Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE" F ' J c7 - � Planning &Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 46 Certification for Design Load Compliance Project Name: STANDARD PACIFIC HOMES - RIVERBEND. Project Address: 3504 NW RADCLIFFE WAY - LOT 15 16 JpJ% Departmen 1 1PerM1tt1n9 county Permit #: 171 _ t✓ SCo 7 Occupancy Type: R-3 Construction Type: y. INSTRUCTIONS FOR USE: - 1 • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS OSED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3.. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph X ASD LRFD End Zone Width: 61-60 ft 5. Mean Roof Height 251-0° ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -46 Zone 2: -80 Zone 3: -118 Zone 4: -52 Zone 5: -62 Garage: -52 7. Design Loads: Floor: 40/25 PSF Roof/Dead: 15/10 PSF Roof/Live: 20/10 Balcony: 6N30 PSF Dock: N/A PSF Deck: N/A PSF Stairs: 40 PSF Fence: N/A PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes s DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie \C�f 6 ! � i als/o,0, tify that structural elements depicted on these plans provide adequate resistance to the design \N\\Es euF{ied`/// \�����ce�isF•• ��� VICTOR HERNANDEZ PE # 72387 1 � No 7 87 � � _ Print Name No—� Cert # & Co. Cert Auth. - = BRENNAN ENGINEERI &,Orr 2 2018 ®�'Si� n re W to �I 1600 S. DIXIE HY STE 400 BOCA RATON FL. 33432 � pre f Company Name &Address N,„1P1l�-�\��\\ RdVW44 p b14