HomeMy WebLinkAbout1307-0126 PROJECT INFORMATIONWrightsoft
Cooler By Design
Project Summary
Entire House
Project Information
Job: 2585
Date: July 03, 2013
For: Bruce Bryant, Advantage Air Cond
5402 Echo Pines Circle West, Fort Pierce, FL 340'
Email: 2shawnrussell@bellsouth.net q '
Notes: y
Design Information
Weather:
Winter Design Conditions
Outside db
43
OF
Inside db
70
OF
Design TD
27
OF
Heating Summary
Structure
23269
Btuh
Ducts
4764
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
28034
Btuh
Infiltration
Fort Pierce, FL, US
Method Simplified
Construction quality Semi -loose
Fireplaces 0
Heating Cooling
Area
14
Volume (fP)
12672 12672
Air changes/hour
0.70 0.36
Equiv. AVF (cfm)
148 76
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.2 kW
27823 Btuh
19 OF
1317 cfm
0.047 cfm/Btuh
0 in H2O
Summer Design Conditions
Outside db
90 OF
Inside db
75 OF
Design TD
15 OF
Daily range
L
Relative humidity
50 %
Moisture difference
61 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
22893
Btuh
Ducts
9880
Btuh
Central vent (0 cfm)
0
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
31134
Btuh
Latent Cooling Equipment Load Sizing
Structure
3176
Btuh
Ducts
2043
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
5220
Btuh
Equipment total load
36354
Btuh
Req. total capacity at 0.70 SHR
3.7
ton
Cooling Equipment Summary
Make Rheem
Trade RHEEM RASL SERIES
Cond RASL-039JEC
Coil RHPN-HM3624++RCSN-H'3624
AHRI ref 3763847
Efficiency 13,5 EER, 19.5 SEER
Sensible cooling
27650
Btuh
Latent cooling
11850
Btuh
Total cooling
39500
Btuh
Actual airflow
1317
cfm
Air flow factor
0.040
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.86
BoWfalic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
rf' wrtghtsoft Right-Sufle® U nHer.12012121,06 RSU09070 2013Ju1-0317:13116
+K-C:A Page 1
-C;WaeB45haWfilDocumenteWC LOAUS11000 SO FT.rup CaIc=MJ6 Front fbor faces: NE