HomeMy WebLinkAboutFBC CONSERVATION CODE_ Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
r T Fort Pierce, FL 34982
772-462-2165 Fax 772462-6443
FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method
Date: 11 �0�% ZO t� Permit it
Jw�
NOV - 6 2018
Permitting Department
. LucjtCounty, FL
Contractor. ">R V_ darkcY
Construction: Oost Construction Test
Address: 9y1i C-o6612cj�O+ne.
❑ Rough -in Test 1—_O r+ p erce, FL
1Jr.
34945
Test Conditions:
Date: 1 l Dlo Zv 1
Time: 11% 31 &A,\,
Indoor Temperature (F): '74'0
Outdoor Temperature (F): all °
Floor Area (ft2):
Primary Location of Supply Ductwork
Primary Location of Return Ductwork
24 3 Z
0-4iG
in A-frCox-
Total Leaka a Test Outside
Duct Leakage: efault o Prop. Leak Free ❑ Proposed On =
Test Pressure: 25 (Pa)
Baseline Duct Pressure (optional) (Pa)
Duct Press. (Pa)
Flow Ring
Installed
Fan Press
Pa
Flow (cfm)
Results: klass o Fail
Total Leakage (cfm): SG
Total Leakage per 100 sgft 0.0 2 3
CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgfL
Testing Company
Company Name: S �N� �� Address:
I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with P Edition FBC Energy Conservation requirements in accordance with
Section R403.2.2.
Signature:
Printed Name: fy�U�(' V 1-r n License/Certificate # _ _ 2 a V5 (o
6..
Planning & Development Services
_ - Building & Code Regulation Division
2300 Virginia Ave, Rm 201
• - Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
RECEIVED
NOV - 6 2018
Permitting Department
St. Lucie County, FL
Date: i 1zOCoLM18 Permit #: , :ZI2—— / 7
Contractor: I>Z �lor-�-din
Job Address: '3L 17 Coh\ojest-oe Fot-� ?�erce . FL_ 3t4cl45
Construction: New Construction — Complete ( ) Existing —After Addition
House Infiltration Test Results
CFM (50) = p a 2 S
Volume = ZO, 2_ 71
ACH (50) = CFM (50) x 60 / Volume = S
Passing results must be & ACH (50) or less
SLC Climate Zone 2
Test Date: 0. 11 f/d ��Zoi�
Mechanical Ventilation required less than 5 ACH
P} j Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code -official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company c
Company Name: c��`1�i��G Address:
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accoLdance with Section R402.4.1.2 Climate Zone 2.
Signature: �I/p,�A�/GL✓"'��
Printed Name: -RI cJy� ol.t�cx i V 10. ('4A
License/Certification #: 2 l` Q V 5 (p