BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
Date: 1014 ( k Permit #: 1 � � y — O Y ZC zoo ='23
Contractor: k
Job Address: W 0 d S1,✓ ✓ terC
Construction: jq/) New Construction — Complete ( ) Existing — After Addition
House Infiltration est R ults SLC Climate Zone 2
CFM (50) _ _ 1 Test Date: kh
Volume = &lr%
ACH (50) = CFM (50) x 60 / Volume = ��� Mechanical Ventilation required less than 5 ACH
Passing results must be & ACH (50) or less ( Wass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7); Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and,
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential 3
Where the air infiltration rate of a dwelling unit is less tha it changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c.; (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: GFA International, Inc. Address: 607 NW Commodity Cove, Port 5t. Lucie, Florida
I hereby certify that the above Hous tion results demonstrate compliance with FBC Energy Conservation
requirements in a ordance with ctio,n R 02.4.1.2 Climate Zone 2.
Signature:
Printed Name: Michael Anderson
License/Certification #: BPI 5059963