Loading...
HomeMy WebLinkAboutPROJECT SPECIFICATIONSGENERAL NOTES 1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2014 FLORIDA BUILDING CODE, 5TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SE17 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 2. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 170 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: D 3. SCREENED ROOF ENCLOSURE FBC 2014 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 II. AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 % - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60 II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ALUMINUM SPECIFICATIONS: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE SPECIFIED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH BE PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1'X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS: 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4101.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. i ` ` 95 ` " 9 s DEC 15 2011 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. LEGEND: (ALL MAY NOT APPL SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X = HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"4.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"4.044" 2 x 5: 2"x5"4.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"0.044" 1 x 3: 1 "x3"x0.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7"x0.057"x0.120" 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"x0.092"x0.398" NOTE: AS INDICATED AOVE ALL MEMBER PROFILES ARE INDICATED IN INCHES. V z_z w LLI z_ w Q 0 010-0 LL U J J C) 0) co cy) p o U p0 co U CD LL LoLU ' L � N M c: 0 N O a_ w m N 00 0 w U U Ln L0 M M ti T_ Z w p w Z U U Q J 66 U w w w cl)W OchF } U � � Z O F zool--< z �rnpU) IL W DESIGN DATE: 11/27/2017 REVISION 1: 12/12/2017 PAGE: REVISION 2: DATE SCALE: NTS GENERAL NOTES AND SPECIFICATIONS: 1-THE STRUCTURES INDICATED HERIN ARE DESIGNED TO BE INSTALLED WITHIN MASONRY OR WOOD FRAME HOST STRUCTURES OF ADEQUTE STRUCTURAL CAPACITY. THE CONTRACTOR SHALL VERIFY THAT THE HOST STRUCTURE IS IN GOOD CONDITION AND OF SUFFICIENT STRENGTH TO SUPPORT THE PROPOSED ADDITION. 2-ALUMINUM EXTRUSIONS SHALL MEET THE STRENGTH REQUIREMENTS OF ASTM B221 AFTER POWDER COATING. 3-ALL ALUMINUM EXTRUSIONS ARE TO BE A MINIMUM 6063 T6 DESIGN STATEMENT: THE INDICATED SCREEN/GAURD RAILING SYSTEMS USE LOADS FROM SECT 1607.7 OF THE FLORIDA BUILDING CODE 2014-5TH EDITION APPLICABLE CODES, REGULATIONS & STANDARDS: 1.THE 2014 FLORIDA BUILDING CODE, 5TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23, WOOD AND AA ASM 35 and AA ADM 1 2. ASCE 7-10. LIVE LOADS PER TABLE R301.5 GUARDRAILS AND HANDRAILS - 200 PSF, A SINGLE CONCENTRATED LOAD APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP GUARDRAIL IN -FILL COMPONENTS - 50 PSF ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL W/ (4) #10 X .75" INTO GIRT OR PURLIN AND (2) # 14 X .75" INTO BEAM OR UPRIGHT 0.062 ANGLE (4) #10 X 1.5" SMS CLIPS MAY BE USED INTO SCREW BOSS S / (INTERNAL) PURLIN, GIRT UPRIGHT, BEAM - SNAP, HEADER OR T_ SELF MATING OR HOLLOW SILL GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS DETAIL C 24'-4" N co 1 X2 (TYP.) co co c� X 2X3 (TYP.) N N N N 1X2 (TYP.) 6'-1 " 6'-1 " 6'-1 " 2'-10" INSTALLATION NOTES: 1-FASTEN PERIMETER TO WD FRAMING W'1/4"X2-1/2" GALV LAG BOLTS 24" O/C AND WITHIN 6" OF INTERSECTING MEMBERS AND JOINTS. 2-FASTEN PERIMETER TO MASONRY W1/4" X 2-1/4" TAPCON 24" O/C AND WITHIN 6" OF INTERSECTING MEMBERS AND JOINTS. NOTE: ANCHORS INTO HOST SHALL HAVE A (MIN.) EMBEDMNET OF 1-1/4" (TYP.) VARIES SEE PLAN 1x2 PERIMETER LU 0_ LLI U) O FOR SCREW SIZE & INSTALLATION W O OF THE WINDOWS SEE THE I j 0 MANUFACTURER DETAILS 2 w ATTCHED TO THIS PACKAGE E= d0 cli Q CHAIR RAIL PER PLAN OR SCREW SIZE & INSTALLATION OF THE WINDOWS SEE THE MANUFACTURER DETAILS ATTCHEO TO THIS PACKAGE 1x2 PERIMETER Varies -See plan w z d z w ILL! U VARIES g SEE PLAN ¢a z� w pN au) (TOP) ASSEMBLY NOTES: 1-FASTEN PERIMETER MEMBERS AT CORNERS (INTERNAL) W/(2) #10 X 1-1/2" SMS INTO SCREW BOSSES 2-FASTEN CHAIR RAIL (INTERNAL) TO PERIMETER W/(4) #10X1-1/2" SMS INTO SCREW BOSS OF CHAIR RAIL. ALTERNATELY DETAIL C. CHAIR RAIL SEE INSTALLATION NOTES FOR ANCHORAGE FIG 1 (BASE) NTS V z_ w z n '_ V W Q O J EL U J J 00 co co p o U p U O m LL LoUJ L M C Lr Q U 0 d N O O LLI a 1= 0 T3 c7 w 0I 2 U Lo Lo cM m ti Z w w p � U Z Q w -J U w W w Lu MO H ❑ � U) Z ❑ Z Q F- ZLoZ n- W �rn�U) DESIGN DATE: 11127/2017 REVISION 1: DATE PAGE: REVISION 2: DATE n SCALE: NTS L