Loading...
HomeMy WebLinkAboutFBC ENERGY CONSERVATION CODEDate: Contractor: Job Addres! t � Planning & Development Services; Buila ng & Code Regulation Division 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC-ENERGY CONSERVATION CODE R402.4.1.2 RECEIVED House Infiltration Test (Blower Door) Certification SEP 2 ,0 2010 Prescriptive and Performance Method Permitting Department St. Lucie County / 7 f; - 06e Construction: (X) New Construction — Complete ' ( ) Existing — After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) _ 0 3 Test Date: q 2/% Volume = �`j ACH (50) = CFM (50) x 60 / Volume = y' v 6 Mechanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less Pass ( ) Fail FBC, Energy R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting shall be conducted with a blower -door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code officipl. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company 615-%0 Rmylryc'Y sp 81 u4 Company Name: k e�eC. Address: Jcc,Ici ny►) I M 3 --42 R S I hereby certi at the a ve House Infiltration results demonstrate compliance with FBC Energy Conservation require Itsn accord ce with Section R402.4.1.2 Climate Zone 2. Sign Printed Na e: V oln es M c6y License/Certification #: dq V ("6 0yy )` Planning & Development Services Building & Code Regulation Division 40 May 2300 Virginia Ave, Rm 201 RECEIVED Fort Pierce, FIL 34982 r- 772-4 2-2165 Fax 772-4 2-6443 ` ® , SEP 2 01010 -- -�- FBC ENERGY CONSERVATION CODE Permitting Department Duct Sealing Certification St. Lucie County 1 Prescriptive and Performance Method Date: �I �'� !� Permit #: l R - (9 60- Lot #: 131 Contractor: 1/� +-/ i7 Address: 8�10 y "")"p dr Construction: irPost Construction Test ❑ Rough -in Test Test Conditions: Va �pDate: � �v Floor Area (ft2): 1 O2 o Time: q: Y 5 4 m Primary Location of Supply Ductwork C* Indoor Temperature (F): Primary Location of Return Ductwork .�• j-�C Outdoor Temperature (F): Total Leakage Test (Outside) CdY Duct Leakage: ❑ Default ❑ Prop. Leak Free ❑ Proposed On = 1 Test Pressure: (Pa) Baseline Duct Pressure (optional) (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: p(Pass ❑ Fail Installed Pa Total Leakage (cfm): Total Leakage per 100 sgft: / CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft. Testing Company 9S70 At ft c oitickre 914 Company Name: G Address: JQGICSt'�►7 of I (— 122-25 I hereb rtify that the ove Duct Sealing Leakage results demonstrate compliance with 51h Edition FBC Energy Conservation requirements in accordance with Sec' n R403.2.2. Signature: Printed e: CI M e S )"n `Cay License/Certificate #: