HomeMy WebLinkAboutENERGY EFFICIENCY CODE 12-18-17/ FORM R405-2014
0"aa IS�bIXC L-44
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHEC
KC,I T
OLlal Cobblestone Drive lot
b r Sr 1. ` 10
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method cov
,Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (9 page) and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level (EPL) Display Card (one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1-
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
- R
File Copy
EnergyGaugeS - USRCZB v5.1
11/17/2016 i 1:33:23 AM Page 1 of 1
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
17 �• k4 �r1 W4
Project Name: Express 1828 Cali PSL Left NEW
Stree � CO j��%(�2 �l7eti r '
Builder Name:
Permit Ofce;5al w4 Lu ae- Cou✓1 l
City, State, Zip: S LUCIE , FL,
Permit Number.
Owner. Express Haines
Jurisdi etion�,•hF �duti COUN
2
Design Location: FL, ST_LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone )
1. New constriction or existing New (From Plans)
9. Wall Types (1751.2 sgft.)
a. Concrete Block - Int Insul, Exterior
Insulation Area
R=4.1 1 A 22.10 fit'
2. Single family or multiple family Single-family
b. Frame - Wood, Adjacent
R=13 0 329.12 K2
3. Number of units, if multiple family 1
c. NIA
R=fix
4
d. NIA
R= ft24.
Number of Bedrooms
10. Ceiling Types (1828.0 sgft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=38.0 1828.00 ft2
6. Conditioned floor area above grade (ft') 1828
b. NIA
R_ ft2
R= ft'
c. N/A
Conditioned floor area below grade (ft') 0
11. Ducts
R ft2
7. Windows(168.1 sgft.) Description Area
a. Sup: Attic, Ret: Attic. AH: whole house
6 150.3
a. U-Factor: Dbl, U=0.34 127.29 ft'
SHGC- SHGC=0.35
12. Cooling systems
kBtu/hr Efficiency
r 2
b. U-Factor: Dbl, U=0 63 40.8u ft
a Central Unit
35.0 SEER:15 50
SHGC SHGC=0.32
c. U-Factor NIA ft-
SHGC:
13. Heating systems
kStu/hr Efficiency
d. U-Factor: NIA ft2
a.. Electric Heat Pump
34 0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 2.758 ft.
14, Hot watersy stems
Area Weighted Average SHGC: 0.34e
a Electric
Cap: 50 gallons
8. Floo;Types (1828.0 sgft.) Insulation Area
EF:0.980
a. Slab -On -Grade Edge Insulation P.=0.0 1828.00 ft'
b. Conseriation features
b. N/A R= ft2
None
c. NIA, R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 56.76
PAS„
H
Glass/Float Area: 0.092 Total Baseline Loads: 59.99
I hereby certify that the plans and �spgcifications covered by
Review of the plans and
xs
oily sr.y
this calculation are in compliance wit 'the Florida Energy
specifications covered by this
`'
Code. is t 10'\
1ti.�`
calculation indicates compliance
with the Florida Energy Code.
rs'" f,, �,a� '•
�1 ;`
Before construction is completed*_
�.
PREPARED BY;
DATE: -^ �':`
this building will be inspected for
compliance with Section 553.908
�
*'
{
I hereby certify that thisp4il i as d ignpd, is in compliance
tisrith the Florida Energy Code, le ,
Florida Statutes.
y
�flD
OWNER/AGENT:_ _
BUILDING OFFICIAL:
DATE:
DATE:
-
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 On for whole house.
File COPY
1125i2017 3:23 PM EnergyGaugeO USA - FlaRes2014 Section R405,4.1 Compliant Software Page 1 of 4
FORM R405-2014.
•
PROJECT
Title:
Express 1828 Cali PSL Left N Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 1828
Lot #
Block/SubDivision:
Owner
Express Homes
Total Stories: 1
Yes
PlatBook:
# of Units:
1
Worst Case:
Rotate Angle: 135
Street:
Builder Name:
Cross Ventilation: No
County: St. Lucie
Permit -Office:
Whole House Fan: No
City, State, Zip: ST. LUCIE ,
Jurisdiction:
FL,
Family Type:
Single-family
New/E,xisting:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
Design
Location
TMY Site Zone 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL
FL VERO_BEACH_MUNI 2 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1828 16086.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
whole house
1828 16086.4 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio whole house 199 ft 0
1828 ftz ---- 0.5 0 0.5
ROOF
Roof Gable Roof
Solar SA Emitt Emitt Deck Pitch
#
Type
Materials Area Area Color
Absor. Tested Tested Insul. (deg)
1
Hip
Composition shingles 2044 ft2 0 ft2 Dark
0.9 No 0.9 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300
1828 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented) whole house 38 Blown 1828 ft2 0.11 Wood
1ill 7/2016 11:33 AM EnergyGauge® USA - FiaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Cavity Width Height
Sheathing
Framing Solar
Below
Adjacent Space
pR-Stallie
Et lo- Et
1 S=>NW Exterior Concrete Block - Int Insdhote house
4.1 18 0 8.8
0 158.4 ft2
0
0 0.8
0
2 W=>NE Exterior Concrete Block - Int InsaMole house
4.1 44 0 8.8
0 387.2 ft2
0
0 0.8
0
_!
3 N=>SE Exterior Concrete Block - Int Insdhole house
4.1 39.8 0 8.8
0 350.2 ft2
0
0 0.8
0
_
4 E=>SW Exterior Concrete Block - Int InsuVhole house
4.1 b9.8 0 8.8
0 526.2 ft2
0
0 0.8
0
5 S=>NW Garage Frame - Wood whole house
13 21.4 0 8.6
0 188.3 ft2
0
0.8
0
6 • W=>NE Garage Frame - Wood whole house
13 16 0 8.8
0 140.8 ft2
0
0.23 0.8
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Ft
Width
In
Height
Ft In
Area
1 S=>NW Insulated whole house
None
.4 3
6.8 20.4 ft2
2 S=>NW Insulated whole house
None
.4 2
8
16 ft2
WINDOWS
Orientation shown is the entered orientation =>) changed to Worst Case.
Wall
Overhang
/
V # Ornt ID Frame Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1 S=>NW 1 Vinyl Low-E Double Yes
0.34 0.35
2.5 ft2 5 ft 0 in
2 ft 0 in
None
None
2 S=>NW 1 Vinyl Low-E Double Yes
0.34 0.35
31.2 ft2 1 ft 0 in
4 ft 0 in
None
None
3 W=>NE 2 Vinyl Low-E Double Yes
0.34 0.35
15.6 ft2 1 ft0 in
2 ft 0 in
None
None
4 N=>SE 3 Vinyl Low-E Double Yes 1
0.34 0.35
62.4 ft2 1 ft 0 in
2 ft 0 in
None
None
5 E=>SW 4 Vinyl Low-E Double Yes
0.34 0.35
15.6 ft2 1 ft 0 in
2 ft 0 in
None
None
6 N=>SE 3 Vinyl Law-E Double Yes
0.63 0.32
40.8 ft2 8 It. 0 in
2 ft 0 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 607.76 fie 607.76 ft2
64 ft
8.8 ft
13
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .00028 1340.5 73.59 138.4 .2097
5
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:9
34 kBtulhr
1
sys#1
1 Ill7/2015 11:33 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
•
Subtype Efficiency Capacity
Air Flow
SHR Block Ducts
# System Type
Split SEER: 15.5 35 kBtu/hr
1077 drn
0.73 1 sys#1
1 Central Unit
HOT WATER SYSTEM
• # System Type SubType
Location EF Cap Use
SetPnt
Conservation
i Electric None
Garage 0.98 50 gal 70 gal
120 deg
None
•
SOLAR HOT WATER SYSTEM
Collector
Storage
FSEC
Cert # Company Name
System Model # Collector Model # Area
Volume FEF
ft,
None None
DUCTS
/ ---- Supply -- -
- Return --
Area
Leakage Type
Air
Handler
CFM 25
TOT
CFM25
OUT
ON
RLF
HVAC #
Heat Cool
V # Location
R-Value
Area
Location
1
Attic
6 150.3 ft
Attic
87.5 ft2
Prop. Leak Free
whole hous
--- cfm
54.8 cfm 0.03
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating Jan
Feb
Feb
Mar
Mar
ki
(]
[ ]Apr
Apr
] May
]May
Jun [X Jul
Jun [ Jul
riJul
[X] Aug
[ ] Aul
Aug
[[Xj Se
]Sep
[[ 1 Se
[ ]
[)Oct
[X]
Oct
Oct
[ ] Nov
(X]Nov
[X] Nov
[[ jDec
[X] Dec
[[ ]] Dec
Venting Jan
Feb
Mar
DC]
Apr
l May
Jun [
[ ))
Thermostat Schedule:
HERS 2006 Reference
Hours
8
9
10
11
12
Schedule Type
1
2
3
4
5 6
7
Cooling (WD)
PM
80
78
78
78 78
78
78
78
78
78
78
80
Cooling (WEH)
AM
78
78
78
78
78
78
78
78 78
78 78
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
Heating (WD)
AM
66
66
68
66
68
66
68
66 68
68 68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)
PM
PM
68
68
68
68
68
68 68
68
68
68
68
66
66
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 95
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.34
SHGC: SHGC=0.35
b. U-Factor. Dbl, U=0.63
SHGC: SHGC=0.32
c. U-Factor: N/A
SHGC:
d. U-Factor: NIA
SHGC:
Area weighted Average Overhang Depth:
Area Weighted Average SHGC:
,
ST. LUCIE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
1422.10 ft2
Single-family
b. Frame - Wood, Adjacent
R=13.0
329.12 ft2
1
c. NIA
R=
1`12
d. N/A
R=
ft2
4
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=38.0
1828.00 ft2
1828
b. NIA
R
ft2
ft2
c. NIA
R=
Area
11. Ducts
R ft2
127.29 ft2
a. Sup: Attic, Ret: Attic, AH: whole house
6 150.3
40.80 ft2
12. Gaoling systems
kBtu/hr
Efficient y
ft2
a. Central Unit
35.0
SEER:15.50
ft2
13. Heating systems
kBtulhr
Efficiency
a. Electric Heat Pump
34.0
HSPF:9.00
2.758 ft.
0.343
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1828.00 ft2
b. NIA R= ft2
c. N/A R= ft2
14. Hot water systems Cap: 50 gallons
a. Electric EF: 0.98
b. Conservation features
None
15. Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant f tures.
Builder Signature: //--��'� Date: 12/18/2017
Address of New Home:`�`L Cobblestone Drive City/FL Zip: Fort PierceYFl
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-14.92 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
t=lnrirla mmnnrtment of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number:
ST. LUCIE , FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
• ❑ 401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
[Section 553.9085, Florida Statues] requires the EPL display card to be in as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
Installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
Ad specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix C.
❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction.
Where required by the code official, an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building the envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not seated beyond intended
infiltration control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
O R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing (Mandatory)AII ducts, air handlers, and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction
or rough -in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99, Florida Statutes, or as authorized by Florida Statutes, to be "substantially leak free" by either of the following:
1. Post -construction test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All
register boots shall be taped or otherwise sealed during the test.
2. Rough -in test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g. (25Pa) across the system, including the manufacturer's air handier enclosure. All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm
(85 Umin) per 100 square feet (9.29 m2) of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 1 of 3
FORM R405-2014
I
L
MANDATORY REQUIREMENTS - (Continued)
R4.03.2.3 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.3 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or below 55°F (13`C) shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
R403.4.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
A
R403.4:4 Water heater efficiencies (Mandatory).
O R403.4.4.1 Storage water heater temperature controls
R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum
temperature setting range shall be from 100°F to 140°F (38•C to 60°C).
R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol, Collectors in installed solar water
heating systems should meet the following criteria:
rX
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.5 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
R403.6 Heating and cooling equipment (Mandatory). The following sections are mandatory for cooling and heating equipment.
0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors
which affect equipment sizing. System sizing calculations shalt not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 2 of 3
FORM R405-2014 Continued)
MANDATORY REQUIREMENTS - (
O R403.6.1.1 Cooling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and
shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling -only equipment. This
selection shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry bulb temperature for the
load calculation (or entering water temperature for water -source equipment), the blower drn provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multi -family. residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida -registered engineer, in attached single- and multi -family units, the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
• requirements calculated according to the procedure selected in Section R403.6.1.
11403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied through energy service to the building, shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F, and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSi/APSP-15. The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil -fired pool and spa heaters. All gas- and oil -fired pool and space heaters shall have a minimum
• thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
• with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment (Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low -voltage lighting shall not be required to utilize high -efficacy lamps.
O R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19. Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
11/17/2016 11:33 AM EnergyGauge(D USA - FlaRes2014 - Section R405.4.1 Cam Page 3 of 3
FORM R405-2014 TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Express 1828 Cali PSL Left NEW Builder Name:
Permit Office:
Street:
City, State, Zip: ST. LUCIE , FL, Permit Number.
Owner: Express Homes Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier,
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and seated to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
from the showers and tubs.
barrier installed separating them
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air seated boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
f 1
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 Section R405.4,1 Compliant Software Page 1 o
FLORIDA ENERGY: EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Express 1828 Cali PSL Left NEW Builder Name:
Street: Permit Office:
City, State, Zip: ST. LUCIE , FL, Permit Number.
Design Location: FL, ST_LUCIE CO_INTL Jurisdiction:
Cond. Floor Area:: 1828 sq.ft. Cond. Volume: 16086 cu ft.
Envelope Leakage Test Results
Regression Data:
C: n:
R:
Single or Multi Point Test Data
I I HOUSE PRESSURE FLOW: I
Leakage Characteristics
CFM(50):
ELA:
EgLA:
ACH:
ACH(50):
SLA:
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, Intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open:
Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open. _
I hereby certify that the above envelope leakage
performance results demonstrate compliance
with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
SIGNATURE:
PRINTED NAME:
DATE
Where required by the code official,
testing shall be conducted by an
approved third party. A written
report of the results of the test shall
be signed by the third party
conducting the test and provided to
the code official.
BUILDING OFFICIAL:
DATE:
1Ill 7/2016 11:33 AM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
• Form R405 Duct Leakage Test Report
PPrfnrmance Method
Project Name: Express 1828 Cali PSL Left NEW Builder Name:
Street: Permit Office:
City, State, Zip: ST. LUCIE , FL, Permit Number:
Design Location: FL, ST LUCIE_CO—INTL Jurisdiction:
Duct Test Time: Post Construction
n, ir-t I =akaae Test Results
CFM25 Duct Leakage Test Values
Line
System
Outside Duct Leakage
1
System 1
cfm25(Out)
2
System 2
cfm25(Out)
3
System 3
cfm25(Out)
4
System 4
cfm25(Out)
5
Total House
Duct System
Leakage
Sum lines 14
Divide by
(Total Conditioned Floor Area)
— (Qn,Out)
I certify the tested duct leakage to outside, Qn, is
not greater than the proposed duct leakage Qn
specified on Form R405-2014.
SIGNATURE:
PRINTED NAME:
DATE:
Duct tightness shall be verified by
testing to Section 803 of the RESNET
Standards by an energy rater certified in
accordance with Section 553.99,
Florida Statutes.
BUILDING OFFICIAL:
DATE:
11 /17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant S Page 1 of 1
Express 1 828 Cali Left Psl
HVAC Load Calculations
for
Express Homes
2),
.
wmkm IkVAC, RZsivSMnAj-
L oAas
Prepared By:
Kristin Kelly
Florida Breeze
6928 Vickie Circle Suite B
West Melbourne, FI 32904
3219518767
Thursday, November 17, 2016
File C.
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Elite
�Rhvae - Residential & Light Commercial HVAG Loads
'A/C,Service Masters, LLC r1
I , 1" B r] 32909 _
Pam a
!, Projed Report
,�,Gen,�e, r„al Project InfaP • m�atoi
Project Title:
Designed By:
1 Project Date:
Client Name:
i Company Name:
Company Representative:
Company Address:
Company City:
Company Phone:
j �peslgsa Data
i Reference City:
Building Orientation:
Daily Temperature Range:
Latitude:
Elevation:
Altitude Factor:
Express 1828 Cali Lett Hsi
Kristin Kelly
September 22, 2016
Express Homes
Florida Breeze
Kristin Kelly
6928 Vickie Circle Suite B
West Melbourne, FI 32904
3219518767
Fort Pierce, Florida
Front door faces South
Medium
27 Degrees
25 ft.
0.999
Outdoor Outdoor
Dry Bulb Wet Bulb
Winter: 42 39.4
Summer: 90 78
fleck Figur"es
Total Building Supply CFM:
Square ft. of Room Area:
Volume (ft3) of Cond. Space:
Outdoor
Indoor
Indoor
Grains
Rel.Hum
Rel.Hum
Dry Bulb
Difference
n/a
n/a
70
n/a
59%
50%
75
61
1,223 CFM Per Square ft.:
1,828 Square ft. Per Ton:
16,087
Total Heating Required Including Ventilation Air: 31,764 Btuh
Total Sensible Gain: 26,871 Btuh
Total Latent Gain: 6,875 Btuh
Total Cooling Required Including Ventilation Air: 33,746 Btuh
650
1.764 MBH
80 %
20 %
2.81 Tons (Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J Sth Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\...\EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
j Rhvac Residential & Light.GO
A/C Service Masters, LLC
Palm Bgy., FL 32909.
Miscellaneous Rex
j 'System 1
Summer:
i Calculate:
Use Schedule:
Roughness Factor:
Pressure Drop:
Minimum Velocity:
I Maximum Velocity:
Minimum Height
Maximum Height:
Guts Ze jQr ®ata
rcial ii:VAG.Loads
a
Yes
Yes
0.01000
0.1000
in.wg./100 ft.
550
ft./min
600
ft./min
0
in.
0
in.
59%
50%
Runouts
Yes
Yes
0.01000
0.1000
in.wg./100 ft.
450
ft./min
750
ft./min
0
in.
0
in.
Express i828 Caii Left Psi
Piae 3
n/a
61.09
Infiltration Specified: 0.380 AC/hr
0.200 AC/hr
{
1.02 CFM
54 CFM
I
Infiltration Actual: 0.380 AC/hr
0.200 AC/hr
Above Grade Volume: X 16.087 Cu.ft.
X 1,217 Cu.ft.
3 217 Cu.ft./hr
6,113 Cu.ft./hr
X OA167
X 0.0167
Total Building Infiltration: 102 CFM
54 CFM
Total Building Ventilation: 0 CFM
0 CFM
I
- —System 1—
Infiltration &Ventilation Sensible Gain Multiplier. 16.49
= (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 41.50
= (0.68 X 0.999 X 61.09 Grains Difference)
- Infiltration & Ventilation Sensible Loss Multiplier: 30.77
= (1.10 X 0.999 -X 28.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.380 AC/hr (102 CFM), Construction: Average
Summer Infiltration Specified: 0.200 AC/hr (54 CFM), Construction: Average
Duci Load Factor Scena 'os for S. stem 1
is
Duet Duct Surface
From
IVo. Tylpe I►3escription Location Feilin
Leakage Insulation eaNOWD
6 654
'
No
1 Supply Attic 16B
16B
0.12
0.12 6 474
No
1 Return Attic
I
i
C:\ ...\EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
Duct Size. -Preview
Room or Source
Duct'Name
System I
Supply Runouts
Zone 1
1 -Whole House Built -In
Other Ducts In System I
SuDoly Main Trunk Built-in
System 1
Heating Flow. 413
Cooling Flow 1223
_j
ium!
Maximum Rough. Deslgjnu SPI
] U100I Los s
1,—Duct
.41
lh
engthl
Htg
Flow
Ow
low
Flow
CIg
Ig
Flow
I �FCto'w
Actj Duct
Flow Size
Y
Velocity —Factor
460
750 0.01 0.1
518-9.
4113.M!
1,223 12-6
550
600 0.01 OA
560.4
413,Mj
11,223 20
Summary
C:\ ... \EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
. 1
window, vinyl frame, u-value 0.34, SHGG aa5
2A-v-d: Glazing -Double pane low-e (e = 0.60), sliding
glass door, vinyl frame, u-value 0.63, SHGC 0.32
11J:,Door-Metal - Fiberglass Core
13AB-Ofcs: Wall -Block, no blanket or board insulation,
filled core, siding finish
12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud
cavity, no board insulation, siding finish, wood studs
16B-38: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation
22A-pm: Floor -Slab on grade, No edge insulation, no
insulation below floor, any floor cover, passive, heavy
dry or light wet soil
Subtotals for structure:
People:
Equipment:
Lighting:
Ductwork:
Infiltration: Winter CFM: 102, Summer CFM: 54
Ventilation: Winter CFM: 0, Summer CFM: 0
System 1 Load Totals:
_ CfieekF° .tires
Supply CFM: 1,223
Square ft. of Room Area: 1,828
Volume (ft) of Cond. Space: 16,087
'S�siern�I_aads
Total Heating Required Including Ventilation Air:
Total Sensible Gain:
Total Latent Gain:
Total Cooling Required Including Ventilation Air:
40.8
720
0
660
660
1
36.4
612
0
568
568 `
1236.1
6,334
0
3,936
3,936
313.1
798
0
612
612
1828
1,331
0
2,376
2,376
199 6,575 0 0 0
17,562
0
10,532
10,532
5
1,000
1,150
2,150
1,020
3,563
4,583
0
0
0
11,067
2,629
10,742
13,371
3,135
2,226
884
3,110
0
0
0
0
31,764
6,875
26,871
33,74165
CFM Per Square ft.: 0.669
Square ft. Per Ton: 650
31;764 Btuh 31.764 MBH
26,871 Btuh 80 %
6,875 Btuh 20 %
33,746 Btuh 2.81 Tons (Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program. i
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions. {
C:\ ...\EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
Cooling
System Type:
Outdoor Model:
Indoor Model:
Tradename:
Outdoor Manufacturer:
Description:
AHRI Reference No.:
Capacity:
Efficiency:
Heating
System Type:
Model:
Tradename:
Manufacturer:
Description:
Capacity:
Efficient
Air Source Heat Pump
25HBC536A**30
FV4CNB006
BASE 15 PURON HP
CARRIER AIR CONDITIONING
Air Source Heat Pump
3645941
36375
15.5 SEER
Air Source Heat Pump
25HBC536A**30
BASE 15 PURON HP
CARRIER AIR CONDITIONING
Air Source Heat Pump
34000
y 9 HSPF
This system's equipment•was.selected in accordance with AC CA Manual S WIDl3: 70F Sen. gain:
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDS: 75F, SIRH: 50%,
26,871 Btuh, Lat. gain: 6,875 Btuh, Sen. loss: 31,764 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F,
Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req, clg. airflow: 1223 CFM, Req. htg. airflow: 413 CFM
i
C:\ ...\EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
! e
SF
Stott
CFM
Size el Bt h
B
-
C •
I —Zone 1-
1 Whole House
1,828
31,764
413
12-6 519 26,871
4,246
1,223 1,223
Duct Latent
2,629
I System 1 total
1,828
31,764
413
26,871
6,875
1,223 1,223
System 1 Main Trunk Size:
20
in.
Velocity:
560
ft./min
Loss per 100 ft.:
0.040
in.wg
doling S: stem Silrrrmaty
.
Ccsolirtg
Sensib e/L ent
Sansib
latent
1-otal
Tans
5 lit
Btu
Btu
Btuh ,
Net Required:
2.81
80% / 20%
26,871
61875
41443
33,746
:b 36,375
I Actual:
3.03
88% / 12%
31,932
Type: Air Source Heat Pump Air Source Heat Pump
Model: 25HBC536A**30 25HBC536A**30
Indoor Model: FV4CNB006
Brand: BASE 15 PURON HP BASE 15 PURON HP
Description: Air Source Heat Pump Air Source Heat Pump
15.5 SEER
9 HSPF
Efficiency. 0
Sound: 0
Capacity: 34,000 Btuh 36,375 Btuh
Sensible Capacity: n/a 31,932 Btuh
Latent Capacity: n/a 4,443 Btuh
AHRI Reference No.: n/a 3645941
t This systems equipment was selected in accordance with ACCA'Manual
Manual-8 equipment sizing data: SODS: 90F, SOWB: 78F, WODS: 42F, S B: 75F, SIRH: 50%, WIDB: 70F, Sen. gain:
26,871 Btuh, Let. gain: 6,875 Btuh, Sen. loss: 31,764 Btuh, Entering clg. coil DB: 75F, Entering cig. coil WB: 62.5F,
Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1223 CFM, Req. htg. airflow: 413 CFM
C:\ ...\EXPRESS 1828 CALI LEFT PSL.rh9
's
i
i
Thursday, November 17, 2016, 11:37 AM
;/`R.1'1
County, Town, Municipality, Jurisdiction
Header Information
Contractbr Florida Breeze
Mechanical License # CAC1814113
Building Plan #
Home Address (Street or Lot#, Block, Subdivision)
Form
RIPER 1.01
8 Mar 10
REQUIRED ATTACHMENTS'
ATTACHED
Manual A Form (and supporting worksheets):
Yes ❑X
No ❑
or MJ1AE Form' (and supporting worksheets):
Yes ❑
No X❑
OEM performance data (heating, cooling. blower):
Yes ❑X
No ❑
Manual D Friction Rate Worksheet:
Yes ❑
No ❑X
Duct distribution system sketch:
Yes ❑
No ❑X
Winter Design Conditions
Building
OF Orientation door faces)
South
Outdoor temperature
42
(Front
70
of North, East, West, South, Northeast,
Northwest, Southeast, Southwest
Indoor temperature
Number of bedrooms
�1
4
Total heat loss
31764
Btu/h
1 828 Sq Ft
Conditioned floor area
Summer Design Conditions
Outdoor temperature
90
OF Number of occupants
5
Indoor temperature
75
of Windows
Roof
Grains difference 61
0 Gr @ 50 % Rh Eave overhang depth
2 7 Ft
Sensible heat gain
26871
Btu/h Internal shade
Eave
Latent heat gain
6875
Btu/h Blinds, drapes, etc
Depth
Window
' Total heat gain
33746
Btu/h Number of skylights
0
4!
Heating Equipment Data
Cooling Equipment Data
Blower- Data
Equipment type
Heat pump
Equipment type Heat pump
Heating CFM CFM
Furnace, Heat pump, Boiler, etc.
Air Conditioner, Heat pump, etc
.1285
Model
25HBC536A**30
Model 25HBC536A**30
Cooling CFM 1285 CFM
Heating output capacity
34000 Btu/h Sensible cooling capacity 31932 Btulh
Heat pumps - capacity at winter design outdoor conditions
Latent cooling capacity Btu/h
444
Auxiliary heat output capacity
Btu/h Total cooling capacity 36375 Btu/h
DUCT DISTRIBUTION
Y •
,HVAC
Design airflow
CFM
Longest supply duct: Ft Duct Materials Used (circle)
Trunk Duct: Duct board, Flex, Sheet metal,
External Static Pressure (ESP)
IWC
Longest return duct: Ft
Lined sheet metal, Other (specify)
Component Pressure Losses (CPL) IWC Total Effective Length (TEL)
Available Static Pressure (ASP)
ASP = ESP - CPL
Contractor's Printed Name Kristin
Contractor's Signature
IWC Friction Rate:
Friction Rate = (ASP -100) - TEL
— Ft Branch Duct: Duct board, Flex, Sheet metal,
IWC Lined sheet metal, Other (specify)
Date 7/1012015
' The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of Instructions.
' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions.
Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.
Air Conditioning Contractors of America
Manual S (Residential Equipment Selection)
Project Information Cooling Design Information
Name: Outdoor Design Temp: 91 °F db Summer
City: Outdoor Design Temp: 43' °F db IWinter
Stater Altitude: �� Altitude Adjustment: 1.00 Indoor Design Temp: 75 °F db 50 %RH 63 °F wb
Manual J Load Calculations
Total Load
Sensible
Latent
SHR Heat Loss
33746
26871
6875
0.796
Airflow Calculations
Design TD for Airflow
19
Design Sensible CFM
1286
OEM Information
Manufacturer: lCarrier Furnace Model #:1— AFUE:�
Coil or Fan -Coil Model #: I FV4CNB006 Condenser Model #: 25HBC536A SEER 15.5 HSPF: 9.00
(A) Manufacturer's Cooling Performance Data
Lower Return Air
Outdoor Temperature =
F 95 (F db)
Entering Coil Temperature = 75 (F db) CFM (F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rated CFM @ Rated RA Temperature 67
37,900
27,120
10.780
0.7156
Rated CFM @ Design RA Temperature 1050 63
F 35,204
31,056
4,148
0.8822
Rated CFM @ Rated RA Temperature 62
34,530
32,040
2,490
0.9279
(B) Manufacturer's Cooling Performance Data
Higher Return Air
Outdoor
Temperature
r 95 (F db)
Entering Coil Temperature = 75 (F db)
CFM (F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rated CFM @ Rated RA Temperature
67
39,270
F 87700
0.7785
Rated CFM @ Design RA Temperature
1350 63
36, 994
35,266
1,428
0.9611
Rated CFM @ Rated RA Temperature
62
36.050
36,440
-390
1.0108
Manufacturer's Cooling Performance Data (Interpolated)
Design Return Air Outdoor Temperature = 95 (F db)
CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR
34.364 F 27011 0.9447
Excess Latent Capacity Calculation +F 2.432 -F -2,432
Capacity @ Design CFM / RA (F wb) 1285.7 63 36,375 3i,932 4.443 0.878
Equipment Capacity as a % of Design 107.79% 1 118.83% J F&.63%
Manufacturer's Heat Pump Data
Capacity
Capacity
Balance Supplemental
@ 47 °F db
@ 17 °F db
Point Heat Required
34,800
18,820
-18.3 -15.87
Manufacturer's Furnace Data -
Input Output Desired Calculated
FEATURES
Environmentally Sound Refrigerant Technology
• Puront chlorine4ree non -ozone depleting refrigerant
• Thermostatic Expansion Valve (rXV) designed to maximize performance with Puron® refrigerant
Energy Efficient Operation
• Electronically Commutating Motor (ECM) operates efficiently at all speeds
• Maximizes efficiency of heating and cooling systems
• Ultra low power consumption during fan only operation
Indoor Weather Control
• Warm, comfortable heating air temperatures
• Unmatched humidity control, especially with Carrier's Thermidistat' Control
Airflow and Sound Technology
• Diffuser air discharge section for high airflow efficiency and quiet, smooth operation
• High duct static capability
tr8 M _; R _
Condensate Control and Disposal Technology
• Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage
• Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance
• Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary
line conditions
• Tested for condensate disposal at conditions much more severe than those required by AHRI
• Primary and secondary drain connections to comply with HUD
• All pans constructed of an injection molded glass -filled polycarbonate engineered resin material, with brass drain connections.
• High density, super thick cabinetry insulation with vapor barrier
• Pre -painted galvanized sheet metal cabinet
Heat Transfer Technology
• Grooved copper tubing
• Lanced sine wave aluminum fins
• Discreet refined counter -flow refrigerant circuitry
• Bi-flow hard shut-off TXV metering device
• ArmorCoat- coil protection available
Quality Assisting, Ease of Installation and Service Features
• All units multipoise
• Provision made for suspending from roof or ceiling joints
• Modular cabinet on 003 thru 006 units
• Sweat connections for leak free service
• Multiple electrical entry for application flexibility (high and low voltage)
• Low voltage terminal strip, to safely hold connections within the cabinet
• Inspection plate on A -coil models for quick coil cleanliness inspection
• Cabinet construction features innovations designed to prevent cabinet sweating
Controls and Electrical Features
• Easy Select'" Board to maximize comfort, efficiency, and safe heater airflow operation
• Easy plug connection provided for quick installation of accessory heater packages
• 40VA 20$0-30v transformer
• Replaceable 5-amp blade -type auto fuse protects against transformer secondary short
Filter Features
• Factory supplied filter
• Cleanable polyester filter media
• Filter "springs" out for easy access - no tools required
• Newly improved filter rack area - filter door insulation added for an unproved air seat