FBC ENERGY CONSERVATION CODE R402.4.1.2
House Infiltration Test (Blower Door) Certification
Prescriptive and Performance Method
y Permit#:
�-..
'3 l
) New Construction
House Infiltration Test Results SLC Climate Zone 2
CFM (56) _ 1-L S"S- Test Date:
Volume = - j C 6 OLf . j
t / 6
ACH (50) = CFM (50) x 60 / Vol mu a =_ Passing results must be & ACH (50) or less Mechanical Ventilation required less than 3 ACH
(;Pass ( ) Fail
FBC, Energy
11402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to
penetrations of the
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. C. (50 Pa) in accordance with Section R402.4.1.2 of the
accordance with Section M1507.3
Testing Company r-'h
Company Name: SyG '' �� Address:
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: _ ��: � �,rk a walat
License/Certification #: �5�