FBC ENERGY CONSERVATION CODE':R402.4.1.2
House Infiltration Test (Blower Door) Certification
Prescriptive and Performance Method
Date: /"� Permit #:
Contractor: D I,orkoN
Job Address:
r�
Construction: New Construction — Complete ( ) Existing — After Addition
House Infiltration Test Results
CFM (50) = 1 9'qg
Volume = -2-19 /
ACH (50) = CFM (50) x 60 / Volume =
Passing results must be & ACH (50) or less
SLC Climate Zone 2
Test Date: j !//2 !g
Mechanical Ventilation required less than 3 ACH
(")'4 Pass' ( ) Fail
i
FBC, Energy
R402.4.1.2 Testing. The building or dwelling - unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting'wf test and provided to the code official. Testing shall be performed at any time after.creation (of all
penetrations of the building thermal envelope.
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air, changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section 11402.4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in
accordance with Section M1507.3.
Testing Company q5?z je9e,,ir �y �IV st Li IfD
Company Na S L Address: —Sctcicsnnvi 1 I� (= I 3�2�S
I hereb ertify that th above House Infiltration results demonstrate compliance with FBC Energy Conservation
requir ments in acc dance with Section R402.4.1.2 Climate Zone 2.
Signature: _
Printed Nam : �G M1* CC-,O ECEIVED
License/Certification #: r N� s w Nov 13 2018
Permitting .pepartment
St. Lucie County, FL