FBC-ENERGY CONSERVATION CODE R402.4.1.2 RECEIVED
House Infiltration Test (Blower Door) Certification SEP 2 ,0 2010
Prescriptive and Performance Method Permitting Department
St. Lucie County
/ 7 f; - 06e
Construction: (X) New Construction — Complete ' ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) _ 0 3 Test Date: q 2/%
Volume = �`j
ACH (50) = CFM (50) x 60 / Volume = y' v 6 Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less Pass ( ) Fail
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower -door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to the code officipl. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in
accordance with Section M1507.3.
Testing Company 615-%0 Rmylryc'Y sp 81 u4
Company Name: k e�eC. Address: Jcc,Ici ny►) I M 3 --42 R S
I hereby certi at the a ve House Infiltration results demonstrate compliance with FBC Energy Conservation
require Itsn accord ce with Section R402.4.1.2 Climate Zone 2.
Sign
Printed Na e: V oln es M c6y
License/Certification #: dq V ("6 0yy )`
Planning & Development Services
Building & Code Regulation Division
40 May 2300 Virginia Ave, Rm 201 RECEIVED
Fort Pierce, FIL 34982
r- 772-4 2-2165 Fax 772-4 2-6443
` ® , SEP 2 01010
-- -�- FBC ENERGY CONSERVATION CODE Permitting Department
Duct Sealing Certification St. Lucie County
1 Prescriptive and Performance Method
Date: �I �'� !� Permit #: l R - (9 60- Lot #: 131
Contractor: 1/� +-/ i7 Address: 8�10 y "")"p dr
Construction: irPost Construction Test ❑ Rough -in Test
Test Conditions: Va
�pDate: � �v Floor Area (ft2): 1 O2 o
Time: q: Y 5 4 m Primary Location of Supply Ductwork C*
Indoor Temperature (F): Primary Location of Return Ductwork .�• j-�C
Outdoor Temperature (F):
Total Leakage Test (Outside) CdY
Duct Leakage: ❑ Default ❑ Prop. Leak Free ❑ Proposed On = 1
Test Pressure: (Pa)
Baseline Duct Pressure (optional) (Pa)
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: p(Pass ❑ Fail
Installed Pa
Total Leakage (cfm):
Total Leakage per 100 sgft: /
CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft.
Testing Company 9S70 At ft c oitickre 914
Company Name: G Address: JQGICSt'�►7 of I (— 122-25
I hereb rtify that the ove Duct Sealing Leakage results demonstrate compliance with 51h Edition FBC Energy Conservation requirements in accordance with
Sec' n R403.2.2.
Signature:
Printed e: CI M e S )"n `Cay License/Certificate #: