Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEA File Copy. dk FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION - _ Florida Department of Business and Professional Regulation - Residential Performance Method %if�.0 li�"e7 n Project Name: SALGADOSA RESIDENCE Builder Name: 0 MAY ���� Street: HARTMAN ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: PERMITTING Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) St. Lucie County, FL 1. New construction or existing New (From Plans) 9. Wall Types (1990.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1990.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2493.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2493.00 ft2 6. Conditioned floor area above grade (ft2) 2493 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(257.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 6 200 a. U-Factor: Sgl, U=0.65 257.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency - d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2493.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2493.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.103 Total Proposed Modified Loads: 73.07 PASS Total Baseline Loads: 78.43 I hereby certify that the plans and specifications covered by Review of the plans and ST•q?� this calculation are in compliance with the Florida Energy specifications covered by this 04SKE Code. calculation indicates compliance yri` a„'''' `'€s'•���� th the Florida Energy Code. /fill i PREPARED BY: ore construction is completed DATE: this building will be inspected for compliance with Section 553.908 �. I I a I hereby certify that this building, as designed, is in compliance Florida Statutes. J G'ODwt with the Florida Ener e. OWNER/AGENtj o o BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: SALGADOSA RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2493 Lot # Owner: Total Stories: 1 Block/SubDMsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: - Rotate Angle: 0 Street: HARTMAN ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2493 25224 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BATH 60 600 No 0 1 Yes Yes Yes 2 WIC 30 300 No 0 1 Yes Yes Yes 3 BEDROOM 4 210 2100 No 0 1 1 Yes Yes Yes 4 BEDROOM 3 168 1680 No 0 1 1 Yes Yes Yes 5 CLST 3 14 140 No 0 1 No Yes Yes 6 BATH 2 60 600 No 0 1 Yes Yes Yes 7 BEDROOM 2 166 1660 No 0 1 1 Yes Yes Yes 8 CLST 2 16 160 No 0 1 No Yes Yes 9 LAUNDRY 76 760 No 0 1 Yes Yes Yes 10 AHU 15 150 No 0 1 No Yes Yes 11 LINEN 10 100 No 0 1 No Yes Yes 12 HALLWAY 128 1280 No 0 1 No Yes Yes 13 KITCHEN 315 3150 Yes 0 1 Yes Yes Yes 14 FAMILY ROOM 294 3234 No 0 1 No Yes Yes 15 DINING 213 2130 No 0 1 Yes Yes Yes 16 FOYER 60 600 No 0 1 Yes Yes Yes 17 MASTER BEDROO 294 2940 No 0 1 1 Yes Yes Yes 18 WIC 2 24 240 No 0 1 No Yes Yes 19 WIC 1 42 420 No 0 1 Yes Yes Yes 20 MASTER BATH 135 1350 No 0 1 Yes Yes Yes 21 DEN 163 1630 No 0 1 Yes Yes Yes 3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BATH 16 ft 0 60 ftZ ____ 1 0 0 2 Slab -On -Grade Edge Insulation WIC 4 5 ft 0 30 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation BEDROOM 4 14 ft 0 210 ft2 ___ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 3 13 ft 0 168 ft2 __e 1 0 0 5 Slab -On -Grade Edge Insulation CLST 3 1 ft 0 14 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 60 ft2 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 2 13 ft 0 166 ft2 ___ 1 0 0 8 Slab -On -Grade Edge Insulation CLST 2 1 ft 0 16 ftZ 1 0 0 9 Slab -On -Grade Edge Insulation LAUNDRY 5ft 0 76 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation AHU 1 ft 0 15 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation LINEN 1 ft 0 10 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 128 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation KITCHEN 21 ft 0 315 ftZ 1 0 0 - 14SIab-On-Grade Edge Insulation FAMILY ROOM 1 ft 0 294 ftZ 1 0 0 15SIab-On-Grade Edge Insulation DINING 19 ft 0 213 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation FOYER 6ft 0 60 ft' __e 1 0 0 17SIab-On-Grade Edge Insulation MASTER BEDRO 37 ft 0 294 ft2 ____ 1 0 0 18SIab-On-Grade Edge Insulation WIC 2 1 ft 0 24 ft2 ___- 1 0 0 19SIab-On-Grade Edge Insulation WIC 1 6ft 0 42 ft2 __e 1 0 0 20SIab-On-Grade Edge Insulation MASTER BATH 9 ft 0 135 ftZ ____ 1 0 0 21SIab-On-Grade Edge Insulation DEN 29 ft 0 163 ft' ____ 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2700 ft2 0 ft2 Medium 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2493 ft2 N N 3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BATH 30 Blown 60 ft2 0.1 Wood 2 Under Attic (Vented) WIC 4 30 Blown 30 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 4 30 Blown 210 ft2 0.1 Wood 4 Under Attic (Vented) BEDROOM 3 30 Blown 168ft2 0.1 Wood 5 Under Attic (Vented) CLST 3 30 Blown 14 ft2 0.1 Wood 6 Under Attic (Vented) BATH 2 30 Blown 60 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 166 ft2 0.1 Wood 8 Under Attic (Vented) CLST 2 30 Blown 16 ft2 0.1 Wood 9 Under Attic (Vented) LAUNDRY 30 Blown 76 ft2 0.1 Wood 10 Under Attic (Vented) AHU 30 Blown 15 ft2 0.1 Wood 11 Under Attic (Vented) LINEN 30 Blown 10 ft2 0.1 Wood 12 Under Attic (Vented) HALLWAY 30 Blown 128 ft2 0.1 Wood 13 Under Attic (Vented) KITCHEN 30 Blown 315ft2 0.1 Wood 14 Under Attic (Vented) FAMILY ROOM 30 Blown 294 ft2 0.1 Wood 15 Under Attic (Vented) DINING 30 Blown 213 ft2 0.1 Wood 16 Under Attic (Vented) FOYER 30 Blown 60 ft2 0.1 Wood 17 Under Attic (Vented) MASTER BEDRO 30 Blown 294 ft2 0.1 Wood 18 Under Attic (Vented) WIC 2 30 Blown 24 ft2 0.1 Wood 19 Under Attic (Vented) WIC 1 30 Blown 42 ft2 0.1 Wood 20 Under Attic (Vented) MASTER BATH 30 Blown 135 ft2 0.1 Wood 21 Under Attic (Vented) DEN 30 Blown 163 ft2 0.1 Wood - WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below It Qmt Space In Wall T4pe 1 N Exterior Concrete Block - Ext Insul BATH 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Ext Insul BATH 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Ext Insul WIC 4 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Ext Ins8EDROOM 4 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Ext InsiBEDROOM 3 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 6 W Exterior Concrete Block - Ext Insul BATH 2 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Ext InstBEDROOM 2 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 8 E Exterior Concrete Block - Ext InsuILAUNDRY 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 9 N Exterior Concrete Block - Ext Insul KITCHEN 4.1 21 0 10 0 210.0 ft2 0 0 0.6 0 10 E Exterior Concrete Block - Ext Insul DINING 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 11 S Exterior Concrete Block- Ext Insul DINING 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Ext InsWASTER BE 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block - Ext InsLKIASTER BE 4.1 18 0 10 0 180.0 ft2 0 0 0.6 0 15 W Exterior Concrete Block - Ext InsLMASTER BE 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 16 E Exterior Concrete Block- Ext Insul WIC 1 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block - Ext InsMASTER BA 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block - Ext Insul DEN 4.1 13 • 0 10 0 130.0 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Ext Insul DEN 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 20 W Exterior Concrete Block - Ext Insul DEN 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width In Height Ft In Area 1 N Insulated BATH None .39 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 - 10 N 4 Metal W 5 Metal W 7 Metal N 9 Metal S 11 Metal S 12 Metal N 13 Metal E 14 Metal E 18 Metal S 19 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 15.0 ft2 2 ft 0 in 15.0 ft2 2 ft 0 in 15.0 ft2 2 ft 0 in 48.0 ft2 2 ft 0 in 36.0 ft2 2 ft 0 in 48.0 ft2 2 ft 0 in 20.0 ft2 2 ft 0 in 20.0 ft2 2 ft 0 in 20.0 ft2 2 ft 0 in 20.0 ft2 2 ft 0 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in None None None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 575 ft2 384 ft2 19 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .00045 2942.8 161.56 303.83 .3285 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 3/22/2017 3:43 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply -- — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage AHU (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Feb Feb [ ] Mar [X] Mar f Apr Apr r May Jun Jul [ May Jun Jul Auge AuSep r [ ]Oct Oct r [X] Nov Nov ] Dec [X] Dec Ventin Jan Feb [X] Mar [X] Apr [[[ ]]] Ma Jun Jul Aug Se [[[XXX]]] Oct [[[XXX]]] Nov [[ ]] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 ' PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/22/2017 3:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SALGADOSA RESIDENCE Builder Name: Street: HARTMAN ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the ` insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 3/22/2017 3:44 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) - - DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. HARTMAN ROAD, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1990.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 2493.00 ft2 6. Conditioned floor area (ft2) 2493 b. N/A R= ft2 7. Windows— Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.65 257.00 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU R ft2 6 200 SHGC: SHGC=0.25 ' b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 46.5 SEER:16.00 SHGC: d. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2493.00 ft2 a. Electric EF: 0.98 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed mpli t features. Builder Signature: ? Date: Address of New Home r qQ y>ja!6_ r/ City/FL Zip: 31�C� j ay t- I V L-cw C� aft, This is not a Building. Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/22/2017 3:44 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1