Loading...
HomeMy WebLinkAboutEVALUATION REPORTQOTRINITYIERD EVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR 72202 EXTERIOR RESEARCH & DESIGN, LLC. Certiftate oJAathorization #9sa3 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 4930.02.14-1112 FL16884-R2 Date of Issuance: 02/27/2014 Revision 2: 06/30/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaulated for compliance with the 5'h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: LeakBarrier EasyLay UDL Synthetic Roof Underlayrnents LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provislons of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVEMUEMENr.. The Evaluation Report number preceded by the words 'TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by:. Robert J.M. Nieminen, P.E. Florida Registration No. 59266, Florida DC4 ANE1983 The halmllo sail oppea ft wasaathorlsed by Robert Mammon, PA an06/30/2015. fib does not serve asanelectronlalMs1ped domment. signed fe/1eghardc4les have been transmitted to the 2-4— aww.,-mr and to the n211ted Cdent LERriFICATION OF INDEPENDENCE: 1- TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest In any company manufacturing or distributing products It evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither TrinitVIERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. CONTRACT®r, r., a , V TRINITYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: LeakBarrier EasyLay UDL Synthetic Roof Underlayments, as produced by Tarco Roofing, have demonstrated compliance with the intent of the following sections of the Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Umitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3,1507.5.3,1507.7.3, Unrolling, Breaking Strength, Pliability, ASTM D226 2006 T1507.8,1507.8.3,1507.9.3, Loss on Heating 1507.9.5 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: gntft Examination Reference Data ERD MlW49) Physical Properties SC4950.02.14 02/27/2014 UL, LLC (QUA9625) Quality Control Service Confirm,10227624 Exp. 02/20/2017 4. PRODUCT DESCRIPTION: 4.1 LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top surface. It Is marketed as an alternate to ASTM D226, Type I or II felt. 4.2 LeakBarrier Easylay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top surface. It is O'marketed as an alternate to ASTM D226, Type 11 felt. D43LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top surface and a rubberized polymeric coating on the back surface. It is marketed as an alternate to ASTM D226, Type 11 felt. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use In the HVHZ. 5.3 Fire Classification is not part of this report, refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 LeakBarrier Easylay UDL Synthetic Roof Underlayments may be used .with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop LeakBarrier EasyLay UDL Synthetic Roo_ f��ments are as follows: TABLE 1: ROOF COVER OPna Underlayment AsphaB Shingles? Nefl-On Tile Foam -On Meta Wood Shakes & Shingles slate Yes No No Yes Yes Yes Easylay UDL Basic Yes No No Yes Yes Yes Easylay UDL 50 Yes No No Yes Yes Yes Exterior Research and Design, LLC. Certykate of Aathorkadon 09503 Evaluation Report 4930.M.14-R2 FL16684-R2 Revision 2: 06/30/2015 Page 2 of 3 \,�TRINIT(I ERD 5.6 Exposure Limitations 5.6.1 LeakBarrier EasyLay UDL 15 shall not be left exposed for longer than 30-days after installation. 5.6.2 LeakBarrier EasyLay UDL Basic and LeakBarrier EasyLay UDL 50 shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6.1 LeakBarrier EasyLay UDL Synthetic Roof Underlayments shall be installed in accordance with Tarco Roofing published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.1 LeakBarrier EasyLay UDL 15, UDL Basic or UDL 50: 6.1.1 Shall be installed in compliance .with the requirements for ASTM D226, Type I or II underlayment In FBC Sections 1507 for the type of prepared roof covering to be installed. 6.1.2 For slopes 4:12 (18.4') or greater: LeakBarrier EasyLay UDL 15 shall be laid horizontally, parallel to the eave with the printed side up, flat and unwrinked and have minimum 4-inch side (horizontal) laps and minimum 8-inch end (vertical) laps. Side (horizontal) laps shall run with the flow of water in a shingling manner. End (vertical) laps shall be offset from course to course not less than 3 feet. 6.1:3 r slopes 2:12 (9.4') to < 4:12 (18.4'): LeakBarrier EasyLay UDL 15 shall be applied in a double coverage method, fl t and unwrinkled. Begin by applying a 24-inch wide starter -strip along the eaves. Then place a full -width sheet over e starter, with the lower edge flush to the starter's lower edge. Apply succeeding 48-inch wide courses up the roof lope, overlapping each previous course a minimum of 20-inches in a "shingle fashion" with minimum 12-inch end (vertical) laps. End (vertical) laps shall be offset from course to course not less than 3 feet. 6.1.4 Where laps or joints require sealant or adhesive use plastic cement recommended by Tarco Roofing. Tarco Roofing recommends sealing all laps and joints where the underlayment will be exposed to wind -driven rain. 6.1.5 Attachment: Use corrosion -resistant or stainless steel roofing nails with 3/8-Inch diameter heads or low -profile plastic cap -nails with 1-inch diameter heads spaced 9-inch o.c. at all laps and 12-inch o.c. at two (2) staggered rows in the field of the sheet. If wind or rain is expected prior to finished roofing application, use 1-inch diameter plastic cap nails 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction In order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named CIA entity for information on plants covered under Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (414) 248-6409; karen,buchroarin@ul:com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 4930.02.14-R2 Cerrilkate oJAuthorr:atfon k9503 FL16884-112 Revision 2: 06/30/202S Page 3 of 3