Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL 3-21-18Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. GuIfPBRTM Roof Panel over 15132" Plywood /'t_ 64 9 Flo ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COM L�AY/ Chi REVIEWED BY . SVa DATE PLANS AND PERMI MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE t rida Product Approval #11651.17 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 —D REVISION Category: Roofing Subcategory: Metal Roofing >mpliance Method: 61 G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. PN1EL S.• h.�,,� 14429 SW 2nd Place, Suite G30 �•'\,10ENSF y2' Newberry, FL 32669 . Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 * , No. 75519 0•, STATE OF •'Q: IAONA L 04 0"• "I)too I11"10/0.5/201j �aw -'00 pW Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfPBRTm Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 11A" Tall Rib at 12" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing, 1Y4-14 x 7/8" HWH with sealing washer at 24" O.C. Maximum at the panel side laps or approved equals 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design Uplift Pressures FL# 11651.17 R3 9 OCTOBER 5, 2017 Table "A" Maximum Total Uplift Desigrl�Paessure 5= .2¢5 nsf " ` 1 154.75 ps Fastener Pattern 12"-12"-12" 7"-5"-7"-5"-7" Design Pressure includes a Safety Factor = 2.0. Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST 5328) Report No. 117-0062T-07G-H, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. FL# 11651.17 R3 • OCTOBER 5, 2017 w �/� :` . W Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.17 R3 9 OCTOBER 5, 2017 ENGINEER LOAD TABLE: 26 Ga. GulfPBRTM Panel over 15/32" Plywood , =-Pl § % `.:N ., �... .v. e #'. Sf3 Ys' ,a�i ! 3 M, f- F"aI �. ,. d f zF t' I,�* {'"�f/',' �'; Buildmgs haulrlg a Roof Meahn, 6ight-k, 0 a Roof Shope 42 /12 ,12 /12 Gabie or � IIp; Roof Uil nd Speeds 1k20 �� . ?s`#e ei ., $ �Bi(t` :l rrdasB''Idm Coele017. «�� C,�Islc CategoryRllEnclosed „180mph.Exposure w. u sdln-g;as ::. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. 1/4" Penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE a, SPiy wood 24"1t7 YP..E 1 24r' TYPE,1 24 TYP,E 1 24", TYRE 1TYPE,1 24", TYPE 1 24", TYPE.1, a Woo ZONE 2 #9-15x1.5" Plywood 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 12", TYPE 2 12", TYPE 2 "Z"#9-15x1.5' ., Plywood 24', IYPE 1 24" TYPE 112", TYPE 2 Z', PE 1 1.) PANEL DESCRIPTION: GULFPBRTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 11/4" TALL. 2.) PANEL FASTENER: #9-15X1.5" W/SEALING WASHER OR APPROVED EQ., 1/4-14X7/8" LAP SCREW MAX. 24"O.C. IN PANEL SIDELAP. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 59.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 154.75 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN. 15/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE 2 rnr nuvr a ZONE 3-� ------------------ RIDGE ZONE EAVE Note: Dimension (a) is defined as 10% of the minimum width of the building or a 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be less than either 4% of the minimum width of the building or 3 feet. ZONE 2 GABLE ROOF —�—------------------ —ya I I I RIDGE -----�--------------- a -------------------------4- Aa V I ZONE 1 � I � I "-ZONE3 HEAVE FL# 11651.17 R3 • OCTOBER 5, 2017 TYPE I FASTENER PATTERN At Panel Lap #1/4-14 x 7/8" Lap Screw @ 24" O.C. Max. �12"-12"�12" (1) #9-15 x 1-1/2" w/Sealer Washer TYPE 2 FASTENER PATTERN #1/4-14 x 7/8" Lap Screw @ 24" O.C. Max. 'T- 7, �T -T �T (1) #9-15 x 1-1/2" w/Sealer Washer