Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residen@l _ n@eod Project Name: RYAN & ANGELA DOYLE Builder Name: -- . " 1-1 Street: BALD CYPRESS TRAIL Permit Office: ST. LUCIE COU City, State, Zip: FT. PIERCE, FL, Permit Number: • ................ Owner: RYAN & ANGELA DOYLE Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2096.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=9.0 2096.90 ftz b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (2886.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2798.00 ftz 6. Conditioned floor area above grade (ftz) 2742 b. Roof Deck (Unvented) R=20.0 88.00 ft2 Conditioned floor area below grade (ftz) 0 C. N R= ftz 11. Ducctt s � R ftz 7. Windows(333.6 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: MUD ROOM 6 425 a. U-Factor: Dbl, U=0.31 189.60 ftz SHGC: SHGC=0.28 b. U-Factor: Dbl, U=0.33 96.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 48.5 SEER:16.00 c. U-Factor: Dbl, U=0.33 48.00 ftz SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A - ftz a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 7.947 ft. Area Weighted Average SHGC: 0.258 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2742.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2742.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits CF, Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 69.67 PASS Total Baseline Loads: 84.55 I hereby certify that the plans and specifications covered by Review of the plans and 4TjIE S�,q�, this calculation are-inare-in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPAR BY- Before construction is completed DATE: - this building will be inspected for y IJ compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. with OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. it He Copy 12/13/2017 11:11 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: RYAN & ANGELA DOYLE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2742 Lot # Owner: RYAN & ANGELA DOYLE Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: BALD CYPRESS TRAI Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2742 27420 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BATH 3 70 700 No 0 1 No Yes Yes 2 BEDROOM 3 169 1690 No 2 1 1 No Yes Yes 3 BEDROOM 2 156 1560 No 2 1 1 No Yes Yes 4 BATH 2 70 700 No 0 1 No Yes Yes 5 OFFICE 168 1680 No 0 1 No Yes Yes 6 MUD ROOM 88 880 No 0 1 No Yes Yes 7 PANTRY 55 550 No 0 1 No Yes Yes 8 LAUNDRY 92 920 No 0 1 No Yes Yes 9 HALL 151 1510 No 0 1 No Yes Yes 10 KITCHEN 252 2520 Yes 2 1 No Yes Yes 11 DINING 153 1530 No 0 1 No Yes Yes 12 GREAT ROOM 477 4770 No 4 1 No Yes Yes 13 FOYER 180 1800 No 0 1 No Yes Yes 14 WIC 2 49 490 No 0 1 No Yes Yes 15 M BATH 189 1890 No 0 1 No Yes Yes 16 WIC 96 960 No 0 1 No Yes Yes 17 MASTER BEDROO 288 2880 No 2 1 1 No Yes Yes 18 TLT. 39 390 No 0 1 No Yes Yes 12/13/2017 11:11 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BATH 3 17 ft 0 70 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 -_-_ 0 1 0 3 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 156 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio BATH 2 7 ft 0 70 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio OFFICE 13 ft 0 168 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio MUD ROOM 1 ft 0 88 ft2 __-- 0 1 0 7SIab-On-Grade Edge Insulatio PANTRY 1 ft 0 55 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio LAUNDRY 11 ft 0 92 ft2 ____ 0. 1 0 9Slab-On-Grade Edge Insulatio HALL 1 ft 0 151 ft2 -___ 0 1 0 10SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 252 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulatio DINING 26 ft 0 153 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio GREAT ROOM 22 ft 0 477 ft2 __-- 0 1 0 13SIab-On-Grade Edge Insulatio FOYER 12 ft 0 180 ft2 ____ 0 1 0 14SIab-On-Grade Edge Insulatio WIC 2 1 ft 0 49 ft2 ____ 0 1 0 15SIab-On-Grade Edge Insulatio M BATH 22 ft 0 189 ft2 _-__ 0 1 0 16SIab-On-Grade Edge Insulatio WIC 12 ft 0 96 ft2 ---- 0 1 0 17SIab-On-Grade Edge Insulatio MASTER BEDRO 31 ft 0 288 ft2 ____ 0 1 0 18SIab-On-Grade Edge Insulatio TLT. 13 ft 0 39 ft2 ____ 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt .Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2890 ft2 0 ft2 Light 0.6 No 0.9 No 20 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2742 ft2 N N 12/13/2017 11:11 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BATH 3 20 Blown 70 ft2 0.1 Wood 2 Under Attic (Unvented) BEDROOM 3 20 Blown 169 ft2 0.1 Wood 3 Under Attic (Unvented) BEDROOM 2 20 Blown 156 ft2 0.1 Wood 4 Under Attic (Unvented) BATH 2 20 Blown 70 ft2 0.1 Wood 5 Under Attic (Unvented) OFFICE 20 Blown 168 ft2 0.1 Wood 6 Under Attic (Unvented) MUD ROOM 19 Blown 88 ft2 0.1 Wood 7 Under Attic (Unvented) PANTRY 20 Blown 55 ft2 0.1 Wood 8 Under Attic (Unvented) LAUNDRY 20 Blown 92 ft2 0.1 Wood 9 Under Attic (Unvented) HALL 20 Blown 151 ft2 0.1 Wood 10 Under Attic (Unvented) KITCHEN 20 Blown 303 ft2 0 Wood 11 Under Attic (Unvented) DINING 20 Blown 153 ft2 0.1 Wood 12 Under Attic (Unvented) GREAT ROOM 20 Blown 15 ft2 0.1 Wood 13 Under Attic (Unvented) GREAT ROOM 20 Blown 555 ft2 0 Wood 14 Under Attic (Unvented) FOYER 20 Blown 180 ft2 0.1 Wood 15 Under Attic (Unvented) WIC 2 20 Blown 49 ft2 0.1 Wood 16 Under Attic (Unvented) M BATH 20 Blown 189 ft2 0.1 Wood 17 Under Attic (Unvented) WIC 20 Blown 96 ft2 0.1 Wood 18 Under Attic (Unvented) MASTER BEDRO 20 Blown 288 ft2 0.1 Wood 19 Under Attic (Unvented) TLT. 20 Blown 39 ft2 0.1 Wood WALLS Adjacent Cavity Space Width Height n Areale Sheathing Framing Solar AhqnrFt Belo w 1 S Exterior Concrete Block - Int Insul BATH 3 9 7 0 10 0 70.0 ft2 0 0 0.5 0 2 W Exterior Concrete Block - Int Insul BATH 3 9 10 0 10 0 100.0 ft2 0 0 0.5 0 3 S Exterior Concrete Block - Int InsBIEDROOM 3 9 13 0 10 0 130.0 ft2 0 0 0.5 0 4 S Exterior Concrete Block - Int InsBEDROOM 2 9 12 0 10 0 120.0 ft2 0 0 0.5 0 5 S Exterior Concrete Block - Int Insul BATH 2 9 7 0 10 0 70.0 ft2 0 0 0.5 0 6 S Exterior Concrete Block - Int Insul OFFICE 9 13 0 10 0 130.0 ft2 0 0 0.5 0 7 N Exterior Concrete Block - Int InsuLAUNDRY 9 6 0 10 0 60.0 ft2 0 0 0.5 0 8 E Exterior Concrete Block - Int InsuLAUNDRY 9 5 0 10 0 50.0 ft2 0 0 0.5 0 9 N Exterior Concrete Block - Int Insul DINING 9 11 0 10 0 110.0 ft2 0 0 0.5 0 _ 10 W Exterior Concrete Block - Int Insul DINING 9 15 0 10 0 150.0 ft2 0 0 0.5 0 11 W Exterior Concrete Block - Int InsGREAT ROO 9 17 10 12 4 219.9 ft2 0 0 0.5 0 12 E Exterior Concrete Block - Int Insul FOYER 9 12 0 10 0 120.0 ft2 0 0 0.5 0 13 N Exterior Concrete Block - Int Insul M BATH 9 6 0 10 0 60.0 ft2 0 0 0.5 0 14 E Exterior Concrete Block - Int Insul M BATH 9 12 0 10 0 120.0 ft2 0 0 0.5 0 15 S Exterior Concrete Block - Int Insul M BATH 9 4 0 10 0 40.0 ft2 0 0 0.5 0 16 N Exterior Concrete Block- Int Insul WIC 9 12 0 10 0 120.0 ft2 0 0 0.5 0 17 N Exterior Concrete Block - Int InsMASTER BE 9 16 0 10 0 160.0 ft2 0 0 0.5 0 18 W Exterior Concrete Block - Int InsUASTER BE 9 15 0 10 0 150.0 ft2 0 0 0.5 0 19 N Exterior Concrete Block - Int Insul TLT. 9 6 0 9 0 54.0 ft2 0 0 0.5 0 _20 E Exterior Concrete Block - Int Insul TLT. 9 7 0 9 0 63.0 ft2 0 0 0.5 0 12/13/2017 11:11 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated DINING None .4 2 8 8 21.3 ft2 2 E Insulated FOYER None .4 3 6 8 20 ft2 WINDOWS J Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 3 Vinyl Low-E Double Yes 0.31 0.28 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 S 4 Vinyl Low-E Double Yes 0.31 0.28 15.0 ft2 2 ft 0 in 1 ft 4 in None None 3 S 5 Vinyl Low-E Double Yes 0.31 0.28 9.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 6 Vinyl Low-E Double Yes 0.31 0.28 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 8 Vinyl Low-E Double Yes 0.31 0.28 15.0 ft2 6 ft 0 in 1 ft 4 in None None 6 N 9 Vinyl Low-E Double Yes 0.31 0.28 30.0 ft2 12 ft 0 in 1 ft 4 in None None 7 W 10 Vinyl Low-E Double Yes 0.31 0.28 30.0 ft2 2 ft 0 in 1 ft 4 in None None 8 W 11 Vinyl Low-E Double Yes 0.33 0.24 96.0 ft2 12 ft 0 in 1 ft 4 in None None 9 E 12 Vinyl Low-E Double Yes 0.31 0.28 13.6 ft2 12 ft 0 in 1 ft 4 in None None 10 N 13 Vinyl Low-E Double Yes 0.31 0.28 15.0 ft2 2 ft 0 in 1 ft 4 in None None 11 E 14 Vinyl Low-E Double Yes 0.31 0.28 6.0 ft2 6 ft 0 in 1 ft 4 in None None 12 N 17 Vinyl Low-E Double Yes 0.31 0.28 20.0 ft2 2 ft 0 in 1 ft 4 in None None 13 W 18 Vinyl Low-E Double Yes 0.33 0.21 48.0 ft2 12 ft 0 in 1 ft 4 in None None 14 E 20 Vinyl Low-E Double Yes 0.31 0.28 6.0 ft2 6 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall- Insulation 1 624 ft2 624 ft2 24 ft loft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 3199 175.62 330.28 .3247 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 48.5 kBtu/hr cfm 0.7 1 sys#1 12/13/2017 11:11 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply -- ---- Return ---- Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 425 ft2 Attic 105 ft2 Default Leakage MUD ROO (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr Ma [X] Jun [X] Jul [X] Aug Se [ ] Oct Nov Dec HeatinHJan f X� Feb 'Mar f Aprf j May ] Jun ] Jul ] Aug Sep [ ] Oct Nov H HDec Ventin Jan [ Feb X Mar [ A r [ Ma ]Jun ] Jul E E E j Au Se [Xj Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/13/2017 11:11 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 82 The lower the EnergyPerformance Index, the more efficient the home. BALD CYPRESS TRAIL, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=9.0 2096.90 ftZ b. N/A R= ftZ 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2798.00 ftz 6. Conditioned floor area (ftZ) 2742 b. Roof Deck (Unvented) R=20.0 88.00 ftz 7. Windows- Description Area c. N/A R= ftZ a. U-Factor: Dbl, U=0.31 189.60 ftZ 11. Ducts a. Sup: Attic, Ret: Attic, AH: MUD ROOM R ftZ 6 425 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=0.33 96.00 ftZ SHGC: SHGC=0.24 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.33 48.00 ftZ a. Central Unit 48.5 SEER:16.00 SHGC: SHGC=0.21 d. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 7.947 ft. Area Weighted Average SHGC: 0.258 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2742.00 ftZ a. Electric EF: 0.95 b. N/A R= ftZ c. N/A R= ftZ b. Conservation features None 15. Credits CF, Pstat -1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed -based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.. 12/13/2017 11:11 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RYAN & ANGELA DOYLE Builder Name: Street: BALD CYPRESS TRAIL Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: RYAN & ANGELA DOYLE Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/13/2017 11:11 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 9 Pro ect Summary Job: wri htsoft � Summary Date: Dec 13, 2017 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM --Proiect Information For: RYAN & ANGELA DOYLE BALD CYPRESS TRAIL, FT. PIERCE,FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design. Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF . Heating.Summary Structure 20658 Btuh Ducts 7775 Btuh Central vent (162 cfm) 4998 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 33431 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 - Heating cooling Area (ft2 2742 2541 Volume (ft3) 29096 29096 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 155 78 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 174,408 Btuh O 1617 cfm 0.057 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 20793 'Btuh Ducts 6737 Btuh Central vent (162 cfm) 2677 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 28697 Btuh Latent Cooling Equipment Load Sizing Structure 5641 Btuh Ducts 3983 Btuh Central vent (162 cfm) 6785 Btuh Outside air Equipment latent load 16409 Btuh Equipment total load 45106 Btuh Req. total capacity at 0.70 SHR 3.4 ton Cooling Equipment Summary Make Trane Trade TRAN E Cond 4TTR7048A1 Coil TEM6AOD48H41++TDR AHRI ref 7947779 Efficiency 13.0 EER, 16 SEER Sensible cooling 33950 Btuh Latent cooling 14550 Btuh Total cooling 48500 Btuh Actual air flow 1617 cfm Air flow factor 0.059 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.65 julle Copy Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. u 2017-Dec-13 11:22:42 wrightsoft® Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ACCA ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N -�- wrightsoft` Right-M Worksheet Job: Entire House Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BATH 3 2 Exposed wall 211.0 ft 17.0 ft 3 Room height 10.6 ft d 10.0 ft heat/cool 4 Room dimensions 10.0 x 7.0 ft 5 Room area 2742.0 ft2 70.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ftJ Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 XE Tailored foam inject 0.000 n 0.00 0.00 564 499 0 0 0 __ 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 20 0 174 210 0 0 0 0 2 glazing, cir low-e 0.310 n 8.68 10.52 15 0 130 158 0 0 0 0 2 glazing, clr low-e _ _ -- 0.310 n 8.68 10.52 - 3Q 0 _260 ------ 316 ___ ____0 __-0 _._-___0 , __0 11 Tailored foam inject 0.000 a 0.00 0.00 353 292 0 0 0 0 0 0 2 glazing, cir low-e 0.310 a 8.68 10.52 12 24 104 126 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 16.07 15 22 130 241 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 14 27 126 127 0 0 0 0 11DO 0.390 a 10.92 11.31 20 2 0 0 0 W Tailored foam inject '0.000 s 0.00 0.00 _20 560 506 - .223 0 b _. 70 _ _ 70 - 0 _ - 0 2 glazing, cir low-e 0.310 s 8.68 , 10.52 9 18 78 95 0 0 0 0 2 glazing, cir low-e 0.310 s 8.68 10.52 ' 45 _ 90 __. 391. _.. 473 _ 0 _ _ _0 _ 0 0- W Tailored foam inject 0.000 w 0.00 0.00 620 _ 423 0 0 100 100 0 0 2 glazing, clr low-e 0.310 w 8.68 30.04 30 4 260 901 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.35 48 96 444 449 0 0 0 0 2 glazing, cir low-e 0.330 w 9.24 9.98 96 192 887 958 0 0 0 0 11DO w 10.92 11.31 23 23 248. 2516 0 0---.- 0 t-D 12C-0sw, .0.390 0.091 _ - 2.55 . 1.28 276 251 639 322 -,- 0 _ _ -__ 0 0 0 11DO 0.390 n 10.92 11.31 19 19 210 -- . 218 0 __- _ -.. 0 _0 _ Q C 16X19-Omd 0.408 - 1.59 1.49 2028 2028 3215 3014 70 70 ill 104 C_ 1713Gal _ 0:105 . - 2.94 4.57 857 857 .- 252.1 39.16 _. 0 ___,___0 _____-_0 F 22A-tpl 0.989 - 27.69 0.00 2742 211 5843 0 70 17 471 0 6 c) AED excursion 2743 -3 Envelope loss/gain 15883 14754 5B2 101 12 a) Infiltration 4775 1279 _ 387 104 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 12 2760 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 20658 20793 969 205 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20658 20793 969 205 15 Duct loads 38% 32% 7775 6737 33% 23% 321 47 Total room load 28433 27530 1289 251 Air required (cfm) 1617 1617 73 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. c wrigF�tsoft" 2017-Dec-13 11:22:42 .4C�P. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N -�- wrightsoft® Right-J® Worksheet Job: Entire House Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name BEDROOM 3 BEDROOM 2 2 Exposed wall 13.0 ft 12.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 13.0 x 13.0 ft 169.0 ftz 13.0 x 12.0 ft 156.0 ftZ Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (Btuh/ftZ-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0' "- 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 2 glazing, clr low-e, Tailored foam inject 2 glazing, clr low-e 0.310 0.310 0.000 0.310 n n_ a a 8.68 8.68 0.00 8.68 10.52 _ 10.52 0.00 10.52 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 . '-0 0 0 0 ___O 0 0 0 j0 0 0 0 __0 0 0 0 _0 0 0 2 glazing, clr low-e 0.310 a 8.68 16.07 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 0 0 0 0 11D0 Tailored foam inject 0.390 0.000 _ e s 10.92 0.00 11.31 0.00 0 130 0 115 0 0 0 _ _ '0 _ _ 0 , 120 O ,X "105 0 ___ -0 0 IW 0 _ f--c� 2 glazing, clr low-e 0.310 s 8.68 10.52 0 0 0 0 0 0 0 0 I G 2 glazing, clr low-e - 0.310 s 8.68 10.52 15 15 130 _. ; 158 _ _ 15 - _^.___ 1-5 130 _ 158 Tailored foam inject 0.000 w 0.00 0.00 0 0 0 _•. 0 0 0 0 _- 0 2 glazing, clr low-e 0.310 w 8.68 30.04 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.35 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.98 0 0 0 0 0 0 0 0 11D0 12C-Osw 0.390 0.091 w - 10.92 2.55 11.31 1.28 0 0 0 0 _ 0 0 0 0 -0 0 _ -_ 0 0 0 0 0 b IT-D 11DO 16X19-0md 0.390 0.408 n - 10.92 1.59 11.31 1.49 _ 0 169 - 0 169 0 268 _.0 251 . -._. 156 156 ---24-7 232 C C 1766a1 0.105'. - 2.94- 4.57 0 0 - 0__-'- --- A-..:--_00. �- .0. ------- 0 F 22A-tpl 0.989 - 27.69 0.00 169 13 360 0 156 12 332 0 6 c) AED excursion -14 -13 Envelope loss/gain 758 395 710 376 12 a) Infiltration 296 79 273 73 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 1054 934 983 909 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 12 11 14 Subtotal 1054 934 995 921 15 Duct loads 33% 23% 349 213 33% 23% 329 210 Total room load 1403 1148 1324 1130 Air required (cfm) 80 EL75 66 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Dec-13 11:e 2 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N -- wrightsoft® Right-J® Worksheet Job: Entire douse Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 2 OFFICE 2 Exposed wall 7.0 ft 13.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 7.0 ft 70.0 ftz 1.0 x 168.0 ft 168.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ft2,-OF) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1N�C Tailored foam inject 6.000 n 0.00 0.00 0 0" 0 0 . _ 2 glazing, clydow-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 I C 2 glazing, clydow-e 0.310 n 8.68 10.52 0 0 0 0 -0 0 0 0 I-G 2 glazing, clr low-e_ 0.310 _ n 8.68 _10.62 _ 0 . 0 . 0 _0 _ ._._ _0. 11 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 16.07 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 0 0 0 0 D 11 DO 0.3.90 a 10.92 11.31 0 0 0 0_ 0 0 0 0 W Tailored foam inject 0.000 s 0.00 0.00 70 61 0 0 _ 130 115 _ _ 0 6 2 glazing, clr low-e 0.310 s 8.68 10.52 9 9 78 - 95 0 0 0 0 2 glazing, cir low-e 0.3,10 - s_- 8.68 10.52 0 0 _ , 0 : _ ._:0 __- 5... _. _ 15 ---IZO, _ r 158 W Tailored foam inject glazing, clr low-e 0.000 0.310 w w 0.00 8.68 0.00 30.04 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D2 2 glazing, clr low-e 0.330 w 9.24 9.35 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.98 0 0 0 0 0 0 0 0 D 11 DO 0.390 w, 10.92 11.31 0 0 L-_ D 12C-Osw 0.091 - ," - 2.55 1.28 6 '0 0 -0. _ _ 7 0 __ 140 1'40 �^ 357 - 180 11DO 16X19-Omd 0.390 0.408 n 10.92 1.59 11.31 1.49 0 70 0 70 111 1.04 6-8 168 266 __0C 250 _ C 176-6al 0,905 • - 2.94 4.57 0 _ 0 0 _ _ F_ 22A-tpl 0.989 - 27.69 0.00 70 7 _ 194 __ _ _0 168 - 13 360 0 6 c) AED excursion -4 -10 Envelope loss/gain 383 195 1113 577 12 a) Infiltration 159 43 296 79 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 542 238 1409 657 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 28 26 16 15 14 Subtotal 570 264 1425 671 15 Duct loads 33% 23% 189 60 33% 23% 472 153 Total room load 759 324 1897 825 Air required (cfm) 43 19 108 48 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft® 2017-Dec-1311:22:42 �� Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ..\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front ,Door faces: N -- wrightsoft° Right-JO Worksheet Job: Entire House Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MUD ROOM PANTRY 2 Exposed wall O ft O ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 88.0 ft 11.0 x 5.0 ft 5 Room area 88.0 ft2 55.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/ft2 °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat ' Cool 6 VbTailored foam inject 0.000 n 0.00 0.00 0 0 0 0 _ - - 0 ^ 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 _ 10.52 0 _ 0 -. 0 J 0 ____0 -__^ Q __ _Q _- -0 11 Tailored foam inject 2 glazing, clr low-e 0.000 0.310 a a 0.00 8.68 0.00 10.52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 16.07 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 0 0 0 0 D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W Tailored foam inject 0.000 s 0.00 0.00 0 0 0 _ _ 0,' _ _ 0 0 _ _ _ �' '0 ___ __ __ y _ 0 2 glazing, cir low-e. 2glazing, clrlow-e 0.310 0.310 s s 8.68 8.68 10.52 10.52 0 0 0 0 0 0 0 ,-__-.---0.... " 0 ___0__._--0-_-___0 0 0 0 -'----0- W Tailored foam inject 2 glazing, cir low-e 0.000 0.310 w w 0.00 8.68 0.00 30.04 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WD 2 glazing, cir low-e 0.330 w 9.24 9.35 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.330 w 9.24 9.98 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 FL12C-Osw 0.091 - 2.55 1.28 60 41 _ _ _-0 _ `D 11DO 0.390 , n 10.92 11.31 19 19 210- C 16X19-Omd 0.408 1.59 1.49 88 - 88 140 131 C 178-6al 0.105 - 2.94 _ . 4.57 0 - 0 - 0 - - 0 _55 --- --0 0 F 22A-tpl 0.989 - 27.69 0.00 88 0 0 0 55 0 0 6 c) AED excursion -6 -1 Envelope loss/gain 454 395 87 81 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 14541 395 87 81 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 40 37 44 41 14 Subtotal 494 432 131 121 15 Duct loads 33% 23% 163 98 33% 23% 43 28 Total room load 657 530 174 149 Air required (cfm) 1--T37 31 10 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. `� ' wrightsoft" 2017-Dec-13 11:e 4 Right -Suite® Universal 2017 17.0.14 RSU08101 Page ' ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N -+- wrightsoft° Right-J® Worksheet Job: Entire House Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY HALL 2 Exposed wall 11.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 1.0 x 151.0 ft 5 Room area 92.0 ft2 151.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Tailored foam inject 0.ObO n 0.00 0.00 60 60 0 0 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 . _ 0 . ..._ 0 . _ _ _ 0 _ 0 y,___ _ 0 _______0_ -__ _- _ 0. 11 Tailored foam inject 0.000 a 0.00 0.00 50 35 0 0 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 16.07 15 11 130 241 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 0 0 0 0 D 11D0 0.390 a 10.92 11.31 0 0 0 0 0 _ wI Tailored foam inject 0.000 s 0.00 0.00 0 _ 0 0 ___ 0 _ _ -' __ __0 ------0 _ _0 ' �- 0 - �-c� 2 glazing, clr low-e 0.310 s 8.68 10.52 0 0 0 0 0 0 0 0 I-G 2 glazing, clr low-e 0.310 s 8.68 10.62 0 _ 0 .. 0 _ _ _ _ 0 _ _ __ _ _ 0 _-_ 0 - ___ 0 .___-___0 w Tailored foam inject glazing, clr low-e O.00o 0.310 w w 0.00 8.68 0.00 30.04 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D2 2 glazing, clr low-e 0.330 w 9.24 9.35 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.98 0 0 0 0 0 0 0 0 D 11 DO 0.390 w_ 10.92 11.31 0 0 0 0 0 0 0 R T-D 12C-Osw ` 0.091 - 2.55 .. 1.28 70 70 178 _- 90 0 _ 0 -_. 0 0 11DO 0.390- n 10.92 11.31 0 0 1 0 --0_ _ _ _ 0 -0 _0 _-____0 C 16X19-Omd 0.408 - 1.59 1.49 92 92 146 137 151 151 239 224 C 1713-6al 0.105 2.94 4.57 0 0 0 _ _ _ 0_.. -_ 0 ___ _0 _ _- _ _!0_ F 22A-tpl 0.989 27.69 0.00 .92 11 305 - 0. ---__151 _-. _0 0 _ -___O 6 c) AED excursion -8 -3 Envelope loss/gain 759 460 239 221 12 a) Infiltration 250 67 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1010 527 239 221 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -239 -221 14 Subtotal 1010 527 0 0 15 Duct loads 33% 23% 334 120 33% 23% 0 0 al room load FA,, 1344 647 0 0 required (cfm) 76 38 0 0 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. wrightsoft' 2017-Dec-1311:22:42 ACCA. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 ...\Quick Caics\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N - wrightsoft° Right-M Worksheet Job: Entire House Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN DINING 2 Exposed wall 0 ft 26.0 ft 3 Room height 12.4 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 12.0 x 21.0 ft 1.0 x 153.0 ft 5 Room area 252.0 ft2 153.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/Wt *F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 ' 0 0 0 110 80 ---6r 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr-low-e 0.310. n 8.68 10.52 .. 0. - .: 0 _ - Q _ _ ._ 0 - 30. _0 _ _, __260 _ _316 11 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 a 8.68 16.07 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 0 0 0 0 D 11 DO 0.390 a 10.92 11.31 0 0 0 0 0 _ 0 _ _ __ _0 w Tailored foam inject 0.000 s 0.00 0.00 0 0 0 0 _ : 0 "0 _ __ _0 __ 0 _ 0 2 glazing, clr low-e 0.310 s 8.68 10.52 . 0 0 0 0 .0 0 0. 0 2 glazing,. clr low-e 0.310 s _ 8.68 - 10.52 0 - 0 O. '_' ._ _01 _ - ,. 0 w Tailored foam inject 2 glazing, clr low-e 0.000 0.310 w w 0.00 8.68 0.00 30.04 0 0 0 0 0 0 0 0 150 30 97 2 0 260 0 901 DD 2 glazing, clr low-e 0.330 w 9.24 9.35 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.98 0 0 0 0 0 0 0 0 11DO 0.390 w_ 10.92 11.31 0 0 0 _ _ 0 - -- 23 23 _-.. _ _..,.� 248 .._ ..__� 256 .... IT-D 12C-Osw 0.091 - 2.55 1.28 0 0 - ^ 0 0 0 r. - 0 . ' _ 0. 0 11DO 0.390 n 10.92 11.31 _ - _ 0 . 0- 0 ::. 0 -__. _`_- -0. _..._. C _.- ... 153 243 16X19-Omd 0.408 1.59 1.49 0 0 0 0 153 227 C 1713-6al 0.105 _ - 2.94 4.57 303 _ 303 890 ._:_.•_1382 ',0 «0 0; 0. F 22A-tpl 0.989 27.69 0.00 252 ., 0 0 0 _ 11153 26 6 c) AED excursion -56 388 Envelope loss/gain 890 1326 1731 2089 12 a) Infiltration 0 0 592 159 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 890 3786 2323 2247 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 48 44 0 0 14 Subtotal 938 3831 2323 2247 15 Duct loads 33% 23% 310 873 33% 23% 769 512 Total room load 1248 4704 1 3091 2760 Air required (cfm) 71 276 176 162 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. wrightsoft® 2017-Dec-13 11:22:42 ACC Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N -# wrightsoft° Right-M Worksheet Job: Entire House Date: Dec 13, 2017 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@4OL.COM 1 Room name GREAT ROOM FOYER 2 Exposed wall 22.0 ft 12.0 ft 3 Room height 12.3 ft heat/cool 10.0 ft heaticool 4 Room dimensions 1.0 x 477.0 ft 12.0 .x 15.0 ft 5 Room area 477.0 ftz 180.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ftz) Load number (Btuhfftz °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 0 0 µ0 0 �, . 0 3 0 0 2 glazing, clr low-e 0.310 _ n 8.68. 10.52 01 0 0 0 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing,, clr:low-e., 0.310 n 8.68 10.52 .0 ,0 _ . 0 __0 0 ::0 .-__- _e Q -_--0. 11 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 _._ 0 . 120 86 0 0 2 glazing, clr low-e 0.310 a 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.310 a 8.68 16.07 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 14 14 126 127 D 11DO 0.390 a 10.92 11.31 0 0 0 0 20 w Ifs2 Tailored foam inject glazing, cWow-e 0.000 0.310 s s 0.00 8.68 0.00 10.52 0 - 0 0 0 0 0 - -0 0 __ 0- 0 _ ____2.0 0 0 __ __22.3 _ 0 0 __2.31 n 0 0. 2glazing,,clr_low-e - 0.310.. &. 8.68 10.52 0 w Tailored foam inject glazing, clr low-e 0.000 0.310 w w 0.00 8.68 0.00 30.04 220 0 _ 124 0 0 0 0 0 0 0 0 0 0 0 0 0 D2 2 glazing, clr low-e 0.330 w 9.24 9.35 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.98 96 96 887 958 0 0 0 0 D 11130 12C-Osw ` 0.390 0.091 w- 10.92 2.55 11.31 1.28 0- 0 0 0 0 . _ .. 0 0 - ... 0 - _ -0 0 0 .__ .. -: -0 0 -: - 0 _0_ - - 0 IL-D 11 DO 0.390 n 10.92. 11.31 _ . 0 0 0 0 _ C 16X19-Omd 0.408 1.59 1.49 15 15 24 22 180 180 285 267 C 17B-6al _, 0.105 _ -,.- 2.94 4.57 " 555 _ 555 1631 _ _--- _ _.._ .. _ F 22A-tpl 0.989 - 27.69 0.00 477 22 606 -2534 0 180 12 332 0 6 c) AED excursion 1775 -10 Envelope loss/gain 3151 5289 966 615 12 a) Infiltration 501 134 273 73 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 01 0 Subtotal (lines 6 to 13) 3652 6344 1239 688 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 33% 23% 0 0 24 3676 1216 0 0 22 6366 1451 46% 70% 0 0 28 1267 588 0 0 26 714 496 Total room load Air required (cfm) 4892 278 7817 459 1 1 1855 105 1211 71 _ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrigi�tsoft" 2017-Dec-1311:22:42 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 7 ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = NIJ8 Front Door faces: N - wrightsoft, Right-M) Worksheet Job: Entire House Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC 2 M BATH 2 Exposed wall 0 ft 22.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 7.0 ft 49.0 ftz 1.0 x 189.0 ft 189.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ft� °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 b "0 ' A 60 _45 0 . "_0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 V 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 15 0 130 158 11 W 2glazing, -clr low-e Tailored foam inject 2 glazing, clr low-e 2 glazing, cir low-e 0.310 0.000 0.310 0.310 n a a a 8.68. 0.00 8.68 8.68 10.52 0.00 10.52 16.07 0 0 0 0 0 0 0 0 0 0 0 0 - -0 0 0 0 . 0 120 6 0 .,0 114 6 0 ;0______.0 0 52 0 0 63 0 2 glazing, clr low-e 0,330 a 9.24 9.35 0 0 0 0 0 0 0 0 D 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 W Tailored foam inject 0.000 s 0.00 0.00 0 0 0 0 ' 40 40 ___ __ _ `: 0 ____ ' _ _0 LI--G 2 glazing, clr low-e 0.310 s 8.68 10.52 0 0 0 0 0 0 0 0 L C� 2 glazing, clr low-e 0.310 s 8.68 10.52 0 0 0 _ -'0 . _0. ___ __ _ 0 _ _ __0, - _-_ -;0, W Tailored foam inject glazing, clr low-e 0.000 0.310 w w 0.00 8.68 0.00 30.04 0 0 0 0 0 0 0 0 -. 0 0 0 0 0 0 0 0 D2 2 glazing, cir low-e 0.330 w 9.24 9.35 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.98 0 0 0 0 0 0 0 0 D 11DO 0.390 w 10.92 11.31 0 0 0 0 0._____ 0 `T_D 12C-Osw 0.091 2.55 1.28 0 0 0 0 -,_.- _ 0 _.,0 0 ,0 _7-0 .. _0 11D0 16X19-Omd 0.390 0.408 - n - 10.92 1.59 11.31 1.49 0 49 0 49 0 78 _ 0 73 . 0 189 0 189 0 300 281 C C 17B-6al 0.105 - 2.94 4.57 0- 0 0 .- . - 0 _- _ ! F 22A-tpl 0.989 - 27.69 0.00 49 0 0 0 189 22 609 0 6 c) AED excursion -1 -9 Envelope loss/gain 78 72 1091 493 12 a) Infiltration 0 0 501 134 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) I 78 72 1592 627 Less external load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 46% 70% 0 0 78 36 0 0 72 50 46% 70% 0 0 1592 738 0 0 627 436 Total room load Air required (cfm) I 114 6 122 7 1 2331 133 1062 62 ® Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft22 , Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Dec-13 11:Page ge 8 8 14CC�` ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N - wrightsoft° Right-M) Worksheet Job: Entire House Date: Dec 13, 2017 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC MASTER BEDROOM 2 Exposed wall 12.0 ft 31.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 8.0 x 12.0 ft 96.0 ft' 1.0 x 288.0 ft 288.0 ftz Ty Construction U-value Or HTM Area (ftJ Load Area (ftJ Load number (Btuh/ft? °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 120 120 0 0 160 140 ' _T 0 0 V 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 20 0 174 210 2 glazing, cir low-e 0.310 n 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing,-clr low-e 0.310 n 8.68 10.52 0 0 0 0 . __0 _ 0 11 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 _ 0 _ _ 0 _ 0 0 0 2 glazing, cir low-e 0.310 a 8.68 10.52 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.310 a 8.68 16.07 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 0 0 0 0 D 11DO 0.390 a 10.92 11.31 0 0 0 0 wII Tailored foam inject 0.000 s 0.00 0.00 0 0 _ 0 _ __ _ '0 0 - 0 0 -0 __ I--c� 2 glazing, clr low-e 0.310 s 8.68 10.52 0 0 0 0 0 0 0 0 I� w 2glazing, clrlow-e .. Tailored foam inject glazing, clr low-e 0.310 0.000 0.310 s w w 8.68 0.00 8.68 10.52 0.00 30.04 _0 0 0 0 0 0 ._-_.0 0 0 _-__-_0 0 0 _0_..000 150 0 102 0 0 0 0 0 D2 2 glazing, clr low-e 0.330 w 9.24 9.35 0 0 0 0 48 48 444 449 2 glazing, clr low-e 0.330 w 9.24 9.98 0 0 0 0 0 0 0 0 D 11 DO 0.390 w 10.92 11.31_ 0 0_ 0 R 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 D 11D0 0.390 n 10.92 11.31 0 0 0'0.,_._._.._0_�_�0____�-_0.__._�_'_0. C 16X19-0md 0.408 - 1.59 1.49 96 96 152 143 288 288 457 428 C 1713-6al 0.105 _ - 2.94 4.57 0 0 - - - 0 _-- ......._0 _- -- ____0F 22A-tpl 0.989 - 27.69 0.00 96 12 -0 332 _ _ 0 .288 31 858 0 6 c) AED excursion -3 723 Envelope loss/gain 485 140 1932 1810 12 a) Infiltration 273 73 706 189 b) Room ventilation 0 0 01 0 13 Intemal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 758 213 2638 2460 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 758 213 2638 2460 151 Duct loads 46% 70% 351 148 46% 70% 1224 1710 Total room load 1109 361 3862 4169 Air required (cfm) 63 21 220 245 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Pk wrightsoft- 2017-Dec-1311:22:42 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 9 ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Calc = MJ8 Front Door faces: N -�- wrightsoft° Right-JO Worksheet Job: Entire House Date: Dec 13, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name TLT. 2 Exposed wall 13.0 ft 3 Room height 9.0 ft heat/cocl 4 Room dimensions 1.0 x 39.0 ft 5 Room area 39.0 ft' Ty Construction U-value Or HTM Area (W) Load Area Load number (Btuh/ft? °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 6.00 54 54 0 0- � 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 0 0 0 2 glazing, clr low-e 0.310 n 8.68 10.52 0 _ 0 _ 0 0 11 Tailored foam inject 0.000 a 0.00 0.00 63 57 0 0 2 glazing, clr low-e 0.310 a 8.68 10.52 6 6 52 63 2 glazing, clr low-e 0.310 a 8.68 16.07 0 0 0 0 2 glazing, clr low-e 0.330 a 9.24 9.35 0 0 0 0 D 11DO Tailored foam inject 0.390 0.000 a s 10.92 0.00 11.31 0.00 0 0 0 0 0 0 _ 0 0 - W L22 glazing, clr low-e 0.310 s 8.68 10.52 0 0 0 0 2 glazing, clr low-e 0.310 s 8.68 10.52 0 0 0 0 _ __ -____•,_ _ _ _- _ W Tailored foam inject 2 glazing, clr low-e 0.000 0.310 w w 0.00 8.68 0.00 30.04 0 0 0 0 0 0 _ - .. 0 0 __ _ _ -_ _ _._ _ WD 2 glazing, clr low-e 0.330 w 9.24 9.35 0 0 0 0 2 glazing, clr low-e 0.330 w 9.24 9.98 0 0 0 0 11D0- . 0.390 w- 10.92 11.31 0 0 0 0 �12C-Osw 0.091 - 2.55 ._ 1.28 0 0 0 0 D C 11DO 16X19-Omd 0.390 0.408 n - 10.92 1.59 11.31 1.49 0 39 _ _ 0 39 _ -_ 0 62 _ 58 _ C 17B-6al 0.105 - 2.94 4.57 -0 _ 0 _ - 0 .- 0- F 22A-tpl 0.989 - 27.69 0.00 39 13 360 0 6 c) AED excursion -3 Envelope loss/gain 474 118 12 a) Infiltration 266 71' b) Room ventilation 0 0 13 Intemal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 740 190 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 740 190 15 Duct loads 46% 70% 343 132 Total room load 1084 321 Air required (cfm) 62 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Dec-1311:22:42 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 10 ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Cale = MJ8 Front Door faces: N TF 9 0 Duct System Summary Job: Wrl htsoft ' % Date: Dec 13, 2017 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project• • For: RYAN & ANGELA DOYLE BALD CYPRESS TRAIL, FT. PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.258 in/100ft 0.258 in/100ft Actual air flow 1617 cfm 1617 cfm Total effective length (TEL) 194 ft Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 759 43 19 0.477 4.0 Ox 0 VIFx 9.9 95.0 BATH 3 h 1289 73 15 0.283 4.0 Ox0 VIFx 41.7 135.0 st1 BEDROOM 2 h 1324 75 66 0.341 6.0 Ox0 VIFx 31.6 - 115.0 st1 BEDROOM 3 h 1403 80 67 0.345 6.0 Ox0 VIFx 30.1 115.0 st1 DINING h 3091 176 162 0.281 7.0 Ox0 VIFx 42.8 135.0 st1 FOYER h 1855 105 71 0.334 6.0 Ox0 VIFx 34.8 115.0 st2 GREAT ROOM C 3908 139 230 0.331 8.0 Ox0 VIFx 36.0 115.0 st2 GREAT ROOM-B C 3908 139 230 0.308 8.0 Ox0 VIFx 47.2 115.0 st2 KITCHEN C 2352 35 138 0.345 7.0 Ox0 VIFx 30.1 115.0 st1 KITCHEN -A c 2352 35 138 0.337 7.0 Ox 0 VIFx 33.3 115.0 st1 LAUNDRY h 1344 76 38 0.462 5.0 Ox 0 VIFx 13.2 95.0 M BATH h 2331 133 62 0.267 6.0 Ox 0 VIFx 52.5 135.0 st3 MASTER BEDROOM c 2085 110 122 0.262 7.0 Ox 0 VIFx 55.8 135.0 st3 MASTER BEDROOM -A c 2085 110 122 0.277 7.0 Ox 0 VIFx 45.5 135.0 st3 MUD ROOM h 657 37 31 0.500 4.0 Ox 0 VIFx 5.0 95.0 OFFICE h 1897 108 48 0.495 6.0 Ox0 VIFx 6.0 95.0 PANTRY h 174 10 9 0.471 4.0 Ox0 VIFx 11.0 .95.0 TLT. h 1084 62 19 0.258 4.0 Ox0 VIFx 58.9 135.0 st3 WIC h 1109 63 21 0.275 5.0 Ox0 VIFx 46.6 135.0 st3 WIC 2 C 122 6 7 0.331 4.0 Ox0 VIFx 36.1 115.0 st2 wri htsoftp 2017-Dec-1311:22:44 �, 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 �CA ...\Quick Calcs\DocumentskDOYLE, RYAN & ANGELA.rup Calc ='MJ8 Front Door faces: N Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 477 347 0.258 874 10.0 0 x 0 . VinlFlx st2 st2 Peak AVF 867 885 0.258 827 14.0 0 x 0 VinlFlx st1 Peak AVF 475 587 0.281 889 11.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1617 1617 0 0 0 0 Ox 0 VIFx A * wri htsoft® 2017-Dec-13 11:age 2 ti 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 �CA ...\Quick Calcs\Documents\DOYLE, RYAN & ANGELA.rup Cale = MJ8 Front Door faces: N