HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CONEY RESIDENCE
Builder Name:
Street: TROWBRIDGE ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: MATTHEW AND ANGELA CONEY
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3141.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2641.00 ft2
b. Frame - Wood, Adjacent
R=13.0 500.00 f:2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (2814.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2814.00 ft2
6. Conditioned floor area above grade (ft2) 2814
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (375.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 200
a. U-Factor: Sgl, U=0.32 366.97 ft2
SHGC: SHGC=0.17
b. U-Factor: Sgl, U=0.31 4.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.17
a. Central Unit
47.0 SEER:16.00
c. U-Factor: Sgl, U=0.28 4.00 ft2
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: ` . 0.170
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2814.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2814.00 ft2
b. Conservation features
-
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.133 Total Proposed Modified Loads: 87.94
PASS
Total Baseline Loads: 96.91
I hereby certify that the plans and specifications covered by
Review of the plans and
15
ST,4?A
this calculation are in compliance with the Florida Energy
specifications covered by this
��'f'u
Code.
calculation indicates compliance
with the Florida Energy Code.
ti 1nnr."!�'�. ;;;-: .•;•°,� O
PREPAR D BY.:
Before construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
�K
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy C de.
COD,>WTi'1��
OWNER/AG NT•
BUILDING OFFICIAL:
DATE: c
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
12/19/2017 1:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 CENAWC.ArIV Page 1 of 6
FORM R405-2014
PROJECT
Title:
CONEY RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2814
Lot #
Owner:
MATTHEW AND ANGELA C
Total Stories:
1
Block/SubDivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
TROWBRIDGE
ROAD
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
Zone
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 2
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2814
32658
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
M WIC
100
800 No
0
1
Yes
Yes
Yes
2
M BATH
143
1144 No
0
1
Yes
Yes
Yes
3
MASTER BEDROO
317
4438 No
0
1
1
Yes
Yes
Yes
4
LAUNDRY
81
648 No
0
1
No
Yes
Yes
5
DINING
189
2646 No
0
1
Yes
Yes
Yes
6
KITCHEN
306
4284 Yes
0
1
No
Yes
Yes
7
PANTRY
25
350 No
0
1
Yes
Yes
Yes
8
BREAKFAST
87
1218 No
0
1
Yes
Yes
Yes
9
GREAT ROOM
525
7350 No
0
1
Yes
Yes
Yes
10
FOYER
66
924 No
0
1
Yes
Yes
Yes
11
DEN CLST
22
308 No
0
1
Yes
Yes
Yes
12
DEN
154
2156 No
0
1
Yes
Yes
Yes
13
BATH 3
88
704 No
0
1
Yes
Yes
Yes
14
BEDROOM 3
225
1800 No
0
1
1
Yes
Yes
Yes
15
CLST 3
30
240 No
0
1
Yes
Yes
Yes
16
BEDROOM 2
225
1800 No
0
1
1
Yes
Yes
Yes
17
CLST
12
96 No
0
1
No
Yes
Yes
18
WIC 2
55
440 No
0
1
No
Yes
Yes
19
BATH 2
126
1008 No
0
1
Yes
Yes
Yes
20
HALL
38
304 No
0
1
No
Yes
Yes
12/19/20171:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 6
FORM RAnli-qou
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
M WIC
21 ft
0
100 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
M BATH
lift
0
143 ft2
____
1
0
0
3 Slab -On -Grade Edge Insulation
MASTER BEDRO 36 ft
0
317 ft2
____
1
0
0
4Slab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
81 ft2
_-__
1
0
0
5 Slab -On -Grade Edge Insulation
DINING
17 ft
0
189 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
KITCHEN
1 ft
0
306 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation
PANTRY
5 ft
0
25 ft2
-_-_
1
0
0
8 Slab -On -Grade Edge Insulation
BREAKFAST
14.4 ft
0
87 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
GREAT ROOM
25 ft
0
525 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
FOYER
6 ft
0
66 ft2
__-_
1
0
0
1 lSlab-On-Grade Edge Insulation
DEN CLST
2 ft
0
22 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
DEN
14 ft
0
154 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
BATH 3
8 ft
0
88 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
BEDROOM 3
30 ft
0
225 ft2
1
0
0
15SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
30 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
BEDROOM 2
15 ft
0
225 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
CLST
1 ft
0
12 ft2
____
1
0
0
18SIab-On-Grade Edge Insulation
WIC 2
1 ft
0
55 ft2
____
1
0
0
19SIab-On-Grade Edge Insulation
BATH 2
34 ft
0
126 ft2
____
1
0
0
20SIab-On-Grade Edge Insulation
HALL
1 ft
0
38 ft2
__e
1
0
0
ROOF
v
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 3147 ft2
704 ft2
Light
0.6
No 0.9
No
20
26.6
ATTIC
/
V # Type
Ventilation
Vent
Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
2814 ft2
N N
12/19/2017 1:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) M WIC
20
Blown
100ft2
0.1
Wood
2
Under Attic (Unvented) M BATH
20
Blown
143 ft2
0.1
Wood
3
Under Attic (Unvented) MASTER BEDRO
20
Blown
317 ft2
0.1
Wood
4
Under Attic (Unvented) LAUNDRY
20
Blown
81ft2
0.1
Wood
5
Under Attic (Unvented) DINING
20
Blown
189 ft2
0.1
Wood
6
Under Attic (Unvented) KITCHEN
20
Blown
306 ft2
0.1
Wood
7
Under Attic (Unvented) PANTRY
20
Blown
25ft2
0.1
Wood
8
Under Attic (Unvented) BREAKFAST
20
Blown
87 ft2
0.1
Wood
9
Under Attic (Unvented) GREAT ROOM
20
Blown
525 ft2
0.1
Wood
10
Under Attic (Unvented) FOYER
20
Blown
66 ft2
0.1
Wood
11
Under Attic (Unvented) DEN CLST
20
Blown
22 ft2
0.1
Wood
12
Under Attic (U nvented) DEN
20
Blown
154ft2
0.1
Wood
13
Under Attic (Unvented) BATH 3
20
Blown
88 ft2
0.1
Wood
14
Under Attic (Unvented) BEDROOM 3
20
Blown
225 ft2
0.1
Wood
15
Under Attic (Unvented) CLST 3
20
Blown
30 ft2
0.1
Wood
16
Under Attic (Unvented) BEDROOM 2
20
Blown
225 ft2
0.1
Wood
17
Under Attic (Unvented) CLST
20
Blown
12 ft2
0.1
Wood
18
Under Attic (Unvented) WIC 2
20
Blown
55 ft2
0.1
Wood
19
Under Attic (Unvented) BATH
20
Blown
126ft2
0.1
Wood
20
Under Attic (Unvented) HALL
20
Blown
38 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
it
Qrnf
To IN nil lype Space
Area
AhSnrn
1
N
Exterior Concrete Block - Ext Insul M WIC
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
2
E
Exterior Concrete Block - Ext Insul M WIC
4.1
7
0 8
0
56.0 ft2
0
0
0.6
0
3
N
Exterior Concrete Block - Ext Insul M BATH
4.1
11
0 8
0
88.0 ft2
0
0
0.6
0
4
E
Exterior Concrete Block - Ext InsLKIASTER BE
4.1
20
0 14
0
280.0 ft2
0
0
0.6
0
5
S
Exterior Concrete Block - Ext InsLMASTER BE
4.1
16
0 14
0
224.0 ft2
0
0
0.6
0
6
E
Exterior Concrete Block - Ext Insul DINING
4.1
17
0 14
0
238.0 ft2
0
0
0.6
0
7
W
Exterior Concrete Block - Ext Insul PANTRY
4.1
5
0 14
0
70.0 ft2
0
0
0.6
0
8
SW
Exterior Concrete Block - Ext Insd3REAKFAST
4.1
4
3 14
0
59.5 ft2
0
0
0.6
0
9
W
Exterior Concrete Block - Ext InstBREAKFAST
4.1
6
.0 14
0
84.0 ft2
0
0
0.6
0
10
NW
Exterior Concrete Block - Ext InsL8REAKFAST
4.1
4
3 14
0
59.5 ft2
0
0
0.6
0
11
E
Exterior Concrete Block - Ext InstGREAT ROO
4.1
25
0 14
0
350.0 ft2
0
0
0.6
0
12
W
Exterior Concrete Block - Ext Insul FOYER
4.1
6
0 14
0
84.0 ft2
0
0
0.6
0
13
W
Exterior Concrete Block - Ext InsuIDEN CLST
4.1
2
0 14
0
28.0 ft2
0
0
0.6
0
14
W
Exterior Concrete Block - Ext Insul DEN
4.1
14
0 14
0
196.0 ft2
0
0
0.6
0
15
W
Exterior Concrete Block - Ext Insul BATH 3
4.1
8
0 8
0
64.0 ft2
0
0
0.6
0
16
S
Exterior Concrete Block - Ext InstSEDROOM 3
4.1
15
0 81,
0
120.0 ft2
0
0
0.6
0
17
W
Exterior Concrete Block - Ext InsffiEDROOM 3
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
18
S
Exterior Concrete Block - Ext Insul CLST 3
4.1
2
0 8
0
16.0 ft2
0
0
0.6
0
19
S
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
20
N
Exterior Concrete Block - Ext Insul BATH 2
4.1
7
0 8
0
56.0 ft2
0
0
0.6
0
12/19/2017 1:02 PM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
21 E
Exterior
Concrete Block - Ext Insul BATH 2
4.1 20 0
8 0
160.0 ft2
0
0 0.6
0
22 S
Exterior
Concrete Block - Ext Insul BATH 2
4.1 7 0
8 0
56.0 ft2
0
0 0.6
0
23 N
Garage
Frame - Wood
KITCHEN
13 23
10
230.0 ft2
0
0 0.600000 0
_24 N
Garage
Frame -Wood
KITCHEN
13 27
10
270.0ft2
0
0 0.600000 0
DOORS
#
Ornt
Door Type
Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated
FOYER
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
N
3
Vinyl
Low-E Single
Yes
0.31 0.17
4.0 ft2
2 ft 0 in
1 ft4 in
None
None
2
E
4
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
S
5
Vinyl
Low-E Single
Yes
0.32 0.17
60.3 ft2
2 ft 0 in
1 ft 4 in
None
None
4
E
6
Vinyl
Low-E Single
Yes
0.32 0.17
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
SW
8
Vinyl
Low-E Single
Yes
0.32 0.17
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
W
9
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
NW
10
Vinyl
Low-E Single
Yes
0.32 0.17
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
E
11
Vinyl
Low-E Single
Yes
0.32 0.17
40.2 ft2
2 ft 0 in
1 ft 4 in
None
None
9
E
11
Vinyl
Low-E Single
Yes
0.32 0.17
40.2 ft2
2 ft 0 in
1 ft 4 in
None
None
10
W
12
Vinyl
Low-E Single
Yes
0.32 0.17
13.4 ft2
2 ft 0 in
1 ft 4 in
None
None
11
W
14
Vinyl
Low-E Single
Yes
0.32 0.17
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
W
15
Vinyl
Low-E Single
Yes
0.28 0.21
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
S
16
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
14
W
17
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
15
S
19
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
16
N
20
Vinyl
Low-E Single
Yes
0.32 0.17
17.9 ft2
2 ft 0 in
1 ft 4 in
None
None
17
E
21
Vinyl
Low-E Single
Yes
0.32 0.17
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
621 ft2
384 ft2
50 ft
loft
13
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50)
.000516 3810.1 209.17 393.37
.3768
7
12/19/2017 1:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 6
FORM R4n5-2n14
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat
None
COP:1
34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
Split
SEER: 16
47 kBtu/hr
1410 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.98 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model # Area
Volume
FEF
None None
ft2
DUCTS
-- Supply --
— Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic 6 200 ft2
Attic
20 ft2 Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb Mar
Apr
Ma Jun Jul
Au
Se
Oct
Nov
Dec
HeatinHJan Feb Mar
f APr
f May 4 Jun f Jul
4 Au4
Sep
Oct
Nov
Dec
Ventin Jan Feb Mar
[X] Apr
[ May [ Jun [ Jul
[ Aug
[ Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (W D) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Cooling (W EH) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
12/19/2017 1:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CONEY RESIDENCE Builder Name:
Street: TROWBRIDGE ROAD PermitOfrice: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: MATTHEW AND ANGELA CONEY Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
12/19/2017 1:03 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
! . .
FORM R405-2014
ENERGY PERFORMANCE, LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
TROWBRIDGE ROAD, FORT PIERCE, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows-
Description
a. U-Factor:
Sgl, U=0.32
SHGC:
SHGC=0.17
b. U-Factor:
Sgl, U=0.31
SHGC:
SHGC=0.17
c. U-Factor:
Sgl, U=0.28
SHGC:
SHGC=0.21
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
Single-family
1
3
No
2814
Area
366.97 ft2
4.00 ft2
4.00 ft2
ft2
2.000 ft.
0.170
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2814.00 ft2
b. N/A R= ft2
c. N/A- R= ft2
9. Wall Types
a. Concrete Block - Ext Insul, Exterior
b. Frame- Wood, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Roof Deck (Unvented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featVres.
Builder Signature: I I -qv� Date:
Address of New Home: " 'Q6 w a1 Tp fs C 4J) City/FL Zip: 6, PZaef iG
Insulation Area
R=4.1 2641.00 ft2
R=13.0 500.00 ft2
R=
ft2
R=
ft2
Insulation
Area
R=20.0
2814.00 ft2
R=
ft2
R=
ft2
R ft2
6 200
kBtu/hr
Efficiency
47.0
SEER:16.00
kBtu/hr Efficiency
34.0 COP:1.00
Cap: 40 gallons
EF: 0.98
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building. Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/19/2017 1:03 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1