Loading...
HomeMy WebLinkAbout92-01930 BUILDING PLAN CHECKBUILDING PLAN CHECKNNED my ST. LUCIE COUNTY -FORT PIERCE PTF Y%iWvON BUREAU FORT PIERCE, FLORIDA TELEPHONE 465-6655 e JURISDICTION: St. Lucie County PROJECT NAME: HARCOUR COVE BUILDING N CONTRACTOR: Harbour Cove Development Inc. ARCHITECT: Marvin Gelatt OWNER: Blue Ridge Harbour Cove Inc. LOCATION: Harbour Cove Dr. BUILDING SIZE: 774o sg. ft. OCCUPANCY TYPE: Residential R-2 ',,CONSTRUCTION TYPE: SBCCI. VI NFPA. V (000) 'PLAN NUMBER #6175 ' BUILDING DEPT. NO.91-2745 PHONE NUMBER 464-3266 PHONE NUMBER 461-0300 DATE RECEIVED 12-13-91 12-16-91 NUMBER OF STORIES 2 BUILDING HEIGHT ;FIRE PROTECTION: Automatic Sprinkler Yes No Occupancy Hazard N.F.P.A. #13 Requirements: 1. Page 2 of the plans under Door Schedule: Door B is shown as a two (2) hour rated solid core. A one (1) hour listed and labeled Class B door and jamb assembly is all that is required. This door shall be equipped with a self -closing device. 2. Smoke detectors, First Floor: They are shown to be contiguous to the kitchen area. With their present location a number of false alarms will be experienced, due to cooking smoke. We suggest.they be moved to a different location in the living room or corridor leading to the garage. -REVIEWED BY CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU. ON ALL INSPECTIONS 24 HOUR NOTICE REQUIRED ON ALL INSPECTIONS DATE / 2 'Z9 Z Sheet No. _L of