HomeMy WebLinkAbout1206-0265 EVALUATION REPORTSCANNED BY 3T LUCID COUNTY (. EXTERIOR RESEARCH & DESIGN, LLC. I, Certificate of Authorization #9503 ° TRi�11T�` ERD 353 CHRISTIAN OXFORD, CT 16478 PHONE: (203) 262-9245 FAX:(203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12 One Owens Corning Parkway FL10674-R6 Toledo, OH 43659 Date of Issuance: 02/06/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADvERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/06/2012 This does not serve as an electronically signed document. Signed, sealed hardcuples have been transmitted to the Product Approval Administrator and to the named Ghent CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. TRUTY 1 RD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL(TST1740) Physical Properties 06CA20263 04/18/2006 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05 10/13/2011 UL (QUA1743) Quality Control Service Confirmation Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic& and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration®, Duration® Premium, Oakridge° and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard® HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 2 of 6 TRINITY I ERD 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified In accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F,indicating the shingles are acceptable for us in all wind zones up to V6:d = 150 mph (Veit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic® & Supreme: Rww r.ea xNOia M.s dww o, An pre rienm. nennnelee Aroah wimonn hom. wasp." Iveekk Exterior Research and Design, LLC. Certificate of Authorization #9503 N.rmei M.nwN or A,.. per. Mod An. Nigh wind daeve.ee p Anne pue rfMtw n.muAq Arent ri.nr.s /u.rltl 6616' Enponure [xOJsifidry Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 3 of 6 wasp." Iveekk Exterior Research and Design, LLC. Certificate of Authorization #9503 N.rmei M.nwN or A,.. per. Mod An. Nigh wind daeve.ee p Anne pue rfMtw n.muAq Arent ri.nr.s /u.rltl 6616' Enponure [xOJsifidry Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 3 of 6 2 6.2.6 Minimum Nailing - Berkshire®: Snabr4 e1tlA !a Ora tla saAMtt 9 Vi" A bE" 9 yr 6'az" r 7" 6.2.7 Minimum Nailing - Duration® & Duration® Premium: 4 Na9 PnNam Esquema&eeUrO av~Area de Gaw goes �n ' 4xM 6sae xpawx Nyps 5%,Cxpoeae Ph palg. tb M�adW6R C�VOI 6*fyWP. dP=A'POSNI6R 6.2.8 Minimum Nailing - Oakridge®: 4 N.Y1 Fattam Esquama CMt4'*wo fi�lExppaurc ..� 6v6/8"Ex� saw Expos dwv tle66/BpuIBCbvNx Egasrcrort de 5.J8PWy. Exterior Research and Design, LLC. Certificate of Authorization #9503 6 Nad Pa m fswu con Go.. M 0 0Id I i i.i.Y D 79-:, -7 66Y"Expaam CA�avw 68J&"Expowre Exp 16.de66/Bp*, Expal do- 6ra'd, Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 4 of 6 TRINITY RD 6.2.9 Minimum Nailing - WeatherGuard@ HP: a.,u..rwr ip 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard® HP Hip and Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing - Berkshire® Hip & Ridge and High Ridge: 6.3.4 Minimum Nailing - Hip & Ridge with Sealant: eery Fig. 2 - High 'Trod Fasteni 4 Nailsng putroean ( Mimi Shengile —+ Ex and Discard 2„LL Salattt Strip 12" "lastoning S§te" S"Fxposum Distance 92« w Exterior Research and Design, LLC. Evaluation Report 037940.0-:.12 Certificate of Authorization #9503 FL10674 -R6 Date of Issuance: 02/06/2012 Page 5 of 6 6.3.5 Minimum Nailing - WeatherGuard® HP Hip and Ridge: Fig.A y I I TRINITY ERo Fig. C Hip 6 Ridge Shingle Fastening TopVb.v Obit grllo p.to a.. 1° P 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.I. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743; (414) 248-6409; karen.buchmann(o)ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9S03 FL10674-R6 Date of Issuance: 02/06/2012 Page 6 of 6