FL #
FL19902
Application Type
New
'Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer
Metal Sales Manufacturing Corporation
Address/Phone/Email
545 South 3rd Street, Suite 200
Louisville, KY 40202
(502) 855-4300
dstermer@metalsales.us. com
Authorized Signature
David Stermer
dstermer@metaisales.us.com
I 71 Z � D�y
{ O D�Ji�Il1N
ST. LUCP_E CO.;-'-''TTY B
IR.EVTEWED FOR NCSE
Technical Representative
REVIENVED BY
Address/Phone/Email
DATE
S BE IGPT ON
Quality Assurance Representative
PLANS AND P _ IIT ,
OR NO DiSPE ION AVILL $E 14ADE•
Address/Phone/Email
category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12131/2020
Validated By Yoosef Lavi, P.E.
, Validation Checklist - Hardcopy Received
Certificate of independence 2g02 RO GOi CArtiflcateind�pendence odf
Referenced Standard and Year (of Standard) Standard Year
UL 1897 2004
UL 580 2006
ALLMANUFACTURES LABLES SHOWING
EquivaleR WgAMNi4sC COMPLIANCE
Certified ByWITH FBC ENERGY CODE MUST CONCEALED FASTENERS OR ATTACHMENTS
REMAIN ON ALL DOORS AND WINDOWS ARE THE RESPQNSfe1UTM OF THE
Sections LhpI 7. S ARE APPROVED CONTRACTOR OF RECORD
Product Approval Method Method i Option D
AO
File Copy
Date Submitted
02/13/2016
Date Validated
02/18/2016
Date Pending FBC Approval
02/22/2016
Date Approved
04/12/2016
c......Nmry of DrnduCks
FL #
Model, Number or Name
Description
19902.1
5V-Crimp
Min. 26 ga., 24" wide through fastened roof panel over min.
15/32" thick plywood deck or 7/16" thick OSB with fasteners
through panel rib.
Limits of Use
Installation Instructions
RO II F_ �{ onRPnprt�2076 1 ndf
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FLI M9
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5
other: Uplift load of 30.0 psf at fastener spacing of 36" o.c.
Evaluation Reports
FL19902 RU AE EvaluatiOnRPportCZQ76 7 .pdf
and 172.5 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
Bark Next
contact us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850487:182
The State of Ronda is an AA(EEO employer. 0000fiahr 2007-20+3'"te of Honda :: IWAO �rawme - — -- -
under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a Publicrewrds request, do not seal eledUCO"c
mail to this entity. Instead, contact the office by phone or by bediticnal mail. If you have any questions, please contact 650.487.1395. *Pursuant to Section 455.275
(1). Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one The
emails provided may be used For official communication with the licensee. However email addresses are pudic record. if you do not wish to supply a personal address,
please provide the Department with an email address wWch can be made available to the pudic. To determine if you are a licensee under Chapter 455, FS., please
dick bM..
Product Approval Accepts:
FFecl a
Cfedii Csfd
Safe
EVALUATION REPORT OF
METAL SALES MAIN UI*AcmRING CORPORATION
'26 GA. W-CRIMP PANEL'
FLORIDA BUILDING CODE 5 "' EDITION (2014)
FLORIDA PRODUCT APPROVAL
ILL 19902.1
ROOFING
METAL ROOFING
Prepared For:
Metal Sales ManufacturingCorporation
545 South 3' Street, Suite 200
Louisville, ITV 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing,. Ave., Suite C
Tulsa, OIL 74106
Telephone: (918) 492-5992
FAX: (91.8) 493-3568
This report consists of
Evaluation Report (3 Pages including cover)
Installation Detaiis (1 Page)
Load Span Table (1 Page)
Report No. C2076-1
Date: 2.13.16
4ti®®'®cKALEiVG -'®8,oe
®o �.i .` y •• o
4UJX
�. ®� • ' Lu
s ��
Manufacturer:
Product Name:
Panel Description:
Materials:
Deck Description:
Deck Attachment:
(Minimum)
Underlaymcnt:
Slope:
FL 19902.1
C2076-1
2.13.16
Page 2 of 3
Metal Sales Manufacturing Corporation
5V-Crimp
24" wide coverage with (5) 112" high ribs
Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Min. 7/16" thick OSB or min. 15/32" thick plywood at max span of 24"
for new and existing constructions. Designed and installed as per FBC
2014.
8d x 2.5" long ring shank nails or #8 x 2" long wood screws L 6" o.c.
in the plywood field and edges
Minimum underlayment as per FBC 2014 Section 1507.4.5.1
1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2.
Design Uplift Pressure: 30.0 psf L fastener spacing of 36" o.c.
(Factor of Safety = 2) 172.5 psf @, fastener spacing of 6" o.c.
Fastener Pattern:
Type: #9-16 or # 1.0-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum of
3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 6" o.c. across panel width
At intennediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL 1897-04 `Uplift Tests for Roof Covering
Systems'.
Code Compliance: The product described herein has demonstrated compliance with. FBC,
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This evaluation report
is not applicable in High Velocity Hurricane Zone. Fire classification is
not within scope of this Evaluation Report. Refer to FBC 2014 Section
FL 19902.1
C2076-1
2.13.16
Page 3 of 3
1505 and current approved roofing materials directory or ASTM
C 108/UL790 report from an accredited laboratory for fire ratings of this
product.
Supporting Documents: UL580 & 1897 Test Reports
PRl Construction Materials Technologies
MSMC-017-02-01, Reporting Date 9/20/13
PA.411 ovEr LnF-%
W-CRIMP 1 FASTERM AT PA14ft FIAT
�
SEE DETAIL 2 / /-SEE DETAIL 1 r E DS FED FOR PAWL
`� f et
bI t i f
FAS7EIaF.F, SPAC!yC 0.5 PER
I I J URi1A:UM ATTACHMENT: U..S+GN UPLIFT :OAD TAME
1 {}} 2d x W LONG RA4G SHANK UNL NI
UNDEttLArh ;ii 5NPLL BE IHSTAIEQ I! QR itd z 2" LOT1G PlJCO SCREWS INSTALLATION SPACFO � 6" RC. PT THE REL0
1 F
GInGEL�NEs _._ & AT EDGES
\- N. 2X- WOOD RATTER/JOIST/ g; g
TRUSS AT MAX. 2t" Q.C.
N
TYPICAL PANEL INSTALLATION X—SECTIONre
WN
r
85-16 OR �!10-Iv NDOI?;iCREMS
W1,16 SELF SEALUIG BIAS?0 AT
mxlmtw SPACING OF 36" O.C.
tu-: NJ
cV- RIMP
WW, J
MIN 2E �
-
=_
a. rdtCH� itODF PANEL Flti &5E': CES!Cf1ED IN ACCQRDA":CE wRH THE
FLCRiDA EUMUG CODE (M). 0-
a
UNI'/ERLAlNE9TT ?, RMF PANELS SNAL 0F: ht"C. '1.6 GA. L = 0.010-), EFFECTME C0&MM 2
DETAIL 1 ow 7/ tg' THICK [TAN,) C'R thpTH OF PANEL 24 ( a" W
PLYWOOD 15/37" THCK (VAL) 3. THE ROOF PANELS SNAL EE INSTALLED CYER SHCATH14C & SIR'
SPECIFIED AS
SPECIFIED ON THIS DW MXL
4. REQUIRED DESICH WIND LOADS SHALL 6E CETERMx1ED FOR EACH PROJECT. THIS
R9_16 OR JIO-14 WOWSCReNS PANEL FATFEA! MAY NOT E 1 a,-IED W71ER THE REQUIRED OESKrY IS G LOADS
.G, � d
IRTH SELF KALING' WASHER AT ALL GREATER TltMJ THE DESICC ORDA PRESSURES SPEC!FIFD ON HE O!RLriG.'G. d 6
MVIMUM SPA! xG CF 36" O.C. 5. � FASTENERE. !!'AST VI FE ACCORDANCE WITH THIS ORd� M4 &THE FlL4Z+0A
T3uTDftn^. COD-'_. IF A DIFFERc'NCE OCCURS 9EIWEEN THE MLY!MUId YY,
i A REQUIRE.I)ZNTS CF THIS ORAP+!NG & THE. CODF'• THE CCOE SlMt C0147IRM
6, TIAM. n/JO!97S/1RUSSES MUST RE DESIGNED TO WITHSTAND WIND LOA.7 AS
5V-CRItAP REQUIRED FCR EAw'H AP?UCATON AI4D AF.E THE RESPONS'D!UTY QF QTRERS.
yr ,AF1H 26 �,A.
1
w1DERurvU:; i �GSD 7/16- TaCIC (Tax.) OR 2076-i
DETAIL 2 PL-WObD 15,32" THICK WIN.) t �* t
METAL SALES MANUFACTURING CORPORATION
26 GA. SV-CRIi►IP PANEL
Design Uplift Loads
Description
Fastener Spacing
along; panel letlgth
(in)
Allowable Uplift
Load
{pst`}
W-Crimp Panel
6
172.5
Min. 26 ga.
9
120.0
1?
90.0
Panel fasteners
15
72.0
49-16 or # 10- ] 4 hex head
1 b
60.0
wood screws with sealed
? ]
51.4
washer
24
45.0
27
40.0
30
36.0
33
32.7
.36
30.0
;lutes:
1. The hold numbers ittdiate design loads calculated from test data with satety factor of 2.
2. Panels must be installed as per Evaluation Report FL 19902.1 and Metal Sales current installation
procedure.
1216 N Lansing Ave.. Suite C
Tulsa, Ok 74106
9184925992
r�aooteea®e:o
' 4.
a y p[ •®
® ° � LU
-0 Sloe of
®dam°
®`�, ��� Pin ®"�'��►
Bala Sochalingant. P1LD,, P.L.
FL 62240