HomeMy WebLinkAboutFBC ENERGY CONSERVATION CODEE
Cou TY
-F' it O It D A
Planning & Development Services; Building &-Code Regulation Division
2300 Virginia Ave, Rm 201; Fort Pierce; FL 34982
772-462-2165 Fax 772-462-6443
FBC ENERGY CONSERVATION CODE R402.4.1.2
House Infiltration Test (Blower Door) Certification
Prescriptive and Performance Method
Date: L l8 Permit #: %
Contractor: T-,g -HnnT-,nr,c
Job Address:
Construction:
1A 0 �L tt -�bcr P i ce-e- E PL
New Construction—Gernplete _i
ng After Ad ditiffing
House Infiltration Test Results
CFM (50) = 132-3-
Volume =�cg�-
SLC Climate Zone 2
Test Date:
ACH (50) = CFM (50) x 60 / Volume chanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less (Pass ( ) Fail
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing
shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conductine the test and Provided to estina
penetrations of the
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the
accordance with Section M1507.3
Testin, Companv
Company Name: UTECL Address: 915t ow Qs ,'�ks�n L��
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section 11402.4.1.2 Climate Zone 2.
Signature
Printed Name: Kx3CY9 Qf fAiZS'I—
License/Certification #: __ yit 7670W