Loading...
HomeMy WebLinkAboutFBC CONSERVATION CODE_ Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 r T Fort Pierce, FL 34982 772-462-2165 Fax 772462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: 11 �0�% ZO t� Permit it Jw� NOV - 6 2018 Permitting Department . LucjtCounty, FL Contractor. ">R V_ darkcY Construction: Oost Construction Test Address: 9y1i C-o6612cj�O+ne. ❑ Rough -in Test 1—_O r+ p erce, FL 1Jr. 34945 Test Conditions: Date: 1 l Dlo Zv 1 Time: 11% 31 &A,\, Indoor Temperature (F): '74'0 Outdoor Temperature (F): all ° Floor Area (ft2): Primary Location of Supply Ductwork Primary Location of Return Ductwork 24 3 Z 0-4iG in A-frCox- Total Leaka a Test Outside Duct Leakage: efault o Prop. Leak Free ❑ Proposed On = Test Pressure: 25 (Pa) Baseline Duct Pressure (optional) (Pa) Duct Press. (Pa) Flow Ring Installed Fan Press Pa Flow (cfm) Results: klass o Fail Total Leakage (cfm): SG Total Leakage per 100 sgft 0.0 2 3 CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgfL Testing Company Company Name: S �N� �� Address: I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with P Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: fy�U�(' V 1-r n License/Certificate # _ _ 2 a V5 (o 6.. Planning & Development Services _ - Building & Code Regulation Division 2300 Virginia Ave, Rm 201 • - Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method RECEIVED NOV - 6 2018 Permitting Department St. Lucie County, FL Date: i 1zOCoLM18 Permit #: , :ZI2—— / 7 Contractor: I>Z �lor-�-din Job Address: '3L 17 Coh\ojest-oe Fot-� ?�erce . FL_ 3t4cl45 Construction: New Construction — Complete ( ) Existing —After Addition House Infiltration Test Results CFM (50) = p a 2 S Volume = ZO, 2_ 71 ACH (50) = CFM (50) x 60 / Volume = S Passing results must be & ACH (50) or less SLC Climate Zone 2 Test Date: 0. 11 f/d ��Zoi� Mechanical Ventilation required less than 5 ACH P} j Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code -official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company c Company Name: c��`1�i��G Address: I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accoLdance with Section R402.4.1.2 Climate Zone 2. Signature: �I/p,�A�/GL✓"'�� Printed Name: -RI cJy� ol.t�cx i V 10. ('4A License/Certification #: 2 l` Q V 5 (p