Loading...
HomeMy WebLinkAboutOSTDS NEWA S'CANNEP �� t STATE OF FLORIDA BY PERMIT #= 56-SF-2447698 DEPARTMENT OF HEALTH ST LUCIE 001INTVAPPLICATION #: AP1786502 ONSITE SEWAGE TREATMENT AND DISPOSAL DATE PAID: SYSTEM FEE PAID CONSTRUCTION PERMIT RECEIPT #: CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: Joseph Baer PROPERTY ADDRESS: 771 Campbell Rd Fort Pierce, FL 34945 LOT: BLOCK: SUBDIVISION: PROPERTY ID #: 2309-341-0004-000-0 DOCUMENT # : PR1736525 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM- DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 900 ] GALLONS / GPD Septic new CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @E ]DOSES PER 24 HRS #Pumps [ ] i D E = 500 ],'SQUARE FEET Drainfield new SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ l STANDARD [ ] FILLED [x] MOUND I CONFIGURATION: [ J TRENCH [x] BED [ ] W F LOCATION OF BENCHMARK: 20d nail in SE fence post, N of system I I ELEVATION OF PROPOSED SYSTEM SITE [ 16.001E INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 8.00 ][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D FILL, REQUIRED: [26.00] INCHES EXCAVATION REQUIRED: [ 54.001 INCHES 0 T H E R system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 9pd. SPECIFICATIONS BY: Brian J Ingram TITLE: Environmental Specialist III APPROVED BY: r TITLE: Environmental Specialist III _ Brian J In am DATE ISSUED: 02/15/2022 EXPIRATION DATE: DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC v 1.1.4 AP1786502 SE1653005 St Lucie CHD 08/15/2023 ; Page 1 of 3' iS_• STATE OF FLORIDA DEPARTMENT OF -HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT NO. 8 DATE PAID: /I ig.12S FEE PAID: RECEIPT # ; [f ] New System [ 7 Existing System [ ] Holding Tank .[ ] Innovative [ ] Repair j j Abandonment [ ] Temporary [ ] APPLICANT: �,Jy C, �' L-i);"14M DrAC1C AGENT: MAILING ADDRESS: -77 96-L 1 TELEPHONE: -7 742 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.I05(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: BLOCK: SUBDIVISION: PLATTER: PROPERTY ID #: ZONING: ��r f I/M OR EQUIVALENT. [ Y0 ] PROPERTY SIZE.: j.0 ACRES WATER SUPPLY: [✓] PRIVATE PUBLIC [ ]<=2000GPD [ 1>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ Y j�S� 1� PROPERTY ADDRESS: "' �i f � &C — DIRECTIONS TO PROPERTY: ] DISTANCE TO SEWER': T r i (.Li f Lj BUILDING INFORMATION [ RESIDENTIAL [ ] COMMERCIAL FT Init Type of -No. of Building Commercial/Institutional System Design Jo Establishment Bedrooms Area Sgft_ Table I, Chapte= 64E-6:1 FAC 2 3 4 ] aims [ 7 Other (Specify) ,f ---��- IGNAT[3RE : t f : r'L- g �.�-'�''- DATE:- STATE OF FLORIDA APPLICATION # AP1786602 DEPARTMENT OF HEALTH PERMIT # 56-SF-2447698 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT # SE1653005 SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Joseph Baer CONTRACTOR / AGENT: ACCURATE SEPTIC SERVICES LOT: BLOCK: SUBDIVISION: ID# : 2309-341-0004-000-0 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: (X]YES [ ]NO NET USABLE AREA AVAILABLE: 3.04 ACRES TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 4559.99 GALLONS PER DAY [ 1500 GPD/ACRE I OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 2000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF PROPOSED SYSTEM SITE 20d nail in SE fence post, N of system 16.00 ( INCHES / FT ] ( ABOVE / BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 100 FT NON -POTABLE: FT BUILDING FOUNDATIONS: 10 FT PROPERTY LINES: 27.7 FT POTABLE WATER LINES: 62 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [XINO 10 YEAR FLOODING? ( ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD ."r,+,* - -1 SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES: Munsell #lColor Texture Depth 10YR 411 Loamy Sand 0 To 5 10YR 511 Sand 5 To 26 10YR 6/1 Sand 16 To 26 10YR 4/3 Sandy Clay 26 To 54 10YR 4/3 Sand 54 To 72 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 611 Sand 0 To 22 1 OYR 7/1 Sand 17 To 22 10YR 414 Sandy Clay Loam 22 To 54 10YR 4/2 Loamy Sand 54 To 72 OBSERVED WATER TABLE: 59.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: ( PERCHED / APPANT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 16 INCHES [ ABOVE / BELOW I EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [XINO MOTTLING: [XIYES [ ]NO DEPTH: 16.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DRAINFIELD CONFIGURATION: [ ] TRENCH [X I BED i- REMARKS/ADDITIONAL CRITERIA Sand/0.60 DEPTH OF EXCAVATION: 54 INCHES [ ] OTHER (SPECIFY) WSWT determined using USDA WSS and soil borings. 10YR611 stripping in IDYR511 matrix>10% with diffuse boundaries starting at 16" in SB1. S131 1B" below BM. S8215" below BM. _ SITE EVALUATED BY: Ingram, Brig tie: Environmental Specialist 111) (ENVIRONMENTAL HEALTH) DH 4015, 08/09 (Obsoletes previous editions hich may not be used) Incorporated: 64E-6.001, FAC DATE: 02/11/2022 Page 3 of 4