EVALUATION REPORT
Tarco Roofing
One Information Way, Suite 225
Little Rock, AR 72202
EXTERIOR RESEARCH & DESIGN, LLC.
Certiftate oJAathorization #9sa3
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 4930.02.14-1112
FL16884-R2
Date of Issuance: 02/27/2014
Revision 2: 06/30/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaulated for compliance with the 5'h Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: LeakBarrier EasyLay UDL Synthetic Roof Underlayrnents
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provislons of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVEMUEMENr.. The Evaluation Report number preceded by the words 'TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:.
Robert J.M. Nieminen, P.E.
Florida Registration No. 59266, Florida DC4 ANE1983
The halmllo sail oppea ft wasaathorlsed by Robert Mammon,
PA an06/30/2015. fib does not serve asanelectronlalMs1ped
domment. signed fe/1eghardc4les have been transmitted to the
2-4— aww.,-mr and to the n211ted Cdent
LERriFICATION OF INDEPENDENCE:
1- TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest In any company manufacturing or
distributing products It evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither TrinitVIERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
CONTRACT®r, r., a ,
V TRINITYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: LeakBarrier EasyLay UDL Synthetic Roof Underlayments, as produced by Tarco Roofing, have
demonstrated compliance with the intent of the following sections of the Florida Building Code through testing in accordance
with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Umitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.3,1507.5.3,1507.7.3,
Unrolling, Breaking Strength, Pliability,
ASTM D226
2006
T1507.8,1507.8.3,1507.9.3,
Loss on Heating
1507.9.5
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
gntft
Examination
Reference
Data
ERD MlW49)
Physical Properties
SC4950.02.14
02/27/2014
UL, LLC (QUA9625)
Quality Control
Service Confirm,10227624
Exp. 02/20/2017
4. PRODUCT DESCRIPTION:
4.1 LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top surface. It Is
marketed as an alternate to ASTM D226, Type I or II felt.
4.2 LeakBarrier Easylay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top surface. It is
O'marketed as an alternate to ASTM D226, Type 11 felt.
D43LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top surface and a
rubberized polymeric coating on the back surface. It is marketed as an alternate to ASTM D226, Type 11 felt.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use In the HVHZ.
5.3 Fire Classification is not part of this report, refer to current Approved Roofing Materials Directory or test report from
accredited testing agency for fire ratings of this product.
5.4 LeakBarrier Easylay UDL Synthetic Roof Underlayments may be used .with any prepared roof cover where the
product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop LeakBarrier EasyLay UDL Synthetic Roo_ f��ments are as follows:
TABLE 1: ROOF COVER OPna
Underlayment
AsphaB
Shingles?
Nefl-On Tile
Foam -On
Meta
Wood Shakes &
Shingles
slate
Yes
No
No
Yes
Yes
Yes
Easylay UDL Basic
Yes
No
No
Yes
Yes
Yes
Easylay UDL 50
Yes
No
No
Yes
Yes
Yes
Exterior Research and Design, LLC.
Certykate of Aathorkadon 09503
Evaluation Report 4930.M.14-R2
FL16684-R2
Revision 2: 06/30/2015
Page 2 of 3
\,�TRINIT(I ERD
5.6 Exposure Limitations
5.6.1 LeakBarrier EasyLay UDL 15 shall not be left exposed for longer than 30-days after installation.
5.6.2 LeakBarrier EasyLay UDL Basic and LeakBarrier EasyLay UDL 50 shall not be left exposed for longer than 180-days
after installation.
6. INSTALLATION:
6.1 LeakBarrier EasyLay UDL Synthetic Roof Underlayments shall be installed in accordance with Tarco Roofing published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application.
6.1 LeakBarrier EasyLay UDL 15, UDL Basic or UDL 50:
6.1.1 Shall be installed in compliance .with the requirements for ASTM D226, Type I or II underlayment In FBC Sections 1507
for the type of prepared roof covering to be installed.
6.1.2 For slopes 4:12 (18.4') or greater: LeakBarrier EasyLay UDL 15 shall be laid horizontally, parallel to the eave with the
printed side up, flat and unwrinked and have minimum 4-inch side (horizontal) laps and minimum 8-inch end (vertical)
laps. Side (horizontal) laps shall run with the flow of water in a shingling manner. End (vertical) laps shall be offset
from course to course not less than 3 feet.
6.1:3 r slopes 2:12 (9.4') to < 4:12 (18.4'): LeakBarrier EasyLay UDL 15 shall be applied in a double coverage method,
fl t and unwrinkled. Begin by applying a 24-inch wide starter -strip along the eaves. Then place a full -width sheet over
e starter, with the lower edge flush to the starter's lower edge. Apply succeeding 48-inch wide courses up the roof
lope, overlapping each previous course a minimum of 20-inches in a "shingle fashion" with minimum 12-inch end
(vertical) laps. End (vertical) laps shall be offset from course to course not less than 3 feet.
6.1.4 Where laps or joints require sealant or adhesive use plastic cement recommended by Tarco Roofing. Tarco Roofing
recommends sealing all laps and joints where the underlayment will be exposed to wind -driven rain.
6.1.5 Attachment: Use corrosion -resistant or stainless steel roofing nails with 3/8-Inch diameter heads or low -profile plastic
cap -nails with 1-inch diameter heads spaced 9-inch o.c. at all laps and 12-inch o.c. at two (2) staggered rows in the
field of the sheet. If wind or rain is expected prior to finished roofing application, use 1-inch diameter plastic cap nails
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction In order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named CIA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (414) 248-6409; karen,buchroarin@ul:com
- END OF EVALUATION REPORT -