Loading...
HomeMy WebLinkAboutREVISION 9-12-18OFFICE USE ONLY: DATE FILED: REVISION FEE: LOCATION/SITE ADDRESS: 880 Trowbridge Rd PERMIT # 1712-0562 RECEIPT # IA7q PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-6662 (772) 462-1563 APPLICATION FOR BUILDING PERMIT REVISION PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: revise insulation on page 1 of 7 to reflect R-11 in garage frame walls, revise energy calculations to reflect R-11 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC 1330685 BUSINESS NAME: Trefelner Construction Inc QUALIFIERS NAME: James Trefelner ADDRESS: 1760 Copenhaver Rd CITY: Ft. Pierce STATE: FI PHONE (DAYTIME): 7722019833 OWNER/BUILDER INFORMATION: NAME: Matt & Angela Coney ADDRESS:8303 Fort Walton Ave CITY: Ft. Pierce PHONE (DAYTIME: 7723700391 STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: PAUL WELCH ADDRESS: 1984 SW Biltmore St. Suite #114 CITY: PSL PHONE (DAYTIME): 7727859888 STATE: FL ST. LUCIE CO CERT. #: 28600 I F SLCCC: 9123109 Revised 06130/17 File FAX: ZIP: 34945 ZIP: 34984 RECE11" t w v 0", SEP 12 2018 Permitting Departr',3ent St. Lucie County, FL FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CONEY RESIDENCE Builder Name: Street: 880 TROW BRIDGE ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: MATTHEW AND ANGELA CONEY Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3141.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2641.00 ft2 b. Frame - Wood, Adjacent R=11.0 500.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2814.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2814.00 ft2 6. Conditioned floor area above grade (ft2) 2814 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(375.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 200 a. U-Factor: Sgl, U=0.32 366.97 ft2 SHGC: SHGC=0.17 b. U-Factor: Sgl, U=0.31 4.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.17 a. Central Unit 47.0 SEER:16.00 c. U-Factor: Sgl, U=0.28 4.00 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.170 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2814.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2814.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.133 Total Proposed Modified Loads: 88.28 PASS Total Baseline Loads: 96.93 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this D�Z1riE,ST,�r� Code. calculation indicates compliance�.��` with the Florida Energy Code. t�'.'.•��`���� �O PREP D Y: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 �. 4�� X. I hereby certify that this building, as designed, is in compliance with the Florida Energy Cod Florida Statutes. SAS CAD wt f OWNER/AGENT-`' l BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air har certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance ALL PROJECTS require an envelope leakage test report with envelope leakage no great -vile rC®viv 8/15/2018 2:12 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: CONEY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2814 Lot # Owner Name: MATTHEW AND ANGELA C Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 880 TROW BRIDGE RO Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2814 32658 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M WIC 100 800 No 0 1 Yes Yes Yes 2 M BATH 143 1144 No 0 1 Yes Yes Yes 3 MASTER BEDROO 317 4438 No 0 1 1 Yes Yes Yes 4 LAUNDRY 81 648 No 0 1 No Yes Yes 5 DINING 189 2646 No 0 1 Yes Yes Yes 6 KITCHEN 306 4284 Yes 0 1 No Yes Yes 7 PANTRY 25 350 No 0 1 Yes Yes Yes 8 BREAKFAST 87 1218 No 0 1 Yes Yes Yes 9 GREAT ROOM 525 7350 No 0 1 Yes Yes Yes 10 FOYER 66 924 No 0 1 Yes Yes Yes 11 DEN CLST 22 308 No 0 1 Yes Yes Yes 12 DEN 154 2156 No 0 1 Yes Yes Yes 13 BATH 3 88 704 No 0 1 Yes Yes Yes 14 BEDROOM 3 225 1800 No 0 1 1 Yes Yes Yes 15 CLST 3 30 240 No 0 1 Yes Yes Yes 16 BEDROOM 2 225 1800 No 0 1 1 Yes Yes Yes 17 CLST 12 96 No 0 1 No Yes Yes 18 WIC 2 55 440 No 0 1 No Yes Yes 19 BATH 2 126 1008 No 0 1 Yes Yes Yes 20 HALL 38 304 No 0 1 No Yes Yes 8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M W IC 21 ft 0 100 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation M BATH lift 0 143 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation MASTER BEDRO 36 ft 0 317 ft2 ---- 1 0 0 4Slab-On-Grade Edge Insulation LAUNDRY 1 ft 0 81 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation DINING 17 ft 0 189 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 306 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation PANTRY 5 ft 0 25 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation BREAKFAST 14.4 ft 0 87 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation GREAT ROOM 25 ft 0 525 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation FOYER 6 ft 0 66 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation DEN CLST 2 ft 0 22 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation DEN 14 ft 0 154 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation BATH 3 8 ft 0 88 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 3 30 ft 0 225 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation CLST 3 2 ft 0 30 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation BEDROOM 2 15 ft 0 225 ft2 ___- 1 0 0 17SIab-On-Grade Edge Insulation CLST 1 ft 0 12 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation WIC 2 1 ft 0 55 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation BATH 2 34 ft 0 126 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulation HALL 1 ft 0 38 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 3147 ft2 704 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2814 ft2 N N 8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) M WIC 20 Blown 100 ft2 0.1 Wood 2 Under Attic (Unvented) M BATH 20 Blown 143 ft2 0.1 Wood 3 Under Attic (Unvented) MASTER BEDRO 20 Blown 317 ft2 0.1 Wood 4 Under Attic (Unvented) LAUNDRY 20 Blown 81 ft2 0.1 Wood 5 Under Attic (Unvented) DINING 20 Blown 189 ft2 0.1 Wood 6 Under Attic (Unvented) KITCHEN 20 Blown 306 ft2 0.1 Wood 7 Under Attic (Unvented) PANTRY 20 Blown 25 ft2 0.1 Wood 8 Under Attic (Unvented) BREAKFAST 20 Blown 87ft2 0.1 Wood 9 Under Attic (Unvented) GREAT ROOM 20 Blown 525 ft2 0.1 Wood 10 Under Attic (Unvented) FOYER 20 Blown 66 ft2 0.1 Wood 11 Under Attic (Unvented) DEN CLST 20 Blown 22 ft2 0.1 Wood 12 Under Attic (Unvented) DEN 20 Blown 154 ft2 0.1 Wood 13 Under Attic (Unvented) BATH 3 20 Blown 88 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 3 20 Blown 225 ft2 0.1 Wood 15 Under Attic (Unvented) CLST 3 20 Blown 30 ft2 0.1 Wood 16 Under Attic (Unvented) BEDROOM 2 20 Blown 225 ft2 0.1 Wood 17 Under Attic (Unvented) CLST 20 Blown 12 ft2 0.1 Wood 18 Under Attic (Unvented) WIC 2 20 Blown 55 ft2 0.1 Wood 19 Under Attic (Unvented) BATH 2 20 Blown 126 ft2 0.1 Wood 20 Under Attic (Unvented) HALL 20 Blown 38 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Et rea qor1 N Exterior Concrete Block - Ext Insul M WIC 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext Insul M W IC 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Ext Insul M BATH 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Ext InsLKIASTER BE 4.1 20 0 14 0 280.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Ext InstwIASTER BE 4.1 16 0 14 0 224.0 ft2 0 0 0.6 0 6 E Exterior Concrete Block- Ext Insul DINING 4.1 17 0 14 0 238.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Ext Insul PANTRY 4.1 5 0 14 0 70.0 ft2 0 0 0.6 0 8 SW Exterior Concrete Block - Ext Insi9REAKFAST 4.1 4 3 14 0 59.5 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Ext InstBREAKFAST 4.1 6 0 14 0 84.0 ft2 0 0 0.6 0 10 NW Exterior Concrete Block - Ext Insi9REAKFAST 4.1 4 3 14 0 59.5 ft2 0 0 0.6 0 11 E Exterior Concrete Block - Ext InstOREAT ROO 4.1 25 0 14 0 350.0 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 14 0 84.0 ft2 0 0 0.6 0 13 W Exterior Concrete Block - Ext InsulDEN CLST 4.1 2 0 14 0 28.0 ft2 0 0 0.6 0 14 W Exterior Concrete Block - Ext Insul DEN 4.1 14 0 14 0 196.0 ft2 0 0 0.6 0 15 W Exterior Concrete Block - Ext Insul BATH 3 • 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 16 S Exterior Concrete Block - Ext InstSEDROOM 3 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 17 W Exterior Concrete Block - Ext InsZEDROOM 3 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 18 S Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Ext Inst9EDROOM 2 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 20 N Exterior Concrete Block - Ext Insul BATH 2 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 21 E Exterior Concrete Block - Ext Insul BATH 2 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 22 S Exterior Concrete Block - Ext Insul BATH 2 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 23 N Garage Frame - Wood KITCHEN 11 23 10 230.0 ft2 0 0.25 0.600000 0 24 N Garage Frame - Wood KITCHEN 11 27 10 270.0 ft2 0 0.25 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 3 Vinyl Low-E Single Yes 0.31 0.17 4.0 ft2 2 ft 0 in 1 ft 4 in None None 2 E 4 Vinyl Low-E Single Yes 0.32 0.17 20.0 ft2 2 ft 0 in 1 ft 4 in None None 3 S 5 Vinyl Low-E Single Yes 0.32 0.17 60.3 ft2 2 ft 0 in 1 ft 4 in None None 4 E 6 Vinyl Low-E Single Yes 0.32 0.17 30.0 ft2 2 ft 0 in 1 ft 4 in None None 5 SW 8 Vinyl Low-E Single Yes 0.32 0.17 10.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 9 Vinyl Low-E Single Yes 0.32 0.17 20.0 ft2 2 ft 0 in 1 ft 4 in None None 7 NW 10 Vinyl Low-E Single Yes 0.32 0.17 10.0 ft2 2 ft 0 in 1 ft 4 in None None 8 E 11 Vinyl Low-E Single Yes 0.32 0.17 40.2 ft2 2 ft 0 in 1 ft 4 in None None 9 E 11 Vinyl Low-E Single Yes 0.32 0.17 40.2 ft2 2 ft 0 in 1 ft 4 in None None 10 W 12 Vinyl Low-E Single Yes 0.32 0.17 13.4 ft2 2 ft 0 in 1 ft 4 in None None 11 W 14 Vinyl Low-E Single Yes 0.32 0.17 30.0 ft2 2 ft 0 in 1 ft 4 in None None 12 W 15 Vinyl Low-E Single Yes 0.28 0.21 4.0 ft2 2 ft 0 in 1 ft 4 in None None 13 S 16 Vinyl Low-E Single Yes 0.32 0.17 20.0 ft2 2 ft 0 in 1 ft 4 in None None 14 W 17 Vinyl Low-E Single Yes 0.32 0.17 20.0 ft2 2 ft 0 in 1 ft 4 in None None 15 S 19 Vinyl Low-E Single Yes 0.32 0.17 20.0 ft2 2 ft 0 in 1 ft 4 in None None 16 N 20 Vinyl Low-E Single Yes 0.32 0.17 17.9 ft2 2 ft 0 in 1 ft 4 in None None 17 E 21 Vinyl Low-E Single Yes 0.32 0.17 15.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 621 ft2 621 ft2 50 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000516 3810.1 209.17 393.37 .4182 7 8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 47 kBtu/hr 1410 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V — Supply — — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinHJan Feb H Feb Mar Mar Apr f Apr May Jun Jul f May Jun Jul Auge AuSep f Oct Oct Nov Nov Dec f X� Dec VentingJan Feb Mar [X] Apr [ May Jun Jul Aug Se [X] Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CONEY RESIDENCE Builder Name: Street: 880 TROWBRIDGE ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: MATTHEW AND ANGELA CONEY Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index, the more efficient the home. 880 TROWBRIDGE ROAD, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2641.00 ft2 b. Frame - Wood, Adjacent R=11.0 500.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2814.00 ft2 6. Conditioned floor area (ft2) 2814 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.32 366.97 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 200 SHGC: SHGC=0.17 b. U-Factor: Sgl, U=0.31 4.00 ft2 SHGC: SHGC=0.17 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.28 4.00 ft2 a. Central Unit 47.0 SEER:16.00 SHGC: SHGC=0.21 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.170 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 2814.00 ft2 a. Electric Cap: 40 gallons EF: 0.98 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featu es. Builder Signature: Date: Address of New Hom a� %IUW Q2Zp(,.� h® City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/15/2018 2:12 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1