Field Density Tests of Compacted Soils Method D-6938
Project: Proposed Residence Lot 4, Creekside Date: June 7, 2018
Address: 3147 Tidewater Circle, Fort Pierce, Fl- . Order #: 18DR472
Area Tested: Building Pad Permit #: %/Z — ®�Sz/
Material Type: Very Pale Brown Sand Tech: BK
Client: . D.R. Horton, Inc.
Address: 1430 Culver Drive NE Compaction Req.:
Palm Bay, FL 32907
Proctor Method:
95%
ASTM D-1557
Test
#
TEST LOCATION
Probe.
Depth
Elev.
Moist
%
Dry
Density
PCF
Proctor
Value
PCF
Optimum
Moisture
%
Compaction
Pass
1
Center of Building Pad
12"'
FL
13.1
101.0
104.0
14.0
97.1%
Yes
2
NW Corner of Building Pad
12"
FL
13.8
103.8
104.0
14.0
99.8%
Yes
3
SE Corner of Building Pad
12"
FL
11.0
102.0
104.0
14.0
98.1 %
Yes
4
5
6
7
8 .1
LGE1
E
10
11
BY:
12
13
14jOMN
4
Remarks: See Reverse Side Page 2 of 2 for Additional Information for Disclaimer �� ; - �,t,C E NgF•�� �j/
This is a Compaction Test only on the top 12" of the pad and is not a verification of Sou Egi
Legend for.Elevation: /1
PR = Proofroll 1,2,3 =1st, 2nd, 3rd Lift Submitted by: —
SL = Spillngline . FL = Final Lift Keith LeBlanc, P.E. ; 7 1�� . ATf;,QF.
SG = Subgrade BG = Below Grade Federal Engineering 'r 1�ac `/
BC = Basecourse 'BOF = Bottom of Footing Florida Reg. No. 59394// S LbR10�'��C�,���`
TOP = Top of Pipe FG = Finished Grade Certificate of AuthorizatiotfoSpEbfi9Jt#')'h
QNAL
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization M E0ments,
conclusions or extracts from or regarding our reports Is reservedpending our written approval. A density test determines the degree of compaction of the tested layer of material
only. A density does not replace a soil bearing capacity determination. These density tests do not certify the underlying soil materials below the proposed structure. The results
do not prelude or guarantee that future settlement and cracking will not occur. A soli boring test is required to certify that the underlying soils will support the proposed structure
without settlement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be performed to evaluate the suitability of the underlying
soil to support the proposed structure. After laying dormant for a period of 9D days or after heavy rain/stones, retesting must be performed on this work.
PAGE 1 of 2 APPRul" c r'
r
e e d
& TESTING INC.
250 SW 13th Ave Pampano'Beach, FL 33069
Field.Density Tests of Compacted Soils Method D-6938
Phone 954-784-2941
_ 800-848-1919
Fax 954-784-7875
www.fed-eng.com
Project: Proposed Residence Lot 4, Creekside Date: June 7, 2018
Address: 3147 Tidewater Circle, Fort Pierce, FL Order #: 18DR472
Area Tested: Building Pad Permit #: PUZ,- d�
Material Type: Very Pale Brown Sand Tech: BK
Client: D.R. Horton, Inc.
Address: 1430 Culver Drive NE Compaction Req.: 95%
Palm Bay, FL 32907 Proctor Method: ASTM D-1557
Test
#
TEST LOCATION
Probe
Depth
. Elev.
Moist
,�o
Dry
Density
PCF
Proctor
Value
PCF
Optimum
Moisture
/o
Compaction
Pass
1
Center of Building Pad
12"
FL
13.1
101.0
104.0
14.0
97.1 %
Yes
2 '
NW Corner of Building Pad
12"
FL
13.8
103.8
104.0
14.0
99.8%
Yes
3
SE Corner of Building Pad
12"
FL
11.0
102.0'
104.0
14.0
98.1 %
Yes
4
5
7
8
9
10
12
13
14
a
'
Remarks: ' See Reverse Side (Page 2 of 2) for Additional Information for Disclaimer
This is a Compaction Test only on the top 12" of the pad and is not a verification of SoiyBear ng Ca0acity.
Legend for Elevation: /
PR = Proofroll 1,2,3 = 1st, 2nd, 3rd Lift Submitted by: f _
SL = Springline FL = Final Lift Keith LeBlanc,4.P.E.
SG = Subgrade BG = Below Grade Federal, Engineering &x Testing,: Inc.
BC = Basecourse BOF = Bottom of Footing Florida Reg. No. 59394 '
TOP = Top of Pipe FG = Finished Grade Certificate of Authorization'45471
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and.authorizatlon for publication of.staeements,
conclusions or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degreel6f:compktion of.th�e t stcd layer of material
only. A density does not replace a soil bearing capacity determination. These density tests do not certify the underlying soil materlals'-below the -proposed stry iu e: The results
do not preclude or guarantee that future settlement and cracking will not occur. A soil boring test is required to certify that the underlying sons wi:; support°?lig�•aroposed structure
without settlement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be performed t6Fi9aluafel t ie `sr itabWty`of the underlying
soil to support theproposed structure. After laying dormant for period of 90 days or after heavy rain/storms, retesting must be performed on this wo►k:
PP Y 9 P Y vY 9
PAGE 1 of 2
Com
Pursuant to your request, Federal Engine,
project on the reverse side. The purpose
material only. In no way shall a compactic
performed by the client prior to constructioi
12" of added fill material. FET was not cor
added fill material does not include an anal
the proposed structure without settlement.
conditions below the tested top 12 inches c
structure, we recommend performing soil b(
soil conditions.
Environmental analysis of the soil mat(
required, we can provide a proposal for
for determination of the degree of comp;
d Soils Method 13-6938 Disclaimer
-ing & Testing, Inc. (FET) has performed a compaction test at the referenced
)f our test was to determine the degree of compaction of the tested layer of
i test replace a soil bearing capacity determination. A soil boring test must be
to verify subsoil conditions. Our scope of services only included testing the top
racted to perform supervision of the building pad preparation. This testing of the
sis of the underlying soil materials to determine if they are capable of supporting
This density compaction test does not warranty any underlying soil materials or
material. If no soil borings have been performed in the location of the proposed
ings below all foundation areas of the proposed structure to verify the underlying
is not part of the scope of services. If environmental analysis of the soils is
rming an environmental analysis of the soil_ materials. The scope of services is
of the tested layer of material only. No other analysis is implied or warranted.
Job project specifications were not available'at the time the work was performed. Determination of the pass/fail compaction
results are based on current common industry requirements of 95% of the ASTM D-1557 standard for building foundations
and 98%(of the AASHTO T-180 standard .for paved areas such as roadways and parking lots. If different specifications are
required, Federal Engineering & Testing, Inc. ,shall be notified.
Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on other
areas or dates. Any subsequent site disturbances due to water erosion, rain waters, construction activities, excavations,
overgrown, vegetation, traffic and other disturbances will'void this test and the site must be re -compacted and re -tested prior
to construction.
As a mutual protection to clients, the public alnd ourselves, all reports are submitted are the confidential property of clients
and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved
pending written approval.
It has been a pleasure working with you and we look forward to doing so in the near future.
Page 2 of 2