Loading...
HomeMy WebLinkAbout92-01930 ENERGY EFFICIENCY CODE��. ` 1738 . ° � FLORIDA ENERGY EFFICIENCY � �M CODE ��0AN'"^~=, FOR BUILDING CONSTRUCTION BY Section 9 Compliance Program ~ Residential Point-S\stem Method � Version 1.0 January, 1991 � Department Of Community Affairs - Printout generated by EPI91 and submitted in lieu of Form 900-A-91 THIS COMPLIANCE FORM IS VALID IF SUBMITTED w---------------------------------------------------- AFTER JANUARY 1, 1991 -------------------------- ,ROJECT NAME: HARBOR COVE | PERMITTING OFFICE: ------------------------------ � | �� \ �-~ )ND ADDRESS: WORST CASE FACE EAST ,�L | ---- -----------z------ --- | CLIMATE ZONE: 4 5 ------------------------------ BUILDER: �- y-~ � �� i -------------- } PERMIT NO. : f-�����-`^�- lWNER: ------------------------------ --�-��---�------_ � -------------- | JURISDICTION NO.: | 7 ------------- ------------------------------------------------------------------------------- !OMPONENTN DIMENSION: VALUE: RATING: VALUE: OFFICIAL CHECKLIST 3TRUCTURE TYPE: ' Multi -Family # of units 0 WORST CASE REP. DREDOMINANT EVE OVERHANG Length: 2.00 ________ ________ DORCH OVERHANG Length: .00 VINDOWS S4ngle Tint Total Area 330.00 All Vertical Glass Total Area 330.00 All Skylight Glass Total Area .00 VALLS Adj Wood Frame Area: 556.00 R-Val: 19.00 Ext NormWtBlock Int Area: 1372.00 R-Val: 3.70 )OORS Ext Insulated Area: 20.00 Adj Insulated Area: 18.00 DEILINGS FLAT Under Attic Area: 1267.00 R-Val: 19.00 ________ ________ rLOORS Ilab-on-Grade Perimeter: 83.00 R-Val: .00 )U TS Unconditioned Space Length ALL R-Val: 6.70 DOOLING Central A/C SEER: 9.00 Multizone: Credit fEATING Strip Heat STRIP: 1.00 Multizone: Credit fOT WATER Electric EF: .94 Bedrooms: 3.00 LNFILTRATION Conditioned Floor Area: 2167.00 Pract: 2.00 AS BUILT POINTS / BASE POINTS * 100 = EPI 44,232.60 44,801.25 98.73 c/ nno ^oc^ ,k v****************************************************************************** WATER HEATING ******************************************************************************* * === BASE === | === AS -BUILT === =============================================================================== qUM. OF x MULT = TOTAL | TANK VOLUME EF TANK x MULT x CREDIT = TOTAL 3EDRMS | RATIO MULT � ------------------------------------------------------------------------------- Y3 3527.0 10,581.00 | 50 .94 1.000 3302.0 1.00 9,906.00 = = = ====================================== ^****************************************************************************** SUMMARY ^****************************************************************************** === BASE === | === AS -BUILT === =============================================================================== lOOLING HEATING HOT WATER TOTAL | COOLING HEATING HOT WATER TOTAL OOINTS + POINTS + POINTS = POINTS | POINTS + POINTS + POINTS = POINTS 22445.9 11774.3 10581.0 44,801.25 1 18367.3 15959.3 9906.0 44,232.60 ============================================================================== ***************** * EPI = 98.73 * ***************** ^****************************************************************************** , SUMMER CALCULATIONS ******************************************************************************* m === BASE === | === AS -BUILT === =============================================================================== iLASS---------------- | ' ]RIEN AREA x BSPM = POINTS | TYPE SC ORIEN AREA x SPM x SOF = POINTS ------------------------------------------------------------------------------- N/ 56.00 47.8 2676.8 | SGL TINT N 56.0 51.5 .83 2389.9 E ' 242.00 102.0 24684.0 / SGL TINT E 28.0 107.1 .78 2331.1 1 SGL TINT E 106.0 107.1 .84 9511.0 | SGL TINT E 64.0 107.1 .78 5328.3 1 SGL TINT E 16.0 107.1 .78 1332.1 1 SGL TINT E 28.0 107.1 .78 2331.1 S 32.00 90.9 2908.8 1 SGL TINT S 32.0 98.3 .67 2097.2 ------------------------------------------------------------------------------- ,15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS / GLASS AREA AREA FACTOR POINTS POINTS } POINTS -------------------------------------------------- .15 2,167.00 330.00 ----------------------------- .985 30,269.60 29,815.56 | 25,320.66 =============================================================================== VON GLASS------------ � AREA x BSPM = ------------------------------------------------------------------------------- ` POINTS | TYPE R-VALUE AREA x SPM = POINTS 4ALLS---------------- / Ext 1372.0 1.0 1372.0 | Ext NormWtBlock In 3.7 1372.0 1.26 1728.7 )dj 556.0 .7 389.2 | Adj Wood Frame 19.0 556.0 .30 166.8 )OORS---------------- i | .20.0 4.8 96.0 Ext Insulated 20.0 4.80 96.0 )dj 18.0 1.6 28.8 | Adj Insulated 18.0 1.60 28.8 VEILINGS------------- | i ]A 1267.0 .6 760.2 | | Under Attic 19.0 1267.0 1.10 1393.7 TLOORS--------------- | 31b 83.0 -31.8 -2639.4 | Slab -on -Grade .0 83.0 -31.90 -2647.7 [NFILTRATION--------- | | 2167.0 10.9 23620.3 1 Practice 42 2167.0 10.90 23620.3 =============================================================================== DOTAL SUMMER POINTS | 53,442.66 1 49,707.28 =============================================================================== MAL x SYSTEM = COOLING | TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING 3UM PTS MULT POINTS | COMPON RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 53,442.66 .42 22,445.91 =============================================================================== | 49,707.28 1.00 1.090 .377 .900 18,367.34 ^****************************************************************************** WINTER CALCULATIONS ******************************************************************************* m === BASE === ( === AS -BUILT === =============================================================================== KASS---------------- i ]RIEN AREA x BWPM = ----------------------------------------------------------------------------- POINTS | TYPE SC ORIEN AREA x WPM x WOF = POINTS -- Nj 56.00 5.6 313.6 | SGL TINT N 56.0 9.6 1.10 591.9 E. 242.00 -5.6 -1355.2 | SGL TINT E 28.0 -2.0 -.21 12.0 | SGL TINT E 106.0 -2.0 .12 -25.8 | SGL TINT E 64.0 -2.0 -.21 27.5 1 SGL TINT E 16.0 -2.0 -.21 6.9 | SGL TINT E 28.0 -2.0 -.21 12.0 S 32.00 -14.0 -448.0 | SGL TINT S 32.0 -10.2 .69 -226.8 ------------------------------------------------------------------------------- .15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS | GLASS AREA ------------------------------------------------------------------------------- AREA FACTOR POINTS POINTS | POINTS .15 2,167.00 330.00 .985 -1,489.60 -1,467.26 | 397.74 ION GLASS------------ � AREA x BWPM = ---------------------------------------------------------------------------- POINTS | TYPE R-VALUE AREA x WPM = POINTS 4ALLS---------------- | Ext 1372.0 1.1 1509.2 | Ext NormWtBlock In 3.7 1372.0 3,48 4781.4 ;d' 556.0 1.8 1000.8 | | Adj Wood Frame 19.0 556.0 1.00 556.0 )OORS---------------- � Ext 20.0 5.1 102.0 1 Ext Insulated 20.0 5.10 102.0 4d' 18.0 4.0 72.0 | Adj Insulated 18.0 4.00 72.0 ]EILINGS------------- � | ]A 1267.0 .6 760.2 | � Under Attic 19.0 1267.0 1.00 1267.0 :LOORS--------------- | 31b 83.0 -1.9 -157.7 | Slab -on -Grade .0 83.0 2.50 207.5 [NFILTRATION--------- | | 2167.0 4.1 8884.7 ( Practice 42 2167.0 4.10 8884.7 =============================================================================== [QTAL WINTER POINTS | 10,703.94 1 16,268.36 =============================================================================== [OTAL x SYSTEM = HEATING 1 TOTAL x CAP x DUCT x SYSTEM x CREDIT'= HEATING VIN PTS MULT POINTS | COMPON RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 10,703.94 1.10 11,774.34 =============================================================================== | 16,268.36 1.00 1.090 1.000 .900 15,959.26 ------------------------------------------------------------------------------- rn Accordance with Sec. 553.907 F• o So , 1 Review of the plans and specifications ! hereby certify thatthe plans and 1 covered by this calculation indicates specifications covered by i_•hi.0 itc!lci_a-• 1 compliance With the Florida Energy/ la ion are in compliance with 'h•I"e 1 Code. e Bpi='I'or"e i__or"Istructi!=n is coff pl!='tecl :::L or" id: Energy Code. 1 this building will be inspected for :iWI41E.Ft/f ►_iENT 1 BUILDING OF'F ICI AL_s