1. APPLICABLE CODE: 2014 FLORIDA BUILDING CODE (5TH EDITION) & ASCE-/-IU MINIMUM
DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES.
2. BOLT DIAMETER AND, EMBEDMENT�IENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE
(5TH EDITION)'REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE
(SYP)F,ESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL.
3, AtL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS,
CONSIDERING FROM A 70 TO A MAXIMUM 27 ° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE.
BUILDING NOT TO EXCEED 30'-0" ROOF HEIGHT. CONTRACTOR RESPONSIBLE TO VERIFY ROOF SLOPE.
4.EACH BRACKET SHALL BE FASTENED TO THE COLLECTOR WITH (1) ST STEEL CARRIAGE BOLT PER
CONNECTION. EACH BRACKET SHALL BE FASTENED TO ROOF:TRUSS WITH (1) 8" DIA. A276 STAINLESS STEEL
LAG BOLT. SEE SCHEDULE FOR LAG -BOLT DESIGN EMBEDMENT.
5. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY
OF THE CONTRACTOR TO PILOT FILL ALL HOLES.
6. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO SOLENE INSTALLATION
MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SOLAR SPECS.
7. ALL LAG BOLTS THIS SHEET SHALL BE A276 STAINLESS STEEL UNLESS OTHERWISE SPECIFIED.
8. SOLENE COLLECTOR(S) THIS SHEET SHALL BE ALL SOLENE AURORA AND SLSG (SPLIT GLASS) COLLECTORS.
9. PVC PIPE RISER/SPACER IS REQUIRED FOR PIPE CLAMPS WHERE PIPE ELEVATION VARIES.
10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014
Gi nome R1 m DTmr rnnF (STH EDITION) OR LOCAL GOVERNING CODE.
ULTIMATE
Vie WIND
Vd WIND
Vd WIND
QUANTITY OF
EMBED.
COLLECTOR
WIND SPEED
PRESSURES
PRESSURES
PRESSURES
BOLTS - BRACKETS
DEPTH
LAYOUT
V., (MPH)
ZONE 1(PSF)
ZONE 2 (PSF)
ZONE 3* (PSF)
PER COLLECTOR
REQ.
110-140
17.5 , -27.9
17.5 , -48.6
17.5 , -71.8*
(4) g° DIA. - (4) BRCK.
2" **
PORT., LAND.
141-175
26.8 , -42.7
26.8 , -74.3
26.8 , -109.9
(4) 8" DIA. - (4) BRCK.
3- **
PORT., LAND.
s-, PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES,
RESPECTIVELY.
--SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND SPEED PRESSURES
WITH EXPOSURE "C", RISK CATEGORY II,. ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10
"MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2014 F.R.C.
- MINIMUM Vm WIND PRESSURE SHALL BE 16.0 PSF AND -16.0 PSF PER ASCE 7-10 SECTION 30.2.2.
- EFFECTIVE DESIGN WIND AREA IS 10 SF PER COLLECTOR.
** LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDING ANY ROOF DECKING.
* INSTALLATION OF COLLECTORS MUST BE IN WIND ZONE 1 AND 2. WIND ZONE 3 INSTALLATION
REQUIRES SITE SPECIFIC STRUCTURAL ENGINEER'S APPROVAL.
TYPICAL COLLECTOR PITCHED ROOF LAYOUT
- WIND ZONES - SCHEDULE - PLAN 1
SCALE: NONE SL-3
NOTE: FOR TILE ROOFS, SOLENE MOUNTING BRACKET WITH LIFT KIT ASSEMBLY SHALL BE USED. ROOF DECKING
NOT SHOWN FOR CLARITY. REFER TO SCHEDULE FOR REQUIRED COLLECTOR LAYOUT FOR EACH WIND SPEED.
SOLENE ALUM. MOUNTING BRCK. TYP
4 PLCS. SEE SCHEDULE THIS SHEET
2'-T O.C. TYP.
I
I
I
IL
I�
IN
I�
Iv
Iv
MILL
L;�m,Lu
DILL
dl- 6-
PORTRAIT ORIENTATION
TYPICAL COLLECTOR ORIENTATIONS
SCALE: Q'=1'-0"
ROOF SHINGLES TYP.
SOLENE ALUMINUM MOUNTING
BRACKET.
SOLENE —
COLLECTOR
TYP.
#2 S.Y.P. WOOD
ROOF TRUSS
BEYOND
a" DIA. ST STL LAG BOLT TYP. SEE SCH FOR
EMBED DEPTH REQ TYP.
WOOD SHEATHING TYP.
REFER TO SCHEDULE THIS SHEET FOR REQUIRED
EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL
TYPICAL ASPHAL�METAL
SHINGLE CONNECC II ION DETAIL 3
SCALE: 1 1"=V-0" SL-3
SOLENE ALUM. MOUNT]
2'-0" O.C. TYP.k BRCK. TYP 4 PLCS. SEE
I SCHEDULE THIS SHEET
I�
I�
c
Ice
�I�
ZIP
oILL
DILL
LU�-
'
Lu' 0
LANDSCAPE ORIENTATION
ROOF SHINGLES TYP.
SOLENE ALUMINUM MOUNTING
BRACKET.
SOLENE
i
SOLENE ALUMINUM
FRAME SECTION TYP.
i6' STAINLESS STEELon
CARRIAGE BOLT
TYP. PER MOUNT
BRACKET
SOLENE ALUMINUM -
FLUSH MOUNT BRACKET SLOTTED HOLE
TYP. IN FRAME TYP.
TYPICAL CARRIAGE BOLT - FLUSH
MOUNT BRACKET CONNECTION DETAIL
SCALE: 1 Z'=1'-0"
REFER TO SCHEDULE THIS SHEET FOR REQUIRED_ EMBEDMENT DEPTH
LABELED "X" IN THIS DETAIL
CUT OUT OR REMOVE TILE TO INSTALL "LIFT KIT" ASSEMBLY. RE -INSTALL,
RE -FILL AND RE -SEAL TILES AFFECTED WITH APPROVED ROOF MAT.
SOLENE COLLECTOR TYP. °
SOLENE ALUMINUM MOUNTING -�\� °O °
BRACKET.
DIA. ST STL LAG BOLT TYP. o� °
SEE SCH FOR EMBED DEPTH
LUCIE U.J
-'+DING DIbS 1fi3X3Xe - 4" A
,REVI'lim T6 W/ 1" DIA, X
N C6MP
REV JI 3Y 'LIFT KIT'
DATL a
W! �sNS AN � . MIT
w o 19, KgPT O' 'd JOB OR
G'�1 QN'VWILL BE is, kDI_
0
FLAT OR
BARREL
-- WOOD TILE TYP
SHEATHING TYP.
#2 S.Y.P. WOOD ROOF
TRUSS TYP.
a P CAL FLAT TILE - BARREL
TILE ROOF CONNECTION DETAIL r6
SCALE: 1 Z'=V-0" SL-3
SOLENE ALUMINUM -
MOUNTING BRACKET.
42 S.Y.P. WOOD
ROOF TRUSS TYP.
2X PT S.Y.P. WOOD OR
ALUMINUM UNISTRUT
TYP CONT. ALONG PANEL
a" DIA. ST STL ALL-THRD ROD WITH NUT -
WASHERS MAX. 3'-0" O.C.-LOCTITE ALL NUTS
TYP. ALL CONNECTIONS
TYPICAL LIMITED SPACE OPTION
CONNECTION DETAIL
SCALE:
4
SL-3
ROOF SHINGLES TYP.
WOOD SHEATHING TYP.—
SOLENE COLLECTOR
TYP. �o
#2 S.Y.P. WOOD ROOF
- TRUSS BEYOND
�f S.Y.P. (2) 2X4 LOCATE BETWEEN
TRUSSES WITH 4-16D NAIL PATTERN
AT EACH END TO WOOD TRUSS TYP.
8' DIA. ST STL LAG BOLT TYP. SEE SCH FOR N�\�
EMBED DEPTH REQ TYP. `NN�\I
REFER TO SCHEDULE THIS SHEET FOR REQUIRED
EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL ,
TYPICAL WOOD SPANNER OPTION
FOR UNALIGNED TRUSS - BRACKET --��
CONNECTION DETAIL / �r "�,;;�
SCALE: 1;"=V-0"
OCT 2 7 20
m .
0
d' 1M
PROJECT:
Lu
z�Ln
LU
z
p � O
w ¢
U _ O
Lu U
��= z
O a p
cn
w ¢
O cn w
o
o�-- LL. n
w p 1 Lu
0
O I— p
o�� ¢c�
p
z Lu =o�
LLJ U p
O z af ne
cna¢aa
DATE 1-28-16
DRAWN BY: ]AT
CHKD BY: ]AT
REC. NO. # 1 29127
SCALE I AS NOTED
ss�
DRAWING # ENE
N
MENT NO
F F FKPP tflv9r
'