HomeMy WebLinkAboutLETTER OF COMPLIANCEUNITED-,S DTURES OF AMERICA
'N C` 0. R '0' .0 R -A. T .E .p..-.
October 25, 2017
JAMIE BUSBY
18701 KITTY HAWK CT
FT PIERCE, FL 34987
UNITED STRUCTURES OF AMERi6A,.INC.
1912 BUSCHONG DRIVE
HOUSTON, TX 77039
P:(281)442-8247
www.usabidg.com .
RE`. U.S.A. Job # 50.022
'End Customer: JAMIE BUSBY
Jobsite: FT PIERCE, FL 34987
United Structures of America; Inc. certifies the above. referenced project design is in.accordance with the order documentatio n and the
applicable sections of the project specifications except as noted below. The following loads are applied in accordance with Florida
Building Code 2014.
BUILDING SIZE: 60'-0 x 60'-0 x 18'-6 1:12 Roof Slope
DEAD LOAD: Metal building structure only as furnished by U.S.A., Inc.
ROOF LIVE LOAD: 20. psf, with tributary reduction allowed
WIND DATA: Vult=153 mph Vasd=119 mph Risk Category=ll Exposure C
Internal Pressure Coefficient: +/-0.18.
Design Wind Pressure=45.08 psf
COLLATERAL LOAD: 3 psf
OTHER LOADS:
This letter applies to the referenced building(s) and its component parts as furnished by United Structures of America, Inc. Specifically
excluded are foundations, masonry and general contract work including erection certification.
The design and certification for this project is in accordance with the provisions and loads specified on the building order. The buyer is
responsible to insure all specified loads are in compliance with local regulatory authorities. .
This building and its structural components will be produced by an IAS AC472 accredited manufacturer
Sincerely,
Timothy D. Talbot, P.E. .
Design Engineer