HomeMy WebLinkAboutLETTER - RESPONSE TO PLAN REVIEWArchitecto-hic Inc St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: 18700 Mach One Dr. Permit# 1712-0539 1-6 /0 hf) r20/ cal Please be advised that the following items are in response to plan review comments for the above referenced project dated 1/31/2018. 1. Missing documents -please provide two soil boring test reports with original signature by Engineer (A 107.2.1) Response. Removed from sheet #1 2. Missing documents -please product approvals for all doors (A) 107.2.1) Response. Owner to provide 3. Site plan -show toe of slope for fill/building pad. Fill can not go into the wetland easement. Slab height shown on site plan is higher than variance granted. See finished floor waiver from Planning & Developmental Services Department. Response., Owner to provide updated survey & foundation plan has been modified for grade change along wetlands 4. Certification for Design Load Compliance in conflict with Engineer's letter provided by USA Inc. Dated 10/25/17.(A 107.2.1) Response: Revised Design Load See Sheet # 1 5. Sheet A-1, Foundation Schedule -provide quantity of #5 Bars for F-3, F-4, F-5, F-6 (A 107.2.1) Response: Foundation schedule is ok. per phone conversation with Andrew 6. Please provide Electric Panel Schedule and Load Calculations Schedule for new building. (A 107.2.1 Response: See Revised Sheet #1 7. Please provide Circuit #'s on Floor Plan Electric Symbols. (A 107.2.1) Response: See Revised Sheet #1 8. Electric Riser shows service to residence, no residence is on property, revise as required, (A 107.1.2) Response: Revised to show future residence 9. Provide Plumbing Riser for Stub -Out. (A 107.2.1) Response: See Sheet #1 10. Clarify on Product Review Schedule 'Door' Design Pressure meets opening Design Pressure (A 107.2.1) Response: Corrected on Product Review 11.rs to a Concrete Anchor. Please clarify (A 107.2.1) aponser `Cbrre roduct Review PR J St R spe ui�y Su i d, .. CP AR9 8 I' i Mi ( .•� Arco' rD'�RG 806 Delaware Avenue Tel: 772 460 7751, www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 Arch itecto" ni C Inc St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: 18700 Mach One Dr. Permit# 1712-0539 Please be advised that the following items are in response to plan review comments for the above referenced project dated 211212018. 4) Certification for Design Load Compliance, in conflict with Engineer's Letter provided by USA Inc., dated 10/25/17. ([A] 107.2.1) Response: See Revised Sheet A-1 1.) Clarify Structural Design Data on the four submitted documents -A) Cover Letter from the MTL. Bldg. Design Engineer, USA Inc, B) Drawing L1 USA., C) Powerlift Door, Rice Engineering Sheet 01, D) Architectural Drawing A-1, Design Load Compliance Table. **Risk Category, Exposure, Adjustment Factors, Wind Speed, Floor and Roof Live/Dead Loads must match** Response: See Revised Sheet A-1 2) Door Documents- Engineer's original signature required, Architect needs to review and approve documents. Response: See Attached 3) Concrete required by Rice Engineering for Powerlift Door is 4,000 Psi, in conflict w/ specified by Architect. Response: See Attached 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax; 772 460 4244 FL Reg #AA26003348 1 of 1