HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE" F ' J c7 - � Planning &Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 46
Certification for Design Load Compliance
Project Name: STANDARD PACIFIC HOMES - RIVERBEND.
Project Address: 3504 NW RADCLIFFE WAY - LOT 15
16 JpJ%
Departmen
1
1PerM1tt1n9 county
Permit #: 171 _ t✓ SCo 7 Occupancy Type: R-3 Construction Type: y.
INSTRUCTIONS FOR USE:
- 1
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS OSED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3.. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 170 mph X ASD LRFD End Zone Width: 61-60 ft
5. Mean Roof Height 251-0° ft Roof Pitch: 4 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -46 Zone 2: -80 Zone 3: -118 Zone 4: -52 Zone 5: -62 Garage: -52
7. Design Loads: Floor: 40/25 PSF Roof/Dead: 15/10 PSF Roof/Live: 20/10 Balcony: 6N30 PSF
Dock: N/A PSF Deck: N/A PSF Stairs: 40 PSF Fence: N/A PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes s
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
\C�f 6 ! � i als/o,0, tify that structural elements depicted on these plans provide adequate resistance to the design
\N\\Es euF{ied`///
\�����ce�isF•• ��� VICTOR HERNANDEZ PE # 72387
1 � No 7 87 � � _ Print Name No—� Cert # & Co. Cert Auth.
- = BRENNAN ENGINEERI &,Orr
2 2018
®�'Si� n re W
to �I 1600 S. DIXIE HY STE 400 BOCA RATON FL. 33432
� pre f
Company Name &Address
N,„1P1l�-�\��\\
RdVW44 p b14