Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE~ ~ ^oCr^~..�^~��. BY STlUCIE COUNTY Department of Community Affairs SN': 5050 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 600A-93 Residential Component Prescriptive Method A CENTRAL PROJECT NAME: |BUILDER: HARBOR COVE DELV AND ADDRESS: !PERMITTING !CLIMATE ST LUCIE CO |OFFICE: ST LUCIE CO QONE: 4|_| 51_1 61_1 R: HAHBOR COVE DELV !PERMIT NO. !JURISDICTION NO. _ ~ � . CK 1 ANew construction or addition 1. New Construction 24 Single family detached or Multifamily attached 2. Multi -Family 3. If Multifamily -No. of units 3. 4. If Multifamily, is this a worst case (yes/no) 4. Yes 5. Conditioned floor area (sq.ft.) 5. 3467.00 6. Predominant eave overhang (ft.) 6. 1.00 7. Porch overhang length (ft.) 7. 6.00 8. Glass area and type: Single Pane Double Pane a. Clear Glass 8a. 0.0sqft 0.00sqft b. Tint, film or solar screen 8b.480.0sqft 0.00sqft 9. Floor type and insulation: ' a. Slab on grade (R-value, perimeter) 9a.R= 0.00 , 132.00 ft 10.Net Wall type area and insulation: a. Exterior: 1. Concrete (Insulation R-value) 10a-1 R= 3.50, 580.00sqft____ a. Exterior: 2. Wood frame (Insulation R-value) 10a-2 R=11.00, 974.00sqft____ a. Adjacent: 2. Wood frame (Insulation R-value) 10a-2 R=11.00, 261.00sqft____ a. Adjacent: 2. Wood frame (Insulation R-9alue) 10a-2 R=19.00, 430.00sqft____ 11.Ceiling type area and insulation: a. Under attic (Insulation R-value) 11a.R=19.00 , 1534.00sqft____ 12.Air distribution systems a. Ducts (Insulation + Location) 12a. R= 6.00 , uncond 13.Cooling system 13. Type: Central A/C EER: 10.00 14.Heating System: 14. Type: Strip Heat COP: 1.00 15.Hot water system: 15. Type: Electric EF: 0.94 16.Hot Water Credits: (HR-Heat Recovery, 16. ' DHP-Dedicated Heat Pump) 17.Infiltration practice: 1, 2 or 3 17.' 2 18.HVAC Credits (CF-Ceiling Fan, CV -Cross vent, 18. CF MZ HF-Whole house fan, RB-Attic radiant barrier, NZ-Multizone) 19.EPI (must not exceed 100 points) 19. 98.92 a. Total As_Built points 19a. 57209.21 b. Total Base points 19b. 57835.44 . j _______________________________ reby certify that the plans and ifications covered by this calcu- �afibn are in compliance with the FloridaC PREPA DATE: I hereby cert this building is in compliance i e Florida Energy Code. �x----T/ Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this budding will be inspected for compliance in accordance with Section 553.908 F.S. OWNER/AGENT: DATE: ' BUILDING OFFICIAL: DATE: Department of Community Affairs SN: 5050 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 600A-93 Residential Component Prescriptive Method A CENTRAL PROJECT NAME: |BUILDER: HARBOR COVE DELV AND ADDRESS: |PERMITTING |CLIMATE ST LUCIE CO |OFFICE: ST LUCIE CO 1ZONE: 41_1 51_1 61_1 OWNER: HAHBOR COVE DELV !PERMIT NO. !JURISDICTION NO. CK ~1. New construction or addition 2. Single family detached or Multifamily attached Z. If Multifamily -No. of units 4. If Multifamily, is this a worst case (yes/no) 5. Conditioned floor area (sq.ft.) 6. Predominant eave overhang (ft.) 7. Porch overhang length (ft.) S. Glass area and type: a. Clear Glass b. Tint, film or solar screen 9. Floor type and insulation: a. Slab on grade (R-value, perimeter) 10.Net Wall type area and insulation: a. Exterior: 1. Concrete (Insulation R-value) a. Exterior: 2. Wood frame (Insulation R-value) a. Adjacent: 2. Wood frame (Insulation R-value) a. Adjacent: 2. Wood frame (Insulation R-value) 11.Ceiling type area and insulation: a. Under attic (Insulation R-value) 12.Air distribution systems a. Ducts (Insulation + Location) 13.Cooling system 14.Heating System: 15.Hot water system: 16.Hot Water Credits: (HR-Heat Recovery, DHP-Dedicated Heat Pump) 17.Infiltration practice: 1, 2 or 3 18.HVAC Credits (CF-Ceiling Fan, CV -Cross vent, HF-Whole house fan, RB-Attic radiant barrier, MZ-Multizone) 19.EPI (must not exceed 100 points) a. Total As_Built points b. Total Base points I Hereby certify that the plans and specifications covered by this calcu- lation are in compliance with the Frorida En PREPARED BY 0 AT 1. New Construction 2. Multi -Family 3. k 4. Yes 5. 3467.00 6. 1.00 7. 6.00 Single Pane 8a. 0.0sqft 8b.960.0sqft Double Pane 0.00sqft _ 0.00sqft _ 9a.R= 0.00 , 132.00 ft 10a-1 R= 3.50, 580.00sqft____ 10a-2 R=11.00, 974.00sqft____ 10a-2 R=11.00, 261.00sqft____ 10a-2 R=19.00, 430.00sqft____ 11a.R=19.00 , 1534.00sqft 12a. R= 6.00 , uncond IS. Type: Central A/C EER: 10.00 14. Type: Strip Heat COP: 1.00 15. Type: Electric EF: 0.94 16. 17. 2 is. CF MZ 19. 98.92 19a. 57209.21 19b. 57835.44 Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance in accordance with Section 553.908 F.S. I hereby certify that this building is | in compliance with the Florida Energy | Code. { | OWNER/AGENT: 1 BUILDING OFFICIAL: DATE: - '-+ DATE: ''p,^'). ** INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST ** =============================================================================== COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK =============================================================================== PJACTICE #1 606.1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. Windows 606.1 _______________________________________________ � Maximum of 0.34 CFM per linear foot of operable sash ^ crack (includes sliding glass doors). _______________________________________________________________________________ Exterior & 606.1 Maximum of 0.5 CFM per sq. ft. of door area: solid Adjacent Doors _________________________________________________________-_____________________ core, wood pahel,insulated or glass doors only. Exterior Joints 606.1 To be caulked, gasketed, weather-stripped or other- & Cracks wise sealed. PRACTICE #2 606.1 COMPLY WITH PRACTICE #1 AND THE FOLLOWING: _______________________________________________________________________________ Exterior Walls 606.1 Top plate penetrations sealed. Infiltration barrier & Floors installed. Sole plate/floor joint caulked or sealed. _______________________________________________________________________________ Exterior Walls 606.1 Penetrations, joints and cracks on interior surface & Ceilings' _______________________________________________________________________________ caulked, sealed or gasketed. DuctWork 606.1 Ductwork in unconditioned space must be sealed. _______________________________________________________________________________ Fireplaces 606.1 Equipped with outside combustion air, doors and flue --------------------------------------------------------------------------------- dampers. Exhaust Fans 606.1 Equipped with dampers. Combustion devices see 606.1.A.2. _______________________________________________________________________________ Combustion 606.1 Be in unconditioned space (except direct vent), draw Appliances air from unconditioned space, exhaust to outside. Cooking appliances shall be dampered and use intermittent ignition. ------------------------------------------ ** OTHER PRESCRIPTIVE _____________________________________ MEASURES (must be met or exceeded by all residences.) ** _______________________________________________________________________________ Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built- _______________________________________________________________________________ in heat trap required. Swimming Pools 612.1 Spas and heated pools must have covers (except solar & Spas heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal » _______________________________________________________________________________ efficiency of 78 percent. Shower Heads 612.1 Water flow must be restricted to no more than 3 gal - ---------------------------------------------- Ions per minute at 80 PSIG. � _--------------------------------- HVAC Duct 610.1 All ducts, fittings, mechanical equipment and plenum Construction chambers shall be mechanically attached, sealed, ins - Insulation & ulated and installed in accordance with the criteria Installation of Section 610.1.ABC.2 & 610.1.ABC.3. Duct in attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in mechanical closet. _______________________________________________________________________________ HVAC Controls 607.1 Separate readily accessible manual or automatic ---------------- ��� thermostat for each system. wm".^ mA,/u,u^,` n-A7. wuxo/u/// wwzi= - rr=mw n-zi ur, 602.1 _______________________________________________________________________________ CBS R-3 both sides. Common ceiling & floors R-11. ******************************************************************************* SUMMER CALCULATIONS ******************************************************************************* ' === BASE === =============================================================================== | === AS -BUILT === GLASS---------------- | ORIEN AREA x BSPM = POINTS | TYPE. SC ORIEN AREA x SPM x SOF = POINTS _______________________________________________________________________________ ,N133.00 82.2 10932,6 1 SGL TINT N 26.0 51.5 .92 1236.0 | SGL TINT N 26.0 51.5 ,92 1236.0 1 SGL TINT N 52.0 51.5 .92 2472.0 ^ | SGL TINT N 29.0 51.5 .71 1061.5 NE 13.00 82.2 1068.6 1 SGL TINT NE 13.0 76.6 .92 919.2 E 119.00 82.2 9781.8 1 SGL TINT E 24.0 107.1 .93 2398.4 | SGL TINT E 26.0 107.1 .93 2598.2 | SGL TINT E 69.0 107.1 .93 6895.3 W 202.00 82.2 16604.4 1 SGL TINT W 96.0 107.1 .93 9593.5 � | SGL TINT W 53.0 107.1 .93 5296.4 | SGL TINT W 53.0 107.1 .95 5378.3 NW 13.00 82.2 1068.6 { SGL TINT NW 13.0 76.6 .88 878.1 ------------------------------------------------------------------------------- ./5 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS | GLASS ' AREA __________________________________________________________________________�__ AREA FACTOR POINTS POINTS \ POINTS / .15 3,467.00 =============================================================================== 480.00 1.083 39,456.00 42,748.11 1 39,963.10 NON GLASS------------ | AREA x BSPM = POINTS | TYPE R-VALUE AREA x SPM = POINTS _______________________________________________________________________________ WALLS---------------- � Ext 1554.0 1.0 1554.0 | Ext Wood Frame 11.0 974.0 1.90 1850.6 1 Ext NormWtBlock In 3.5 580.0 1.30 754.0 Adj 691.0 .7 483.7 | Adj Wood Frame 11.0 261.0 .70 182.7 | Adj Wood Frame 19.0 430.0 .30 129.0 DOORS---------------- | i Ext 20.0 4.8 96.0 | Ext Insulated 20.0 4.80 96.0 Adj 18.0 1.6 28.8 | Adj Wood 18.0 2.40 43.2 CEILINGS------------- | � UA 1534.0 .6 920.4 | Under Attic* 19.0 1534.0 1.10 1687.4 FLOORS--------------- | | Slb 132.0 -31.8 -4197.6 | Slab -on -Grade .0 132.0 -31.90 -4210.8 INFILTRATION--------- | | 3467.0 10.9 37790.3 1 Practice #2 3467.0 10.90 37790.3 TOTAL SUMMER POINTS / . 79,423.71 1 78,285.49 TOTAL x SYSTEM = COOLING ( TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING SUM PTS MULT POINTS | COMPON RATIO MULT MULT MULT POINTS _______________________________________________________________________ 79,423.71 .37 29,386.77 1 78,285.49 1.00 1.100 .340 .817 23,920.76 ******************************************************************************* ' WINTER CALCULATIONS ******************************************************************************* === BASE AS -BUILT === =============================================================================== GLASS---------------- i ORIEN AREA x BWPM = POINTS | TYPE SC ORIEN AREA x WPM x WOF = POINTS ____________________________________________________________________-________ N 133.00 -3.4 -452.2 | SGL TINT N 26.0 9.6 1.04 259.9 | SGL TINT ' N 26.0 9.6 1.04 259.9 | SGL TINT N 52.0 9.6 1.04 519.8 | SGL TINT N 29.0 9.6 1.19 330.2 NE 13.00 -3.4 -44.2 | SGL TINT NE 13.0 7.3 1.09 103.1 E 119.00 -3.4 -404.6 | SGL TINT E 24.0 -2.0 .63 -30.3 | SGL TINT E 26.0 -2.0 .63 -32.8 | SGL TINT E 69.0 -2.0 .63 -87.1 W 202.00 -3.4 -686.8 | SGL TINT W 96.0 -2.0 .63 -121.2 | SGL TINT W 53.0 -2.0 .63 -66.9 1 SGL TINT W 53.0 -2.0 .70 -74.0 NW 13.00 -3.4 _______________________________________________________________________________ -44.2 | SGL TINT ' NW 13.0 7.3 1.12 106.6 .15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS | GLASS AREA _______________________________________________________________________________ AREA FACTOR POINTS POINTS | POINTS .15 3,467.00 =============================================================================== 480.00 1.083 -1,632.00 -1,768.17 1 1,167.35 NON GLASS------------ | AREA x BWPM _______________________________________________________________________________ = POINTS | TYPE R-VALUE AREA x WPM = POINTS WALLS---------------- | Ext 1554.0 1.1 1709.4 | Ext Wood Frame 11.0 974.0 2.00 1948.0 1 Ext NormWtBlock In 3.5 580.0 3.58 2073.5 Adj 691.0 1.8 1243.8 | Adj Wood Frame 11.0 261.0 1.80 469.8 | Adj Wood Frame 19.0 430.0 1.00 430.0 DOORS---------------- � | Ext 20.0 5.1 102.0 | Ext Insulated 20.0 5.10 102.0 Adj 18.0 4.0 72.0 1 Adj Wood 18.0 5.90 106.2 CEILINGS------------- | � UA 1534.0 .6 920.4 | Under Attic 19.0 1534.0 1.00 1534.0 � FLOORS--------------- | � Sib 132.0 -1.9 -250.8 | Slab -on -Grade .0 132.0 2.50 330.0 INFILTRATION--------- | | ' 3467.0 4.1 =============================================================================== 14214.7 1 Practice #2 3467.0 4.10 14214.7 TOTAL WINTER POINTS | " 16,243.33 1 22,375.55 =============================================================================== TOTAL x SYSTEM = HEATING | TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING WIN PTS MULT _______________________________________________________________________________ POINTS | COMPON RATIO MULT MULT MULT POINTS 16,243.33 1.10 17,867.66 =============================================================================== | 22,375.55 1.00 1.100 1.000 .950 23,382.45 w ***************** * 36^86 = IcB * ***************** =============================================================================== ^ T3^603 _______________________________________________________________________________ 19 0^9066 9^38223 8^03623 1 Vt^W8^ 19 0^T8901 L^19811 8^98263 SlNIO6 = SlNIO6 + SlNIO6 + SlNIO6 1 SlNIO6 = SlNIO6 + SlNIO6 + SlNIO6 =101 =============================================================================== 831VM lOH 8NIlV3H SNI1003 | IV101 831UM lOH 8NIlV3H 8NI1003 3SV8 === ******************************************************************************* A8VWWOS =============================================================================== 00^906^6 00^T 0^3022 000^T M^ 0v | 00^l8O0l 0^/7Qr r ° lmW 0I1V8 | SW8O38 wlO1 = 1IOmJ » mOW « ANVl M aWOiOA ANVl | It/101 = l-lOW : jO WON =============================================================================== === mIO8—Su 3Su8 === ******************************************************************************* 8NIlUM 831VM ******************************************************************************* ENERGY GUIDE For detailed information Df the EPI rating number or for any ITEM listed, askyour Builder for EPI= 98.9 ]CA Form 600A-93 zr Form 600B-93 - ~ 0 10 20 30 40 50 60 70 80 90 100 |____ -----------------------------------X-| [he maximum allowable EPI is 100. The lower the EPI the more efficient the home RESIDENTIAL ENERGY PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency � SINGL CLR DBL TINT !NSULATION.................. Ceiling R-Value......... 19.0 Wall R-Value......... 10.6 Floor R-Value......... 0.0 IR CONDITIONER............. SEER/EER � .................. 10.3 EATING SYSTEM.............. Electric COP/HSPF........ 1.0 Gas AFUE............ 0.00 ATER HEATER................ Electric EF.............. 0.94 Gas EF........... ... 0.00 Solar EF............... JHER FEATURES.............. R-10 R-30 1---------X----------- | R-0 R-7 |-------------------- X! R-0 R-19 |X-------------------- 1 10.0 SEER 17.0 |X-------------------- 1 9.7 EER 16.0 2.50 COP 4.19 |X--------------------| 0.78 AFUE 0.90 1--------------------- 1 0.88 0.96 |--------------- X----- | 0.54 0.90 i--------------------- | 0.40 0.80 |---------------------| certify that these energy saving features required for the Florida iergy Code have been installed in this house. Builder jdress : S ignature: ate: ity/Zip lorida Energy Code for Building Construction - 1993 iorida Department of Community Affairs FL-EPL CARD93 ENERGY GUIDE or ditailed information f the EPI rating number r for qny ITEM listed, sk your Builder for. EPI= 98.9 :A Form 600A-93 ^ Form 600B-93 0 10 20 30 40 50 60 70 80 90 100 � |---------------------------------------X-i lemamimum allowable EPI is 100. The lower the EPI the more efficient the home , RESIDENTIAL ENERGY PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency SINGL CLR DBL TINT [NDOWS..d.................. Single Tint |------ X-------------- i � JSULATION.................. .Ceiling R-Value......... 19.0 Wall R-Value......... 10.6 Floor Walue......... 0.0 :R CONDITIONER............. SEER/EER.................. 10.3 ZATING SYSTEM Electric COP/HSPF........ 1.0 Gas AFUE............ 0.00 KER HEATER................ Electric EF.............. 0.94 Gas EF.............. 0.00 Solar EF.............. [HER FEATURES.............. R-10 R-30 |--------- X----------- | R-0 R-7 1-------------------- X| R-0 R-19 �X--------------------� 10.0 SEER 17.0 |X--------------------| 9.7 EER 16.0 2.50 COP 4.19 |X--------------------: 0.78 AFUE 0.90 |---------------------| 0.88 0.96 |--------------- X----- | 0"54 0.90 |--------------------- i 0.40 O.80 |--------------------- | ` ` ce?tify that these energy saving features required for the Florida iergy Code have been installed in this house. Builder |dress:Signature-. ate: ty/Zip .orida Energy Code for Building Construction - 1993 ,orida Department of Community Affairs FL-EPL CARD93 .