HomeMy WebLinkAboutREVISION 9-12-18OFFICE USE ONLY:
DATE FILED:
REVISION FEE:
LOCATION/SITE
ADDRESS:
880 Trowbridge Rd
PERMIT # 1712-0562
RECEIPT # IA7q
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-6662
(772) 462-1563
APPLICATION FOR BUILDING PERMIT REVISION
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
revise insulation on page 1 of 7 to reflect R-11 in garage frame walls, revise energy calculations to reflect R-11
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CRC 1330685
BUSINESS NAME: Trefelner Construction Inc
QUALIFIERS NAME: James Trefelner
ADDRESS: 1760 Copenhaver Rd
CITY: Ft. Pierce STATE: FI
PHONE (DAYTIME): 7722019833
OWNER/BUILDER INFORMATION:
NAME: Matt & Angela Coney
ADDRESS:8303 Fort Walton Ave
CITY: Ft. Pierce
PHONE (DAYTIME: 7723700391
STATE: FL
ARCHITECT/ENGINEER INFORMATION:
NAME: PAUL WELCH
ADDRESS: 1984 SW Biltmore St. Suite #114
CITY: PSL
PHONE (DAYTIME): 7727859888
STATE: FL
ST. LUCIE CO CERT. #: 28600
I
F
SLCCC: 9123109
Revised 06130/17 File
FAX:
ZIP: 34945
ZIP: 34984
RECE11" t w v 0",
SEP 12 2018
Permitting Departr',3ent
St. Lucie County, FL
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CONEY RESIDENCE
Builder Name:
Street: 880 TROW BRIDGE ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: MATTHEW AND ANGELA CONEY
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3141.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2641.00 ft2
b. Frame - Wood, Adjacent
R=11.0 500.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (2814.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2814.00 ft2
6. Conditioned floor area above grade (ft2) 2814
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(375.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 200
a. U-Factor: Sgl, U=0.32 366.97 ft2
SHGC: SHGC=0.17
b. U-Factor: Sgl, U=0.31 4.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.17
a. Central Unit
47.0 SEER:16.00
c. U-Factor: Sgl, U=0.28 4.00 ft2
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.170
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2814.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2814.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.133 Total Proposed Modified Loads: 88.28
PASS
Total Baseline Loads: 96.93
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
D�Z1riE,ST,�r�
Code.
calculation indicates compliance�.��`
with the Florida Energy Code.
t�'.'.•��`���� �O
PREP D Y:
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
�. 4�� X.
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Cod
Florida Statutes.
SAS
CAD wt
f
OWNER/AGENT-`' l
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air har
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance
ALL PROJECTS require an envelope leakage test report with envelope leakage no great
-vile rC®viv
8/15/2018 2:12 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title:
CONEY RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2814
Lot #
Owner Name:
MATTHEW AND ANGELA
C
Total Stories:
1
Block/SubDivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
880 TROW BRIDGE
RO
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2814
32658
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
M WIC
100
800 No
0
1
Yes
Yes
Yes
2
M BATH
143
1144 No
0
1
Yes
Yes
Yes
3
MASTER BEDROO
317
4438 No
0
1
1
Yes
Yes
Yes
4
LAUNDRY
81
648 No
0
1
No
Yes
Yes
5
DINING
189
2646 No
0
1
Yes
Yes
Yes
6
KITCHEN
306
4284 Yes
0
1
No
Yes
Yes
7
PANTRY
25
350 No
0
1
Yes
Yes
Yes
8
BREAKFAST
87
1218 No
0
1
Yes
Yes
Yes
9
GREAT ROOM
525
7350 No
0
1
Yes
Yes
Yes
10
FOYER
66
924 No
0
1
Yes
Yes
Yes
11
DEN CLST
22
308 No
0
1
Yes
Yes
Yes
12
DEN
154
2156 No
0
1
Yes
Yes
Yes
13
BATH 3
88
704 No
0
1
Yes
Yes
Yes
14
BEDROOM 3
225
1800 No
0
1
1
Yes
Yes
Yes
15
CLST 3
30
240 No
0
1
Yes
Yes
Yes
16
BEDROOM 2
225
1800 No
0
1
1
Yes
Yes
Yes
17
CLST
12
96 No
0
1
No
Yes
Yes
18
WIC 2
55
440 No
0
1
No
Yes
Yes
19
BATH 2
126
1008 No
0
1
Yes
Yes
Yes
20
HALL
38
304 No
0
1
No
Yes
Yes
8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
M W IC
21 ft
0
100 ft2
----
1
0
0
2 Slab -On -Grade Edge Insulation
M BATH
lift
0
143 ft2
____
1
0
0
3 Slab -On -Grade Edge Insulation
MASTER BEDRO
36 ft
0
317 ft2
----
1
0
0
4Slab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
81 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulation
DINING
17 ft
0
189 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulation
KITCHEN
1 ft
0
306 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulation
PANTRY
5 ft
0
25 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation
BREAKFAST
14.4 ft
0
87 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulation
GREAT ROOM
25 ft
0
525 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation
FOYER
6 ft
0
66 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
DEN CLST
2 ft
0
22 ft2
----
1
0
0
12SIab-On-Grade Edge Insulation
DEN
14 ft
0
154 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
BATH 3
8 ft
0
88 ft2
----
1
0
0
14SIab-On-Grade Edge Insulation
BEDROOM 3
30 ft
0
225 ft2
----
1
0
0
15SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
30 ft2
----
1
0
0
16SIab-On-Grade Edge Insulation
BEDROOM 2
15 ft
0
225 ft2
___-
1
0
0
17SIab-On-Grade Edge Insulation
CLST
1 ft
0
12 ft2
----
1
0
0
18SIab-On-Grade Edge Insulation
WIC 2
1 ft
0
55 ft2
----
1
0
0
19SIab-On-Grade Edge Insulation
BATH 2
34 ft
0
126 ft2
----
1
0
0
20SIab-On-Grade Edge Insulation
HALL
1 ft
0
38 ft2
----
1
0
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
v # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 3147 ft2
704 ft2
Light
0.6
No 0.9
No
20
26.6
ATTIC
/
V # Type
Ventilation
Vent
Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
2814 ft2
N N
8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) M WIC
20
Blown
100 ft2
0.1
Wood
2
Under Attic (Unvented) M BATH
20
Blown
143 ft2
0.1
Wood
3
Under Attic (Unvented) MASTER BEDRO
20
Blown
317 ft2
0.1
Wood
4
Under Attic (Unvented) LAUNDRY
20
Blown
81 ft2
0.1
Wood
5
Under Attic (Unvented) DINING
20
Blown
189 ft2
0.1
Wood
6
Under Attic (Unvented) KITCHEN
20
Blown
306 ft2
0.1
Wood
7
Under Attic (Unvented) PANTRY
20
Blown
25 ft2
0.1
Wood
8
Under Attic (Unvented) BREAKFAST
20
Blown
87ft2
0.1
Wood
9
Under Attic (Unvented) GREAT ROOM
20
Blown
525 ft2
0.1
Wood
10
Under Attic (Unvented) FOYER
20
Blown
66 ft2
0.1
Wood
11
Under Attic (Unvented) DEN CLST
20
Blown
22 ft2
0.1
Wood
12
Under Attic (Unvented) DEN
20
Blown
154 ft2
0.1
Wood
13
Under Attic (Unvented) BATH 3
20
Blown
88 ft2
0.1
Wood
14
Under Attic (Unvented) BEDROOM 3
20
Blown
225 ft2
0.1
Wood
15
Under Attic (Unvented) CLST 3
20
Blown
30 ft2
0.1
Wood
16
Under Attic (Unvented) BEDROOM 2
20
Blown
225 ft2
0.1
Wood
17
Under Attic (Unvented) CLST
20
Blown
12 ft2
0.1
Wood
18
Under Attic (Unvented) WIC 2
20
Blown
55 ft2
0.1
Wood
19
Under Attic (Unvented) BATH 2
20
Blown
126 ft2
0.1
Wood
20
Under Attic (Unvented) HALL
20
Blown
38 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
Space
Et
rea
qor1
N
Exterior Concrete Block - Ext Insul M WIC
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
2
E
Exterior Concrete Block - Ext Insul M W IC
4.1
7
0 8
0
56.0 ft2
0
0
0.6
0
3
N
Exterior Concrete Block - Ext Insul M BATH
4.1
11
0 8
0
88.0 ft2
0
0
0.6
0
4
E
Exterior Concrete Block - Ext InsLKIASTER BE
4.1
20
0 14
0
280.0 ft2
0
0
0.6
0
5
S
Exterior Concrete Block - Ext InstwIASTER BE
4.1
16
0 14
0
224.0 ft2
0
0
0.6
0
6
E
Exterior Concrete Block- Ext Insul DINING
4.1
17
0 14
0
238.0 ft2
0
0
0.6
0
7
W
Exterior Concrete Block - Ext Insul PANTRY
4.1
5
0 14
0
70.0 ft2
0
0
0.6
0
8
SW
Exterior Concrete Block - Ext Insi9REAKFAST
4.1
4
3 14
0
59.5 ft2
0
0
0.6
0
9
W
Exterior Concrete Block - Ext InstBREAKFAST
4.1
6
0 14
0
84.0 ft2
0
0
0.6
0
10
NW
Exterior Concrete Block - Ext Insi9REAKFAST
4.1
4
3 14
0
59.5 ft2
0
0
0.6
0
11
E
Exterior Concrete Block - Ext InstOREAT ROO
4.1
25
0 14
0
350.0 ft2
0
0
0.6
0
12
W
Exterior Concrete Block - Ext Insul FOYER
4.1
6
0 14
0
84.0 ft2
0
0
0.6
0
13
W
Exterior Concrete Block - Ext InsulDEN CLST
4.1
2
0 14
0
28.0 ft2
0
0
0.6
0
14
W
Exterior Concrete Block - Ext Insul DEN
4.1
14
0 14
0
196.0 ft2
0
0
0.6
0
15
W
Exterior Concrete Block - Ext Insul BATH 3 •
4.1
8
0 8
0
64.0 ft2
0
0
0.6
0
16
S
Exterior Concrete Block - Ext InstSEDROOM 3
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
17
W
Exterior Concrete Block - Ext InsZEDROOM 3
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
18
S
Exterior Concrete Block - Ext Insul CLST 3
4.1
2
0 8
0
16.0 ft2
0
0
0.6
0
19
S
Exterior Concrete Block - Ext Inst9EDROOM 2
4.1
15
0 8
0
120.0 ft2
0
0
0.6
0
20
N
Exterior Concrete Block - Ext Insul BATH 2
4.1
7
0 8
0
56.0 ft2
0
0
0.6
0
8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
21 E
Exterior
Concrete Block - Ext Insul BATH 2
4.1 20 0
8 0
160.0 ft2
0
0 0.6
0
22 S
Exterior
Concrete Block - Ext Insul BATH 2
4.1 7 0
8 0
56.0 ft2
0
0 0.6
0
23 N
Garage
Frame - Wood
KITCHEN
11 23
10
230.0 ft2
0
0.25 0.600000 0
24 N
Garage
Frame - Wood
KITCHEN
11 27
10
270.0 ft2
0
0.25 0.600000 0
DOORS
#
Ornt
Door Type
Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated
FOYER
None .39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
N
3
Vinyl
Low-E Single
Yes
0.31 0.17
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
E
4
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
S
5
Vinyl
Low-E Single
Yes
0.32 0.17
60.3 ft2
2 ft 0 in
1 ft 4 in
None
None
4
E
6
Vinyl
Low-E Single
Yes
0.32 0.17
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
SW
8
Vinyl
Low-E Single
Yes
0.32 0.17
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
W
9
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
NW
10
Vinyl
Low-E Single
Yes
0.32 0.17
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
E
11
Vinyl
Low-E Single
Yes
0.32 0.17
40.2 ft2
2 ft 0 in
1 ft 4 in
None
None
9
E
11
Vinyl
Low-E Single
Yes
0.32 0.17
40.2 ft2
2 ft 0 in
1 ft 4 in
None
None
10
W
12
Vinyl
Low-E Single
Yes
0.32 0.17
13.4 ft2
2 ft 0 in
1 ft 4 in
None
None
11
W
14
Vinyl
Low-E Single
Yes
0.32 0.17
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
W
15
Vinyl
Low-E Single
Yes
0.28 0.21
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
S
16
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
14
W
17
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
15
S
19
Vinyl
Low-E Single
Yes
0.32 0.17
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
16
N
20
Vinyl
Low-E Single
Yes
0.32 0.17
17.9 ft2
2 ft 0 in
1 ft 4 in
None
None
17
E
21
Vinyl
Low-E Single
Yes
0.32 0.17
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
621 ft2
621 ft2
50 ft
loft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
ProposedACH(50)
.000516 3810.1 209.17
393.37
.4182
7
8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2014
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COPA
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
Split
SEER: 16
47 kBtu/hr
1410 cfm
0.8
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.98 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector
Model # Area
Volume
FEF
None None
ft2
DUCTS
V
— Supply —
— Return --
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 200 ft2
Attic
20 ft2 Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan
HeatinHJan
Feb
H Feb
Mar
Mar
Apr
f Apr
May Jun Jul
f May Jun Jul
Auge
AuSep
f
Oct
Oct
Nov
Nov
Dec
f X� Dec
VentingJan
Feb
Mar
[X] Apr
[ May Jun Jul
Aug
Se
[X]
Oct
Nov
[ ]Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD)
AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CONEY RESIDENCE Builder Name:
Street: 880 TROWBRIDGE ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: MATTHEW AND ANGELA CONEY Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
880 TROWBRIDGE ROAD, FORT PIERCE, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
2641.00 ft2
b. Frame - Wood, Adjacent
R=11.0
500.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0
2814.00 ft2
6. Conditioned floor area (ft2)
2814
b. N/A
R=
ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Sgl, U=0.32
366.97 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 200
SHGC: SHGC=0.17
b. U-Factor: Sgl, U=0.31
4.00 ft2
SHGC: SHGC=0.17
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Sgl, U=0.28
4.00 ft2
a. Central Unit
47.0
SEER:16.00
SHGC: SHGC=0.21
d. U-Factor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
34.0 COP:1.00
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.170
8. Floor Types
Insulation
Area
14. Hot water systems
a. Slab -On -Grade Edge Insulation
R=0.0
2814.00 ft2
a. Electric
Cap: 40 gallons
EF: 0.98
b. N/A
R=
ft2
c. N/A
R=
ft2
b. Conservation features
None
15. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featu es.
Builder Signature: Date:
Address of New Hom a� %IUW Q2Zp(,.� h® City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1