Loading...
HomeMy WebLinkAboutICC-ES REPORTDIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 06 16 00—SHEATHING DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 25 00—WATER-RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: 07 27 00—AIR BARRIERS REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING ICC ICCi�g� 4 . C(4 ICC IGC Qk Look for the trusted marks of Conformity! File Copy "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" A Subsidiary of C ODE o' Ncie ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not 6CC" rd id specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as \ .� 9. to any finding or other matter in this report, or as to any product covered by the report. ro MPI aeer�ansecr, Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-1474 Reissued October 2016 This report is subject to renewal October 2018. www.icc-es.ora 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 25 00—Water-resistive Barriers/Weather Barriers Section: 07 27 00—Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012 and 2b09 International Building Codee (IBC) ■ 2015, 2012 and 2009 International Residential Code® (IRC) ■ 2015, 2012 and 2009 International Energy Conservation Code® (IECC) Properties evaluated: ■ Weather resistance ■ Air leakage 2.0 USES ZIP System® Wall Sheathing panels are used as combination wall sheathing, air barrier, and water -resistive barrier. This report recognizes the use of ZIP System® Sheathing, when installed with ZIP System TM flexible flashing seam tape, in walls of Type V construction (IBC) and dwellings under the IRC, and as an alternate to the water -resistive barrier required in Chapter 14 of the IBC and Chapter 7 of the IRC, and to the air barrier required by Sections R402.4 and C402.5.1 of the 2015 IECC (Sections R402.4 and C402.4.1 of the 2012 IECC; Sections 402.4.1 and 502.4.3 of the 2009 IECC). 3.0 DESCRIPTION 3.1 Sheathing Panel: The ZIP System® Wall Sheathing panel is an OSB wood structural panel having a laminated exterior facer. The Exposure 1 OSB complies with US DOC PS 2 for wood structural panels. The exterior facer is a medium -density, phenolic -impregnated, polymer -modified sheet material qualifying as a Grade D water -resistive barrier (required by Section 2510.6 of the 2012 and 2009 IBC). The panels are nominally 4 feet wide by 8, 9, 10, 11 or 12 feet long and have a square -finished -edge or machined -edge profile. When tested in accordance with ASTM E96 (water method), the polymer -modified sheet overlay has a minimum vapor permeance of 12 perms [68.6 X 10-11 kg/(Pa-S-m2)]. Equivalent Water Vapor Transmission rate (WVT) of the polymer -modified sheet overlay is 83.4 g/(24h-m2) when tested at 73.4°F (23°C). The water -resistive barrier and air barrier properties of the ZIP System® Wall Sheathing Panels are not affected when the panels are manufactured to comply as facing materials for SIPS in accordance with Section R610.3.2 and Table R610.3.2 of the 2015 IRC (Section R613.3.2 and Table R613.3.2 of the 2012 and 2009 IRC). 3.2 Seam Tape: The ZIP SystemTM seam tape is a self -adhering membrane tape consisting of acrylic adhesive laminated to a polyolefin backing. The tape is 0.012 inch (0.30 mm) thick with a minimum width of 3 /4 inches (95.2 mm), and comes inI rolls of various lengths. 4.0 INSTALLATION 4.1 General: Installation of ZIP System® Wall Sheathing panels must comply with the applicable code, this report and the manufacturer's published- installation instructions. The manufacturer's published installation instructions must be available at the jobsite during installation. 4.2 Application: 4.2.1 General: The ZIP System® Wall Sheathing panels must be attached to wall framing in accordance with the applicable code for wood structural panels, and in compliance with their panel span rating. The panels must be installed with the polymer -modified sheet overlay facing the exterior. In accordance with the manufacturer's published installation instructions, it is recommended that the square edges of the panels be installed with a gap ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or impliedas to any finding or other matter in this report, or as to any product covered by the report. Copyright m 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 6 ESR-1474 I Most Widely Accepted and Trusted Page 2 of 6 between adjacent panels and between panels and dissimilar materials. All ZIP System® Wall Sheathing panel seams must be sufficiently sealed with ZIP System seam tape. All overlay surfaces must be dry and free of sawdust and dirt prior to application of the ZIP System seam tape. The ZIP SystemT"' seam tape must extend a minimum of 1 inch (25.4 mm) past the panel edge T-joint intersections and, must be centered within 1/2 inch (12.7 mm) over the middle of panel seams. The tape must be pressed firmly to adhere to the surfaces and seal the seams. Wrinkles in the ZIP System M seam tape are acceptable unless they create a leak path to the panel seam. 4.2.2 Flashing: Flashing complying with the applicable code must be installed at the perimeter of door and window assemblies, penetrations and terminations of exterior wall assemblies, exterior wall intersections with roofs, chimneys, porches, decks, balconies, and similar projections, and at built-in gutters and similar locations where moisture could enter the wall. An adhesive -backed flashing tape recognized in a current ICC-ES evaluation report must be installed to seal all ZIP System Wall Sheathing flashing joints. Penetration items must be sealed to the panels. The adhesive -backed flashing tape must comply with the ICC-ES Acceptance Criteria for Flexible Flashing Materials (AC148) and must be installed in accordance with the manufacturer's published installation instructions. See Figures 1 through 7 of this report for typical flashing, water -resistive barrier and air barrier assembly installation details. 4.2.3 Air Barrier Assembly: ZIP System® Wall Sheathing fastened to maximum 24-inch-on-center (610 mm), wood wall framing, using minimum 6d nails spaced at 6 inches (152 mm) around panel edges and at 12 inches (305 mm) in the field, leaving a 1/8-inch (3.18 mm) gap between panels, forms an air barrier assembly when the gaps between panels and the perimeter of penetrations are sealed with ZIP SystemTm seam tape as required by Section 4.2.1. The assembly has demonstrated a maximum air leakage of 0.0072 cfm/e [0.037 U(S.M)] infiltration and 0.0023 cfm/ft2 [0.012 U(s•m)] exfiltration at a pressure differential of 1.57 psf (75, Pa) when tested in accordance with ASTM E2357. 6.0 CONDITIONS OF USE The ZIP System Wall Sheathing panel and tape system described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 This evaluation report and the manufacturer's published installation instructions, when required by the code official, must be submitted at the time of permit application. 6.2 The ZIP System® Wall Sheathing panels must be manufactured, identified and installed in accordance with this report and the manufacturer's published installation instructions. In the event of a conflict between the instructions and this report, this report must govern. 5.3 The ZIP System® Wall Sheathing panels must be covered with a code -complying exterior wall covering, or one that is recognized in a current ICC-ES evaluation report. 5.4 The OSB sheathing must comply with US DOC PS-2. 5.5 Fire -resistance -rated construction is outside the scope of this report. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Water -resistive Membranes Factory - bonded to Wood -based Structural Sheathing, Used as Water -resistive Barriers (AC310), dated May 2008 (editorially revised August 2015). 6.2 Air leakage data in accordance with ASTM E2357. 7.0 IDENTIFICATION Each ZIP System® Wall Sheathing panel described in this report must bear a label that includes the manufacturer's name (Huber Engineered Woods LLC), the product name, nominal panel thickness, the evaluation report number (ESR-1474), and the words "Mill 229, Crystal Hill, Virginia"; "Mill 228, Easton, Maine"; "Mill 227, Commerce, Georgia"; or "Mill 290, Broken Bow, Oklahoma." The OSB sheathing must also bear a label demonstrating compliance with US DOC PS 2 from an approved inspection agency. The ZIP System TM seam tape roll must be labeled with the ZIP System logo and the evaluation report number ESR-1474 (see Figure 8). ESR-1474 I Most Widely Accepted and Trusted Page 3 of 6 GUMDE ONSIOE L0W-PRE5%FM P�YIdtEMANE WNIM SILL� FOAM Oil CAULKING BY FLASHING NAANTACTUPa .T ADHESIVE -BACKED FOAMING TAM ROUM FRAMING - zip "Yo" WALL SHEAIHNG SILL SECTION JAMB SECTION HEADER SECTION FIGURE 1—TYPICAL CROSS SECTIONS OF FLANGED WINDOW ' ESR-1474 I Most Widely Accepted and Trusted Page 4 of 6 2P SYSTE0 ma-mEAT"HG ADHEDILE-BACRED- FLA91VG TAPE - ROUGH FRAIING CAIAN6JG I L W -IRE roLwRETxane RGID HEAD -- _ FiA"..dittiG OUT.rADE j ME � H400W HEAD Y SILL SECTION HEADER SECTION WINDOW JAMB ZIP SYSTEM' ADHESIVE BACKED WALL SHEATHING FLASHING TAPE OUTSIDE CAULKING ROUGH OPENING SI No o INSIDE LOW-PRESSURE POLYURETHANE FOAM JAMB SECTION FIGURE 2—TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW 'ESR-1474 I Most Widely Accepted and Trusted Page 5 of 6 ZIP SYSTEMTM WALL SHEATHING WALL FRAMING ADHESIVE -BACKED FLASHING TAPE METAL FLASHING -FLASHING FASTENER ADHESIVE -BACKED FLASHING TAPE ROOF UNDERLAYMENT (FELT) F_- ROOF SHEATHING ROOF JOIST FIGURE 3-ROOF-WALL INTERSECTION (OPTION 1) FIGURE 5-TYPICAL WALL -SILL INTERSECTION AND FLASHING DETAILS FOR BRICK SIDING ZIP SYSTEMT111 WALL SHEATHING WALL FRAMING ADHESIVE -BACKED FLASHING TAPE FLASHING FASTENER COUNTER -FLASHING BASE FLASHING FLASHING FASTENER ADHESIVE -BACKED FLASHING TAPE r- ROOFUNDERLAYMENT (FELT) r-- ROOF SHEATHING ROOF JOIST FIGURE 4-ROOF-WALL INTERSECTION (OPTION 2) FIGURE 6-TYPICAL WALL -SILL INTERSECTION AND FLASHING DETAILS FOR LAPPED SIDING ESR-1474 I Most Widely Accepted and Trusted Page 6 of 6 FIGURE 7—INSTALLATION AT PENETRATION OPENING (NON -FIRE -RESISTANCE RATED) FIGURE 8—LABELING FOR THE ZIP SYSTEM SEAM TAPE ROLL IMES Evaluation Report ESR-1474 FBC Supplement Reissued October 2016 This report is subject to renewal October 2018. www.icc-es.orq 1 (800) 423-6587 1 (662) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 25 00—Water-Resistive Barriers/Weather Barriers Section: 07 27 00—Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System® Wall Sheathing panels, recognized in ICC-ES master evaluation report ESR-1474, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code —Building ■ 2014 Florida Building Code —Residential 2.0 CONCLUSIONS The ZIP System® Wall Sheathing panels, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, comply with the 2014 Florida Building Code —Building and the 2014 Florida Building Code —Residential, provided the design and installation are in accordance with the International Building Code® provisions noted in the master report. Use of the ZIP System® Wall Sheathing panels for compliance with the High -Velocity Hurricane Zone provisions of the 2014 Florida Building Code —Building and the 2014 Florida Building Code —Residential has not been evaluated, and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued October 2016. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributer not specifically addressed, nor are they to be construed MWlk as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright© 2016 [CC Evaluation Service, LLC. All rights reserved. Page 1 of 1 IMES Environmental Report VAR-1012 Reissued September 2015 This report is subject to renewal September 2017. www.icc-es.orgleR 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 0612 00—Structural Panels Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation Section: 07 25 00—Water-Resistive Barriers/Weather Barriers Section: 07 27 00—Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC 10925 DAVID TAYLOR DRIVE CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ADVANTECH® (AT -SERIES) SHEATHING SPAN; ADVANTECH® (AT -SERIES) FLOOR SPAN; ZIP SYSTEM® ROOF SHEATHING; ZIP SYSTEM® WALL SHEATHING; ZIP SYSTEMS R-SHEATHING (INSULATING SHEATHING) 1.0 EVALUATION SCOPE Compliance with the following evaluation criteria: • ICC-ES Environmental Criteria for Determination of Bio- based Material Content (EC102), dated March 2012. • ICC-ES Evaluation Guideline for Determination of Source of Recovery, Extraction, Harvest and Manufacture for Materials or Products (EC114), dated March 2012 • ICC-ES Environmental Criteria for Determination of Formaldehyde Emissions of Composite Wood and Engineered Wood Products (EC108), dated March 2012. • ICC-ES Environmental Criteria for Determination of Certified Wood and Certified Wood Content in Products (EC109), dated March 2012. Compliance eligibility with the applicable sections of the following green building rating systems, standards and codes: • 2012 International Green Construction Code (IgCC) (see Table 2 for details) • 2013 California Green Building Standards Code (CALGreen), Title 24, Part 11 (see Table 3 for details) • National Green Building Standard (ICC 700-2008) (see Table 4 for details) • National Green Building Standard (ICC 700-2012) (see Table 5 for details) • LEED for Homes 2008 (see Table 6 for details) • LEED v4 for Homes Design and Construction (see Table 7 for details) • LEED 2009 for New Construction and Major Renovations (see Table 8 for details) LEED 2009 for Schools New Construction and Major Renovations (see Table 9 for details) • LEED v4 for Building Design and Construction (BD+C) (See Table 10 for details) • ANSI/GBI 01-2010 — Green Building Assessment Protocol for Commercial Buildings (see Table 11 for details) 2.0 USES AdvanTech® (AT -Series) Sheathing_ Span, AdvanTeche (AT -Series) Floor Span, ZIP System Roof Sheathing and ZIP System® Wall Sheathing are used for a variety of interior and exterior framing and sheathing applications. ZIP System® R-Sheathing panels are used as combination wall sheathing and continuous insulation in conventional wood -framed wall construction. 3.0 DESCRIPTION AdvanTech® (AT -Series) Sheathing Span and AdvanTech® (AT -Series) Floor Span wood structural panels are Exposure 1 oriented strand board (OSB) panels manufactured with strands from a single wood species or a combination of wood species blended with an exterior -type adhesive system to comply with U.S. DOC PS-2 and the applicable ICC-ES report as indicated in Table 1. ZIP System® Roof Sheathing and ZIP System® Wall Sheathing wood structural panels are OSB panels with laminated, resin -impregnated, polymer -modified sheet material manufactured to comply with U.S. DOC PS-2 and the applicable ICC-ES reports as indicated in Table 1. The panels are installed with ZIP System® self -adhering membrane tape. The tape is outside the scope of this evaluation report. ZIP System® R-Sheathing is an insulated sheathing made by combining 7/16-inch-thick ZIP System® Wall ICC-ES Verification ofAttributes Reports are issued under the ICC-ES VAR Environmental Program. These reports are not to be contused as representing aesthetics or any other n4 attributes not specifically addressed, nor are they to be consented as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC O , Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright O 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 6 a VAR-1012 I Most Widely Accepted and Trusted Page 2 of 6 Sheathing as described in ESR-1474 with a layer of 5.2 ICC-ES EC114. [Evaluation applies to IgCC Section maximum 1-inch-thick (25.4 mm) rigid foam plastic 505.2.5; CALGreen Section A5.405.1; ICC 700-2008 insulation laminated to the interior face with PVA adhesive. Section 608.1; ICC 700-2012 Sections 609.1, Refer to ESR-3373 for additional product description. 11.609.1 & 12.1(A).609.1; LEED Homes MR 2.2(c); 4.0 CONDITIONS LEED v4 Homes MRc3; LEED NC MR 5; LEED Schools MR 5; LEED v4 BD+C MRc3; ANSI/GBI 01- 4.1 Code Compliance: 2010 Section 10.1.4.1]. AdvanTech® (AT -Series) Sheathin% Span, AdvanTech® (AT -Series) Floor Span, ZIP System Roof Sheathing, ZIP System® Wall Sheathing and ZIP System® R-Sheathing have been evaluated for compliance with the requirements of the International Codes as listed in Table 1 of this report. 4.2 Green Rating Systems, Standards and Code Eligibility: The information presented in Tables 2 through 11 of this report provides a matrix of areas of evaluation and corresponding limitations and/or additional project -specific requirements, and offer benefit to individuals who are assessing eligibility for credits or points. 5.3 ICC-ES EC108 [Evaluation applies to IgCC Section 806.1; ICC 700-2008 Section 901.4(6); ICC 700-2012 Sections 901.4(6) & 11.901.4(6); LEED NC EQ 4.4; LEED Schools EQ 4.4; LEED v4 BD+C EQc2]. 5.4 ICC-ES EC109 [Evaluation applies to ICC 700-2008 Section 606.2; ICC 700-2012 Sections 606.2(2), 11.606.2(2) & 12.1(A).606.2; ANSI/GBI 01-2010 Section 10.3.2.1]. 5.6 Documentation establishing and documenting all major sources of primary. manufacturing energy [Evaluation applies to ICC 700-2008 Section 606.3; ICC 700-2012 Sections 606.3 & 11.606.3]. The final interpretation of the specific requirements of the 5.6 ICC-ES ESR-1474 documenting that ZIP System Wall respective green building rating system, standard and/or Sheathing is equivalent to a code -prescribed water - code rests with the developer of that specific rating system resistive barrier [Evaluation applies to CALGreen or standard or the Authority Having Jurisdiction, as Section 5.407.1; ICC 700-2008 Section 602.9; ICC applicable. 700-2012 Section 602.1.8]. Compliance with items noted as "Verified Attribute" is subject to any conditions noted in the tables. Decisions on compliance with those items noted as "Eligible for Points" in Tables 2 through 11 rests with the user of this report, and those items are subject to the conditions noted. The user is advised of the project -specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. Rating systems or standards often provide supplemental information as guidance. 5.0 BASIS OF EVALUATION The information in this report, including the "Verified Attribute," is based upon the following supporting documentation: 6.1 ICC-ES EC102 [Evaluation applies to IgCC Section 505.2.4; CALGreen Sections A4.405.4 & A5.405.2; ICC 700-2008 Section 606.1(2); ICC 700-2012 Sections 606.1, 11.606.1 & 12.1(A).606.1; ANSI/GBI 01-2010 Section 10.1.2.2]. 6.7 Refer to ICC-ES ESR-1474 for evaluation of the ZIP System Wall Sheathing as an air barrier assembly [Evaluation applies to IgCC Section 605.1.2.1.1; ICC 700-2008 Section 703.2.1; ICC 700-2012 Sections 701.4.3.2, 11.701.4.3.2 & 12.1.701.4.3.1; LEED Homes EA 3; LEED v4 Homes EAc7]. 6.0 IDENTIFICATION AdvanTech® (AT -Series) Sheathin% Span, AdvanTech® (AT -Series) Floor Span, ZIP System Roof Sheathing, ZIP System® Wall Sheathing and ZIP System® R-Sheathing products are identified with a stamp noting the manufacturer's name (Huber Engineered Woods, LLC) and address, the product name the manufacturing location, the ICC-ES evaluation report number (if applicable), and the name or logo of the inspection or grading agency. The report subjects are also identified on the product and/or packaging with the VAR Environmental Report number (VAR-1012) and the ICC-ES SAVE Mark, as applicable. TABLE 1—REFERENCE STANDARD OR EVALUATION REPORT NUMBER FOR HUBER ENGINEERED WOODS LLC PRODUCTS PRODUCT REPORT NUMBER/ REFERENCE STANDARD AdvanTech® AdvanTech® (AT -Series) Sheathing Span (AT -Series) Floor Span ESR-1785 ZIP System® Roof Sheathing ESR-1473 & ESR-2227 ZIP System® Wall Sheathing ESR-1474 & ESR-2227 ZIP System® R-Sheathing ESR-3373 e VAR-1012 I Most Widely Accepted and Trusted Page 3 of 6 TARI FS 7 THRI11111,14 11 Section Section Intent Possible Conditions of Use to Qualify AdvanToch AdvanTech ZIP System Rcof ZIP System Wall ZIP System Number Points Sheathing Flooring RSheathing Sheathing Sheathing TABLE 2—SUMMARY OF AREAS OF ELEGIBILITY WITH 2012INTERNATIONAL GREEN CONSTRUCTION CODE 505.2.4 Bio-based products WA All Huber mod products are qualified as bio-based. • • • • Os Products shall be recovered, harvested, extracted 8 manufactured within a 500 mile (BOO tan) radius of the building site. Where only a portion of a material or product is recovered, harvested, extracted 8 manufactured within 500 miles (800 or), only 505.2.5 Indigenous materials N/A that portion shall be included. Where resources are transported by water or rail, the O O O O il distance to the building site shall be determined by multiplying the distance that the resources are transported by water at rail by 0.25, 8 adding that number to the distance transported by means other than water or ralf I I 605.1.2.1.1 Air barrier installation WA Install the system in accordance with the manufacturers installation Instructions and `. t- - _ ' r" ICC-ES evaluation report ESR-1474. G • • 806.1 Formaldehyde emissions WA Huber wood structural panels comply with US DOC PS 2 (See Table 1 of this report and are exempt from formaldehyde emissions testing. • • • • Os TABLE 3—SUMMARY OF AREAS OF ELEGIBILITY WITH 2O13 CALIFORNIA GREEN BUILDING STANDARDS CODE A5.405.1 Regional materials Verity local products that are extracted, processed and manufactured within Elective California or 500 miles 805 Ion of the job sites O O O O Y,^ A4.405.4 A5.405.2 Bio-based materials All Huber wood products are qualified as bio-based. • •, • • Os A4.405.4(3) A4.405.4(5) Renewable sources Materials from renewalble sources (such as engineered wood). • • • • Os A5.405.2.1 Certified Wood Under review by California Building Standards Commision' N/A WA WA WA WA 5.407.1 Water-resistant exterior wall assembly Mandatory Huber products provide awater-resistant eztericrwall envelope. a '+-. O O 4.504.5 5.504.4.5 Composite wood product emissions EWP products do not apply to the composite wood product definition! TABLE 4—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD (ICC 700-2008) 6029 Water -resistive barrier Mandatory Install a water-restsMe barrier and/or drainage plan system behind exterior veneer and/or siding. • • Ttw types of biobased materials are used, each for To earn 6 points products must beat least 1%of the construction material cost AN 606.1(2) more than 1%of the projects projected building 6 another bio-based product at 1% of material cost must be used. 1 or 3 points are • • • • Os material cost available for greater than 0.5%. Two certified wood -based products are used for To earn 3 points a second certified wood product must also be used as a minor 606.2(1) minor elements of the building, such as all wails, 3 element' • • • • Os floors or roof Two certified mod -based products are used for To earn 4 points a second certified wood product must also be used as a major 606.2(2) major elements of the building, such as all walls, 4 element • • • • W floors or roof Materials are used for major wmpcnents of the building that are manufactured using minimum of 2 To fi06.3 33%0l primary manufacturing processsenergys, each earn 6 points the products must be used for at least 3 major components of the • • • • Os derived from renewablee ssourcecombustible waste 6 max building. 2 points may be earned when used for each major component sources, or renewable energy credits _Verifiede =This provision does not apply to this product Note; Footnotes are located after Table 11. VAR-1012 I Most Widely Accepted and Trusted Page 4 of 6 TABLES 2 THROUGH 11 Mnntinnedl Section Section Intent Possible Conditions of Use to Qualify AtivanTuch AdvanTech ZIP System Roof ZIP System Wall ZIP System Number Points Sheathing Fleoring RSheathing Sheathing Shaathing TABLE4—SUMMARYOF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD (ICC 700-2008) (Continued) 608.1 Indigenous materials 2 each To earn 2 points verify local products are ang nated, produced, grow naturally of Ayes 10 max occur natural) within 500 miles 805 km of'ob site° O O O O Insulation and air sealing is installed in accordance with all the fallowing, as 703.2.1 Insulation and air sealing 3 15 max applicable: (1) third -party verification performed 15 cats, p; n • r O O (2) no third -party verification performed 3 pis Structural plywood used for floor, wall, and/or roof sheathing compiles with DOC PS 1 and/or DOC PS 2 OSS used for floor, wall, and/or roof sheathing 7o meet ta mipimum of 85%of OSB or plywood in the building must consist of this his 901.4(1) complies with DOC PS 2. Panels are made with Mandatory Huber products. • • • • • moisture -resistant adhesives and the trademark indicates the adhesives are Exposure t or Exterior (plywrocd) and Exposure 1 (OSB) 901.4(6) products, which can Include structural wood lramin mod framttlnging 4 A minimum of 85 % of product in the building are the identified Huber products. • • • • •5 TABLE 5—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD (ICC 700-2012) 6021.8 Water -resistive barter MandatoryT-+' Install awater-resmilve barrier and/or drainage fg ans system behind exterior veneer r '.5 and/or siding. • • 606.1(2) Two types of biobased materials are used, each for To earn 6 paints products must be at least 1%of the construction material cost AN 11.606.1(b) mare than 1%of the projects projected building 6 another biobased product at 1%of material cost must be used. 1 or 3 points are • • • • Os 12.1 A .606.1 material cost available for greater than 0.5%. fi06.20) Two certified woad -based products are used for To earn 3 points a second caNfed mod product must also be used as a minor 11.606.2(1) minor elements of the building, such wall trim, 3 element r • • • • Os .1 12.t A.606or cabinetry, millwork 606.2(2) Two cartified wood -based products are used for To cam 4 points a second certified wood product must also be used as a major 11.606.2(2) major elements of the building, such as all walls, 4 element r • • • • Os 12.1 A.606.2 Ifloom or roof I Materials are used for major components of the 606.3 building are manufactured using a minimum of 33% 2 each To earn 6 points the proe useeast the ducts must be for at l3 major components of 11.606.3 of primary manufacturing process energy derived 6 max building. 2 paints may be earned when used for each major component. • • • • Os from renewable sources, combustible waste sources, or renewable energy credits To earn 2 points verify material is produced, grows naturally, ar occurs naturally within 500 miles (805 km) of the job site if transported by truck or 1500 miles (2414 609.1 Regional materials 2 each km) if transported for at least 80% of the total distance by rail or water. Products Iha 10 max are assembled or produced from multiple raw materials qualify if the weighted O O O O average (by weight or volume) of the distance the raw materials have been trainsporteLd meet the distance criteria? 701.4.3.2 Insulation and air sealing is installed In accordance with ail the following, as v ,R,s �, 11.701.4.3.2 Insulation and air sealing 3 15 max applicable: (1) third -party verification performed 15 pts, � , , µ O O 121.701.4.3.1 (2) no third -party verification performed 3 pts Structural plywood used for floor, wall, and/or roof sheathing compnes with DOC PS 1 and/or DOC PS 901.4(t) 2. OSB used for floor, wall, and/or roof sheathing 11.901.4(1) complies with DOC PS 2. Panels are made with Mandatory To meet this a minimum o185% of OSB or plywood In the building must consist of • • • • • 12.1.901.4(1) moisture -resistant adhesives 8 the trademark Huber products. Indicates the adhesives are Exposure 1 or Exterior (plywood) 8 Exposure 1 (OSB) 901.4(6) Nonromi rig products, which can Include structural 4 A minimum of 85%of product in the building are the Identified Huber products. • • • • Os 11.901.4 6 waod framing oy,u — Pam • = Verified attribute = This provision does not apply to this product Note: Footnotes are located after Table 11 VAR-1012_I_ Most Widely Accepted and Trusted Page 5 of 6 TABLES 2 THROUGH 11 (Continued) Section Possible AdvanTech AdvanTech ZIP System ZIP Syatem ZIP System Number Saction Intent Points Conditions of Use to Qualify for Points Sheathing Flooring Roof Wall RSheathing Sheathing Sheathing TABLE 8—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED FOR HOMES 2008 EA 3 Air Infiltration 3 max To earn 2 or 3 points meet the air leakage requirements shown O O In Table 17 of the credit, as applicable. � � MR 21 FSC certified tropical wood 0.5 each 8 max To earn 0.5 point per component use FSC-certified tropicalwaoo? 2 2 2 2 2 Environmentally preferable products for roof, wall 8 0.5 each To earn points use products that are extracted, processed and manufactured within MR 2.2(c) floors; Intenor 8 exterior framing 8 sheathing 8 in 500 miles (805 km) of the site for a minimum of 90%(by weight or volume of the cam nent° O O O O g +� TABLE 7—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED v4 HOMES EAc7 Air Infiltration 2 max To earn 1 or 2 points based on air leakage rates determined by testing and 1 rg O O verifica0on. ,, ,� MR FSC certified tropical wood Prerequesite All wood must be nontropical or certified by FSC or USGSC-approved equivalent? 2 2 2 2 2 Upton o earn points use framing that Is extracted, processed and manu acturec Environmentally preferable products for roof, wail 8 0.5 each within 100 miles (160 km) of the site for a minimum of 50%(try weight or volume) of O O O O MRc3 floors; Interior 8 exterior framing 8 sheathing 8 max Option 2: Use mod products certified by FSC or USGSC-approved equivalent! 2 2 2 2 02 EOc2 Low emitting materials 1 earn 1 point use wood composite products contaning no -added urea- • .5 foTo . deh de resins. TABLE B—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED 2009 FOR NEW CONSTRUCTION AND MAJOR RENOVATION MR 5.1 Regional materials (10 %of content) 1 To earn 1 point use products that are extracted, processed and manufactured withir 500 miles (805 km) of the side for a minimum of 10 % (by cast) of total materials O O O O MR 5.2 Regional materials (20%of content) 2 value. To earn 2 points use a minimum of 20%6 O O O O ' y MR 7 Certified wood 1 To earn 1 point use a minimum 50% (based on cost) of wood -based 2 2 2 2 2 materials/products certified to FSC re ulmments2 EO 4.4 Lowernn ing materials 1 To earn 1 point use wood composite wood products containing no -added urea- . • 05 formaldehyde resins. TABLE 9—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED 2009 FOR SCHOOLS NEW CONSTRUCTION AND MAJOR RENOVATION MR 5.1 Regional materials (10 %of content) 1 To earn 1 point use products that are extracted, processed and manufactured within O O O O 17 500 miles (805 km) of the site for a minimum of 10% (by cost) of total materials O O 0 O MR 5.2 Regional materials (20%of content) 2 value. To earn 2 points use a minimum of 20%6 MR 7 Certified wood 1 To earn 1 point use a minimum 50% (based on cost) of wood -based 2 2 2 2 2 materials/products certified to FSC re uirements° EO 4.4 Low emitting materials 1 To earn 1 point use wood composite wood products containing no -added urea- 05 formaldehyde resins. TABLE 10—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED v4 BUILDING DESIGN AND CONSTRUCTION (BD+C) MRc3 Sourcing of raw materials- certification of rimmod 1 Option Use wood -based matenals/products certified by FSC or USGBC-approved 2 2 2 2 02 products equivalerre Products meeting the requirements of MRc3 Option 2 may be eligible for additional MRc3 Sourcing of raw materials - source location WA credit based on source location (extraction, manufacture and purchase point) based a 8 s s on location relative to profect site28 IEOc2.2 Low emitting materials NIA ENP and lumber products do not apply to the composite mod product definiticii O = Eligible for points o = Verified attribute VftU9AW-MI= This provision does not apply to this product Note: Footnotes are located after Table It VAR-1012 I Most Widely Accepted and Trusted Page 6 of 6 TAR[ FS 2 THRf111P,H 11 /Cnnfimtadl Section Section Intent Possible Conditions of Use to Qualify for Points AdvanTech Advan h ZIP System Roof ZIP System Wall ZI System Number Palnfs Sheathing Flooring Sheathing Sheathing RSheathing TABLE 11—SUMMARY OF AREAS OF ELEGIBILITY WITH ANSUGBI 01-2010 — GREEN BUILDING ASSESSMENT PROTOCOL FOR COMMERCIAL BUILDINGS 10.1.22 Biabased Products- building assemblies 7 max All Huber wood products are qualified as blabased 05 To earn credits use products that are extracted, processed and manufactured within 10.1.4.1 Regional Materials -building assemblies 5 max 500 miles (805 km) of the site for a minimum of 90%(by weight or volume of the O O O O component' 10.3.21 Certified wood 6 max Between 10%and 60%or more of wood -based products wed in the building are third party certified. . Os Q = Eligible for points • = Verified attribute This provision does not apply to this product Footnotes, tCertifica8on Is required of the manufacturer only. Vendor Chain of Custody is not required to quality for this point 'Forest certification credit for LEED 2009 resources FSC exclusively and for LEED v4 resources either FSC or USGBC-approved equivalent. Contact USGBC for a list of approved equivalent programs. 'CGBSC recognizes importance of use of certified forest products however the specific requirements are currently under development 'This area is not be confused with the provisions of EQ 4.4 In LEED (Table 4) because the California Air Resources Board (CARE) does not regulate engineered wood product emissions. 'Erigibility applies only to the wood -based sheathing portion of the panel. 'Regional material calculations based on project location provided by Huber upon request. WA = Not applicable DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 06 16 00—SHEATHING DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 30 05—ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+TM ROOF SHEATHING ICC ICC ICC k429� PMG LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not SA„ C" specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a t recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as AM A-MW G9,9 to any finding or other matter in this report, or as to any product covered by the report. C �a�aa cCN Copyright © 2015 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-1473* Reissued September 2015 . This report is subject to renewal September 2017. www.icc-es.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the Internatiohal Code Council® DIVISION: 06 00 00—WOOD, PLASTICS, AND COMPOSITES Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+TM ROOF SHEATHING 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012 and 2009 International Building Code® (IBC) ■ 2015, 2012 and 2009 International Residential Code® (IRC) ■ 2013 Abu Dhabi International Building Code (ADIBC)t TThe ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: ■ Structural —wind uplift resistance ■ Nonclassified roof covering ■ Classified roof covering ■ Weather resistance 2.0 USES ZIP System® and ZIP System+TM roof sheathing panels are used as combination roof sheathing and roof underlayment. KiG>•b *•33124101N The ZIP System® and ZIP System+TM roof Sheathing panels are wood structural panels having a laminated facer. The ZIP System+TM panels are manufactured using a different resin than the Zip System® panels.. The panels are installed with a proprietary seam tape, which allows the systems to be used as an alternate to the underlayment required in Chapter 15 of the IBC and Chapter 9 of the IRC. The OSB substrate complies with U.S. DOC PS-2 for wood structural panels and is overlaid on one side with a medium -density, phenol -impregnated, polymer -modified sheet material. The standard -size panels are nominally 4 feet by 8 feet. Oversize panels, wider than 4 feet (1219 mm) or longer than 8 feet (2438 mm), or both, are also produced. The panels are available with either a square -finished -edge profile a tongue -and -groove edge profile or a machined edge profile. The proprietary seam tape is a self -adhering sheet -type membrane consisting of acrylic adhesive laminated to a polyolefin backing, and the face of the tape is labeled with ESR-1473. The tape is 0.012 inch thick (0.30 mm) with a minimum width of 3 inches (76.2 mm), and comes in rolls of varying length. 4.0 INSTALLATION 4.1 General: Installation of ZIP System® and ZIP System+TM roof sheathing must comply with the applicable code, this report and the manufacturer's published installation instructions. The installation instructions are to be available at the jobsite at all times during installation. The instructions within this report must govern if there are any conflicts between the manufacturer's published instructions and this report. 4.2 Application: The ZIP System® and ZIP System+TM roof sheathing panels must be installed with the longer dimension perpendicular to the roof framing and fastened to the roof framing in accordance with the applicable code for wood structural panels. The panels must be installed in accordance with the panel span rating as shown on the panels. All corners are to be securely fastened. Tongue - and -groove and machined edge panels are designed to provide the correct gap size at the panel edges during installation. Squared -edged panels must be spaced apart a minimum of 1/9 inch (3.18 mm) at the time of installation. End joints of adjacent panel runs must be staggered. The panel must be installed with the laminated phenol - impregnated polymer -modified sheet material facing to the exterior. All ZIP System® and ZIP System+TM roof sheathing seams must be sealed with the Zip System® tape. All overlay surfaces must be free of any significant presence of debris particles or sawdust prior to installation of the ZIP System tape. Overlay surfaces must be void of any free water prior to application of the ZIP System® tape. The ZIP System® tape edges must be sealed and the tape is to be centered within +/- 1/2 inch �12.7 mm) of all panel edge seam centers. All ZIP System and ZIP System+TM 'Revised November 2015 /CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed rM as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as - — to any finding or other matter in this report, or as to any product covered by the report. en:o au Copyright 0 2015 ]CC Evaluation Service, LLC. All rights reserved. Page 1 of 2 ESR-1473 I Most Widely Accepted and Trusted Page 2 of 2 roof sheathing surface defects, openings, cracks, etc., that completely penetrate the overlay and substrate, and caused by handling or construction work, must be covered with the ZIP System® tape. The ZIP System® tape must extend a minimum of 1 inch (25.4 mm) past the panel edge T-joint intersections. The ZIP System® tape must be adhered to the ZIP System® and ZIP System+TM roof sheathing. Wrinkles in the ZIP System seam tape are acceptable unless they create a leak path to the panel seam. 4.3 Roof Assemblies 4.3.1 Classified Roof Coverings 4.3.1.1 Class A: Underlayment is not required for a minimum 1/2-inch thick Zip System+Tm roof sheathing with Class A asphalt glass fiber mat shingles. 4.3.1.2 Class B: Underlayment is not required for a minimum 7/16-inch thick Zip System® roof sheathing with Class A asphalt glass fiber mat shingles. 4.3.2 Nonclassified Roof Coverings: The ZIP System® and ZIP System+Tm roof sheathing panels are limited to installation on buildings permitted to have nonclassified roof coverings using code -complying asphalt -fiberglass shingles, metal shingles, metal panels, wood shakes, wood shingles, built-up roofing, slate and slate -type shingles, and clay and concrete tile roof coverings. Roof coverings may be applied directly to the taped ZIP System® and ZIP System+Tm roof panels unless multi -layer underlayments are required. 4.4 Wind Uplift Resistance: Wind uplift design loads and ZIP System® and ZIP System+Tm roof wood structural panel allowable uplift resistance shall be determined in accordance with Sections 1609 and 2304.8.2 of the 2015 IBC or 2304.7.2 of the 2012 and 2009 IBC and Section R301.2.1 of the IRC. Roof coverings must be fastened to the sheathing with mechanical fasteners sufficient to resist the design uplift load. 5.0 CONDITIONS OF USE The ZIP System® and ZIP System+Tee roof sheathing panels described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 This evaluation report and the manufacturer's published installation instructions, when required by the code official, must be submitted at the time of permit application. 5.2 The ZIP System® and ZIP System+Tm roof sheathing panels must be manufactured, identified and installed in accordance with this report and the manufacturer's published installation instructions. 5.3 The ZIP System® and ZIP System+TM roof sheathing panels are limited to code -approved structural use for wood structural panels with either a 24/16, 32/16 or 40/20 span rating. 6.4 In jurisdictions enforcing the IBC, the roof covering system incorporating the panels is limited to installations in the following construction types: • Type III-B and Type V-B • Type III -A or Type V-A under the conditions specified in footnote d of IBC Table 601 • Type III -A or Type V-A under the conditions specified in footnote b of IBC Table 601, for occupancies other than Group F-1, H, M and S-1 In jurisdictions enforcing the IRC, the roof covering system incorporating the panels may be installed on structures constructed in accordance with the IRC. 6.5 Enclosed attics and rafter spaces must be ventilated in accordance with the applicable code, except where unvented conditioned attic assemblies are permitted by 2015 and 2012 IRC Section R806.5 or 2009 IRC Section R806.4. 5.6 An ice barrier must be provided as required by Section 1507.2.8.2 of the IBC and Section R905.2.7 of the 2015 IRC and Section R905.2.7.1 of the 2012 and 2009 IRC. 5.7 Installation is limited to roofs having a slope of 2:12 (16.67% slope) or greater. 6.8 ZIP System® and ZIP System+Tm roof sheathing panels are manufactured by Huber Engineered Woods, LLC, in Crystal Hill, Virginia; Commerce, Georgia; Broken Bow, Oklahoma; and Easton, Maine, under a quality -control program with inspections by I CC -ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Wood Structural Panel Roof Sheathing Factory - laminated with an Alternative Roof Underlayment (AC266), dated May 2008 (editorially updated October 2015). 7.0 IDENTIFICATION Each ZIP System® and ZIP System+TM roof sheathing panel covered by this report must bear a label that includes the manufacturer's name (Huber Engineered Woods, LLC) and address; the product name; the evaluation report number (ESR-1473); and the grade, performance category and bond classification. The panel mill label and span rating, grade, performance category and bond classification label must be visible on the bottom face of panels, opposite the laminated facer. The ZIP System® tape roll is labeled with the product name and the evaluation report number (ESR-1473). i r'- IMES Evaluation Report ESR-1473 FBC Supplement Reissued September 2015 This report is subject to renewal September 2017. www.icc-es.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS, AND COMPOSITES Section: 0616 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+T"" ROOF SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System® and Zip System+Tm roof sheathing, recognized in ICC-ES master evaluation report ESR-1473, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code —Building ■ 2014 Florida Building Code —Residential 2.0 CONCLUSIONS The ZIP System® and ZIP System+Tm roof sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1473, complies with the 2014 Florida Building Code —Building and the 2014 Florida Building Code —Residential, provided the design and installation are in accordance with the International Building Code® provisions noted in the master report, and with the condition that wind uplifting design loads must be determined in accordance with Section 1609 of the Florida Building Code —Building and Section R301.2.1 of the Florida Building Code —Residential. Use of the ZIP System® and . ZIP System+TM roof sheathing for compliance with the High -Velocity Hurricane Zone provisions of the 2014 Florida Building Code —Building and the 2014 Florida Building Code —Residential has not been evaluated and is outside the scope of the evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued September 2015 and revised November 2015 ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed E.MMM as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as CZiV to any finding or other matter in this report, or as to any product covered by the report. awn Copyright O 2015 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 1 Florida Building Code Online Page 1 of 1 BCIS Home f Log In I User Registration 1 Hot Topics I Submit Surcharge I scats & Facts FI r'da Product Approval g USER: Public User er�y*Ks�� r Product Aooroval Menu > Product or Aoolicatlon Search > Application List Search Criteria r- r t...� �• t1eJAR NOtPPI-AdoV70BhA -OBnft 0IEISI0tJ1ICON7Ac108PR Refine Search Code Version 2014 FL# 17147 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Snw.r•M Rna..ira _ er.r,u..�rl.,..� F_# Tvoe Manufacturer Validated By Status FL17147- Revision Huber Engineered Woods LLC ICC Evaluation Service, Approved R Category: Structural Components LLC. History Subcategory: Products Introduced as a Result of New (205) 599-9800 Technology -PP-.. oy uorrt. nppravais oy uorn snag oe reviewea ano raunea oy me k UL ano/or ine commission I1 necessary. Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phohe: 850-487-1824 The State of Florida Is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: ® ® iclwck Credit Card Safe https://www.floridabuilding.org/pr/pr_app_lst.aspx 4/12/2017