HomeMy WebLinkAboutENERGY EFFICIENCY CODE.' Who n.
SCANNED
BY Wy
r E FLORIDA ENERGY EFF I C I E L 0' U
FOR BUILDING CONSTRUCTION
Section 9.Gompliance Program - Residential Point System Method
Version 3.0 September, 1989
;f Department Of Community Affairs
Printout generated by EPI89C and submitted in :Lieu of Form 900-A--89
THIS COMPLIANCE FORM IS VALID IF SUBMITTED BEFORE ,JANUARY 1, 1990
PROJECT NAME:
1 PERMITTING OFFICE:
AND ADDRESS:
1
1 CLIMATE ZONE:: 4 `,
------------------------------
BU I LDER :
V I
:
: PERMIT
____--------____....---
NO.:
OWNER-.
)A� S�
JURISDICTION NO . :
e V : ---___---.-------
COMPONENT": DIMENSION:
VALUE:
RATING:
VALUE: OFFICIAL CHECKLIST
STRUCTURE TYPE:
Single -Family
PREDOMINANT EVE OVERHANG Length:
2.00
PORCH OVERHANG Length:
12.00
WINDOWS
Single Tint Total Area
152.00
All Vertical Glass Total Area
152.00
All Skylight Glass Total. Area
.0()
WALLS
Ad j Wood Frame Area:
206.00 0
R-Val :
1. � . calf
Ext Wood Frame Area:
1004.60
R-Val:
13.00
DOORS
Ext Insulated Area:
20.00
-...__
Ad j Wood Area:
13.00
CEILINGS
FLAT- Under Attic: Area:
1234.00
R--Val:
19.00
FLOOI:.S
Slab -on -Grade Perimeter:
115.00
R-Val:
.00 _
DUCTS
Unconditioned Space Length ALL
R-Val.:
4.20
COOLING
Central. A/C
SEC:R2
9.00
Ceiling Fang Credit
HEATING
Strip Heat
STRIP:
1.0o
NOT WATER
Electric
EK
..Be
Bedrooms:
3.00
INFILTRATION
Conditioned Floor Area:
1234..00
Pract:
2.00
AS BUILT- POINTS / BASE POINTS
100 - EP I
2B,323.32 20,517.68
99.32
GLASS TO FLOOR
AREA RATIO
-
.1232
In Accordance with Sec. 553.907 F.S., | Review of the plans and specifications
I Hereby certify that the plans and | covered by this calculation indicates
specifications covered by this calcu- | compliance with the Florida Energy
lation are in compliance with the | Code. Before construction is completed
Florida | this building will be inspected for
| compliance in accordance'with Section
� - - | 553.908 F.S.
' |
DATE 1 DATE
v
• f 4, . It !
♦ V,
'�"�'•�"�"i'F'%f R'SE' �f. �'.�.'Y£".#"#'.�C'#.'}f"#' I.C'�'7�.'�"�"�"�i"�'F'�"�"#'?JS.'!ff"#'.T�'7K.'�L"�.L �. �"#"YS'ii"�• i�•-1�'7'�"�L7�.'�"1�''•�C'�2"}{"�["Y"'*"�'�"�'3�. �'�"iF' �"}�.'�"��"�'.1i�"�.t"�.{"�"#"�{' I:"�"�"`�"j!'
SUMMER CALCULATIONS
--- LASE ___
-- AS --BUILT
GLASS -_.-___------_---_
OFF I EN AREA x BSPM =
POINTS
1
TYPE SC OR I EN AREA
x SF• M
x SOf=
= POINTS
--------------------------------------------------------------------------------
N 18.70 47.8
893.9
1
SG1._ TINT N 18.7
51.5
.80
769. 8
E 9.90 102.0
1009.8
1
SGL TINT E 9.9
107.1
.64
683.5
S 64.70 90.9
5881. 2
1
SGL_ TINT S 18.7
98.3
. 59
1090.5
1
SGL TINT S 14.0
98.3
.59
816.4
1
SGL TINT S 32.0
98.3
.59
1866.1
W 58.70 � 102.0
5987.4
1
SOL TINT W 40.0
107.1
.33
1424.9
1
SGL TINT W 18.7
107.1
.72
1439.2
-------------------------------------------------------------------------------
. 1.5 x COND. FLOOR / TOTAL
GLASS
- ADJ. x GLASS -
ADJ GLASS
1
GLASS
AREA
AREA
FACTOR POINTS
POINTS
1
POINTS
-------------------------------------------------------------------------------
. 15 1,234.00
152.00
1.218 13,772.29
16,771.39
1
8,090.37
NON GLASS ---_-_-_-_.-_--
1
AREA .. BSPM =
POINTS
1
TYPE_ R-•VALUE
AREA
x SPM
= POINTS
WALLS ----------------
Ext 1.004.6 1.0
1004.6
1
Ext Wood Frame 13.0
1004.6
1.70
1.707.8
Ad j 206.0 .7
144.2
1
Ad j Wood Frame 13.0
206.0
.60
123.6
DOORS _----•------•-------
1
Ext 20.0 4.8
96.0
1
Ex t Insulated
20.0
4.80
96. ci
Ad i 18.0 1.6
28.8
1
Ad j Wood
18.0
2.40
43.2
CEILINGS -------------
1
UA 1234.0 .6
740.4
1
1
Under Attic 19.0
1234.0
1.10
1357.4
FLOORS --.--__----------
i
Slb 1.75.0 -31..8
-5565.0
1
Slab -on -Grade .0
175.0
- 31..90
--5582.5
INFILTRATION------•---
12•=4.0 10.9
13450.6
1
Practice *2
1234.0
10.90
1.3450.6
TOTAL_ SUMMER POINTS
1
26,
670. 99
1
'19v 206. 49
TOTAL x SYSTEM -
COOLING
1
TOTAL x CAP x DUCT x SYSTEM
x CREDIT
r COOLING
SUM PTS MULT
POINTS
1
COMPON RATIO MULT
MULT
MULT
POINTS
-------------------------------------------------------------------------------
26 9 67t i . 99 .43 11,468.52
1
19,2e6.49 1.00 1.140
.380
.660
19 185. 22
•Di-##•#•#ai•�r•Yi••s�'#-r'�••)E••Di•##�'r#'k•�'•'s'i' "x#•3i••� #3i• �•#'�,•#•�•#'!r#'�••�##•#4•#####•ir##•3'r#°.4'##•.'�###3i•#•#c'•##•3F####i'F••?d•3i•#"r�'•i�••3�••t�'#•3E••i4•##
WINTER CALCULATIONS
###�F•##••3F•x•# ##'#•#•?F•##'�'###4F#
•3F#•#•�#######•�••#4'##•'s;-•k•?4•###4Q••3i'##•#•###'#•#3@•'#•##•�•#•�•h###•3i'•i�##•�§''A'-•#r##•M••3{
##•:i•##
=- - BASE
AS
-BUILT --
GLASS --------_.---__-----
OR I EN AREA x 1 WPM =
POINTS
1
TYPE SC OR I EN
AREA x WPM
x WOF
= POINTS
-------------------------------------------------------------------------------
N 18.70 5.6
104.7
1
SOL TINT N
18.7 9.6
1.12
201.6
E 9.90 -5. 6
--55. 4
1
SOL 'TINT E
9.9 -2. 0
--1. 02
20.2
S 64.70 --14. 0
-905. 8
1
SOL TINT S
18.7 --• 1 0. 2
.58
-1. 10. 1
1
SOL TINT S
14.0--10.2
.58
--82.4
1
SGL TINT S
32.0 --10.2
.58
-188.4
W 58.70 --5.6
_ 28. 7
1
SOL TINT W
40.0 -2. 0
-4.03
322.4
1
SOL TINT W
1.8.7 -2.0
--.55
20.4
.1.5 x COND. FLOOR / TOTAL
GLASS
= ADJ. x GLASS
- ADJ GLASS
1
GLASS
AREA
AREA
FACTOR POINTS
POINTS
1
POINTS
-------------------------------------------------------------------------------
. 15 1,234.00
152.00
1.218 -1, 185 . '24
"-1, 4.4 . •34
1
133.64
NON GLASS ----_--__------
1
AREA x BWPM =
POINTS
1
TYPE R-VALUE
AREA
x WPM
= POINTS
-------------------------------------------------------------------------------
WALLS-------.---_-------
1
Ex•L- '1004.6 1.1
1105.1
1
Ext Wood Frame
13.0 1004.6
1..80
1808.3
Ad j 206.0 1.3
370.8
1
Ad j Wood Frame
13.0 206.0
1.60
329.6
DOORS-_ -----__---------
1
Ex t; 20.0 5.1
102.0
1
Ex t: Insulated
20.0
5.10
102.0
Ad j 13.0 4.0
72.0
1
Ad j Wood
18.0
5.90
106.2
CEILINGS-------------
1
UA 1234.0 .6
740.4
1
Under Attic
19.0 1234.0 0
1.00
1234.0
FLOORS ---------------
Slb 175.0 -1.9
-332. 5
1
Slab -on -Grade
.0 175.0
2.50
4: �7.5
INFILTRATION ---------
1
1234.0 4.1.
5059.4
1
Practice 42
1234.0
4.10
5059.4
TOTAL WINTER POINTS
1
5,673.S2
1
9,260.62
TOTAL x SYSTEM =
HEATING
1
TOTAL_ x CAP x DUCT
x SYSTEM x CREDIT
=
HEATING
WIN PTS MULT
POINTS
1
COMPON RATIO MULT
MULT
MULT
POINTS
-------------------------------------------------------------------------------
5, 67. . 82 1.14 6,468.15
1
9,260.62 1.00 1.140
1.000 1.000
1c1,
557. 10
� a t
cam:' Z, �8 --C)"IB!:,O1:T "1...gr;ca1. - --z"SST!- I C39 "l..TE4 az o"Tm-"OT Z"891-/9 9"89VTT
S.I..NT0al =- S_I.NiOJ + S.L.NTOd + S.LNTOrd 1 SJ_NTOd = S.I_NTOd SIN T.OJ 4- S_I.IVTOJ
3114101 ; •I-Ilvm 10I-1 JI\I:[ J_V3H 9N.T. -fOOO 1-IV.LOI J31VM J-OH 91q 1 J-V31 I 91\11-I003
_L-iina.-•SV
•K• n•i:•#•#•# n^#•� ##}'#•}`�'s'F'#h•# h #•fi'3:••i.°•�'if•'�•'k' 7i•3'c''fi•if#'•�:•'.r#•Yt•# n••3f••n'•A•#�''k'fr•�###•K •�f•##3'r##'n'•�i••Yc•#### r•'k'•'�•fi••#••'�'#'#if##??•##•'�'##
AJVIAII�mS
#####'�F•#•K'•k'•A•##'ht##•&•#'•Y:•�•###•## n #•�••�•###••3:••'�:••��••#•i'f'#$:••#••#•st• # # k''r�•�•#3r# n°3••D£•+-#s''•#'k#'k••�i'###• # �' n?�'k'####•#####}'f•
CS(:)"TEar'OT i 0"T C)"Z r:a.: 000T SS" 0 1 00"TSr6OT ci",r_zr'L-:
J_-IF)w 01 IVI•J 1 sw--jCL-_I,3
`IV_LQ..L = J.iamn x .I_`Inw %c ::-INV.L d3 3wn'ioA ::INV.L 1-1VJ_O.L. = L-inw ..10 wnN
-] i i"iS -SV =- - 1 -__ ISVs3 == -
•�• #• # #• •�..n. i;• # # # # ## 3x•3Q•# #,k..;� •:%' •t,� # ;;.'� d;•-'r£• i'f-h'•?F• •'.�.• #i• # # #'k #.;:• :�';�• •�{ ,�•.�• #'f. #•�. shc.p{. gc x,+5. x..�s••'k' •�• •j':• # •�{•.ri .p.# 3:• :%• :.£•# ##�' �. x..;�.,,�. x. sc,�. # •H• •:: •3E•
.ft JNTJ.V.-:IM•i J-]J.VM
#•###3r•'�•3F##s`E'#fi•#•3#•##i#•�•'k••'�- f-''k••."i'# ,C•rF• A i;.•3•:�•3#••fi•'..'-#�''�'�#• N••iF'#•##3f••h•'.4••1=9#•'v:•##'r�•####•�•#•#�•'.�•##°,:•#r}�.••'k3r#3E••#•##3.°####i#•
s� �