FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
- _ Florida Department of Business and Professional Regulation - Residential Performance Method
%if�.0 li�"e7 n
Project Name: SALGADOSA RESIDENCE
Builder Name:
0
MAY ����
Street: HARTMAN ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
PERMITTING
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 ) St. Lucie County, FL
1. New construction or existing
New (From Plans)
9. Wall Types (1990.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1990.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
4
d. N/A
R= ft2
10. Ceiling Types (2493.0 sgft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 2493.00 ft2
6. Conditioned floor area above grade (ft2)
2493
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(257.0 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: AHU
6 200
a. U-Factor: Sgl, U=0.65
257.00 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
46.5 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
- d. U-Factor: N/A
ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2493.0 sgft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 2493.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.103
Total Proposed Modified Loads: 73.07
PASS
Total Baseline Loads: 78.43
I hereby certify that the plans and specifications covered by
Review of the plans and
ST•q?�
this calculation are in compliance with
the Florida Energy
specifications covered by this
04SKE
Code.
calculation indicates compliance
yri` a„'''' `'€s'•����
th the Florida Energy Code.
/fill i
PREPARED BY:
ore construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
�. I I a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
J
G'ODwt
with the Florida Ener e.
OWNER/AGENtj o o
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title:
SALGADOSA RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2493
Lot #
Owner:
Total Stories:
1
Block/SubDMsion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
-
Rotate Angle:
0
Street:
HARTMAN ROAD
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Ebsting:
New (From Plans)
Comment:
CLIMATE
IECC
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
Zone
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2493
25224
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BATH
60
600 No
0
1
Yes
Yes
Yes
2
WIC
30
300 No
0
1
Yes
Yes
Yes
3
BEDROOM 4
210
2100 No
0
1
1
Yes
Yes
Yes
4
BEDROOM 3
168
1680 No
0
1
1
Yes
Yes
Yes
5
CLST 3
14
140 No
0
1
No
Yes
Yes
6
BATH 2
60
600 No
0
1
Yes
Yes
Yes
7
BEDROOM 2
166
1660 No
0
1
1
Yes
Yes
Yes
8
CLST 2
16
160 No
0
1
No
Yes
Yes
9
LAUNDRY
76
760 No
0
1
Yes
Yes
Yes
10
AHU
15
150 No
0
1
No
Yes
Yes
11
LINEN
10
100 No
0
1
No
Yes
Yes
12
HALLWAY
128
1280 No
0
1
No
Yes
Yes
13
KITCHEN
315
3150 Yes
0
1
Yes
Yes
Yes
14
FAMILY ROOM
294
3234 No
0
1
No
Yes
Yes
15
DINING
213
2130 No
0
1
Yes
Yes
Yes
16
FOYER
60
600 No
0
1
Yes
Yes
Yes
17
MASTER BEDROO
294
2940 No
0
1
1
Yes
Yes
Yes
18
WIC 2
24
240 No
0
1
No
Yes
Yes
19
WIC 1
42
420 No
0
1
Yes
Yes
Yes
20
MASTER BATH
135
1350 No
0
1
Yes
Yes
Yes
21
DEN
163
1630 No
0
1
Yes
Yes
Yes
3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
BATH
16 ft
0
60 ftZ
____
1
0
0
2 Slab -On -Grade Edge Insulation
WIC 4
5 ft
0
30 ft2
____
1
0
0
3 Slab -On -Grade Edge Insulation
BEDROOM 4
14 ft
0
210 ft2
___
1
0
0
4 Slab -On -Grade Edge Insulation
BEDROOM 3
13 ft
0
168 ft2
__e
1
0
0
5 Slab -On -Grade Edge Insulation
CLST 3
1 ft
0
14 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
BATH 2
6 ft
0
60 ft2
1
0
0
7 Slab -On -Grade Edge Insulation
BEDROOM 2
13 ft
0
166 ft2
___
1
0
0
8 Slab -On -Grade Edge Insulation
CLST 2
1 ft
0
16 ftZ
1
0
0
9 Slab -On -Grade Edge Insulation
LAUNDRY
5ft
0
76 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
AHU
1 ft
0
15 ft2
____
1
0
0
11SIab-On-Grade Edge Insulation
LINEN
1 ft
0
10 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
128 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
KITCHEN
21 ft
0
315 ftZ
1
0
0
- 14SIab-On-Grade Edge Insulation
FAMILY ROOM
1 ft
0
294 ftZ
1
0
0
15SIab-On-Grade Edge Insulation
DINING
19 ft
0
213 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
FOYER
6ft
0
60 ft'
__e
1
0
0
17SIab-On-Grade Edge Insulation
MASTER BEDRO
37 ft
0
294 ft2
____
1
0
0
18SIab-On-Grade Edge Insulation
WIC 2
1 ft
0
24 ft2
___-
1
0
0
19SIab-On-Grade Edge Insulation
WIC 1
6ft
0
42 ft2
__e
1
0
0
20SIab-On-Grade Edge Insulation
MASTER BATH
9 ft
0
135 ftZ
____
1
0
0
21SIab-On-Grade Edge Insulation
DEN
29 ft
0
163 ft'
____
1
0
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
v # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip Metal 2700 ft2
0 ft2
Medium
0.6
No 0.9
No
0
22.6
ATTIC
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
2493 ft2
N N
3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BATH
30
Blown
60 ft2
0.1
Wood
2
Under Attic (Vented) WIC 4
30
Blown
30 ft2
0.1
Wood
3
Under Attic (Vented) BEDROOM 4
30
Blown
210 ft2
0.1
Wood
4
Under Attic (Vented) BEDROOM 3
30
Blown
168ft2
0.1
Wood
5
Under Attic (Vented) CLST 3
30
Blown
14 ft2
0.1
Wood
6
Under Attic (Vented) BATH 2
30
Blown
60 ft2
0.1
Wood
7
Under Attic (Vented) BEDROOM 2
30
Blown
166 ft2
0.1
Wood
8
Under Attic (Vented) CLST 2
30
Blown
16 ft2
0.1
Wood
9
Under Attic (Vented) LAUNDRY
30
Blown
76 ft2
0.1
Wood
10
Under Attic (Vented) AHU
30
Blown
15 ft2
0.1
Wood
11
Under Attic (Vented) LINEN
30
Blown
10 ft2
0.1
Wood
12
Under Attic (Vented) HALLWAY
30
Blown
128 ft2
0.1
Wood
13
Under Attic (Vented) KITCHEN
30
Blown
315ft2
0.1
Wood
14
Under Attic (Vented) FAMILY ROOM
30
Blown
294 ft2
0.1
Wood
15
Under Attic (Vented) DINING
30
Blown
213 ft2
0.1
Wood
16
Under Attic (Vented) FOYER
30
Blown
60 ft2
0.1
Wood
17
Under Attic (Vented) MASTER BEDRO
30
Blown
294 ft2
0.1
Wood
18
Under Attic (Vented) WIC 2
30
Blown
24 ft2
0.1
Wood
19
Under Attic (Vented) WIC 1
30
Blown
42 ft2
0.1
Wood
20
Under Attic (Vented) MASTER BATH
30
Blown
135 ft2
0.1
Wood
21
Under Attic (Vented) DEN
30
Blown
163 ft2
0.1
Wood
-
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
It
Qmt
Space
In Wall T4pe
1
N
Exterior Concrete Block - Ext Insul BATH
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
2
W
Exterior Concrete Block - Ext Insul BATH
4.1
10
0 10
0
100.0 ft2
0
0
0.6
0
3
W
Exterior Concrete Block - Ext Insul WIC 4
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
4
N
Exterior Concrete Block - Ext Ins8EDROOM 4
4.1
14
0 10
0
140.0 ft2
0
0
0.6
0
5
W
Exterior Concrete Block - Ext InsiBEDROOM 3
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
6
W
Exterior Concrete Block - Ext Insul BATH 2
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
7
W
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
8
E
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
9
N
Exterior Concrete Block - Ext Insul KITCHEN
4.1
21
0 10
0
210.0 ft2
0
0
0.6
0
10
E
Exterior Concrete Block - Ext Insul DINING
4.1
3
0 10
0
30.0 ft2
0
0
0.6
0
11
S
Exterior Concrete Block- Ext Insul DINING
4.1
16
0 10
0
160.0 ft2
0
0
0.6
0
12
S
Exterior Concrete Block - Ext Insul FOYER
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
13
N
Exterior Concrete Block - Ext InsWASTER BE
4.1
15
0 10
0
150.0 ft2
0
0
0.6
0
14
E
Exterior Concrete Block - Ext InsLKIASTER BE
4.1
18
0 10
0
180.0 ft2
0
0
0.6
0
15
W
Exterior Concrete Block - Ext InsLMASTER BE
4.1
4
0 10
0
40.0 ft2
0
0
0.6
0
16
E
Exterior Concrete Block- Ext Insul WIC 1
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
17
E
Exterior Concrete Block - Ext InsMASTER BA
4.1
9
0 10
0
90.0 ft2
0
0
0.6
0
18
E
Exterior Concrete Block - Ext Insul DEN
4.1
13 •
0 10
0
130.0 ft2
0
0
0.6
0
19
S
Exterior Concrete Block - Ext Insul DEN
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar Below
20 W
Exterior Concrete Block - Ext Insul DEN
4.1 3 0 10 0 30.0 ft2
0
0 0.6
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Ft
Width
In
Height
Ft In
Area
1
N
Insulated
BATH
None
.39 2
8
8
21.3 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame
Panes
NFRC
U-Factor SHGC
Overhang
Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
8
9
- 10
N 4 Metal
W 5 Metal
W 7 Metal
N 9 Metal
S 11 Metal
S 12 Metal
N 13 Metal
E 14 Metal
E 18 Metal
S 19 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
15.0 ft2 2 ft 0 in
15.0 ft2 2 ft 0 in
15.0 ft2 2 ft 0 in
48.0 ft2 2 ft 0 in
36.0 ft2 2 ft 0 in
48.0 ft2 2 ft 0 in
20.0 ft2 2 ft 0 in
20.0 ft2 2 ft 0 in
20.0 ft2 2 ft 0 in
20.0 ft2 2 ft 0 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
575 ft2
384 ft2
19 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50)
.00045
2942.8 161.56 303.83 .3285
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COP:1
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
Split
SEER: 16
46.5 kBtu/hr 1395 cfm
0.8 1
sys#1
3/22/2017 3:43 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2014
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart #
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
/
— Supply --
— Return --
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1
Attic
6 200 ft2
Attic
20 ft2 Default Leakage
AHU
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan
HeatinJan
Feb
Feb
[ ] Mar
[X] Mar
f
Apr
Apr
r May Jun Jul
[ May Jun Jul
Auge
AuSep
r
[ ]Oct
Oct r
[X]
Nov
Nov
] Dec
[X] Dec
Ventin Jan
Feb
[X] Mar
[X]
Apr
[[[ ]]] Ma Jun Jul
Aug
Se
[[[XXX]]]
Oct [[[XXX]]]
Nov
[[ ]] Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
80
80 78 78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
80
80 78 78
78
78
78
78
78
78
Heating (W D)
AM
65
65
65
65 65 65
65
68
68
68
68
68
'
PM
68
68
68
68 68 68
68
68
68
68
68
68
Heating (W EH)
AM
65
65
65
65 65 65
65
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
68
68
3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SALGADOSA RESIDENCE Builder Name:
Street: HARTMAN ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
`
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
3/22/2017 3:44 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY
PERFORMANCE LEVEL (EPL)
- -
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
HARTMAN ROAD, FORT PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior
R=4.1
1990.00 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
4 d. N/A
R=
ft2
5. Is this a worst case?
No 10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
2493.00 ft2
6. Conditioned floor area (ft2)
2493 b. N/A
R=
ft2
7. Windows— Description
Area c. N/A
R=
ft2
a. U-Factor: Sgl, U=0.65
257.00 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU
R ft2
6 200
SHGC: SHGC=0.25
' b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
46.5 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2493.00 ft2 a. Electric
EF: 0.98
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed mpli t features.
Builder Signature: ? Date:
Address of New Home r qQ y>ja!6_ r/ City/FL Zip: 31�C� j ay
t- I V L-cw C� aft,
This is not a Building. Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/22/2017 3:44 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1