Loading...
HomeMy WebLinkAboutREVISION - 2-2-18(;Uvl OFFICE USE ONLY: DATE FILED: a Q. �� PERMIT # REVISION FEE: RECEIPT # 0 1. LOCATION/SITE ADDRESS: r3�04 7 / RECEIVED PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DMSION FEB 0 2 2018 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 ST. Lucie Count (772) 462-1553 FAX (772) 462-1578 y, Permitting APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: Flaj Rio-' to C_01A-(t n 7O 3. 4. 5. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: NAME: h@v w) mA L yh \ ADDRESS: CITY: - PHONE: 72- - a ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): Revised 07/22/2014 w�U a,SS6cla�la ST. LUCIE COUNTY CERT. #: STATE: FAX: STATE: FAX: STATE: FAX: Yh ri •, � ;,5 r ,•} •y y i ZIP: ZIP: ZIP: GENERAL NOTES�� 1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2014 FLORIDA BUILDING CODE, 5TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SE17 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: B 3. SCREENED ROOF ENCLOSURE FBC 2014 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 IL AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 % - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60 II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ALUMINUM SPECIFICATIONS: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE SPECIFIED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH BE PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK .." LLE SCREW AT 24" O.C. AND 6" FROM ENDS � �E D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" � L-- SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDSM MASONRY SPECIFICATIONS: gop mo 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD aria HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. rac 2. ALL MORTAR SHALL BE TYPE M OR S. � azz 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MR a.�- MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS: 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4101.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2?�ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. >t❑ FEB 0 2 2018 ST. Lucie County, cc - Z co o w O J =�W co o w Q Z v. ///Irlllllllll\\\\ FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. LEGEND: (ALL MAY NOT APPL SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW 09 X = HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW LIL- SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"x0.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"x0.044" 2 x 5: 2"x5"0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"4.044" 1 x 3: 1 "x3"x0.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"4.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7x0.057"x0.120" 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"4.092"4.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED IN INCHES. ILC C0 CMPcc1= WC)rcLU 0 cc EL CC v 0 o LU 40 a( _j w W. ,4C F C> ; 2 i1 rm LU .�xd�$" ; a����:� sr� LU = � z�Uj L � zj o p>W� ()e :C. W0w2 I)C,Ua J Q 9' T) _: 5 0 m �® �oor � w� toW Q m® U -I' J T_ _J m V z_ E w z_ 0 W Q 0 0 EL z J_ ILL 2 Q 2 L0 11, It O 00 a) cM M U w 0 U O0 LLI I• M F_ O U N O O Lq 00 0 E N � N 0 o ui N 00 r- 0 M w U U Y 2 _I �LL W it Z _j ui o C) W J Hm :D � m w F-�� Q2 U) Z cl w o a LU� 0 0NT0 m z U) O M a_W W F- a. 0 a CO zU 0 DESIGN DATE: 12/11/2017 Z REVISION 1: 01/26/2018 PAGE: REVISION 2: DATE /� SCALE: NTS I im THESE PLANS WERE PREPARED BASED ON 'REMISE THAT THE EXISTING STRUCTURE WAS DESIGNED BY A PROPERLY LICENSED PROFESSIONAL ENGINEER OF THE STATE OF FLORIDA, WAS PERMITTED BY THE APPROPRIATE PERMITTING AGENCY, WAS CONSTRUCTED BY A FLORIDA LICENSED CONTRACTOR AT THE TIME OF CONSTRUCTION, HAS NOT BEEN SUBJECT TO DAMAGE BY A MAJOR EVENT, AND HAS BEEN CERTIFIED BY THE CONTRACTOR THAT THE EXISTING STRUCTURE CURRENTLY SHOWS NO DEVIATIONS OR DEFECTS FROM THE STATE OF THE STRUCTURE AS PERMITTED BY THE FINAL INSPECTION OF THE PERMITTING AGENCY. ALSO, THE OWNER AND ALL PARTIES CONCERNED WILL INDEMNIFY FLORIDA ENGINEERING LLC FROM ANY DAMAGES OR CHANGES TO THE EXISTING STRUCTURE AS A RESULT OF ANY MODIFICATION OR FOR ANY OTHER REASON. O 1X2 2X2 DJ co 2X2 DJ L{� 2X4 S M B N ' x N N X 1 1X2 f 8'-6" RECEIVED MAR ST. Lucie County, Permitting 2X6SMB 11^^ L J N Lo N Co X Co X Co M 0 i 10'-0" w 4TH WALL CONSTRUCTION C --y op-� ALUMINUM FLASHING #8 SMS W/ 5/8" NEO- JTHRU-BOLT " N 0............. Gj co . \ �; i 4c, N LL 6 W Z •co o O �: Q = U :U � _ Q E Z ~ <C LLI FOR ALUMINUM PANS OR GALVALUME STEEL PANS USE #12 X 9/16" W/ 5/8" NEO-WASHER (3) PER PAN FOR COMPOSITE PANELS #12 X 1" LG. THAN PANEL THICKNESS SMS W/ 1-1/2" NEO-WASHER 12" O/C ADJACENT MOBILE HOME 4TH WALL ATTACHMENT - COL. PER PLAN ---- 1/2" CLEARANCE _; 3" X .024" X 1 LB 51 COMPOSITE PANELS - I 3105-1-114 01 1/4"-1' SLOPE (MIN.) (FL.# 7561.1-R4) I I I I I I —I------------------------ V-0" O/H 10'-011 -� 3X2X.050 THESE PLANS AND ALL PROPOSED W ARE SUBJECT TO ANY CORRECTIONS RLOUIRED BY FIELD INSPECTORS THAT - t►�AY BR NECEa9AR1� IN ORDER- TO "' EXISTING APPROVE It0M,4PLY. luvrrHuL. SIC ,A�e� 3" POLY ROOF _�-�i'�°v1lALL /ROOF TO C.B. CONNECTION SCALE: N.T.S. -------------- EXIE `Y) X U) WITH ACI coo N X X AND 3 pp cY) N N 2X2 (TYP. -------------- 1 X2 TYP. -------------- DING WALL RYLIC WINDOWS 6" KNEEWALL (2) 3/8" TAPCON (OR EQUAL) 3" MIN. EMBEDMENT THRU BOTTOM LEG OF ANGLE INTO CONC. SEE MFG. GUIDELINES FOR SET BACK REQ. TOP VIEW (2) 3/8" DIA. MACHINE BOLTS w/ WASHERS (2) 3/8" TAPCON (OR EQUAL)\ 3" MIN. EMBEDMENT THRU BOTTOM LEG OF ANGLE INTO CONC. COLUMN PER PLAN i .1/8"x2"x2"x2-1/2" (LENGTH) ANGLE (INTERNAL) CONC. FOOTING BELOW FRONT VIEW ALTERNATE 3" xY POST INTERNAL CONNECTION DETAIL SCALE: N.T.S. m c) (D Co00 co Z Z 0 O LL. LLI U 0 co a, ~ LLI � N Ur I-- M C f— �'E5) Z2Or-� W -.10 °' - Q Q H = U 0�(oF- OL-0 LL � ate. 00 O N O N M O w IQ 0 N W r O Cl) w U U N 0 M M z F- W O Y � = J Z_ LL � WU J Q ~ J � W UWU Z a Ow (n M a - DESIGN DATE: 12/11/2017 REVISION 1: 01/26/2018 PAGE: REVISION 2: 03/20/2018 n SCALE: NTS L (4) #10x3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TYP EACH SIDE) (B) 3/8" 0 CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE (TYP EACH SIDE) (SEE TABLE) ANCHOR SPA (MIN) (TYP) (SEE TABLE) COLUMN SIZE 3/8" 0 CONCRETE SCREW ANCHOR B MIN SPA 2X3 0 0 2X4 1 3 2X5 1 3 2X6 1 4 2X7 1 5 2X8 2 3 2X9 2 4 2X10 2 4.5 NOTES: PRIGHT 024 FLASHING SEALED TO ECONDARY ANGLE MIN WALL (TYP') .125" THICK (NOT EQUIRED FOR 2x3 EMBER) RIMARY 2"x2" m 0.125" ANGLE0 le ' V2x314" MS @ 12" O.C. TOP " MLUMN ) #10x3/4" SMS FASTENING �^ l M . ,,- q n 91; tA TO PRIMARY ANGLETYP EACH SIDE) .050-3" RECEIVING CHANNEL O "x2" BASE MEMBER (TYP EACH SIDE) --(1) 3/8" 0 CONCRETE SCREW ANCHOR INTO PRIMARY ANGLE AND @ 1/4" 0 CONCRETE �3" MIN. SCREW ANCHOR @ 24" O.C. BETWEEN COLUMNS (TYP EACH SIDE) 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2 3/4" AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTH AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED BY ENGINEER. 4.2X3 W/ 1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 5. IF FOR AN IN -FILL, TOP OF COLUMN CONNECTIONS SIMILAR IF CONCRETE LINTEL IF WOOD LINTEL SUBSTITUTE 1/4" OX3" LAG SCREW FOR 3/8" 0 LDT FOR BOTH PRIMARY & SECONDARY ANGLES. 6. 2X2X.045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO 2X3 MEMBER. 2"x3" OR LARGER UPRIGHT TO CONCRETE WM/O PAVER DETAILS SCALE:NTS HOST ROOF PER PLAN ALTERNATES FOR COL. TO 2"X2"AT HEADER: 1- DETAIL "C" SHT 3 2- (4) # 10 X 3" SMS THROUGH MEMBER ABOVE INTO COL SCREW BOSS 3- NOTCH COL. TO RECEIVE BEAM FASTEN W/ (2) Y." THRU-BOLT II CHAIR RAIL PER PLAN II 1/4"X2-3/4" TAPCONS -OR EQUAL AT 24" O.C. AND 6" FROM ENDS WHERE KICK PLATE IS INDICATED FASTEN W/#10 X 9/16" SMS 8" O/C AT PERIMETER EXISTING CONCRETE COL. PER PLAN 1 "X2" FASTEN TO' ADJOINING WALL W/#12 X 1-1/2" SMS @ 18" O.C. CONCRETE OR FILLED FASTEN TO MASONRY WALL MASONRY W/ 1/4' X 3" TAPCONS 18" O/C (INTERNAL) EXISTING RAFTER OR TRUSSER ram.\ 1 2" NOMINAL FASCIA MIN. - _- - -\\\1111111111//// THESE PLANS AND ALL PROPOSED K� � , 41 ARE SUBJECT MANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT ' 4-0 MAY BE IMES$ Rv IN .0RCE9l TO _ w C) ill LU J ~�12x3/4" SJdItS.@ 12" Qe PLY �I' H � L PLICA � �DE�, : (� o 0: o >� d b GBTTO y , z .040 X 3" U-HEADER (OR COMPOSITE O2 X 2POSI EPANELS: /1//jlllIIIIr0\0 \\\\ THROUGH RECEIVING FOR ALUMINUM PANS: CHANNEL @ 12" O.C. #12 X 2" SMS THROUGH "BOXED END": INTO WD FASCIA ALTERNATELY: (3) PER PAN (1) 1/4"x3" LAG BOLT THROUGH RECEIVING CHANNEL @ 12" O.C. [S�CA�LE.:NTS ANEL ATTACHMENT - MASONRY FRF PANEL ATTACHMENT -WOOD FRAME pyll LE:NTS Lh I ALUMINUM INTERNAL OR EXTERNAL FOR ALUMINUM PANS OR GALVALUME STEEL PANS RECEIVING CHANNEL w/(#10x75" USE #12 X 9116" W/ 5/8" NEO-WASHER (3) PER PAN INTO BEAM OR UPRIGHT 0.062 ANGLE I CLIPS MAYBE USED I FOR COMPOSITE PANELS #12 X 1" LG. THAN PANEL \ THICKNESS SMS W/ 1-1/2" NEO-WASHER 12" O/C l` PURLIN -MEMBER PLAN --- ROOF PER COVER END OF PANEL -------------- - i -- 2"X2" PER PLAN ATTACH TO ROOF PANELS W/# 12 X 2-1/2" SMS 12" O/C 6" FROM ENDS -CARRIER BEAM (2) 1/4" THRU-BOLT SEE ALSO COUEDGE BEAM ALTERNATES ADJOINING BEARING WALL 1" X 2" FASTEN TO ADJOINING WALL W/#12 X 1-1/2" SMS @ 18" O.C. WHERE SMB USED FOR COL. ATTACH PER DETAIL "B" .........................1....................... TYPICAL SIDE WALL 114" TAPCON (RED HEAD MFG. OR EQUAL) 6" FROM ENDS 24" O.C. COLUMN 1-1/2" PENETRATION INTO UNDERLYING FOOTING SCREEN ROOM END WALL SCALE: NTS BEAM PER PLAN (2) 1/4" THRU-BOLT - SEE ALSO COL/EDGE BEAM ALTERNATES F001.1 i ROOF TO CARRIER BEAM CONNECTION SCALE: NTS (2) 3/8" DIA EXPANSION BOLTS SEE NOTE #1 THIS PAGE FOR BOLT PLACEMENT 2" FROM EDGE ® 2" FROM EDGE OF SLAB' OF SLAB L____I ' TOP VIEW (2) 1/4" DIA MACHINE BOLTS w/ WASHERS 3"x3"x0.125" POST (2) 3/8" DIA. EXPANSION BOLTS SEE NOTE #1 THIS PAGE 3"x3"x0.125 ANGLE FOR BOLT PLACEMENT CONC. FOOTING - BELOW FRONT VIEW 3"x3" POST CONNECTION DETAIL SCALE: NTS #104" SMS INTO REW BOSSES UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS (4) 3/8"x4" TAPCON THRU BOTTOM LEG OF ANGLE INTO CONC. 1" 2" 33/4" FROM EDGE OF SLAB TOP VIEW (3) 1/4" DIA MACHINE COLUMN PER PLAN BOLTS w/ WASHERS 1/8"x2"x2"x3-3/4" (4) 3/8'W" LTD TAPCON (LENGTH) ANGLE (INTERNAL) THRU BOTTOM LEG I I OF ANGLE INTO CONC. CONC. FOOTING BELOW FRONT VIEW ALT. COLUMN BASE ATTACHMEN DETAIL SCALE: NTS m co J M ( co ZZ o O O U U J 0co— — WQ��� Z� r UI _ co c cm Z� O� W Q 0') Q _ Q U I l co F_ � J LL � Im N 00 t` 0 w 0 Q U N i O 'd• c'M co ti V_ 0 Z U W O ry 0- >Y � 2 J LL Z U-1 W U J 0 Q co J F-' Q I..._ Q_ W W o Z U O a =d M U) w (n 0_ 0 U d DESIGN DATE: 12/11/2017 REVISION 1: 01/26/2018 PAGE: REVISION 2: DATE SCALE: NTS