HomeMy WebLinkAboutPRODUCT APPROVAL STRUCTURAL COMPONENTSFlorida Building Code Online Page 1 of 2
RCRt0Ar0A;M%TNT OF
•►
13CMHome I Log In I User Registration I Hot Topics I Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Lima I Search
Fllida //��
Product Approval
• USER: Public User
SF �'
Product Approval Menu > Product or Application
Search > Aoolication List > Application Detail
IL #
FL17147-R2
Application Type
Revision
Code Version
2017
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived O
Product.Manufacturer Huber Engineered Woods LLC
Address/Phone/Email 10925 David Taylor Drive
Suite 300
Charlotte, NC 28262
(704) 548-5442
kurt.koch@huber.com
Authorized Signature Kurt Koch
kurt.koch@huber.com
Technical Representative Ken W. Hix
Address/Phone/Email 1446 Hwy 334
Commerce, GA 30530
(706)336-3041
ken.hix@huber.com
Quality Assurance Representative Walker Campbell
Address/Phone/Email 1446 Hwy 334
Commerce, GA 30530
(704) 562-1053
walker.campbell@huber.com
Category Structural Components
Subcategory Products Introduced as a Result 'of New Technology
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity IAPMO Uniform Evaluation Services LLC.
Quality Assurance Entity PFS Corporation
Quality Assurance Contract Expiration Date 10/01/2018
Validated By IAPMO Uniform ES
Certificate of Independence FL17147 R2 C01 Cer-tlflcate of Indeaendence fgr Eva',,-"--d
Standard and Year (of Standard) Standard ���� Copy —
Referenced Year
ICC-Evaluation Service AC310 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Approved Evaluation Entity
https://www.floridabuilding.orglpr/pr app dtl.aspx?param=wGEVXQwtDgvCo3Eapi lBd... 2/28/2018
N
Florida Building Code Online Page 2 of 2
" P�iiduit Approval"Method' `- -- - ` - "-'--Method 1 "Option-C "
Date Submitted 10/20/2017
Date Validated 10/20/2017
Date Pending FBC Approval
Date Approved 10/25/2017
Summary of Products
FL #
I Model, Number or Name
Description
17147.1
ZIP System (R) Wall Sheathing
ZIP System (R) Wall Sheathing
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17147 R2 II ZIP Sheathino Install Manual-2013.pdf
Verified By: ICC Evaluation Service, LLC
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party:
Design Pressure: N/A
Evaluation Reports
Other: limited to structural aspects of panel
FL17147 R2 AE ESR-1474 (2).Ddf
FL17147 R2 AE ESR1474.odf
17147.2 ZIP System (R) Wall Sheathing Combination Wall Sheathing and Water Resistive Barrier
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17147 R2 II FL17147 ZIP Sheathina InstallManual-
Approved for use outside HVHZ: Yes 2 10 3.pdf
Impact Resistant: No Verified By: IAPMO Uniform Evaluation Services LLC.
Design Pressure: N/A Created by Independent Third Party:
Other: Evaluation Reports
FI-17147 R2 AE E1553 R0544 Huber Engineered Woods
LL .
Back Next
Contact Us :: 2601 Blair Stone Road_ Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA(EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility statement :; Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees Ilcensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public To determine If you are a licensee under
Chapter 455, F.S., please dick hmL.
Product Approval Accepts:
Credit Card
safe "
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3EapiIIBd... 2/28/2018
ZIP SysteV Roof & Wall Sheathing
.-. [NSTALLATI:ON- iULANUAL
-aooF r'.wau weannNo= ,::: ....
FASTER. TIGHTER. ENERGY EFFICIENT.
Contents
02 ZIP System® Sheathing Installation On Roofs
03 ZIP System"" Tape Installation -
Roof Panel Seams
04 ZIP System"' Tape Installation -
Roof Panel Seams (continued)
05 Roof. Covering Installation Instructions
06 ZIP System® Roof & Wall Sheathing Installation
07 ZIP System'' Tape Installation - Panel Seams
ATTENTION: This installation guide Is Intended to provide general
Information for the designer and end user. The following guidelines
will help you safely and properly install the 'ZIP' System° Roof & Wall
wall sheathing. We urge you, and anyone installing this product, to
read these guidelines 1n order to minimize any risk of safety hazards
and to prevent voiding any applicable warranties. This manual is
a general In guide and does not cover every Installation
condition. Proper installation shall be deemed to mean the most
restrictive requirement .specified by Huber Engineered Woods (HEW),
local building code, engineer or architect of record or other authority
having jurisdiction. You are fully and solely responsible for all safety
requirements and code compliance. For additional Information contact
Huber Engineered Woods LLC.
ZIP System" Roof. & Walt Sheathing Safety Guidelines
- Follow all OSHA regulations and any other safety guidelines and safety
practices during installation and construction.
Use approved safety belts and/or harnesses or otherfall protection equipment.
Install ZIP System panels and iape.only In dry conditions and on dry surfaces.
Do not.install in rain, snow, frost or other slippery conditions.
Wear rubber -soled or other high -traction footwear while installing ZIP System
sheathing in a roof application. Do not wear footwear with worn soles or heels.
Ensure the roofing surface Is free from oil, chemicals, sawdust, dirk tools,
electric cords, air hoses, clothing and anything else that might create a
tripping hazard.
Install temporary toe boards along the ZIP System sheathing roof surface.
What Is ZIP Systertf Roof & Wall Sheathing?
ZIP System Roof & Wall sheathing is code -recognized as a wood structural
panel, roofing underlayment (IMES ESR-1473), water -resistive barrier
and air barrier (IMES ESR-1474). ZIP System Roof & Wall sheathing
has a built-in moisture barrier that lets you say good-bye to building paper
or housewrap on the walls and fell paper on the root' Simply install the
panels, tape the seams, and you have a structural wall sheathing, water -
resistive barrier and air barrier or a structural roof sheathing and roofing
underlayment all front one product.
08 ZIP System® Roof & Wall Sheathing - Window,
.Installation Flanged Windows & Brick Mould Windows
09 ZIP System® Roof & Wall Sheathing - Window
Installation Brick Mould Windows (continued) -
10 ZIP System® Roof & Wall Sheathing -
Penetration Openings
11 ZIP System@ Roof & Wall Sheathing
Installation Details
12 ZIP System® Roof & Wall Sheathing
Installation Details (continued)
ZIP System Roof & Wail sheathing can be used with a range of exterior
claddings and roof coverings. Approved wall coverings include brick,
Vinyl, stone, wood fiber cement, wood and cedar shakes, traditional hard
coat stucco and specified drainable EIFS applications, however it is
not recommended for use with adhesively attached EIFS. Approved roof
coverings include asphalt -fiberglass shingles, metal files and panels, day and
concrete tiles, slate and slate -type shingles and. wood shakes and shingles.
Follow all cladding and roof covering manufacturer's installation instructions.
ZIP System Roof & Wall sheathing can be used on buildings of Type
III (Roof Applications ONLY) and Type V construction and construction
permitted under the IRC.
ZIP System1° Roof & Wall Sheathing Includes:
ZIP System sheathing, panels with built-in moisture barrier with preprinted
fastening and. tape guides
- ZIP System tape
Storage and Handling
- . Set panel stack on three supports (stickers) to keep off the ground.
Outdoors, cover panels loosely with waterproof protective material.
Anchor covers on top of the stack, but keep away from sides and bottom
to assure good air circulation.
In high moisture environments, out banding on the panel stack to prevent
edge damage.
ZIP System° Roof & Wall Sheathing Notes and Limitations:
Do not use on roofs with slopes less than 2112.
Do not use abutted against general stone or masonry without providing a
minimum of a 1/2" gap.
Do not install ZIP System tape in temperatures less than 20" F
- ZIP System products are not recommended for manufactured housing
applications that are built under a federal building code administered by
the U.S. Department of Housing and Urban Development (HUD),
Do not use panel edge clips (H-CBps) with ZIP System Roof & Wall sheathing
without expressed written approval from Huber Engineered Woods"
Do not use ZIP System tape to permanently seal around circular roof
projections (plumbing vents, pipes, curved walls, etc.)
Contents (continued)
Wall Coverings
- ZIP System Roof & Wall sheathing should be covered with the finished
roof covering or exterior cladding within 180 days of installation.
- Finished roof and exterior cladding products should be Installed pier
the manufacturer's Installation Instructions.
- Per the recommendation of the Western Red Cedar Lumber Association
and the U.S. Forest Products Laboratory, wood siding should be primed
before Installation.
- When original roofing or claddings are removed and replaced on existing ZIP
System sheathing, the roof or wall should be covered with an additional
roofing underlayment or water resistive barrier prior to installation of the
new finished roofing or cladding.
Note: in cladding systems requiring multiple layers of water -resistive barriers,
like traditional hard -coat stucco, ZIP System sheathing Is intended only to
replace the first layer.
Wet Blown Cellulose Insulation
- In addition to following manufacturer installation instructions, we recommend
a maximum moisture content of the cellulose of less than 25'/o measured at
the inside surface of the ZIP System panel before closing the wall cavity.
Secondary Coatings
Do not apply secondary coatings or treatments to ZIP System Roof & Wall
sheathing panels. With the exception -of the following:
HEW -approved fire resistant coatings. Fire resistant coatings must be
tested and approved by HEW for use with2lP System panels.
Field applied water-soluble borate insecticide or fungicide treatments
applied to the non overlay side of the. panel. See technical tip, `Termite
Treatments on ZIP System Roof & Wall Sheathing," on zipsystem:corn for
more information.
Permeable laminated radiant barrier foil or paint. For a radiant barderfoil or
coating to be considered permeable, it must have an applied permeance of
five perms or greater as tested by the ASTM E 96 wet cup standard. For a
radiant foil, the permeance evaluation would include any adhesive .andlor
backer used to laminate a foil. For a radiant paint/coating, -the permeance
evaluation • Should 'be conducted at the applied thickness of the pairit/coating.
ZIP System Roof and Wall sheathing replaces only the first layer in muftlunderlaymenl'systems.
Edge stpport is nut required by rode afth 12 (3?1f a span. rated) and 519 (40120 span rated) performance category sheathing if the framingc does not exceed 24' o .
and the total load does not exceed 93 psf for 1/2 and 156 psf far. A performance categories. This is based an V180 deflection atteria far total load.
ZIP System® Roof & Wall Sheathing Installation Manual
ZIP System® Sheathing Installation on Roofs
overview: ZIP System Roof & Wall sheathing is composed of. ZIP System panels and ZIP System seam sealing tape. ZIP System° Roof & Wall. Sheathing
panels should be fully installed before the seam sealing tape Is applied. In general, theZIP System roof sheathing panels should be installed from the lowest point
on the roof to the highest. It is at the discretion of the installer whether to apply tape from the top down or from the bottom up. However, working from the highest
sections of the roof and working down will minimize foot traffic on the tape. The following installation steps are presented as:guldelines and a general outline of
the installation process. These are manufacturer installation recommendations —please visit zipsystem.com for a library of flashing and installation details. You are
fully and soleiv resoonsible for all safety requirements. Good construction and safety practices should be followed at all times.
Step 1.
Ensure that the panel surface is dry and clean of -any nails, sawdust, or
other debris or protrusions prior to installing or walking on the panels.
After ensuring compliance with all OSHA and local code safety
guidelines, install ZIP System sheathing panels with the moisture
barrier surface facing outside. The long edge (8') should be oriented
perpendicular to the framing members, and panels should be installed
with the 4edge seams 'staggered a minimum of 24".
1I8' spacing betweensquare edges of all adiacent panels is recommended,
in accordance with industry standards for wood sheathing. (Tongue &
Groove panels are :designed to self -space and do not require manual
spacing.on the 8' edges.)
Step 2.
Ensure that ZIP System panels span at least three framing members and
a framing member supports the entire 4' edge of the panels.
Fasten the ZIP System Roof & Wall sheathing pahel•to the framing
members with -code approved fasteners spaced at the appropriate
edge and intermediate spacing.. it Is the responsibility of the general
contractof to verify proper fastener type and spacing priorto installation.
Apply the fasteners 318" from the panel ends and comers.
An ideal installation would be where fastener heads are flush with the
panel surface. However, due to variations in materials'and limitations
on equipment, this may be difficult to achieve in some situations. It
is not required to tape over oveniriven fasteners unless the fastener
head creates a hole through the entire panel thickness. Please see
the technical tip, "Overdriven Fasteners in ZIP System Roof and Wall
Sheathing; for more information.
Step 3..
Install temporary toe boards as necessary when applying the ZIP System
sheathing panels up the slope of the roof planes. .
8' Panel Edges
10
The unique.edge.profile is
designed to accommodate
incremental panel
expansion and:does not
require inanual,gapping
along the 8' edges.
4' Panel Edges
Maintain 1I8" space
where 4' edges meet:
Unique edge profile is on
8' edges only.
ZIP System" Tape Installation - Roof Panel Seams
Apply ZIP System tape after all ZIP System Roof & Wall sheathing panels are fully fastened to roof framing members. Only ZIP System tape should be used to
sea[the seams of ZIP System panels. Ensure that the panel surfaces are dry and free of any nails, sawdust and other debris, or protrusions. Avoid stepping
on tape in high temperature environments. ZIP System tape Is a contact tape that requires pressure for an adequate seal.
Step 1.
ApplyZIP System tape to every vertical and horizontal panel seam. It is
at the discretion of the installer whether to apply tape from the top down
or from the bottom up. However, working from the highest sections of
the roof and working down will minimize foot traffic on the tape.
Ensure that the tape is centered over the seam within +/- 1/2" to provide
adequate coverage andto ensure that wrinkles in the tape are minimized.
Ensure that tap_ a lengths are continuous across the 8' horizontal edge
of the panels. if splices are unavoidable, create an overlapping splice
of at least 3. Apply moderate pressure onto the surface of the tape. to
ensure a secure bond between the panel and the tape.
Use ZIP.System tape gun or tape roller to apply pressure to the tape
and smooth out any wrinkles.
Take special care to remove any voids and/or trapped air at splice
areas and T joints.
I T I
F rs1 Tape Piece 3" overlap Second Tape Piece
Step 2.
For valley areas of framing, we recommend you -use 6" wide ZIP System
tape. This tape Is wider than panel seam tape and is designed to give you
optimal protection in valley areas.
Starting from the bottom and working your way up, apply one continuous
piece of 6" tape so that the center of the tape is over the valley seam.
Use the. tape gun or tape.roller to apply pressure to the tape to ensure
proper contact with the panel and to eliminate any wrinkles that might
have occurred in the tape. Take special care to seat tape completely
into the valley.
Note:
It is important to pay extra attention to valley taping as water is
directed toward the valleys during rain events.
Self -adhering ice and water barriers may be required by code. ZIP
System tape is not considered a replacement for self -adhering ice
and water barriers: Therefore, when self -adhering Ice and water
barriers are required, they should be Installed in addition to ZIP
System tape.
ZIP System° Roof & Wall Sheathing Installation Manual
04 •
ZIP System" Tape Installation - Roof Panel Seams (continued)
Step 3.
- If 6' ZIP System tape is not available, use two continuous pieces of 3.75"
ZIP System panel seam tape over the entire length of the valley seam,
overlapping the pieces on the valley seem by at least 1".
- Starting from the bottom, install the first piece of tape overlapping the
valley seam by at least 1 ".
- Use the tape gun or tape -roller to apply pressure to the tape to ensure
proper contact with the panel and to eliminate any wrinkles that might
have occurred in the tape.
- Apply the second piece of tape, overlapping the first piece in the valley
seam by 1 ".
- Repeat use ofthe tape gun or roller to make sure the tape is adequately
adhered and tightly pressed into the valley seam.
Note:
It is Important to pay extra attention to valley taping as water is
directed toward the valleys during rain events.
- Self -adhering ice and water barriers may be required by code. ZIP
System tape Is not considered a replacement for self -adhering Ice
and water barriers. Therefore, when self -adhering ice and water
barriers are required, they should be installed in addition to ZIP
System tape.
Step 4.
- To provide temporary weather protection to roof/wall intersections
of dormers or other wood -sheathed projections, apply 2" of the tape
width up the vertical projection from where it intersects with the roof.
The'remaining tape width can be adhered to the ZIP System roof
sheathing panels.
Use the tape gun or tape roller to apply pressure to the tape and smooth
out any wrinkles.
Step S.
- Install ZIP System.tape over hips and ridges by centering the tape over
the peak seam. Apply tape in sufficient length to completely extend. the
length of the hip or ridge.
- Starting from the lowest. point of the hip and working up, press tape into
place keeping tape centered over the hip. Apply moderate pressure
onto the surface of the tape to ensure a secure bond between the panel
and the tape.
- Cut ridge tape as required for ventilation prior -to installing ridge vent.
Step 6.
Tape over toe.board nail holes once the toe boards are removed, working
from the highest toe boards to the lowest.
Fist piece
of tape
V overhp
Second piece
of tape
Roof. Covering Installation Instructions
ZIP System Roof & Wall sheathing is a code recognized sheathing and undedayment and Is approved for use with the following roof coverings:
- .Asphalt -fiberglass. Shingles
- Metal Roofs (shingles and panels)
- Clay Tile
- Concrete Tile
- Slate and Slate -type Shingles
- Wood Shingles
- Wood Shakes
When Installing roof coverings, follow applicable codes and manufacturer's suggested instructions. Some roof coverings require a slip -sheet in addition to
conventional underlayment. Where slip -sheets are required, they should be Installed over ZIP System sheathing panels:
Note. Visit zipsystem.com for updates and installation details.
Asphalt -fiberglass. Shingles
Apply asphalt shingles directly to.ZIP System sheathing, For roofs with a slope of 2/12 or greater but less than 4/12, additional undedayment may be required.
Install asphalt -fiberglass shingles according to applicable codes and manufacturer's installation instructions..
Metal Roof.Coveings
Metal roof coverings may be applied to ZIP System sheathing provided that the roof covering manufacturer's installation Instructions and applicable
codes are followed.
Fasteners used to secure the ZIP System Roof & Wall sheathing panels to supporting framing must be compatible With the specific.metal roof covering
used. Galvanized fasteners shall be used with galvanized roof coverings, aluminum -zinc coated fasteners shall be used with aluminum-iinc coated roof
coverings and 300 series stainless steel fasteners shall be used with copper roofs. Stainless steel fasteners are acceptable with all metal roof types.
In addition, metal roof flashing shall also be made of a material compatible with the specific metal roof covering used. Apply metal shingles on roofs with
slopes of 3/12 or greater.
Clay and Concrete Tile Roof Coverings
ZIP System Roof & Wall sheathing is intended to replace the first layer in a two -layer or multi -layer underlayment system. When installing clay or
concrete tile roof coverings, follow the installation recommendations of FRSA/fRl 07320. Install tile roofs according to applicable codes and manufacturers
installation instructions.
Slate and Slate -type Shingles
Apply slate anti slate -type shingles on roofs with slopes of 4/12 or greater. Install slate and slate -type shingles according to applicable codes and manufacturer's
installation instructions.
Wood Shingles
ZIP System Roof & Wall sheathing is intended to replace the first layer of undedayment required by the 18C and/or the IRC. Additional layers of undedayment
may be required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater. Install wood shingles according to
applicable codes and manufacturer's Installation Instructions.
Wood Shakes
ZIP System Roof 8 Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of underlayment
may be required by code depending on the local climate. ZIP System roof sheathing is not to be construed as a replacement for intedayment. Apply wood
shakes on roofs with slopes of 4/12 or greater. Install wood shakes according to applicable codes and manufacturer's installation instructions.
ZIP System? Roof & Wall Sheathing Installation Manual
ZIP System® Sheathing Installation on Walls
Overview: ZIP System Roof & Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape. ZIP System° Roof & Will Sheathing
panels should be fully installed before the seam sealing tape is applied. The following installation steps are presented as a general outline of the installation
process. These are manufacturer installation recommendations —please visit zipsystem.com for a library of flashing and installation details. You are fully and
solely responsible for all safety requirements. Good construction and safety practices should be followed at all times.
Step 1. Install ZIP .System Roof & Wall sheathing panels positioned
with the water -resistive barrier facing outside. The panels may
be installed with the long side of the panel oriented either
horizontally or vertically to the framing members. Walls that are
designed to resist lateral shear forces and sheathed with wood
structural panels typically require solid framing or blocking behind
all panel edges. If oriented horizontally, block horizontal joints if
wall is designed for bracing or as a shear wall.
1/8" spacing_ between .square edges of all adjacent panels is
recommended in accordance with Industry standards for wood
sheathing installation.
6' Panel Edges Panet Edges V Panel. Edges
1/8° 11B'
c,
The unique edge profdeAs
' Maintain 1.18" space where
designed to accommodate
Spanal edges meet 4'
Incremental Panel
panel edges. Unique edge
expansion and does not
profife:does not provide
require manual gapping
the full-1/8" recommended .
along the a' edges.'
space in this sftuafion."
Step 2. Fasten the panels to the framing members -with code approved
fasteners. Space fasteners W o.c. along supported edges and 12"
o.c. at intermediate supports, unless otherwise specified by local
code. or the designer of record. it Is the responsibility of the general
contractor to verify proper fastenertype and spacing prior to
installation. Apply the fasteners 3186 from the ends and corners.
An ideal installation would be where fastener heads are flush with.
the panel surface. However, due to variations in materials and.
limitations on equipment, this may be difficult to achieve in some
situations.. It is not required to tape over overdriven fasteners
unless the fastener head creates a hole through the entire panel
thickness. Please see the technical tip "Overdriven Fasteners in
ZIP System Roof and Wall Sheathing; on zipsystem.com for
more information.
1!8"
5
Maintain 1/8" space
where 4' edges meet
Unique edge profile is on
V edges only.'
-.... -_._._ Q7.
ZIP System'" Tape installation - Wall Panel Seams
Apply -ZIP System'tape after all ZIP System Roof & Waii.sheathing panels are fully fastened to wall -framing members. Only ZIP System tape should be used
to seal the seams of ZIP System panels. Ensure that the panel surface is dry and free of sawdust and dirt prior to taping. ZIP System tape Is a contact
tape that requires pressure for an adequate seal.
Step 1. Tape all seams using ZIP System tape. Ensure that the tape
Is centered over the seam within +/- 1/2' to provide adequate
coverage and that wrinkles in tape are minimal.
Use the ZIP System tape gun: or roller to apply pressure to the tape
and smooth out any wrinkles.
Step 2. Wherever tape splices occur at a horizontal or vertical sear, create
an. overlapping splice of at least 3
At T-joints, the tape pieces should overlap by at least 1 ". Apply
moderate pressure onto the surface of the tape to ensure a secure
bond between the panel and the tape. .
Use the ZIP System tape gun or roller to apply pressure to the tape
and smooth out any wrinkles_
Take.special.care to remove any voids and/or trapped air at splice
areas and T joints.
Step 3. Tape inside and outside comer seams.
tarn
Note: Tape over any areas of the panel or tape that are damaged during constructlam
ZIP System* Roof & Wall Sheathing Installation. Manual
ZIP System -Window Installation OftlAIMERThefdbwingsteps represent ageneral overview for the proper installation ofwindowflasting.Plsasedefer tolconsuit
the installation instructions of your window manufacturer as well as code requirements In.yourlurWdidon for full installation de4vls.
Flanged Windows
1. Fasten the ZIP System sheathing
to the wood frame and install
ZIP System tape to all wall panel
seams, as detailed in sections
02 and 03. 3
}
2. ZIP System tape may be used as pan flashing if
installed in accordance with flanged window
installation details posted on zipsystem.com.
Other adhesive based flashing tapes (must meet
ICC-ES Acceptance Criteria for Flashing Materials
(AC148)) may be used as pan flashing if installed
per ASTM 2112-07. Apply the flashing to cover
the bottom of the opening, overhanging onto the
sheathing by at least 2" and extending a minimum
of 6" up each jamb.
3. Apply sealant around inside face of mounting
flange. Sealant must be gapped at the sill
to permit drainage. Install and level window per
manufacturer's installation instructions. Verify
sealant compatibility with window, manufacturer.
When using ZIP System tape as pan flashing,
butyl, 1000% silicone or polyurethane sealants
are acceptable. Do not use latex or other water -
based sealants.
4. Cut two pieces of ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-
ES Acceptance Criteria for. Flashing Materials
(AC148)) and apply to each of the window jamb
sill flashing.
Once the tape is In place, use the tape gun or roller .
to seal the flashing to the sheathing.
5. ,Cut a length of ZIP System tape or another
adhesive-backedflashing tape (must meet ICC-
ES Acceptance Criteria for Flashing Materials
(AC148)) and apply to the header, .ensuring that
the flashing overlaps the jamb flashings.•
Onoe the tape is in place, use the tape gun or roller
to seal the flashing to the sheathing.
TO NOT tape bottom flange.
6. From the interior, apply low-pressure polyurethane
foam (for windows) between the rough opening
and the window frame. (Caulk sealant compatible
with the sill,flashing may be used at the sill if the
opening between. the sill. flashing and window
is too narrow to allow the use of low-pressure
polyurethane foam.)
When using ZIP System tape, butyl, 100%
silicone or polyurethane sealants are. acceptable.
Do not use latex sealants with ZIP System tape. If
using another flashing tape, follow 'the flashing
manufacturer's recommendation in selecting a
sealant compatible with that flashing.
Bride Mould Windows
1. Fasten the.ZI P System sheathing.
to the wood frame and install
ZIP System tape to all wall panel
seams, as detailed in sections
02 and 03.
i
2. If recommended by the window
manufacturer, cut a strip of wood
to function as aback dam at the
sill. The wood strip should have
rough opening and a height and
width of at least 1/2". Position the
block at the Inside edge of the
window frame.
ZIP System - Window Installation 01SCLAIMERlbefdlowingstepsrepresent ageneral overulewforthepnaperinstallationofwindowflashing.Please defertoldwsult
the Installation instructions of your window manufacturer as wail as code requirements in yourjurisdction for full Installation details.
Brick Mould Windows (continued)
3. ZIP System tape may be used as pan flashing if
installed in accordance with brick mould window
installation details posted on apsystem.com.
Other adhesive -based flashing tapes (must meet
[CC' -ES Acceptance Criteria for Flashing Materials
(AC148)) maybe used as pan flashing if installed
per ASTM 2112-07. Apply the flashing to cover
the bottom of the opening, overhanging onto the
sheathing by at least 2" and extending•a minimum
of 6" up each jamb.
4. For vertical jambs, cut ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-
ES Acceptance Criteria for Flashing Materials
(AC148)) and apply to each of the window jambs.
Ensure that they cover lhe, entire inside of the rough
opening as well as overlap onto the sheathing by
at least 2". Flashing shall also extend above the
rough opening, such that It will project 1" beyond
the exterior trim of the window.
Once the tape is in place, use the tape gun or roller
to seal the. flashing to the sheathing.
S. Apply sealant to jambs and header allowing for
drainage at the sill in accordance with window
manufacturer's installation instructions. When
using ZIP System tape, use a butyl, polyurethane
or 100% silicone sealant. Do not use latex or
other water -based sealants with ZIP System
tape. When using another flashing tape, follow the
flashing manufao-ture.r's recommendations in
selecting a sealant compatible with that flashing.
6. Install and level window per manufacturer's
installation instructions.
7. Out a piece of rigid head flashing so that when
installed, it is flush with the edges of the exterior
moulding of the window. Apply a bead of sealant
to the back and bottom surface of the rigid
head flashing. Use sealant recommended by the
flashing manufacturer,
8. Secure the rigid head flashing to ZIP System
wall sheathing.
9. Cut a length of ZIP System tape or another
adhesive -backed flashing tape.(must meet ICC-ES
Acceptance Cdtddafor Flashing Materials (AC148))
and apply to the rigid head flashing, ensuring
that the adhesive -backed flashing overlaps the
jamb (lashings.
Once the tape is in place, use the tape gun or roller
to seal the flashing to the sheathing.
10.. From the interior, apply low-pressure polyurethane
foam (for windows) between the rough opening and
the window frame. (Caulk sealant compatible with
the sill flashing may be used at the sill it the opening
between the sip flashing and window is too narrow
to allow the use of low-pressure polyurethane foam.)
I
When using ZIP Systemtape, butyl,10096 silicone
or polyurethane sealants are acceptable. Do not .
use latex or other water -based sealants. %k ftt ZIP
System tape. If using another flashing tape, follow
the flashing manufacturer's recommendation in
selecting a sealant compatible with that flashing.
ZIP System? Roof & Wall Sheathing Installation Manual
............. _.-._ ... _ ..__._... .
ZIP System -Penetration Openings DECLAIMER: The folloMng steps represent a general overview br the proper installation of penetration flashing. Please defer tdconsutt
your code -requirements in yourjudsrricdan for full installation details.
A
WALL GSEAR0.y -�---'7�
WALL TEMS WALLSN-�11191fG
WOOOORLT.OA METALSTIID!
OVERIAPTAPE A LIMM OF
14RCHATALLT-W nS
1NSTALLLP SYSIEM9 TAPE ATALL
INIMORCORNERS
ORLOCJI.
WALL ASSEMBLY
ZJP SYSTEMS WALL SHEATHING
WOOD OR LT, GA.METAL STUDS
1184NCH GAP RECOMMENDED AT
PANEL EOGES UNLESS
OTHERWISE PROVIDEUBY
MACHINED PROFILED EDGES —
INSTALLZIP SYSTEM TAPE OR
AOHESIIIEBACKEO FLASHING (MM
MEET AC1481 IN SEOUFNCEMM
BOr70M, SLOES, THEN TOP TO
ENSURE SHINGLE LAP OF ADHESN
BACKED. FLASHING
ZIP SYSTEM&TAPE (INSTALLED
OVER ALLJOINTS'INZIP SYSTEMS
WALL SHEATHING}
OVERLAP TAPE A MWIMUM OF
1 INCH ATALL TJOniTS
USEFLANGED ELECTRrJ L '
BOXES OR MENIBRANEFLASHING
TOPRCVIOEFLANGESFOR ELECTRICAL BOXES
WALLAGSCNDLY
ZIP -SYSTEMS WALLSI¢ATNNG
WOODAR LT.GA METALSTUDS
TI&OCH GAP RECOMMENDED At
PANELEDGES WILESS
OTNERWM PPDvtOEOOY
MSCF'D W PROFIED EDGES —
OYEFMAP TAPEA VaLMMI OF
I• ATALLTJOMS—
FASTENZPST.SfBMWALL
SNEATHNGAS RC-0UtRED Dv
DESIGNeLOFRECORD OR LOCAL
BUMMOCOCE
WALL ASSEMBLY
ZIP SYSTEM& WALL SHEATHING
WOOD OR LT. GA..METAL STUDS
1I84NCH DAPRECOMMENDED AT
PANEL EDGES UNLESS
OTHERVASE.PROVOED BY
MACHINED PROFILED EDGES —
INSTALL ZIP SYSTEMOTAP£ OR
ADHESIVE BACKED FLASHING (MUST
MEET AC148) M SEQUENCE. FROM
BOTTOµ SIDES. THEN TOP TO
ENSURE SHINGLE LAP OF ADHESIVE
BACKED FLASHING
ZIP SYSTEMOTAPE (INSTALLED
OVER ALL JOINTS IN ZIP SYSTEMS
WALLSHEATHING).
OVERLAPTAPEA MININUMOF
1dNCH ATALL T•JOINTS
USE FLANGEOMENT MOODS - ...... .. .
ZIP System Sheathing Installation Details on Walls - visit zipsystem.com for more details.
WALL ASSEMRLV
VINYUWOODIFISERCFFMI"T SIDING
RNSTALIEGM%1CCORDANCI I.
CUDDINOMI W UFAOTDRER9
pNS7µlATION RECOMMMATIONS)
zlP sYsrEMS WALL SHEATHING
WOOD OR LT. GA METALS.TUDS
118 N GIREAT
PANEL EGGES UN1E39
GTHFRWISF PANNIER RV
MACHINEDPRORIID EDGES
ZIP SYSTFMW7APEtINSTALLED
OVER ALL JORAS IN ZIP SYSTEM
WALL SHEATHING).
OVERLAPTAPE A. MINIMUM OF
t. NCNATALLT4OW S
1/NNCHGAP RECOLI-ND® AT
PANEL EDGESULLLESS
OTNDNWM PROVIDED BY
MACHI SOPROALFD EDGES
FABTENZIPSYSTEM®WALL
SHEATHING AS REQUIRED BY
. J)F.SJGNFR-0FRECORO,OR LOCAL .. - .. -.
BURRING COTE
WALL ASSEMBLY
BRICK VENEER
AIR OPACE,(AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED
WITH ZIP.SYSTEM® TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AC148)
CODE APPROVED BASE
FLASHING --�
WEEP HOLES (AS PRESCRIBED
BY LOCAL BUILDING CODE) -
WALL ASSEMBLY
BRICKVENEER
AIRSPACE ,(AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYMMO WALLSHEATHNG
'WOODOR LT. GAMETAL STUDS
1/9INCHGAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDEDBY
MACHINED PROFILED EDGES
ZIP SYSTEM TAPE INSTALLED
OVER ALLJOINTS INZJP SYSTEH®
WALL SHEA7HWG). �\
OVERLAPTAPEA MNIMUMOF
14NCH ATlLLL 7JOINTS
1/&INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE.PROWOED BY
'MACHINED PROFILED EDGES
FASTEN ZIP SYSTEAM'JWALL ,
SHE0iING AS REOWRED BY
OESIDU�NER-CP4&CORDO,RtOCAL
INO CODE
Note: For optimal air leakage reduction; all untaped edges of the panels can be caulked, gasketed or sealed with a weather stripping material.
ZIP System? Roof & Wall Sheathing I nstallation .Manual
ZIP System Sheathing Installation Details on Walls (continued)
WALL ASSEMBLY
BRICK VENEER
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED
WITH ZIP SYSTEM® TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET.AC148)
CODE APPROVED FLASHING
WEEPS (AS PRESCRIBED. BY
LOCAL BUILDING CODE) —
STEEL LINTEL
INSTALL WINDOW IN
ACCORDANCE WITH DETAILS
24A-24D OR 25A-25D
WALL BEYOND
WALL.ASSEMBLY
CODE APPROVED CLADDING _
(INSTALLED IN ACCORDANCE WITH
CLADDING MANUFACTURER'S
INSTALLATION RECOMMENDATIONS)
EXTERIOR RIGID INSULATION
DRAINAGE PLANE:(MIN. Ya")
ZIP SYSTEM@ WALL SHEATHING
WOOD OR.LT..GA..METALSTUDS -
TOP EDGE OF FLASHING TAPED TO
WALL SHEATHING WITH ZIP SYSTEMS
TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEETAC148)
CODE APPROVED FLASHING
WALL BEYOND
BACKDAM PER WINDOW
MANUFACTURER'S INSTALLATION
RECOMMENDATIONS
INSTALL CODE -RECOGNIZED
SILLIPAN FLASHING IN ROUGH
OPENING PRIOR TO WINDOW
INSTALLATION.
TOP EDGE OF FLASHING TAPED
WITH ZIP SYSTEMS TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AC148)
WEEPS (AS PRESCRIBED BY
LOCAL BUILDING CODE) —
CODE APPROVED FLASHING
WALL ASSEMBLY
BRICK VENEER
AIR. SPACE (AS PRESCRIBED BY
LOCAL BUILDING CODE)
.ZIP SYSTEMO WALL -SHEATHING
'WOOD OR LT. GA. METALSTUDS
Note: For optimal air leakage reducdon,'all untaped edges of the panels can be caulked, gasketed or sealed with a weather stripping material.
IZIP SYSTEMS SHEATHING WITH HARD COAT STUCCO AT H-2
BLOCK FOUNDATION WALL- OPTION A
TRADITIONAL HARD -COAT STUCCO
INSTALLED IN ACCORDANCE WITH THE
LATH
MANUFACTURER'S OR THE PORTLAND
CEMENT ASSC. (PCA)
RECOMMENDATIONS WITH THE MOST
ONE LAYER OF WATER -RESISTIVE
RESTRICTIVE CONTROLLLING.
VAPOR -PERMEABLE. BARRIER
WITHPERFORMANCET LEAST
EQUIVALENT GRADE D
Yz
BUILDING PAPER.
ZIP SYSTEM® SHEATHING'
TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITH ZIP SYSTEM® TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AAMA 711 OR
AC148)
WOOD OR LT. GA.
METALSTUDS
100
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED
"
OVER TRANSITION JOINT (ZIP
SYSTEM TAPE, MAY BE USED AS
THE BRIDGE FLASHING)
CODE -APPROVED �Q
WEEP SCREED AT
BASE OF WALL
VERTICAL AND HORIZONTAL
CONTROL JOINTS AS NEEDED.
DESIGNER -OF -RECORD TO
SPECIFY TYPE AND LOCATION.
MASONRY BLOCK WALL
-ZIP SYSTEM@ SHEATHING IS APPROVED TO REPLACE ONLY THE
FIRST LAYER OF A TWO -LAYER UNDERLAYMENT SYSTEM.
DRAWING NOT TO SCALE
N TM Sales Office: David Taylor Drive ENGINEERED
o S SHEATHING
Suite.300 - Charlotte, NC 28262 aUB�R WOODS
o SHEATHING 8 TAPE Telephone: 800.933.9220 - www.zipsystem.com
These construction details are provided to assist in the installation of ZIP System® prouct(s) and may not apply to
every snuation. manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEMO SHEATHING WITH HARD COAT STUCCO AT H=2
BLOCK FOUNDATION WALL- OPTION A
WALL ASSEMBLY Y
TRADITIONAL HARD -COAT STUCCO
METAL LATH
ONE LAYER WATER-RES. BARRIER
ZIP SYSTEMS SHEATHING'
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITH ZIP SYSTEMO TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AAMA 711 OR
AC148)
CODE -APPROVED WEEP
SCREED AT BASE OF WALL -�
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT (ZIP SYSTEM
TAPE MAY BE USED AS THE BRIDGE 1
FLASHING) C
MASONRY BLOCK WALL
LATH
TOP EDGE OF WEEP SCREED TAPED
TO WALL SHEATHING WITH ZIP
SYSTEMS TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEET AAMA 711 OR
AC148)
TRADITIONAL HARD -COAT STUCCO
INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S OR THE. PORTLAND
CEMENT ASSC. (PCA)
RECOMMENDATIONS WITH THE MOST
RESTRICTIVE CONTROLLLING.
ONE LAYER. OF WATER -RESISTIVE
VAPOR -PERMEABLE BARRIER WITH A
PERFORMANCE AT LEAST EQUIVALENT
TO GRADE D BUILDING PAPER.
CODE -APPROVED WEEP
SCREED AT BASE OF WA
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT (ZIP SYSTEM
TAPE MAY BE USED AS THE BRIDGE
FLASHING)
MASONRY BLOCK WALL
*ZIP SYSTEMS SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO -LAYER UNDERLAYMEN7'1qSIENOT TO SCALE
+� . Sales Office:10925 David Taylor Drive
rpsysten7 NC --YV'� ENGINEERED
Suite 300 -Charlotte, Woods
SHEATHING & TAPE Telephone: 800.933.9220 - www.zipsystem.com
These construction details are provide to assist in the installation of ZWSystemducts an may not apply to
every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.