0 0 _ -_0 31 0 128 15 0 _ ___� 112 0 _T__0 0 0--- 0 113 1 0 - 112 0 _ 0 0 0 _0 16 0---0 _-`72 _2 _0 56 _ 032 1.58 65 76 _ _ 161 ._0 -- -„ 224 -224 30 -201_ _224 1141_ 6 c) AED excursion -18 6 Envelope loss/gain 197 174 2318 1300 12 a) Infiltration b) Room ventilation 33 0 9 0 494 0 139 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 400 0 0 900 Subtotal Qines 6 to 13) 229 584 2811 2339 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 1 23% 5% 0 0 100 330 75 0 0 62 646 32 23% 5%1 0 0 88 2899 661 0 0 49 2388 119 Total room load Air required (cfm) 405 18 678 30 356D 158 2507 111 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -ria- 2019-Apr-17 12:54:16 .4LCP. Right -Suite® Universal 2018 18.0.31 RSU08101 Page 3 ...ets\Wrightsoft HVAC\NEWLAND RES- DELEON AVE.rup Calc = 1VIJ8 Front Door faces: E - wrightsoft Right-M Worksheet Job: Entire House Date: APRIL 17, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area M CLST 2.0 ft 8.0 ft heat/cool 2.0 x 10.0 ft 20.0 ftz M BATH 6.0 ft 8.0 ft heat/cool 1.0 x 920 ft 92.0 ftz Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft� Area (ft5 or perimeter (ft) Load (Btuh) Area (ftz or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W - W I--G -13A_5ocs_ __ 13A-5ocs 2 glazing, clr low-e 11DO 13A-5ocs 2 glazing, clr low-e 2.gl-ing,_Gr-low e_ 13A-5ocs 2.Alazinp, Gr low�e 16A730ad .�_ 0125 0.125 0.450 0 390 0.125 0.450 0.450 0.125 0.450 _--0.032 1 358 _n_ a a e__ s s —s_ w w z_ _; ^3.50 3.50 12.60 10.92 3.50 12.60 12.60. 3.50 _ 12_60 0.90_ 38.02, �_1:91 1.91 24.15 _, 10_34 1.91 11.99 _11.99 1.91 29.42 _ _224 0 00 _ � 0 16 0 0 -= 0 56 0 .__-_ p e_ — _.0 168 0 0 0 __`_0 0 0 _ _82 228 92 0 - 0 0 __0, 0 0 _206. 0 __ 16 0 0 31 0 V�Q 48 0 _0 48 0 �p W _ 0 0 :"-__0 0 __ 0__._ _ 20 _ 20 0 0 __0 0 0_____ _-20 ____2 0, 0 „_ _ ' __0 0 0 18 76 0 0 0 0 ___ 0 45 0 0 ,_0 0 0 _� 92 92 0 0 0 W 0 0 _ 92 6 0 , 6 c)AED excursion -2 -21 Envelope loss/gain 150 73 479 277 12 a) Infiltration b) Room ventilation 33 0 9 0 99 0 28 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 400 Subtotal (lines 6 to 13) 183 82 577 704 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 5% 0 0 -183 0 0 0 0 -82 0 0 23% 5% 0 0 109 686 156 0 0 67 772 39 Total room load Air required (cfm) 0 0 0 01 843 37 810 36 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -0� wrYgFZtsoFt® .�CCIi Right -Suite® Universal 2018 18.0.31 RSU08101 2019-Apr-17 1 Page 4 ...ets 9 \Wrightsoft HVAC\NEWLAND RES- DELEON AVE.rup Calc = MJ8 Front Door faces: E -�- wrightsoft• Right-JO Worksheet Job: Entire House Date: APRIL 17, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name E)qposed wall Room height Room dimensions Room area HALL O ft 8.0 ft heattcool 12.0 x 3.0 ft 36.0 ft2 KITCHEN O ft 8.0 ft heat/cool 15.0 x 120 ft 180.0 ftz Ty Construction number U-value (Btuh/ft' °F) Or HTM (Btuhlft� Area (ftl or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 613k5oCs. 11 ___0 0 0 _0 . -__ 0 0 _____-_0 0 0 : 0 0 0 0 _-__._ 0 0 _0 0 0 __._0 0 0 0 ' 0. 0 0 ____� 0 0 0 __0 0 __ _0 0 0 ___,_ 0 0 0 ____0_ 0 0 w W _ Ih�. �-G..2.glazmg, W (5:-- F _ _-_ 13A-5ocs 2 glazing, clr low-e 11D0 11D 5ocs 2 glazing, clr low-e clr_low=e__ 13A 5ocs 2 glazinq, clr low-e ! 16Q-30ad 22&-tph_ —_0.125 0.125 0.450 0.390 0.3 0.450 _______0.450 0.125 _ 0.450 -_n_ a a a s s -_s- w w _ 3.SQ 3.50 12.60 _10_92 3.50 12.60, __ _ 126Q 3.50 12.60 0. =90;:� _— 1.91 1.91 24.15 — 10.34 1.3 11.99 - 11.99 1.91 29.42 :i 24 Y _ 0 0 0 _ �..0 T __ 0 0 _0 _ .—.—_0 0 0 ___ 0 _- 0 0 -_0 �______0 0 0 __ 0 _ _0 0 �__ 0 0 0 T 0 v 36 0 _ 0 36 `_0 0 0 _0 0 0 0.032 .- _ _- 32 0 =- 81 0 _ ___1 180 =- 480 180 0 —� _0- __ _ 161. 0 - ____463 0 6 c) AED excursion -2 -76 Envelope loss/gain 32 781 1 161 327 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 2200 Subtotal (lines 6 to 13) 32 78 161 2527 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 5% 0 0 -32 0 0 0 0 -78 0 0 23% 5% 0 0 5 166 38 0 0 11 2538 127 Total room load Air required (cfm) 0 01 0 0 1 19 204 2665 118 Calculations approved byACCA to meet all requirements of Manual J 8th Ed - wr➢gFVtsoTt- 2019-Apr-17 12:54:16 A Right -Suite® Universal 2018 18.0.31 RSUD8101 Page 5 ...ets\Wrightsoft HVAC\NEWLAND RES- DELEON AVE.rup Cale = MJ8 Front Door faces: E -�- wrightsofr Right-JO Worksheet Job: Entire House Date: APRIL 17, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area LAUNDRY 7.0 ft 8.0 ft heat/cool 15.0 x 7.0 ft 105.0 ftz FOYER 11.0 ft 8.0 ft heat/cool 11.0 x 17.0 ft 187.0 ft' Ty Construction number U-value (Btuh/ft' °F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 _VC W _13A-5ocs 13A 5ocs 2 glazing, clr low-e 11D0 13A-5ocs glazing, clr low-e .2,glazing, clrlow,e-^ 2 13A5ocs plazinq, clr low-e 16A-30ad 22A-tph ___ _ 0.125 0.125 0.450 0,390 0.125 0.450 0.450 0.125 0_450 _`0.032 —n _ a a -_ e _ s s —s, w w . _ = 3.,50- 3.50 12.60 _10,92 3.50 12.60 , 12.6Q 3.50 ^ 12.60 —0.90, 1.91' 1.91 24.15 10_34 1.91 11.99 �11.99 1.91 29.42 _Z24 56 0 0 ,_i - - 0 0 0 0 0 ___—_- 0 0 0 0 88 15 -- 20 0 0 —__0 0 _ _ 0 _1187 53 1 -_— 20 0 0 _ 0 0 _ 0 ___1.87 184 189 __—__._22I- 0 0 0. 0 _—_ 0 ----168 101 362 ___i211 0 0 ----.--0 0 _ _0 _-419- 0 0 0 0 0 0 T _ W k2 ; _ 0 0 0 __—_-, 0 0 -_-0 0 _ 0 -_ 105 IWI � - G -C___ F ` 0 _ 0 _— 105 0 ^ ^_ 0 —_--94 0 0 _235 6 c) AED excursion -26 5 Envelope loss/gain 556 317 1182 1098 12 a) Infiltration b) Room ventilation 115 0 32 0 181 0 51 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 500 0 0 1200 Subtotal (lines 6 to 13) 671 849 1363 2349 14 15 Less e)demal load Less transfer Redistribution Subtotal Duct loads 23% 5% 0 0 0 671 153 0 0 0 849 42 23% 5% 0 0 3 1366 311 0 0 8 2357 118 Total room load Air required (cfm) 824 36 892 40 1678 74 2475 110 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgF%tsofF!- C Right -Suite® Universal 2018 18.0.31 RSU08101 2019 Apr-17 1 Page 6 9 .4CCP� ...etslWrightsoft HVAC\NEWLAND RES- DELEON AVE.rup Calc = MJ8 Front Door faces: E Page 6 Duct System Summary Job. wrightsoft® Date: APRIL 17, 2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For. NEWLAND RESIDENCE - 6513 DELEON AVENUE, FORT PIERCE, FL34951 Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm 178 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mad Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 678 18 30 1.000 5.0 Ox0 VIFx 35.1 135.0 st2 BEDROOM h 3219 142 99 1.000 7.0 Ox 0 VIFx 41.5 135.0 st2 FOYER c 2475 74 110 1.000 7.0 Ox0 VIFx 19.1 95.0 KITCHEN c 2665 9 118 1.000 7.0 Ox 0 VIFx 26.3 115.0 st1 LAUNDRY c 892 36 40 1.000 5.0 Ox 0 VIFx 19.1 115.0 st1 LIVING ROOM h 3671 162 128 1.000 7.0 Ox0 VIFx 23.7 115.0 st1 LIVING ROOM -A h 3671 162 128 1.000 7.0 Ox 0 VIFx 22.9 115.0 st1 M BATH h 843 37 36 1.000 5.0 Ox0 VIFx 40.6 135.0 st2 MASTER BEDROOM h 3560 158 111 1.000 7.0 Ox0 VIFx 42.9 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 355 276 1.000 804 9.0 0 x 0 VinlFlx st1 st1 Peak AVF 726 690 1.000 924 12.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 800 800 0 0 0 0 Ox 0 VIFx wrightsoft" 2019-Apr-17 12:54:16 A ••^ •�� �•-��� Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1 ..ets\Wrightsoft HVAC\NEWLAND RES- DELEON AVE.rup Cale = MJ8 Front Door faces: E