HomeMy WebLinkAboutFBC ENERGY CONSERVATION CODE 8-2-18Date: S>1211g
Contractor:
Job Address:
Planning & Development Services; Building & Code Regulation Division
2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982
772-462-2165 Fax 772-462-6443
FBC ENERGY CONSERVATION CODE R402.4.1.2 RECEIVED
House Infiltration Test (Blower Door) Certification
Prescriptive and Performance Method
4UG-0 7 �R,A
Pgit�t1v
Permit #:
Construction: ('X) New Construction — Complete ( ) Existing —After Addition
House Infiltration Test Results
CFM (50) _ - 05
Volume = C �� �?
ACH (50) = CFM (50) x 60 / Volume =
Passing results must be & ACH (50) or less
SLC Climate Zone 2 8
Test Date: //0V2
Mechanical Ventilation required less than 3 ACH
m Pass ( ) Fail
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in
accordance with Section M1507.3.
Testing Company
Company Name:
I hereby certify t�he a
requirements accordar
Signature:
G
C 57o C tgan cy sosy,,4r e b)-� roe u 1w
Address: JGc%ovi�P _ 3.�Z22_5,
House Infiltration results demonstrate compliance with FBC Energy Conservation
with Section R402.4.1.2 Climate Zone 2.
Printed Name: v:I'' P'
License/Certification #: X(V W "