Loading...
HomeMy WebLinkAboutSEWAGEr, RECEIVED JUL 13 2019 APPLIcATIoN #:AP1318542 STATE OF FLORIDA permitting Department PERMIT #:56-SF-1807597 DEPARTMENT OF HEALTH St. Lucie Countv DOCUMENT #: F11188907 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 12/07/2017 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID: FEE PAID :515.00 RECEIPT # :56-PI D-3448885 APPLICANT: Keith & Brandi Pearson AGENT: James Trefelner (]Yefelner Construcion Inc.) PROPERTY ADDRESS: 4780 Jorgensen Rd Fort Pierce, FL 34981 LOT: 81 SUBDIVISION: BLOCK: White City ID# : 3403-502-0144-030-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 123 I ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polyethylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [291 PRIVATE WELLS 87 FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] 1311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC3 2. [ ] [321 POTABLE WATER 50 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 5 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 5 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [11 679.2 (21 SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ' ] [121 NUMBER OF DRAINLINES 1. 5.00 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 07/11/2018 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 7.00 I ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] ['411 STORMWATER RUNOFF [ ] [191 DOSING PUMPS [ ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [461 FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [471 CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [221 FILL AMOUNT [ ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [231 FILL TEXTURE [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. [ APPROVED St. Lucie CHD CONSTRUCTION DATE: 05/23l2018 / DISAPPROVED ] ` Env ton ental Specialist II Bri� gram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: Lucie CHD DATE: 07/11/2018 Environmental Specialist II Brian Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Page 2 of 3 Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1318542 EID1807697 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment COMMen t a i APPLICATION #:AP1318542 PERMIT #:56-SF-1807597 DOCUMENT #:F11188907 DATE PAID:12/07/2017 FEE PAID :51 5.00 RECEIPT #:56-PID-3448885 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST and 5x12 long DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system, gutters, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1318542 EID1807597