HomeMy WebLinkAboutNOA - ALUMINUM SINGLE HUNG WINDOWM IAM I•DADE DEC 2 12017 MIAMI--DARE COUNTY ® PEWAII-TING PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOft&gg killynt` , FL 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy CGI Windows & Doors 10100 NW 25' Street Miami, FL 33172 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Sentinel110" Aluriiuumiingle Dung Winao�xL.M.I. APPROVAL DOCUMENT: Drawing No. W10-03, titled Series Sentinel 110 Alum. S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10, with revision C dated 04/10/15, prepared by A]- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. FISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the .performance of this product. TERMINATION of this NOA wi1l occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 14-0915.06 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 15-0512.10 Expiration Date: September 22, 2020 Appro at: eu ust 06 2015 yPage 1 CGI Windows & Doors A. DRAWINGS 1. Manufacturer's die 2. Drawing No W10- sheets 1 through 9 Al-Farooq CozporE •awings and sections. , titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", 9, dated 02/02/10, with revision C dated 04/10/15, prepared by >n, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spcer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marke -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulatini glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. 3. Test reports on: 1)1 Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2)� Large Missile Impact Test per FBC, TAS 201-94 3), Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to I ualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, TAS 202-94 along with marke -up drawings and installation diagram of a series "Sentinel" aluminum single ung window, prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.11) Manuel Pe , .E. Product Contro Wer xa NOA No. 12.10 Expiration Date: September 22, 2020 Approval Date: August 06 2015 E-1 CGI Windows & Doors NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-5th Edition (2014), dated 09/08/14, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under previous NOA No.14-0915.06) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their "Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA) for their "Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. 4. Notice of Acceptance No.14-0423.17 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 06/19/14, expiring on 05/21/16. F. STATEMENTS L Statement letter of conformance, complying with FBC-51 Edition (2014), and of no financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under previous NOA No.14-0915.06) 2. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.11) 3. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, Supervisor. G. OTHERS 1. Notice of Acceptance No. 14-0915.06, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I. approved on 02/05/15 and expiring on 09/22/20. luw"dz�D ManuelP.E. Product Contro Exa in NOA No. 12.13 Expiration Date: September 22, 2020 Approval Date: August 06 2015 E-2 6' MAX. HEAD/SILL CORNERS D 5 n .XG.. Ro J zq� 5 n r n FALSE MUNITNS (WR a APPLIED) 1 /2' NAK HE "SRL CORNERS J B . Ca �� pp R° L7 7/16' to D.LO. (VENT) 50 1/P VENT WIDTH FLANGE & FLANGE ADAPTOR FRAME FLANGE WIDTH 47 7/16' DLO. (FIX. PRE) 2D 9/16' *# YAK A H61O/SLL 4 11 / II II B li II t it II / II II II n n C SERIES SENTINEL 110 ALUMINUM SINGLE HUNG WINDOW DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEEF 2. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WOW. WITH OTHER MIAMI-DARE COUNTY APPROVED WINDOWS USING MWMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (WHZ). WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TD THE STRUCTURE ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DEAILS ARE NOT PART OF THIS APPROVAL A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. MATERIALS INCLUDING BUT NOT LIMITED TO STEE/UETAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERVJS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE BUCK WIDTH 47 7/16'. D.L.O. (FIX. LITE) 20 9/16' ## YA)f. AI HEAD/SILL 8 g II i� 11 D A8 IySI 47 7/16'z D.L.O. (yam 50 1/4' VENT WIDTH EQUAL LEG FRAME CENTER ANCHOR REQUIRED WHEN SPACING EXCEEDS 20 9/16" FALSE MUNITNS �OPPIIONAI APPLIED) GF �a rc FIN FRAME LAMINATED GLASS INSULATING LAM. GLASS LARGE MISSILE IMPACT SMALL MISSILE IMPACT I. N 3 P3 O Lu cmwing no. W10-03 o clz 0 vpv A Z � HEIGHT KD n m rn _c m6m c 0 �o SIn m u mZny 7 I nm � c y 11 e m�� Nx��N�aa G x � SL 04. r�o�pm4. s� Lq m HEIGHT yO n r pS� tFA b Y�fx t� Yb T w b b b b 5 O b b V - � fn Q � o b bbb b 0 p yy ,s• N V a-1�4• V !! b�.>nw�Pny VENT a'� o FLANGE DIMS. �p lz YI � OW Ng �� Duac DIM. o IENcnI R) m ama oz-az-lo Ms.— _ _ SERIES SENTINEL I10 ALUM S.H. WOW. (LM.I./S.M.I.) AL-FAROOQ CORPORATION a no a e .es- ion Q °°°'a i7�•' I• " '° "�"a' CGI WINDOWS & DOORS MmD�56 PRODMCf pE1/ElOPMINf uwam m min mC .-1 I,S.W.M AVE a I o a. q: ,;s pus�.xs srtn MIAMI N.W. 25TH STREET muuxt, FIARIDA 331]4 `. -^ O MIAMI, fL 33172 TEL(9pc1 ze4eioo FAc caos>zez4s�ze u) G1 P °Ms by. TEL (]05) 5 -559G FA%. "— 593-8592 COMP-ANL WI0-OJCGI �TP�my'PY�nyF��f:�T'PY$�FY�$Y4P�� ama Nm- Sm Nma pQ • • • a Naa �a�, ama aa�R9m Y 9 M Y� Y b b b P g V� t� N 1.0 Y I� V u H P N Y a� b 5 b I°n}nbb �i, �nub�!&F!m^P�bYfi G�H��N�NNb�u �� 1/4' AIR 1/8' ANN. I s ANN. GLASS J.CGRNNG995 'N'D GLASS .075' Int dger ' Mtedayer San. CP With PET Core es CP WKh PET Core R'Eastman Chemlaol Co.' Eastman Chemlwl Co: 090' Intedger , Interlayer 0 Senaz Clwr AM Color Glass % Clear ArM Color Clroa By 'Eastman Chemlwl W Eastman Chemical Co: Q LL DR ppp 090' Intedayer ' Intodgar Kureray SantryGlae rey SentryClw O By 'Kunray America, Inc.' OR Kunray America, In.' OR 090' Inledger ' Intadayx 0 Kunray Butadte PVS nsy Butaalte P. O By 'Kunray Amedw, Irn).' K—nay America, Inc.'a 01/8' ANN. GLASS 1/8' NEAT STREN'D GLASS O8]at S CORE GE 11200 GE 11200SILICONE DOW CORNING 899 DOW CORNING 899 DOW CORNING 995 --1 OOW CORNING 995 O I AT 1/4 POINTS ON LRES W Y4 WOFR Tt1AN Js' G ASI S TYPE 'A' 5/1V OVERALL LAB. GLASS (L.M.1 & S.M.I.) 1/8' ANN. CUSS 075' Interlayer San- CP Wlh PET Core W'Eastman Chemical Co.' OR .090' Intadgar Saner Clear And Color Glaes By 'Eastman Chemical Co.' OR ;PACE 090' Inteloayyee Kunray Sent 6- A55 By 'Kunay Amedaa. Inc.' OR InIld By -K y BulgaABe PVT' 1/8' HEAT By Kurarq America, Inc.' r1/8' ANN. GLASS M7 DOW CORNING B99 \ O DOW CORNING 995 KL EOGE SPACER Sr. STEEL By 'cwoiKAL' OR 0 OUR0.5EAL OR eY 'QUANEK' A EB SUPER SPACER BY 'OUANIX' M4 Al 1/4 POINTS ALL SIBS G ARa TYPE 'At' 0.70. OVERALL INSUL wA. CUSS (L.M.I ONLY) (S.M.1.) IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING EKTERIOR PLY OF GLASS TYPE 'A1' & '01' MUST BE TEMPERED. O / I RAT 1/4 POINTS ON UtS WDER THAN 06' GLASS TYPE 'R' 5/1V OVERALL LAM. MASS 1/8' HEAT STREN'D GLASS .075' Inledoyer Sagas CP WM PET Core R'Eastman Chemical Co.' .090' Inledaym Sagas Caar And Coear Glass By 'Eastman ChemTc.I Co.' AIR SPACE OR 090' Intadaayy rr Kuraray SenVyclas By 'Numrq Amerca, Inc.' OR 0 GLASS 090' Inledoyer Kunay BulaARe PVB By 'Kunray America. fnc.' 1/8' HEAT STREN'D CLASS 3 y SILICONE GE M j M1 O CORN) DOW CORNING 899 DOW CORNING 995 KL EDGE SPACER ST. STEEL BY 'CARDINAL' C O OR DUR/SEAL BY 'QBANIX' C 4 E9 OR SUPER SPACER Br 'OUANIX' M4 AT 1/4 POINTS ALL SIZES GIASS TYPE 'RI' 0.70. OVERALL INSUL LAN. GLASS uauP PROOL1=11VISED y'p 70592 Plyigq,vYA rim Fbrids T 09 cci a AN enpNam No I5'0! .'Q iwlm DON � 8. b 3 UU 2015112.D dePramrn drm.ing na. W10-03 4 FLANGE & FLANGE ADAPTOR FRAME z a/�'� WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%'. THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. ANCHORS FF--=—==_______ _--1'I jl MIAMI-DARE COUNTY APPROVED II II SEE SEPARATE MOAN ANCHORS II KEDGE DIST. �I I II I TYPICAL ANCHORS SEE REV. FOR SPACING WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WOW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE TYPICAL ANCHORS: SEE ELEV. FOR SPACING 1/4' OIA. TAPCON BY 'TTVf (F-120 KSI, Fy..92 KSI) 1 /4' DIA ULTRACON BY 'ELCO(F-m KSI, ry-m KSI) INTO 29Y WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONC. OR MASONRY 1-1/4' MIN. EMBED INTO CONIC. OR MASONRY DIRECTLY INTO CONIC. OR MASONRY 1-1/4" MIN. EMBED INTO CONC. OR MASONRY i14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO METAL STRUCTURES STEEL : 12 GA. MIN. (Fy - 36 KSI MIN.) ALUMINUM : 1/B' THK. MIN. (6053-T5 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 014 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO MIAMI-DADE COUNTY APPROVED MUWONS (MIN. THK. = .090-) (NO SHIM SPACE) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2' MIN. INTO WOOD STRUCTURE - 1' MIN. INTO METAL STRUCTURE = 3/4" MIN, WOOD AT HEAD, SILL OR JAMBS SO - 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS 1'. - 3000 PSI MIN. C-90 HOLLOW/RLLm BLOCK AT JAMBS Pm - 2000 PSI MIN. Gar: JAW AWD PRODUCTREV15m PE C tL -m1pl*g with ds Flmdda M T0.5�� 5]6 8 92 A-P /-p$12.10 rmwn O.s<e 2D20 BY tdimoi PlodtA4 1 Q ZQ)? m 4,; z 2� a 09 IL 0° 0t a V ° m 0; oam� LLz� a H. 1x FOR O 1/4- LAX. TIVICAL ANCHORS � OE SEE ELEV. FOR S4/ G WOOD BUCKS X 1' FH. SMS. EXTERIOR ... FLANGE & FLANGE ADAPTOR FRAME 7m FWDOD R WOOD SIR w000 BUCKS FLANGE ADAPTOR FRAME to 0 _ EI I I O a 0 a w i X I w I O E2 1 INTALLATION DETAILS SHOWN ON PAGES 4 AND 5 APPLY TO BOTH FLANGE FRAME AND FLANGE ADAPTOR FRAMES. 1XW0 PRODUCE REVISED •K E0393 c9mp1yin8 wDEJwfl9nd� s � ewlmve cva< a9�t�9wl5•o5L7.ln � � s vv Dern D 9 8 / EY 201� W 10-03 Pro4 drawing no. EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY INTO WOOD, CONCRETE OR METAL STRUCTURES WITHOUT THE NEED OF A WOOD BUCK. WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%'. THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. EQUAL LEG FRAME -------------------- ------------------ jI NL1NI-DADE COUNTY APPROV �j I UWON k MULLION ANCHORS I II SEE SEPARATE NOA II 11 mGE p5f. �1 1 11 II TYPICAL ANCHORS SEE ELEV. FOR SPACING 2015 \_TYPICAL ANCHORS SEE ELEV. FOR SPACING FRODUCf RrS.- r camplyug wuh Nw FlaidA Baiidin CO&wN 12.1Q AcaP roNo! Y E, I! ny M>®I WProduel drawing no. W10-03 �s EXTERIOR ro LNJ � �m 1 1/2' Q a O w LJ N � N 0 rL me: oz-ez-la rehslow SERIES SFMINEL I IO ALUM S.R. WOW. (LM.I./S.M.I a no a ese� own CGI WINDOWS & DOORS uwum ro roi. 10100 I N.W. 25TH STREET a. or• c o .1o.0 w xe ce n9 9a O � MIAMI, FL 33172 L4 4L M• TEL (305) 593-6590 1". (305) 593-6592 AL-FAROOQ CORPORATION (a SR ROMRS & PRODUCT DEYEIOPM Illl 1 1235 SW. 87 AV Mmml, FLORIDA 33174 9 Mo.)2648100 `—mo5)29249]6 a z.sos �x.sas� 1.745 I 81I J45 065 1.245 .749 .065 —J' ttP. TP. IM15 E12 FLANGE FRAME HEAD E1 FLUSH FRAME HEAD IN FLANGE FRAME SILL I OO FLUSH FRAME SILL 1.007 .7pinr �z 1.J66 1.019 E4 MEERNG RAIL .500 1.J01 I.J<7f L O69 A69 00 >�— TP. 11P. 7.015 24/0 2 "o 1.015 1.015 O LOCN RAIL. 2546 .490 .]05 .050 TP. .66a .120 .]OS .050 TP. s64 1.09J I Ea A15 P BAND RAIL Ee 5/16' GLAZING BEAD O .700- GLAZING BEAD 1.025 Tlass Jay ,065 1 1 a95 1w .ow.U&9 lAI9 2sJ .060 talc uJ FLUSH FRAME COVER 1a SCREW COVER l"J SJSH RAIL FRAME TOP CORNER rI.95D 1W sso .oso � E10 FLANGE ADAPTOR 4 4 Z e m 3 O `W • � O: G 06 a N �aa0 z D"q LLfd�e j3mE0,1 Q s ai xi F VENT TOP CORNER c s In 3 } 3 O w 03M� VENT BOTTOM CORNER PRODULTREN9FD Ui 0592 pIyi6wid+fh,F70ideIIUIUIIIL 6 Accel�xNu IS-061'Z,Ja � E i,sl on Due 40$f) 8 b 6y drvwing no. nmeP 01015 W10-03