HomeMy WebLinkAboutSHED MASTER PLANPSI APPROVAL 2015-05-24 160 mph - Metal Lapsider Sox Eave Shed Master Plan GENERAL NOTES: I . THI5 STRUCTURE WAS DESIGNED IN ACCORDANCE WITH THE 2009 IBC BUILDING CODE AND THE FLOW DA BUI LDI NGCODE. WI ND LOADING DESIGNED IN ACCORDANCE WITH THE A5CE - 7-10. 2. ALL MATERIALS AND LABOR SHALL BE IN ACCORDANCE WITH THE ABOVE CODE AND ALL OTHER. APPLICABLE LOCAL CODES AT THE TIME OF MANUFACTURE. 3. WRITTEN DIMEN5101,15 SHALL TAKE PRECEDENCE OVER SCALED DIMENSION. 4. OUT5IDE OVERALL DIMEN51ON5 CAN VARY BETWEEN LIMITS SHOWN BUT MEMBER SPACING SHALL NOT EXCEED UMIT5 AS INDICATED. 5. LUMBER USED FOR CONSTRUCTION SHALL BE AS FOLLOWS: FLOORJOI5T5- 2x45.Y.P.#2-(12-15%M015TURECONTENT) 2xG 5.Y.P.#2-(1 2-1.5%_M015TURE.CONTENT) 2x8 5.Y.P.#2-(12-15% M015TURE CONTENT) G. ALL OF THE FOLLOWING LUMBER SHALL BE PRESSURE TREATED: SKIDS, FLOOR JOI5T5 AND 3/4" TEG FLOOR SHEATHING 7. TPU55 DESIGNED TO SUPPORT D.L.+L.L=30 P.5.F. 8. HANDICAP ACCESS TO BUILDING 15 FIELD INSTALLED BY OTHERS AND SUBJECT TO LOCAL JURISDICTION APPROVAL. 9. ALL ALUMINUM TO BE 3005-3105 ALLOY WITH 32,000 P51 MINIMUM YIELD STRENGTH. 10. ROOF SLOPE SHALL BE 3:12 WHEN SHINGLES ARE APPLIED, SEE FBC 1507.2 FOR SHINGLE REQUIREMENTS. ROOF SLOPE FOR METAL R0OF5 SHALL MEET MANUFACTURER'S RECOMMENDATIONS. 11. ROOF RAFTERS SHALL HAVE THE SAME SPACING AS THE WALL STUDS AND SHALL BE LOCATED DIRECTLY OVERTHE WALL STUD. 12. ROOF SLOPES BMNIEEN 2:12 AND 4:12 SHALL HAVE A DOUBLE UNDERLAYMENT APPLICATION IN ACCORDANCE WITH SECTION 1507.2.8 OF THE F.B.C. 2010 13. ANCHORS SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE LOCAL.CODE5 AND T11I5 15 NOT A FOUNDATION DESIGN. 14. BUILDING 15 CLASSIFIED AS TYPE "S' (STORAGE) 15. ALUMINUM WINDOWS - TYPE. SIZE, QUANTITY, AND LOCATION MAY VARY. I G. ALL FASTENERS INTO P.T. WOOD SHALL BE HOT DIPPED GALVANIZED FASTENERS. 17. MANUFACTURER INSTALLATION STANDARDS SHALL BE FOLLOWED IN ORDER FOR THESE DESIGN DRAWINGS TO ACCURATELY REFLECT FIELD PERFORMANCE CONDITIONS. 18. THESE 5TRUCTURE5 SHALL NOT BE USED FOR COMBUSTIBLE OR HAZARDOUS MATERIAL 20. OPTIONAL EXTERIOR WALL COVERINGS INCLUDE CORRUGATED ALUMINUM, MA5A ALUMINUM. 4' LAP ALUMINUM, 5/8' P.T. T I - I I SIDING. VINYL SIDING WITH ENERGY BRACE BACKER, HARDI BOARD, STEEL SIDING AND "PLEKO' STUCCO ON 5/8' DENSE GLA55 GOLD AND POLYCARBONATE GREENHOUSE PANELS 21. AL DOORS SHALL BE ABLE TO BE OPENED FROM THE EGRE55 51DE WITHOUT THE USE OF A KEY. Raney Associates, Inc. Engineering & Construction Planning P.O. Do:348, Six Mile, S.C. 29682-PhoumM8 646.7600 Lark Builders 409 Dixon Street Vidalia, GA 30474 Sheet Index S1.0 , Cover - General & Design Notes S1.1 Electrical & General Floor Plan S1 2 Skids & Floor Framing Plan S1.3 - 1 Skid and Floor Framing Details S1.4 Roof Framing & Schedule S1.5 S1"6--1- Typical Frame Section Details End Wall Frame Options GENERAL NOTES CONTINUED: 22. DOOR SHALL BE 2 1/4' x I I / I G' ALUMINUM EXTRUDFO FRAME WITH AN ALUMINUM PANEL INSERT. ALUMINU' 4 TRIM. DOOR ATTACHED TO VERTICAL 2x4. 23. OPTIONAL DOORS INCLUDE DOUBLE ALUMINUM DOORS, GARAGE DOORS, GO' x 72' ALUMINUM DOOR. 32' • ND 48' SINGLE DOORS, AND PRE HUNG STEEL DOORS. YPE, SIZE. QUANTITY, AND LOCATION MAY VARY. 24. PREMANUFACTURED DOORS THAT MEET APPLICABU_ CODE5 MAY BE USED INSTEAD OF DOORS LISTED ABOVE 25. MAXIMUM WALL HEIGHT TO BE 8'-0' 2G. ALL BRAND MATERIALS SPECIFIED MAY BE 5U5STITU ED FOR EQUIVALENT OR GREATER PRODUCT. 27. ALL BUILDINGS (EXCEPT THOSE IN USE AS AN ACCE5DORY BUILDING FOR A ONE OR TWO FAMILY DWELLING UN 'ER 4005,1.fL.) MUST HAVE ATLEA5T (1) 32 k8C" (MIN.) ODOR. 28. ROOF FRAMING AND WALL FRAMING TO BE 3& MET,`'_ 5TUD5 SPACED AT A MAXIMUM OF 24' O.C. -I hese plans were Designed in accordance wit 2014 FBQ 511 Edition 2011 NEC 2014 Florida Fire Prevention Code For Wind Speed 160 mph, Exposure C DESIGN PARAMETERS: (HIP -GABLE ROOF) (WIND DESIGN PER %SCE 7- 00. SEISMIC DE51GN PER Ai5C 341-051 WIND VELOCITY: I GOmph WIND IMPORTANCE FACTOR: 1.0 WIND EXPOSUR`: C INT. PRESSURE COEFFICIENT: Q. I5 ENCLOSURE CLA551FICATION: ENCLOSED COMPONENTS .AND CLADDING: -ROOF LOAD (ZONE #1): +21.41-43.8 P51' -ROOF LOAD (ZONE #2): +21:4/-G 1.7 P5F -ROOF LOAD (ZONE #3): +21.41-97.4 PSF -WALL LOAD (ZONE #4): +455/-49.8 P51' -WALL LOAD (ZONE #5): +4G.3/-58.5 P51' -WALL LOAD (2,0NE #405): +45.9/-54.2 P5F 7. FLOOR DESIGN JVE LOAD: 125 P51' 8. FLOOR DESIGN DEAD LOAD: 12 PSF 9. ROOF DESIGN LIVE LOAD: 20 PSF 10. ROOF DESIGN DEAD LOAD: SELF WEIGHT 11. WALL DE51GN LOAD: 8 P5F 12. COMBINATION LOADS: AS PER A5CE 7-1 O 13. SEISMIC USE G-=P: B 14. BUILDING CATEGORY: 1 1.5. BUILDING.00CL FANCY: STORAGE.- NON H.A5ITABLE I G. CON5TRUCTiOt•: TYPE: V B 17. ALLOWABLE FLOORS: I 18. EXTERIOR WALL FIRE RATING: 0 19. DESIGN OVERHANG: 8 INCH 20. DESIGN MEET5 NTERNATIONAL BUILDING CODE 2C09 6• FLORIDI BUILDING CODE 21. THE CONTRACTORIMANUFACTURER MUST COMPLN %MTH THE FOLLOWING CODES: 2014 FBC, 5th Edition 2011 NEC 2014 Florida Fire Prevention Code THESE BUILDINGS A E EXEMPT FROM THE THE F5C ENERGY CODE IN ACCORDANCE WITH 101.5.2 SITE IN5TALLED ITEM5: I . THE COMPLETE FOUNDATION SUPPORT AND TIE -DOWN SYSTEM. 2. RAMPS, STAIRS AND GENERAL ACCESS TO THE BU LOW-G. 3. ELECTRICAL 5E ACE HOOKUP (INCLUDING FEEDERS) TO THE BUILDING. 4. ROOF DRAJNAC'_ 54AL COMPLY WITH F.B.C. 1503 AND R318 G NOTE: THI5 UST DO::5 NOT NECESSARILY LIMIT THE ITEM5 OF WORK AND MATERIALS THP T MAY BE REQUIRED FOR A COMPLETE INSTALLATION. ALL 5.TE RELATED ITEMS ARE SUBJECT TO LOCAL JURISDICTION APPPOVAL. Single Wide Metal Master Plan Lark Builders 409 Dixon Street Vidalia, GA 30474 Designed By: Project No. O.R.H. 12EN224 Checked By: Date: CJ-.A. 04/09/12 Approval Stamps: ` I ���� J ....Tun iii {/' S •To Build0,', CODE REVIEW Professional Service lndustrfes 1748 33rd S".f t Orlando, Florida 328_+e IPlan Reviewer. tYlliam f Neary, III [cc C 5185040 t LA BU011406 { FL SMI-70, SMP51 l i l ' i Haney Ass tes, Inc. J Certificate oflcuthorization I l No.2712.1 `,`ttttlRrr�rrr' I, OQ� 9d �F.L �1. y S s go' STAT OF �� is�ONAL �.`�� i. I rylrnnitlt wv � Sheet Num ber: ELECTRICAL NOTES: PSI APPROVAL 2015-05-24 I . WHEN AIR CONDITIONING 15 INSTALLED IN THI5 BUILDING, IT SHALL BE THE RESPONSIBILITY OF THE'HVAC CONTRACTOR AND ELECTRICAL CONTRACTOR TO VERIFY WIRE AND BREAKER SIZES FOR ACTUAL HVAC UNIT(5) INSTALLED ALL WIRING TO BE 1N ACCORDANCE WITH THE NATIONAL ELECTRIC CODE LATEST EDITION. 2. FLEXIBLE CONDUIT FOR LIGHT FIXTURES. 3. EACH CIRCUIT 15 TO HAVE CONTINUOUS SOLID COPPER INSULATED GROUND WIRE CONNECTED TO EQUIPMENT GROUND BAR IN THE MAIN DISTRIBUTION. PANEL 4. EQUIPMENT GROUND BAR IN MAIN DISTRIBUTION PANEL 15 TO BE GROUNDED TO MINIMUM I O-a COPPER CLAD EARTH DRIVEN ROD WITH GROUNDING CLAMP APPROVED FOR DIRECT BURIAL. 5. ALL CONDUIT TERMINATION'S OF I' OR LARGER ARE TO HAVE PLASTIC INSULATED BUSHINGS. G ALL ELECTRICAL WORK 15 TO BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC), LIFE SAFETY CODE (NFPA 10 1). LATEST EDITIONS. 7. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCE551BLE DISCONNECTS ADJACENT TO THE EQUIPMENT SERVED. A UNIT SWITCH WITH A MARKED -OFF' POSITION THAT 15 PART -OF THE HVAC EQUIPMENT SHALL BE PERMITTED AS THE DISCONNECTING MEANS ONLY WHERE OTHER DISCONNECTING MEANS ARE AL50 PROVIDED BY A READILY ACCESSIBLE CIRCUIT BREAKER. 8. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING OF THE MAIN BREAKER MUST BE DF51GNED AND VERIFIED AS BEING IN COMPLIANCE WITH 5EC. 110-9 OF THE NEC BY A LOCAL ELECTRICAL CONSULTANT. 5 THE MAIN ELECTRICAL PANEL. FEEDERS, POWER HOOKUP TO BUILDING (INCLUDING ALL DISCONNECTS, OVER CURRENT DEVICES, PANELS, GROUNDING, ETC.) 15 DESIGNED BY OTHERS, SITE INSTALLED, SUBJECT TO LOCAL JURISDICTION APPROVAL I O. ALL WIRES TO SWITCHES AND OUT LETS TO BE (t 12 AWG THHN AND WILL MEET THE COLOR CODE REQUIREMENTS SET FORTH IN THE NFPA 70, NATIONAL ELECTRICAL CODE. i i . ALL ELECTRICAL OUTLETS SHALL BE GFCI IN ACCORDANCE WITH ARTICLE 1210.8(A)(2) NEC-08. Electrical Symbol Key GFCI Duplex Receptacle 120V 10 o Incandescent Light w/ (1)-60w Bulb 1131 Junction Box $ switch WP Weatherproof $R Switch w/ Receptacle Outlet 120v 10 ' Haney Associates, Inc. Engineering &6 Construelion Planning P.O.aa3i%Six M94&C. Z96n- Phoac864i46.7600 WINDOW HEIGHT. LOCATION AND QUANTITY MAY VARY MAX AND AND ARE OPTIONAL. I I tl in P.T. 3/4' T4G I' OOP SHEATHING SEE VARIOUS END ' O WALL FRAMING \` 3ECTION5 FOR WALL 1! AND WINDOW FRAMING. w / J $Pry i" MIN., GO' MAX. WIDTH F ' G'-8' HEIGHT DOOR, ;CATION MAY VARY. `c Mi Vt.'AL5TUDS 5Pa 'ED AT 24' O.G. MAX. t i r SEE k. iRI0U5 END WALL FRAY I G 5ECTIONS FOR WALL AN ' DOOR FRAMING: ,I i i OPTIONALELECTRICTO-' WP r\ %-32'MIN., GO' IAX. WIDTH EACH UNIT FIELD \�/ BY G'-8' HEIGr DOOR CONNECTED FROM LOCATION MA VARY. EXISTING POWER 50UPCETO UNIT 50-9 MAXIMUM BUILDING LENGTH NOTES: • ALL ELECTRICAL EQUIPMENT 510WN 15 OPTIONAL AND LOCATIO' 3 MAY VARY. These plans Were designed in accordance 2014 FBG 51h Edition 2011 NEC 2014 Flor(daFire Prevention Code For Wind Speed 160 mph, Exposure C Typical Floor Pian 5CALE: 1/4'= P-O° Single Wide Metal Master F Ilan Lark Builders 409 Dixon Street Vidalia, GA 30474 Designed By: Project No. O:RH. 12EN224 Checked By ' Date: C.L.A. 04/09/12 �pco Infonwlion f� ` oBuildOn CODE REVIEW Prolesslonal Service Industries 1748 33rd Street Orlando, Rorida 32839 Flan Reviewer. William E. Neary, III Icc o slesm LA M190406 FL SMI.79, SMP-51 Haney Associates. Inc. i ificate of Authorization `t,tntut,,r , •� GqC R. �* No 58 401710D 70NA%- `.�. S1.1 • PSI AP'ROVAL 2015-05-24 SKID LAYOUT AND FLOOR FRAMING SCHEDULE 125 psf Live Load (2 Skid) 125 psf Live Load (3 Skid) Width! Joist size&Spacing A B Widthl Joist size&Spacing A I g 6'-0" j 2x4's @ 16" O.C., Max. 15" 42" 6'-0" 2x4's @ 16" O.C., Max. 12" 24" 2x6's @ 16" O.C., Max. 118" 60" 8'-0" 2x6's @ 16" O.C., Max. 16" 1 32" 10'-0" j 2x6's @ 16" O.C., Max. 24" 72" 10'-0" 2x6's @ 16" O.C., Max. 20" 40" 11'-0" ! 2x6's @ 16" O.C., Max 24" 84" 11'-0" j 2x6's @ 16" O.C., Max. 22" 44" 2x6's @ 16" O.C., Max. 28" 84" 11'-8" 2x6's @ 16" O.C., Max. 24" 46" 1IT-0" j 2x8's @ 16" O.C., Max. 36" 84" 13'-0"' 2x! 8s @ 16" O.C., Max. 26" 52" 13'-8" ( 2x8's @ i6" O.C., Max. 40" 84" 13'-8"! 2x8's @ 16" O.C., Max. 28" 56" NOTES: • FASTENERS WILL MEET THE MINIMUM REQUIREMENT5 FOR ALL STRUCTURAL COMPONENTS AS SET FORTH UNDER FBC 2304.9.1 AND TABLE 2304.9.1 UNLESS dTHERWI5E SPECIFIED. " ALL 5KID5 ARE P.T.-4xG 5.Y.P. #2 OR (2)-P.T: 2xG 5.Y.F. #2 • 0-0' WIDE UNITS MAY USE 2x4 S.Y.P. #3 JOISTS "ALL JOISTS ARE TO BE P.T.-5.Y.P. #2 P.T. SIDE RAIL 1 O MATCH JOIST SIZE. SEE FRAMING SCHEDULE FOR SIZE5. LE FOR 015T SIZE 1 1 1oil 50'-0' MAXIMUM BUILDING LENGTH Typical 2 51ad Floor Framinq Plan SCALE: 1/4'=1'-O° Haney Associates, Inc. Engineering &c Construction Planning �{ P.O. Rox349, St. 5t0S S.0 29582-Ph—M -U6.7600 These plans were designed in accordance 2014 FBG 511 Edition 2011 NEC 2014 Florida Fire Frevent ion Code For Wind Speed 160 mph, Exposure C EE SCHEDULE FOR J015T SIZE •A• °B' 'A EE SCHEDULE FOR J015T SIZE K LAJ r, P.T. SIDE RAIL TO MATCH J015T SIZE, SEE FRAMING SCHEDULE FOR J015T 51ZE —P.T.-4xG 5.Y.P. #2 or 4'-0' or. E-0' (2)-P.T.-2xG 5.Y.P. #2 SKIDS OpUonal.Po rJt 50' 'MAXIMUM BUILDING LENGTH �� InfoW0, a .ToBuildOn CODE REVIEW Prolesslonal Service Industries 174833rdstreet Orlando, Ronda 32839 Plan RevIe r. wliliam E. Neary, III ICC C 5185040 LA K000408 FL SMI-79, SMP51 m ID I Haney Associates, Inc. Certificate of Authorization No. 27124 `tttnttr,, R. -CE*'N. No. 8 : # Typ1c 3 5kid Floor Framinq Plan SCALE: 1/4"=1'-0' Single Wi le Metal Master Plan PiRi-No. L irk Builders FCh 12ENn4 4 19 Dixon Street Date VI ialia, GA 30474 04/D9/12 - (;<1 v Q SS; 70NALt .. Sheet Number: S 1.2 • PSI APPROVAL 2015-05-24 32' - 20g2. METAL WALL STUDS SEE PLAN VIEW FOR SPACING SEE FRAMING 5CHEDULE SKIDS MAY P.T.-4xG 5.Y.P. H2 OR'(2)-P.T: 2xG 5.Y.P. N2 319 - 20ga. METAL SOLE PLATE, FOR JOIST SIZE i ; CONTINOU5 W/ 511 Gk4' LAGS ATTACH EACH STUD TO SOLE j i AT I G' O.C., Max. PLATE WITH (2) ! I O SELF t I .T. 3/4' T4G FLOOR DRILLING GRABBERSCREW5 I SHEATHING (1) INTO EACH FLANGE. 5ENCO K26 (OK EQUAL) NOTCH SKIDS IVx I& NAILS AT 12- O.C., RdW5 FOR EACH FLOOR J015T SHALL BE 1. 5' FROM EDGE, J it _ _________ r STAGGER ROW5 G' FOR (2)-P.T.-S.Y.P:-2xG'sSKIDS, ' 2. BLOCKING BETWEEN START PATTERN WITHIN G" SKIDS, FASTEN TO END OF EACH END OF SKID 2<4 BLOCKING BETWEEN ' 5K( FASTEN W1 _ J015T W/ (3)-0. 12Ox3" I _ _D5, ,2){?.120x3' NAILS AT NAILS AT 12' O.C. EACH j SIDE, STAGGERED. 12' O.C., STAGGERED. �y 1 15KIDEFLOOR FRAMING DETAIL �y L[ 9END J015T F4AMING.DEfAIL I . sc sla= i .a 1.� SC ALE: 1.5•= ram SKIDS MAY BE P.T.-4xG 5-Y.F. #2 OR(2)-P.T: 2xG 5.Y.P 92 ATTACH J015T TO SKID WITH 5/ 1 Gx4' LAG SCREW OR (2) SIMPSON H-3 (OR EQUAL) AT EACH END Of J015T; 5EE FRAMING SCHEDULE FOR SIZE. NOTE: ATTACH END JOISTS 70 SKID WITH (2)-5/ 1 G' tW LAG SCREWS [OR (4)-0. 13 1x4' GUN NAILS] AND A 51MP50N H-3 (OR EQUAL] AT EACH END OF JOIST. �� TYPICALSKI D TO / 1,IOIST CO.W EZION DETAIL lip SCALL: ya•=..o 12' LAP SPLICE FA5TENED W/ (G)-5/1 Gx4' LAGS P.T.-4xG 5.Y.P. (OUTER FACE). (3)-5/ 16 x4' N2 5KID5 LAG5 (INNER FACE), (9) LAG 5CREW5 TOTAL. 3'W SPLICE PLATE ON 3 of 4 SIDES OF JOINT, FASTEN (2)-P.T. 2xG EACH PLATE WI (5)-5ENCO 5.Y.P. k2 SKIDS K25 (OR EQUAL) NAILS EACH SIDE. TYPICAL SKID SPLICING DETAIL �■ lnfinnullion �r To Build On CODE REVIEW Frofessiwal Service Industries 1748 33rd Street Orlando, Florida 32829 Plan Reviewer. Mi llam E. Neary, (11 ICC 0 5185040 LA NUO0406 FL SMI-79, SIAP-51 Haney Associates, Inc. j Certificate of Authorization i No.27124 �pK R. y� ATE OF I DNAI ��.•�• lnnrllt { These plans were designed in accordance wit h: �— Sheet Number: i 2014 FBC, 51h Edition Single Wide Metal Master Plan Designed By: Project No. f Haney Associates Inc.R.H. 12EN224 1 >' ( zo1, NECr1Ec Lark Builders ` Engineering &c Constrnction Planning rs� i 2014 Florida Fire Prevention Cade � 409 Dixon Street tea . P.O.Bot3/8,9a; iMSC 2%n-Phaec8644467600 1 For Wind Speed 160 mph, Exposure C Checked 04I0te: Vidalia, GA 30474 4 _r , • PSI APPROVAL 2015-05-24 ROOF FRAMING SCHEDULE Wall Framing at 24" o.c., Max. Width Rafter and Brace Size and Spacing: 6'-0" ASIS SSMA S 350S162-43 @ 24" O.C. Max. 8'-0" ASIS SSMA_S 350S162-43 @ 24" O.C. Max. 10'-0" ASIS SSMA_S 350S162-43 @ 24" O.C. Max. 11'-0" ASIS SSMA_S 350S162-43 @ 24" O.C. Max. 11'-8" ' ASIS SSMA_S 35OS1.62-43 @ 24" O.C. Max. 13'-0" ASIS SSMA S 350S162-43 @ 24" O.C. Max. 13'-8" ASIS SSMA_S 350S162-43 @ 24" O.C. Max. SCHEDULE AND ROOF FRAMING NOTES: • ROOF FRAMING SHALL BE SPACED TO UNE UP DIRECTLY OVER THE WALL STUDS FOR PROPER LOAD TRANSFER AND STRAPPING. • ROOF DRAINAGE SHALL COMPLY WITH F..B.C. 2010 1 503 AND R318.G • FASTENERS WILL MEET THE MINIMUM REOUIREMENT5 FOR ALL -STRUCTURAL COMPONENTS A5 SET FORTH UNDER F13C 2304.9.1 AND. TABLE 2304.9. 1 UNLE55 OTHERWISE SPECIFIED. • RIDGE MAY RUN IN THE SHORT DIRECTION TURNAROUND' OR'VAULTED" STYLE WITH A MA>JMUM GABLE END OF 30-0' AND 51DE WALL5 THAT VARY G'-O' TO 13'-8' OR THE LONG DIRECTION 'STANDARD' WITH GABLE EN05 THAT VARY 9-0' TO 131-V WITH A MAXIMUM SIDE WALL LENGTH OF 50-0. • ATTACH ROOF FRAMING TO TOP PLATE OF WALL FRAMP,IG WITH 13UILDDC 10-1 Gx I TEK5 PANHEAD SCREWS WITH d3 DRILL POINT AT G` O.G. �, 50-0' MAXIMUM BUILDING LENGTH - 30'-9 MAX. FOR VAULTED_ ROOF Raney Associates, Inc. Engineering & Construction Planning PA. Hot ate, sa N11I4S.C.11M. Phoac864646.7600 Typical Roof Framing Plan SCALE: 1/4'=1'-0' These plans were designed in accordance with: 2014 FBC, 51h Edition 2011 NEC 12014 Florida Fire Prevention Cade For Wind Speed 160 rnph, Exposure C 209a. METAL RAFTERS BRACING, SPACED AT O.G., MAX. UNE UP TER5 TO LAND ON WALL IDS FOR LOAD TRANSFER Single Wide Metal Master Plan Lark Builders 409 Dizon Street Vidalia, GA 30474 Designed By: Project No. O.R.H. 12EN224 Checked By: Date: C.L.A. 04/09/12 �i /nfornudion .TnBuiidOn CODE REVIEW Professional Service Indt,� Was 1746 33rd Street Orlando, Rodda 32839 Plan Reviexer: William E. ll a /, III ICC 6 5185040 LA MJ00406 FL SMI.79, SMPZI Haney Associates, iro. Certificate of Authorization No. 27124 . R. �. QQ •�%CFN 4 5858 * No. 645 STATEF� %CAS -f4-ORI� NALt S 1.4 a Mw PSI APPROVAL 2015-05-24 5EE ROOF FRAMING 5CHEDULE FOR RAFTER AND BRACING 51ZE5 AND SPACING ATTACH ROOF FRAMING TO TOP PLATE OF WALL FRAMING W:TH B.UILDEX 10-1Gx1 TEK5 P6.NHEAD 5CREW5 WITH S3 D JLL POINT AT G' O:C. 2 1/2'x IJ2'CORRUGATED �, i i ROOF PANELS FASTENED ✓2 2AT METAL COLLAR TIE, 4'-0' 3/2"-20ga. METAL STUDS WITH 1/4'-.I 4 x 3/4' HWH LONG,, ATTACH WI (2) # 10 5EIF 5PACED AT 24" O.C. MAX. - DRILLING GRABBER 5CREW5 EACH 51DE TRAXX/ I AT G" O.C. { - i 5EE ROOF FRAMING 3vz -20ga. METAL STUDS L! OVERHANG OPTION DErAII 5CHEDULE FOR RAFTER5 5PACED AT 24' O.C. MAX. I • sour: 3 a =r a i 3vz-20ga. METAL BRACE AT ne z O 5EE ROOF FRAMING 3'-0' ABOVE FINISHED FLOOR, p 5CHEDULE FOR FASTENING ATTACH TO EACH 5TUD W/ (2) n REQUIREMENT5 # 10 5ELF DRILLING GRABBER. io r 5CREW5, (1) INTO EACH FLANGE ��. I, fi S. or nalton ZBuildOn O 5EE 51.2 FOR 5KID COR TC PAcH PLA EOofOF WALL INFRAMW I/2° G 2 1 /2'x RUGATED AND FLOOR FRAMING PANEL5 (FA5TENED W/ #8 x us'H BU1LDEx 1 O- 16a I TEKS CODE REVIEW I,v2 WOOD 5CREW AT G' P:-NHEAD 5CREW5 WITH #3 17483Professional dStreervleelndvstrles I 1 f74833rd Street i O.C. (OR EQUAL) , �� D -ILL POINT AT G' O.C. Orlando, Florida 32839 Plan Re i—.. William E. Meary, III yAR1E5, 6'-O" to 13'-8' ILC S 518504a_' �_ LA 11004% FL SMI-79, SMP-51 Typical Frame Section �p 5EE ROOF FRAMING Haney Associates, Inc_ 5CALE: I14'-1'-0' 5CHEDULE FOP PAFTERAND i I Certificate of Authorization BRACING 51ZE5 AND 5PACING I No.27124 j IRlr�r,r� _ -Vz-20ga. METALSTUD5 ! ! :� 5PACED AT 24' O:C. MAX. �Qe '� No. 58 L2 \OVERHANG OPTION DE 41L % 0 STATE OF ' (�•���QRlO i S � ,I These plans were designed in accordance with: —� : j Sheet Number: Single Wide Metal Master Plan DesigetedBy: Projectile. Hane Associates Inc- 2014 FBC Slh Edition O.R.H.12EN224 ' Y 2011 NEc Lark Builders e Engineering 8c Construction Planning 2014 Florida Fire Prevention Code J P.O. BU348,ShNft. S.C. 29682-Ph-8644467600 409 Dixon Street. Checked By: Date: x' I For Wind Speed 160 mph, Exposure C Vidalia, GA 30474 1 CLA, 04i09/12 A -F, a U PSI APPROVAL 2015-05-24 M2' METAL BRACE AT N-O' ABOVE FINISHED FLOOR, ATTACH TO EACH STUD Wl (2) k 10 SELF DRILLING GRABBER 5CREW5, (1) !NTO EACH FLANGE %7 METAL BRACE AT 3-0' ABOVE FINISHED FLOOR, ATTACH TO EACH STUD W/ (2) A,10 SELF DRILLING GRABBER 5CRE`.NS, (1) !IJTO EACH FLANGE End Wall framing Option SCALE: 1/4"=1'-0' VARIES, G'•O" to 13'-8' End Wall framinq Option SCALE: 1 /4'=1'-0" C' x 1 /L- L UKKU(sA I CU KUvr 15 FASTENED WITH 1/4'-14 x 4" HWH TRAM I AT G" O.C. > - 20ga. METAL BRACING, — \CH EACH END TO STUDS W/ I 10 5ELF DRILLING GRABBER EWS, (1) INTO EACH FLANGE DTE THAT THIS BRACING 15 ]RED ON 51DE WALLS A5 WELL F11 SIDES OF EACH CORNER)) 51.2 FOR 5KID AND FLOOR — FRAMING WALL OPENING FOR: SIDE WALL.5 ARE TO BE FRAMED SIMILAR TO THOSE SHOWN HERE FOR ENDWALLS — 2-1/2' x 1/2" CORRUGATED ROOF — PANELS FASTENED WITH 1/4'-14x 314" HM-I TRAM AT G" O.C. 3y - 20ga. METAL BRACING. — I ATTACH EACH END TO STUDS W/ (2) # 10 SELF DRILLING GRABBER SCREWS, (1) INTO EACH FLANGE [NOTE THAT THIS BRACING 15 REQUIRED ON SIDE WALLS AS WELL (BOTH SIDES OF EACH CoRNER)) 51.2 FOR 5KID AND FRAMING VARIES, G'-O" to 13'-& End Wall Frammq Option SCALE: 1/4'= P-O' VARIES, 0-0' to 13'-& End Wall Frammq Option Vz METAL BRACE AT 3'-0' ABOVE FINISHED FLOOR, ATTACH TO EACH STUD W/ (2) N 10 5ELF DRILLING GRABBERSCREW5, (1) INTO EACH FLANGE 3V2' METAL BRACE AT 3'-O° ABOVE FIN15HED FLOOR, ATTACH TO EACH STUD W/ (2) If 10 5ELF DRILLING GRABBER SCREWS, (1) INTO EACH FLANGE NOTE THAT THIS BRACING 15 REQUIRED ON SIDE WALLS AS WELL (BOTH 51DF-5 OF EACH CORNER) S& Information I� • -To, e"m....w. • coau.. wmm CODE REVIEW Professional Service Indus0es 1748 33rd Sfreet Orlando, Florida 32839 PW Revies,•er: Will.. E. Neary, III ICC 5 5185040 LA #000408 FL SMI.79, SMPSt Haney'Associates, Inc. Certificate of Authorization No. 27124 (ttnurrlrr 1 \GlC R. *: No. 58 :*=1 ASTATE OF c40RI D '%S�QNAG rrrru itttt�� Y-- hese plans were designed in accordance with: Sheet Number: 1 Single Wide Metal Master Plan Designed By: PmjectN0. F2011 014 FBC, 5t'' EditionU.&I- 12F.PI224 Haney Associates, Inc. NEC Lark BuildersEngl 2eeri]ng &c Constructilon Planning 014 Florida Fire Prevention Code 409 Dixon Street ■P.O. Boz34S, �AOIh S.0 Mn- Phuer.864-U&7600 or Wind Speed 160 mph, Exposure C Checked By- Date Vidalia, GA 30474 cam. 04/09/12 7 of 7