RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
O Vl3 Cobblestone Drive lot /-S—
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (1 page) and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level (EPL) Display Card (one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
EnergyGauge®- USRCZB v5.1
File Copy
Page 1 of 1
11/17/2016 11:33:23 AM
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Builder Name: 1� /�• �lbn uc,
1828 Cali PSL Left NEW
Stree ��%j��ry pe. r17� �w
Project Name: Cool
Permit Office•,Jz, w�- 1-d ae- CouA�
State, Zip: S LUCIE FL,
Permit Number:
City, ,
Owner: Express Homes
Jurisdiction:,�a,•N(- I_JL41t 6mjA4y
Design Location: FL, ST_LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1751.2 sgit.)
a. Concrete Block - Int insul, Exterior
Insulation Area
R=4.1 1422.10 W
2 Single family or multiple family Single-family
b. Frame - Wood, Adjacent
R=13.0 329.12 ft'
3. Number of units, if multiple family I
c, N/A
P.= ft=
4
d. N/A
R= ft'
4. Number of Bedrooms
10. Ceiling Types (1828.0 sgft.)
insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=38.0 1828.00 ft2
6 Conditioned floor area above grade (ft) 1
A
b. NIA
R= ft2
R= tiL
c. NIA
Conditioned floor area below grade (ft') 0
11. Ducts
R ft2
7 Windows(168.1 sqft.) Description Area
a. Sup: Attic, Ret: Attic. AH: whole house
6 150.3
a. U-Factor: Dbl, U=0.34 127.29 ft2
SHGC- SHGC=0.35
12. Cocling systems
kBtulhr Efficiency
b. U-Factor' Dbl, U=0 63 40.80 ft'
a. Central Unit
35.0 SEER:15.50
SHGC. SHGC=0.32
c. U-Factor N/A ft2
SHGC:
13. Heating systems
k8tu/hr Efficiency
d. U-Factor. N/A ft2
a Electric Heat Pump
34 0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Death: 2.758 ft-
14. Hot water systems
Area Weighted Average SHGC: 0.343
a. Electric
Cap: 50 gallons
8. Floor Types (1828.0 sgft.) Insulation Area
EF: 0.980
a. Slab -Or, -Grade Edge Insulation P.=0.0 1828.00 ft'
b Conservation features
b N/A R= ft2
None
c. NIA R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 56.76
PASS
Glass/Floor Area. 0.092 Total Baseline Loads: 59.99
I hereby certify that the ,plans and specifications covered by
this are in compliance witkthe Florida Energy
Review of the plans and
specifications covered by this
�a S7.4 Q�
''
calculation
Code.
calculation indicates compliance
c,,"" r,, F s�;�41
BY: v
with the Florida Energy Code.
Before construction is completed
�
PREPARED
t11�10 i
this building will be inspected for
DATE: I_-
compliance with Section 553.908
* r
I hereby that thisq ilQ1 as desigped, is in compliance
Florida Statutes,
�
'�+QD
certify
with the Florida Energy Cod,
�
OWNER/AGENT: _ __
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualities as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4,1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house.
t/2512017 3:23 PM EnergyGaugeO USA - FiaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM 'R405-2014
PROJECT
Title:
Express 1828 Cali PSL Left N Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 1828
Lot #
Block/SubDivision:
Owner.
Express Homes
Total Stories: , 1
Yes
PlatBook:
# of Units:
1
Worst Case:
Rotate Angle: 135
Street:
Builder Name:
Cross Ventilation: No
County: St. Lucie
Permit Office:
Whole House Fan: No
City, State, Zip: ST. LUCIE ,
Jurisdiction:
FL,
Family Type:
Single-family
New/Existing:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
Design
Location
TMY Site Zone 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL
FL_VERO_BEACH_MUNI 2 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1828 16086.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
whole house
1828 16086.4 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio whole house 199 ft 0
1828 ft2 ---- 0.5 0 0.5
ROOF
Roof Gable Roof
Solar SA Emitt Emitt Deck Pitch
#
Type
Materials Area Area Color
Absor. Tested Tested Insul. (deg)
1
Hip
Composition shingles 2044 ft2 0 ft2 Dark
0.9 No 0.9 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300
1828 ft' N N
CEILING
#
Ceiling Type
Space R-Value ins Type Area Framing Frac Truss Type
1
Under Attic (Vented) whole house 38 Blown 1828 ft' 0.11 Wood
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM "R405-2014
WALLS
Cavity Width Height
Sheathing
Framing Solar
Below
Adjacent S ace
PArpi
1
S=>NW Exterior Concrete Block - Int Insdhole house
4.1 18 0 8.8
0
158.4 ft2
0
0 0.8
0
2
W=>NE Exterior Concrete Block - Int Insal+hole house
4.1 44 0 8.8
0
387.2 ft2
0
0 0.8
0
3
N=>SE Exterior Concrete Block - Int Insulthote house
4.1 39.8 0 8.8
0
350.2 ft2
0
0 0.8
0
_
4
E=>SW Exterior Concrete Block - Int Insuftle house
4.1 59.8 0 8.8
0
526.2 ft2
0
0 0.8
0
_
5
S=>NW Garage Frame - Wood whole house
13 21.4 0 8.8
0
188.3 ft2
0
0.8
0
_
6
W=>NE Garage Frame - Wood whole house
13 16 0 8.8
0
140.8 ft2
0
0.23 0.8
0
DOORS
# Omt Door Type Space
Storms
U-Value
Ft
Width
In
Height
Ft In
Area
1 S=>NW Insulated whole house
None
.4
3
6.8 20.4 ft2
2 S=>NW Insulated whole house
None
.4
2
8
16 ft2
WINDOWS
Orientation shown is the entered orientation (=>) changed to Worst Case.
Overhang
Wall
# Ornt ID Frame Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1 S=>NW 1 Vinyl Low-E Double Yes
0.34 0.35
2.5 ft2
5 ft 0 in
2 ft 0 in
None
None
2 S=>NW 1 Vinyl Low-E Double Yes
0.34 0.35
31.2 ft2
1 ft 0 in
4 ft 0 in
None
None
3 W=>NE 2 Vinyl Low-E Double Yes
0.34 0.35
15.6 ft2
1 ft 0 in
2 ft 0 in
None
None
4 N=>SE 3 Vinyl Low-E Double Yes
0.34 0.35
62.4 ft2
1 ft 0 in
2 ft 0 in
None
None
5 E=>SW 4 Vinyl Low-E Double Yes
0.34 0.35
15.6 ft2
1 ft0 in
2 ft 0 in
None
None
6 N=>SE 3 Vinyl Low-E Double Yes
0.63 0.32
40.8 ft2
8 ft 0 in
2 ft 0 in
None
None
GARAGE
# Floor Area. Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 607.76 ft2 607.76 ft2
64 ft
8.8 ft
13
INFILTRATION
#
Scope Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .00028 1340.5 73.59 138.4
.2097
5
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:9
34 kBtu/hr
1
=YS#,
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
F# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
Split
SEER: 15.5 35 kBtu/hr
1077 cfm
0.73
1
sys#1
1 Central Unit
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 50 gal
70 gal
120 deg
None
SOLAR HOT WATER SYSTEM
Collector
Storage
FSEC
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
f2
None None
DUCTS
—Supply --
-- Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 150.3 ft
Attic
87.5 W Prop. Leak Free
whole hous
— cfm
54.8 cfm 0.03
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan [[ ]]Feb
Heating Jan [X] Feb
[( ]jMar
[X] Mar
[
[
j Apr
]Apr
]May rl Jun ri Jul
]May Jun Jul
Jul
Aug
ri Aug
Au
Sep
Sep
ri$ep
`
L.1
lxl
j Oct
Oct
Nov
}� Nov
Dec
DecVenting
Jan [[ l] Feb
([X]jl Mar
[Xl
Apr
) May Jun
Thermostat Schedule: HERS 2006 Reference
Hours
8
9
10
11
12
Schedule Type
1
2
3
4 5 6
7
Cooling (WD) AM
78
78
80
78
78
78 78 78
78 78 78
78
78
78
78
80
78
80
78
80
78
80
78
PM
80
Cooling (WEH) PM
78
78
78 78 78
78
78
78
78
78
78
78
Heating (WD) PM
68
66
68
68
68 68 68
66 8
68
8
68
68
68
68
66
66
68
Heating (WEH) PM
68
68
68
68
68 68 68
68
68
68
8
68
68
68
66
68
66
11/17/2016 11:33 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 95
The lower the EnergyPerformance Index, the more efficient the home.
, ST. LUCIE, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
a. Concrete Block - Int Insul, Exterior
Insulation
R=4.1
Area
1422.10 ft2
2. Single family or multiple family
Single-family
b. Frame - Wood, Adjacent
R=13.0
329.12 ftz
3. Number of units, if multiple family
1
c. NIA
R_
ft2
ft2
d. NIA
R=
4. Number of Bedrooms
4
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=38.0
1828.00 ftz
6. Conditioned floor area (ftz)
1828
b. WA
a NIA
R=
R=
ft2
ft2
7. Windows" Description
Area
11. Ducts
R ft2
a. U-Factor: Dbl, U=0.34
127.29 ft2
a. Sup: Attic, Ret: Attic, AH: whole house
6 150.3
SHGC: SHGC=0.35
b. U-Factor: Dbl, U=0.63
40.80 ft2
12. Cooling systems
kBtulhr
Efficiency
SHGC: SHGC=0.32
ft2
a. Central Unit
35.0
SEER:15.50
c. U-Factor: NIA
SHGC:
d. U-Factor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
34.0
HSPF:9.00
Area Weighted Average Overhang Depth:
2.758 ft.
Area Weighted Average SHGC:
0.343
8. Floor Types
Insulation
Area
14. Hot water systems
Cap:
50 gallons
a. Slab -On -Grade Edge Insulation
R=0.0
1828.00 ft2
a. Electric
EF: 0.98
b. N/A
R=
ft
b. Conservation features
c. NIA
R=
ft2None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant fe tures.
Builder Signature: Date: 12/18/2017
Address of New Home:gy/3 Cobblestone Drive City/FL Zip: Fort Pi m _, FI
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/17/2016 11:33 AM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
FInrir]a nomnartment of Business and Professional Regulations
-
MANDATORY REQUIREMENTS See individual code sections for full cietalls.
❑ 401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statues] requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix C.
❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction.
Where required by the code official, an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
O R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403A.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing (Mandatory)AII ducts, air handlers, and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction
or rough -in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99, Florida Statutes, or as authorized by Florida Statutes, to be "substantially leak free" by either of the following:
1. Post -construction test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturers air handler enclosure. All
register boots shall be taped or otherwise sealed during the test.
2. Rough -in test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g. (25Pa) across the system, including the manufacturees air handler enclosure. All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm
(85 Umin) per 100 square feet (9.29 m2) of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Dud testing is not mandatory for buildings complying by Section R405 of this code.
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/z inches (89 mm) in the hot water distribution line and cold water line )ocated as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies (Mandatory).
R403.4.4.1 Storage water heater temperature controls
G
L
R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum
temperature setting range shall be from 100°F to 140°F (38°C to 60°C).
R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
• to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol, Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment (Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors
which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and
shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling -only equipment. This
selection shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry bulb temperature for the
load calculation (or entering water temperature for water -source equipment), the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multi -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida -registered engineer, in attached single- and multi -family units, the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system Is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied through energy service to the building, shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F, and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40•F.
❑ R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSi/APSP-15. The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil -fired pool and spa heaters. All gas- and oil -fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment (Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low -voltage lighting shall not be required to utilize high -efficacy lamps.
O R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19. Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 3 of 3
FORM R405-2014 TABLE 402.4.1.
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Express 1828 Cali PSL Left NEW Builder Name:
Permit Office:
Street:
City, State, Zip: ST. LUCIE , FL, Permit Number.
Owner: Express Homes Jurisdiction:
Design Location: FL, ST_LUCIE_CO INTL
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be seated.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Barrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
A -CA
11/17/2016 11:33 AM EnergyGauge® USA - FlaRes2014 Section R4Ub.4.1 uompuani ounware aye
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Express 1828 Cali PSL Left NEW Builder Name:
Street: Permit Office:
City, State, Zip: ST. LUCIE , FL, Permit Number.
Design Location: FL, ST_LUCIE_CO_INTL Jurisdiction:
Cond. Floor Area:: 1828 sq_ft. Cond. Volume: 16086 cu ft.
Envelope Leakage Test Results
Regression Data:
C:
n:
Leakage Characteristics
R: CFM(50):
Single or Multi Point Test Data
I HOUSE PRESSURE I FLOW:
ELA:
EgLA:
ACH:
ACH(50):
SLA:
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
I hereby certify that the above envelope leakage
performance results demonstrate compliance
with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
SIGNATURE:
PRINTED NAME:
DATE:
Where required by the code official,
testing shall be conducted by an
approved third party. A written
report of the results of the test shall
be signed by the third party
conducting the test and provided to
the code official.
BUILDING OFFICIAL:
DATE:
1ill 7/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Express 1828 Cali PSL Left NEW Builder Name:
Street: Permit Office:
City, State, Zip: ST. LUCIE , FL, Permit Number.
Design Location: FL, ST_LUCIE_CO INTL Jurisdiction:
Duct Test Time: Post Construction
nr in I aakanP Test Results
CFM25 Duct Leakage Test Values
Line
System
Outside Duct Leakage
1
System 1
cfm25(Out)
2
System 2
cfm25(Out)
3
System 3
cfm25(Out)
4
System 4
cfm25(Out)
5
Total House
Duct System
Leakage
Sum lines 14
Divide by
(Total Conditioned Floor Area)
_ (Qn,Out)
I certify the tested duct leakage to outside, Qn, is
not greater than the proposed duct leakage Qn
specified on Form R405-2014.
SIGNATURE:
PRINTED NAME:
DATE:
Duct tightness shall be verified by
testing to Section 803 of the RESNET
Standards by an energy rater certified in
accordance with Section 553.99,
Florida Statutes.
BUILDING OFFICIAL:
DATE:
11M 7/2016 11:33 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant S Page 1 of 1
Express 1828 Cali Left PS/
HVAC Load Calculations
for
Express Homes
w ttnVAC, RVsmaunAL
VAC 40AD S
Prepared By:
Kristin Kelly
Florida Breeze
6928 Vickie Circle Suite B
West Melbourne, FI 32904
3219518767
Thursday, November 17, 2016
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
thvac -Residential & Light Comrinercial HVA Loads ~` Eliie Software Development, Inc
UC Service Maskers, LLC Express 1828"Cah Left P:
PaY e
palm Bay FL 32909
9'
Designed By:
Project Date:
Client Name:
i Company Name:
Company Representative:
Company Address:
Company City:
Company Phone:
i
i mDesign Data - Fort Pierce, Florida
Building Orientation: Front door faces South
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
i Outdoor Outdoor Outdoor Indoor
Dry Bulb Wet Bulb Rel.Hum Rei.Hum
Winter: 42 39.4 n/a n/a
i Summer: 90 78 59% 50%
Express 1828 Cali Left Psi
Kristin Kelly
September 22, 2016
Express Homes
Florida Breeze
Kristin Kelly
6928 Vickie Circle Suite B
West Melbourne, FI 32904
3219518767
`Check Figures
j Total Building Supply CFM: 1,223
Square ft. of Room Area: 1,828
Volume (ft3) of Cond. Space: 16,087
Indoor
Grains
Dry Bulb
Difference
70
n/a
75
61
Square ft. Per Ton:
Total Heating Kequirea inciuumg vwim-lult 26,871 Btuh
j Total Sensible Gain:
Total Latent Gain: 6,875 Btuh
Total Cooling Required Including Ventilation Air: 33,746 Btuh
0.669
650
31.764
MBH
80
%
20
%
2.81
Tons (Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
I
i
C:1... \EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
_- --- --
f Rhvac - Residential & Light Commercial HVAC Loadsent,;, nc
Elitee 5aftware Deve oprn
i r A/C Service Masters, LLC Express 1628`'Ca i Left PSI
Pane 3
Palmer. FL.32909
;,•Miscellaneous Report
winter:
Summer:
j Calculate:
Use Schedule:
Roughness Factor:
Pressure Drop:
Minimum Velocity:
Maximum Velocity:
Minimum Height:
Maximum Height:
OuEsiL57F it Data
i
Infiltration Specified:
Infiltration Actual:
Above Grade Volume:
i
Total Building Infiltration:
Total Building Ventilation:
42 39.4
90 78
Yes
Yes
0.01000
0.1000
in.wg./l00 ft.
550
ft./min
600
ft./min
0
in.
0
in.
Winter
0.380
AC/hr
102
CFM
0.380
AC/hr
X 16,087
Cu.ft.
6,113
Cu.ft./hr
X 0.0167
102
CFM
0
CFM
80% - n/a 70 nla
59% 50% 75 61.09
Runouts
Yes
Yes
0.01000
0.1000
in.wg./l00 ft.
450
ft./min
750
ft./min
0
in.
0
in.
0.200
AC/hr
54
CFM
0.200
AC/hr
X 16,087
Cu.ft.
3,217
Cu.ft./hr
X 0.0167
54
CFM
0
CFM
j --System 1---
Infiltration & Ventilation Sensible Gain Multiplier. 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference)
j Infiltration & Ventilation Sensible Loss Multiplier. 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.380 AC/hr (102 CFM), Construction: Average
Summer Infiltration Specified: 0.200 AC/hr (54 CFM), Construction: Average
i
Duet Load Fac or Scenarios for S stem
�....�� �ekc.. (1�i-t�[]uCt��U17aCe�Frru�iu�■ ,
Return
Attic
mm
u
C:1... \EXPRESS 1828 CALI LEFT PSL.rh9 Thursday, November 17, 2016, 11:37 AM
Room or
_Dud Name — --
System 1
Supply Runouts
Zone 1
1-Whole House
Other Ducts in System 1
Supply Main Trunk —
System 1
Heating Flow 413
Coolina Flow 1223
i
CA ...\EXPRESS 1828 CALI LEFT PSL.rh9
Minimum Ma)dmuml Rough. Design` SP
Source va,rtv! VcAwitvl Factori U1001 Loss
Built-in 450 750 0.01 0.1
Built -In 550 600 0.01 0..1
avc� Htg i ag Ad. tact
518.9. 413 _j 1,223 1
560.4 413'j 1,223
Thursday, Novemoer i r, /-u rv, r 1.,71 r,rvr
Elite Software Development,anp.
Rlivac Residential & Ught Commercial MVAC Loads �3
A/C Service Masters; LLC Expfess 1�828+Call Left Psl
_ Paga_5,
12A-v-o: Glazing-Uouole pane row-e \e _ u.ouj, UNOIaVIv
window, vinyl frame, u-value 0.34, SHGC 0.35
2A-v-d: Glazing -Double pane low-e (e = 0.60), sliding
glass door, vinyl frame, u-value 0.63, SHGC 0.32
1 U Door -Metal - Fiberglass Core
13AB-Ofcs: Wall -Block, no blanket or board insulation,
j filled core, siding finish
12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud
cavity, no board insulation, siding finish, wood studs
1613-38: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation
22A-pm: Floor -Slab on grade, No edge insulation, no
insulation below floor, any floor cover, passive, heavy
dry or light wet soil
Subtotals for structure:
People:
Equipment:
Lighting:
Ductwork:
Infiltration: Winter CFM: 102, Summer CFM: 54
Ventilation: Winter CFM: 0, Summer CFM: 0
System 1 Load Totals:
40.8
720
0
660
660
36.4
612
0
568
568
1236.1
6,334
0
3,936
3,936
313-1
798
0
612
612
1828
1,331
0
2,376
2,37E
199 6,575
17,562
5
0
11,067
3,135
0
31,764
0
0
0
i
0
10,532
10,532
1,000
1,150
2,150
1,020
3,563
4,583
0
0�
2,629
10,742
13,371
2,226
884
3,110
0
0_
0 I
6,875
26,871
33,746
l�l'IG{ifl 7"I ` ulcer 0.669
1 Supply CFM: 1,223 CFM Per Square ft.:
Square ft. of Room Area: 1,828 Square ft. Per Ton: 650
Volume (ft3) of Cond. Space: 16,087
; "S stern loads
Total Heating Required Including Ventilation Air: 31-1764 Btuh 31.764 MBH
Total Sensible Gain: 26,871 Btuh 80 %
Total Latent Gain: 6,875 Btuh 20 %
Total Cooling Required Including Ventilation Air: 33,746 Btuh 2.81 Tons (Based On Sensible + Latent)
Notes.
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
j Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
i
C:\ ...\EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
Rhvac Resl+
AIC'ServiCe.,h
I Palm Bay. FL
Sal & Ught Corm
a0s
i1 NVAC Loads
u�prrient Data ,_ SVste M- 7
j Cooling
j System Type:
Air Source Heat Pump
Outdoor Model:
25HBC536A**30
Indoor Model:
FV4CNB006
Tradename:
BASE 15 PURON HP
Outdoor Manufacturer:
CARRIER AIR CONDITIONING
Description:
Air Source Heat Pump
AHRI Reference No.:
3645941
Capacity:
36375
Efficiency:
15.5 SEER
Heating
System Type:
Air Source Heat Pump
j Model:
25HBC536A**30
Tradename:
BASE 15 PURON HP
Manufacturer:
CARRIER AIR CONDITIONING
Description:
Air Source Heat Pump
Capacity:
34000
Efficiency:
9 HSPF
This system's equipment.was selected in accordance with ACCA Manual S
t Manual S equipment sizing data: SODS: 90F, SOWS: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain:
26,871 Btuh, Lat. gain: 6,875 Btuh, Sen. loss: 31,764 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F,
TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1223 CFM, Req. htg. airflow: 413 CFM
Entering htg. coil DB: 70F, Clg. coil
i
C:1... \EXPRESS 1828 CALI LEFT PSL.rh9
Thursday, November 17, 2016, 11:37 AM
r Rh�vac�• ResidentiaE &'Light Commercial HVl
fA!' C Service Masters, LLC
Pa[m Bay,"FE_ 32909
System 1 Room Load burn,
�C Loads '
,oftware Development, Jnc.
Express 1828.Cali Left Psi
panda 7
---Zone 1-
1 Whole House 1,828 31,764 413 12-6 519 26,871 4,246 1,223 1,223
Duct Latent 2,629
1 26,871 6,875 1,223 1,223
System 1 total 1,828 31,764 413
System 1 Main Trunk Size: 20 in.
Velocity: 560 ft./min
Loss per 100 ft.: 0.040 in.wg
Coot; 9 S, stem Summary _
1000M s Trnr�i■
Net Required: 2.81 80% / 20% 26,871 6.
875
Actual:
3.03 88% / 12% 31,932 4,443 36;$75
�� ui"new Data
Heating System Cooling System
j Type: Air Source Heat Pump Air Source Heat Pump
Model: 25HBC536A**30 25HBC536A**30
Indoor Model: FV4CNB006
Brand: BASE 15 PURON HP BASE 15 PURON HP
i Description: Air Source Heat Pump Air Source
Heat Pump
Efficiency: 9 HSPF
Sound: 0 0
Capacity: 34,000 Btuh 36,375 Btuh
Sensible Capacity: n/a 31,932 Btuh
Latent Capacity: n/a 4,443 Btuh
i AHRI Reference No.: n/a 3645941
This system's equipment was selected in accordance with ACCA Manual SA WIDB: 70F Sen. gain:
Manual 8 equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, S: 75F, SIRH: 50%, ,
26,871 Btuh, Lat. gain: 6,875 Btuh, Sen. loss: 31,764 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F,
Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg, coil TD: 70F, Req. clg. airflow: 1223 CFM, Req. htg. airflow: 413 CFM
C:1... \EXPRESS 1828 CALI LEFT PSL.rh9 Thursday, November 17, 2016, 11:37 AM
�iVVf"'l a
a�ckr:lixi�i�carcivaararrrnra
Contractor Florida Breeze
Mechanical License # CAC1814113
Building Plan #
County, Town, Municipality, Jurisdiction
Header Information
REQUIRED ATTACHMENTS'
Manual A Form (and supporting worksheets):
or MAAE Form' (and supporting worksheets):
OEM performance data (heating, cooling, blower):
Manual D Friction Rate Worksheet:
Duct distribution system sketch:
Home Address (Street or Lot#, Block, Subdivision)
>iqn conattions
Winter Design Conditions
Outdoor temperature
42
OF
Indoor temperature
70
OF
Total heat loss
31764
Btu/h
Summer Design Conditions
Outdoor temperature
90
'F
Indoor temperature
75
OF
Grains difference 61
A Gr @ 50
% Rh
Sensible heat gain
.26871
Btu/h
Latent heat gain
6875
Btu/h
Total heat gain
33746
Btu/h
Heating Equipment Data
Equipment type Heat pump
Furnace. Heat pump. Boiler, etc.
Model 25HBC536A**30
Heating output capacity 34000 Btu/h
Heat pumps - capacity at winter design outdoor conditions
Auxiliary heat output capacity , Btu/h
Design airflow
External Static Pressure (ESP)
Component Pressure Losses (CPL)
Available Static Pressure (ASP)
ASP = ESP - CPL
Contractor's Printed Name
Contractor's Signature
Form
RPER 1.01
8Mar 10
ATTACHED
Yes OX No ❑
Yes ❑ No XX
Yes QX No ❑
Yes ❑ No 0
Yes ❑ No QX
Building Construction Information
Building
Orientation (Front door faces) South
North, East, West. South, Northeast, Northwest, Southeast, Southwest
Number of bedrooms 4
Conditioned floor area 1 828 Sq Ft
Number of occupants 5
Windows Roof
Eave overhang depth 2.7 Ft
Internal shade Eave
Blinds, drapes, etc Depth Window
Number of skylights 0
Cooling Equipment Data
Equipment type Heat pump
Air Conditioner, Heat pump, etc
Model 25HBC536A**30
Sensible cooling capacity
Latent cooling capacity
Total cooling capacity
CFM Longest supply duct:
IWC Longest return duct:
Kel
31932 Btu/h
4443 Btu/h
36375 Btu/h
Blower Data
Heating CFM 125 CFM
Cooling CFM 1285 CFM
Ft Duct Materials Used (circle)
Trunk Duct: Duct board, Flex, Sheet metal,
Ft Lined sheet metal, Other (specify)
IWC Total Effective Length (TEL) Ft
IWC Friction Rate: IWC
Friction Rate = (ASP x 100) + TEL
Branch Duct: Duct board, Flex, Sheet metal,
Lined sheet metal, Other (specify)
Date 7/10/2015
The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions.
' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions.
Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.
Air Conditioning Contractors of America
Manual S (Residential Equipment Selection)
Project Information Cooling Design Information
Name: Outdoor Design Temp: 91 °F db Summer
City: Outdoor Design Temp: 43 °F db IWinter
Stater � Aititude:— Altitude Adjustment: 1.00 Indoor Design Temp: 75 OF db 50 %RH 63 OF wb
Manual J Load Calculations
Total Load
Sensible
Latent
SHR Heat Loss
33746
26871
6875
0.796 L
Airflow Calculations
Design TD for Airflow
19
Design Sensible CFM
F 1286
r OEM Information
Manufacturer: lCarrier Furnace Model #:I AFUE:�
Coil or Fan -Coil Model #: FV4CNB006 —� Condenser Model #: 25HBC536A SEER: 15.5 HSPF: 9.00
(A) Manufacturer's Cooling Performance Data
Lower Return Air
Outdoor
Temperature =
95 (F db)
Entering Coil Temperature = 75 (F db)
CFM (F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rated CFM @ Rated RA Temperature
67
37.900
27,120
10.780
0.7156
Rated CFM @ Design RA Temperature
1050 63
35,204
31,056
4.148
0.8822
Rated CFM @ Rated RA Temperature
62
34,530
32,040
F 2.490
0.9279
(B) Manufacturer's Cooling Performance Data
Higher Return Air
Outdoor Temperature =
95 (F db)
Entering Coil Temperature = 75 (F db) CFM (F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rated CFM @ Rated RA Temperature
F 39,270
F 8.700
0.7785
Rated CFM @Design RA Temperature 1350 63
367694
35,266
T428
0.9611
Rated CFM @ Rated RA Temperature 62
367050
36,440
F -390
1.0108
Manufacturer's Cooling Performance Data (Interpolated)
Design Return Air
CFM (F wb)
Excess Latent Capacity Calculation
Capacity @ Design CFM / RA (F wb) 1285.7 63
Equipment Capacity as a % of Design
Outdoor Temperature = 95 (F db)
Total BTUH Sensible BTUH
Latent BTUH SHR
34.364
2,011 0.9447
+ -2.432
- -2,432
36,375 31,932
4,443 FO.878
107.79% 118.83%
64.63%
Manufacturer's Heat Pump Data
Capacity Capacity Balance Supplemental
@ 47 OF db @ 17 OF db Point Heat Required
34,800 18,820 -18.3 -15.87
Manufacturer's Furnace Data
Input Output Desired Calculated
FEATURES
Environmentally Sound Refrigerant Technology
• Puron®, chlorine -free non -ozone depleting refrigerant
• Thermostatic Expansion Valve (rXV) designed to maximize performance with Puron® refrigerant
Energy Efficient Operation
• Electronically Commutating Motor (ECM) operates efficiently at all speeds
• Maximizes efficiency of heating and cooling systems
• Ultra low power consumption during fan only operation
Indoor Weather Control
• Warm, comfortable heating air temperatures
• Unmatched humidity control, especially with Carrier's Thermidistat'° Control
Airflow and Sound Technology
• Diffuser air discharge section for high airflow efficiency and quiet, smooth operation
• High duct static capability
., _. qi c, u" Sr 1 r� alto. ._ - e, a- - u taau. 'e e ?'e3ia3
Condensate Control and Disposal Technology
• Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage
• Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance
• Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary
line conditions
• Tested for condensate disposal at conditions much more severe than those required by AHRI
• Primary and secondary drain connections to comply with HUD
• All pans constructed of an injection molded glass -filled polycarbonate engineered resin material, with brass drain connections.
• High density, super thick cabinetry insulation with vapor barrier
• Pre -painted galvanized sheet metal cabinet
Heat Transfer Technology
• Grooved copper tubing
• Lanced sine wave aluminum fins
• Discreet refined counter -flow refrigerant circuitry
• Bi-flow hard shut-off TXV metering device
• ArmorCoat' coil protection available
Quality Assisting, Ease of Installation and Service Features
• All units multipoise
• Provision made for suspending from roof or ceiling joints
• Modular cabinet on 003 thru 006 units
• Sweat connections for leak free service
• Multiple electrical entry for application flexibility (high and low voltage)
• Low voltage terminal strip, to safely hold connections within the cabinet
• Inspection plate on A -coil models for quick coil cleanliness inspection
• Cabinet construction features innovations designed to prevent cabinet sweating
Controls and Electrical Features
• Easy Select " Board to maximize comfort, efficiency, and safe heater airflow operation
• Easy plug connection provided for quick installation of accessory heater packages
• 40VA 208/230v transformer
• Replaceable 5-amp blade -type auto fuse protects against transformer secondary short
Filter Features
• Factory supplied filter
• Cleanable polyester filter media
• Filter "springs" out for easy access - no tools required
• Newly improved filter rack area - filter door insulation added for an improved air seal