FBC ENERGY CONSERVATION CODE R402.4.1.2
House Infiltration Test (Blower Door) Certificati ,n
Prescriptive and Performance Method '
Permit #: l7%G(- e0k/aY
Contractor: Hortw
Job Address: SH7 I c�eu+a+�,c G�� rt- Peale r= / 3Lf9`iS
RECEIVED
SFP 2 6 Ci8
wde County,
Construction: (' Q New Construction - Complete ( ) Existing -After Addition
House Infiltration Test Results SLC Climate Zone 2 Q/�Y�,g
CFM (50) = 119 Test Date:
Volume = 1 Y ,716
ACH (50) = CFM (50) x 60 / Volume = !' g�i Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less (x) Pass ( ) Fail
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1; 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2 inches w.=g..(50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as'set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in
accordance with Section M1507.3.
Testing Company
Company Name:
ISpo re3Pncr S wave plv�
Address: 'Sgc,([.s0n%ijj e �/ :;2225
I hereby certifyphe above ouse Infiltration results demonstrate compliance with FBC Energy Conservation
require me nts,,ffi accordance ith Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name:
License/Certification #:
�S
,1�
A ' Planning & Development Services ,
W Building & Code Regulation Division
2300 Virginia Ave, Rm 201 - - -- --
iJ = — Fort Pierce, FL 34982 RECEIVED
Q 772-462-2165 Fax 772-462-6443
+1
-• = FBC ENERGY CONSERVATION CODE S E P 5 w, 3
Duct Sealing Certification ST. Lucie County, Permittfri
Prescriptive and Performance Method
Date: ` 1 ' U .. Permit #:�0� [��� Lot #:
Contractor: 1O&W Address: 5I 4 2 Tj e"Jei C;r Pi: Pierce Pt
3k9�tS
Construction: Post Construction Test ❑ Rough -in Test
Test Conditions: o p
Date: / '2 Y �O Floor Area (ft2): 1 v 7.2,
Time: i Primary Location of Supply Ductwork C
Indoor Temperature (F): Primary Location of Return Ductwork +hL
Outdoor Temperature (F):
Total Leakage Test (Outside)
Duct Leakage: ❑ Default ❑ Prop. Leak Free ❑ Proposed On = 3
Test Pressure: --25 (Pa)
Baseline Duct Pressure (optional) (Pa)
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: xPass ❑ Fail
Installed Pa
Total Leakage (cfm): • 03
Total Leakage per 100 sgft: 3
a
CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgft.
Testing Company
Company Name:
I hereby c that
9s2110!! Q�y Syyw �i�d
Address: 3g61G�wyd � % L 3.292S
Duct Sealing Leakage results demonstrate compliance with 5th Edition FBC Energy Conservation requirements in accordance with
Printed N e. !'�`PS / ' ' C°y License/Certificate#: 6?1\jW ow Ir,