Loading...
HomeMy WebLinkAboutEVALUATION REPORT ROOFING UNDERLAYMENTCREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, a ,EDITION (2014) Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued August 22, 2016 P.O. Box 1404 Joplin, MO 64802 (417) 624-6644 I htto:tlwww.tamko.com ST. LCC?F COL'N ,yDL 'NGiD Quality Assurance: UL LLC (QUA9625) RFVIEWED FOR C ? , 1tl�.VIE:YED $ DATE IT MU T AE PT ON JOB PLAtdS AN P.... SCOPE OR NO ' PECTIO?. WILL BE MADE' Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.4.5.3, 1507.5.3, 1507.5.3.2, 1507.6.3, 1507.6.3.2, 1507.6.5, 1507.7.3, 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.8.8, T1507:8, 1507.9.3, 1507.9.3.2, 1507.9.5, 1507.9.9 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies (TST6049) TAP-191-02-01 REV ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) TAP-192-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) TAP-193-02=01 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) TAP-214-02-01 ASTM D 4869 2005e01 ,PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2006 .PRI Construction Materials Technologies (TST6049) TAP 216-02-03 ASTM D 6380 2003(2009) PRI Construction Materials Technologies (TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2009) PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2006 PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2006 PRI Construction Materials Technologies (TST6049) TAP-220-02-01 ASTM D 6380 2003(2009) PRI Construction Materials Technologies (TST6049) TAP-222-02-01 ASTM D 4869 2005e01 PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 ACC 188 2012 UL LLC (TST9628) 13CAl2269 ASTM D 226 2006 PRODUCT DESCRIPTION AND APPLICATION TAMKO® ASTM Slate ASTM D 6380, Class M, Type 11 underlayment constructed from organic felt saturated Tit§NbNWPftbflR@POSFMfffQRNhalt and coated on both sides with asphalt and surfaced with granules. ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORQjWope: 2:12 MAY 138 NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE C Pbation: The underlayment shall be installed with minimum 2" side laps and minimum 4" staggered end laps and in accordance with FRSAITRI 07230 for tile applications. Allowable roof coverings: Attachment of asphalt shingle valleys and clay and concrete the shall be permitted in accordance with CONCEALED FASTENERS OR ATTACHMENTS theFBC. ARE THE RESPONSIBILITY OF THE TBP1400O.3� GTOR OP flIAGQRD FL12328-R7 Page I of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer sv as -tlfy CREEK Technical Services, LLC of any product changes or quality assurance changes throughout tt -o� tton� q wh Outesthatare s re�� valid. This evaluation report does not express nor imply warranty, installation, recommended use, t p a WA specifically addressed herein. _ r 0 CREEK TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO® ASTM Tile ASTMD 6380, Class M, Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" staggered end laps and in accordance with FRSA/TRI 07230 for tile applications. Allowable roof coverings: Attachment of clay and concrete tile shall be permitted in accordance with the FBC. TAMKO® Master ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. Application: The underlayment shall be installed along the valley in accordance with FBC requirements. Allowable roof coverings: Attachment of asphalt shingle valleys shall be permitted in accordance with the FBC. TAMKO® Moisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard Plus® with a mineral surfacing and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 3-1/2" side laps and minimum 6" staggered end laps. Min. application temperature: 40°F. Allowable roof coverings: Attachment of asphalt shingles and mechanically fastened concrete and clay the roofing shall be permitted in accordance with the FBC. TAMKO® No.15 ASTM ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO® No. 15 UL ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles, metal 'roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TBP14001.3 FL12328-R7 Page 2 of 4 This evaluation report is;provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services., LLC of-any.product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other.product attributes that are not specifically addressed herein. TAMKO BUILDING PRODCUTS, INC. CREEKTAMKO Underlayments TECHNICAL SERVICES, LLC Mal I o. 0 M ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is Ephalt urated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, clay and concrete tile, slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO® No. 30 UL ASTM D 226, Type II underlayment constructed, from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, clay and concrete tile, slate shingles, wood shingles, wood shakes, and .roll roofing shall be permitted in accordance with the FBC. TAMKO@) TW Metal and Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Tile Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6" staggered end laps. Min. application temperature: 40°F Allowable roof coverings: Attachment of asphalt shingles, metal roofing, and mechanically fastened clay -and concrete tiles shall be permitted in accordance with the FBC. TAMKO®TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to theroof deck with minimum 4" side laps and minimum 6" staggered end laps. Min. application temperature: 40OF Allowable roof coverings: Attachment of asphalt shingles and metal roofing shall be permitted in accordance with the FBC. TAMKOI)TAM-FELT Alternate to ASTM D 226, Type I and: Type II underlayment constructed from a non - perforated organic felt that is saturated with asphalt. Application: The underlayment shall be installed with minimum 2" side laps and minimum 4" end laps. Allowable roof coverings: Attachment of asphalt shingles shall be permitted in accordance with the FBC. TBP14001.3 FL12328-R7 Page 3 of 4 This evaluation report Is,provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any,product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GDEEK TAMKO BUILDING PRODCUTS, INC. j"� TAMKO Undedayments TECHNICAL SERVICES, LLC LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where, discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Minimum application temperature shall be 50OF unless otherwise noted. Contact the manufacturer when installing at temperatures below the minimum application temperature: 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 7) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 8) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 9) All undedayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 10) The underlayment maybe used as described in other current FBC product approval documents. 11) The underlayment shall not be installed over existing roof coverings. 12) Contact the manufacturer regarding specific exposure limits for each underlayment 13) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 5th Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer. IR,�P����. No 74021 � y � STATE OF .' 441� ,.off hill CERTIFICATION OF INDEPENDENCE 2016.08.2 2 09:35:39 Pp.a,.Ipepl.cM0.M., -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001.3 FL12328-R7 Page 4 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any ,product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.