HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014 ow(ko RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST 8319 Cobblestone Dr Lot 1 Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst -case orientation, name and version of the compliance software tool, name of individual completing the compliance report (1 page) and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level (EPL) Display Card (one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method. ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report (usually one page) 7/17/2017 1:35:45 PM EnergyGauge®- USRCZB v5.1 File Copy Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Express Arden LUCIE LEFT PG Builder Name: D R HORTON INC street: 8319 Cobblestone Dr Lot 1 Permit Office: Saint Lucie County City, State, Zip: , FL, Permit Number: Owner: Express Homes Jurisdiction: Saint Lucie County Design Location: FL, ST_LUCIE_CO_INTL County:: ST. LUCIE (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2350.0 sgft.) Insulation Area Frame - Wood, Exterior R=13.0 1219.20 ft2 2. single family or multiple Tamil Single-familya. g y p y b. Concrete Block - Int Insul, Exterior R=4.1 893.20 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 237.60 ft2 4. Number of Bedrooms 4 d. NIA 10. Ceiling Types (1185.0 sqft.) R= ft2 Insulation Area 5. is this a worst case? Yes a. Under Attic (Vented) R=38.0 1185.00 ft2 6. Conditioned floor area above grade (ft2) 1969 b. NIA R= ft2 ft2 c. NIA R= Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(190.1 sgft.) Description Area a. Sup: Attic, Ret: Attic, AK 2nd Floor 6 320.3 a. U-Factor: Dbl, U=0.34 149.29 ft2 SHGC: SHGC=0.35 12. Cooling systems kBiu/hr Efficiency b_ U-Factor: Dbl, U=0.57 40.80 ft2 a. Central Unit 43.0 SEER:16.00 SHGC: SHGC=0.32 c. U-Factor: NIA ft2 SHGC: 13, Heating systems kBtu/hr Efficiency d. U-Factor: N/A f12 a. Electric Heat Pump 42.0 HSPF:9,00 SHGC: Area Weighted Average Overhang Depth: 1.223 ft. Area Weighted Average SHGC: 0.344 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1969.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 784.00 ft2 b. Conservation features b. Floor Over Other Space R=13.0 741.00 ft2 None c. other (see details) R= 444.00 ft2 15. Credits Pstat Total Proposed Modified Loads: 62.66 PASS Gass/FlaorArea: 0.09i Total Baseline Loads: 65.12 I hereby certify that the plans and soe'6i�ica io "s20vered by Review of the plans and 0�� A � this calculation are in comp lance with the Florida i:Nrgy Code. c t STATE 111 1 specifications covered by this calculation indicates compliance with the Florida Energy Code. gz {rr+n'�- t+ PREPARED BY: 0 Before construction is completed 1 DATE: `-R this building will be inspected for compliance with Section 653.908 x 4 �;"► ( it *illis I hereby certify that this buildlnal as designed, is in compliance Florida Statutes. WY, with the Florida Energy Cod �.116 , a OWNER/AGENT: -_�� ' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.040 On for whole h se. X . e ®Pj 7/17/2017 1:35 PM EnergyGauge® USA - F1aRes2014 Section R405.4.1 Compliant Software Page 1 of 5 cnDnn Denti_')n!A •, PROJECT Title: Express Arden LUCIE LEFT Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1969 Lot # Owner. Express Homes Total Stories: 2 Biock/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 135 Street: Permit Office: Cross Ventilation: County: ST. LUCIE Jurisdiction: Whole House Fan: City, State, Zip: , Family Type: Single-family FL, NewlExisting: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.6 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1969 16379.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 1st Floor 784 6899.2 Yes 1 0 1 Yes Yes Yes 2 2nd Floor 1185 9480 No 5 4 1 Yes Yes Yes FLOORS 9 Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 1st Floor 129 ft 0 784 ft2 -___ 0.7 0 0.3 2 Floor over Garage 2nd Floor _--- __-_ 444 ft2 0.7 0 0.3 3 Floor Over Other Space 2nd Floor ___- _-_- 741 ft2 13 0.7 0 0.3 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1325 W 0 ft2 Dark 0.9 No 0.9 No 0 26.6 ATTIC 1J RBS IRCC #. Type Ventilation Vent Ratio (1 in) Area 1 Full attic Vented 300 1185 fie N N 7/17/2017 1:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 GnQna Qe0r-'X)1e CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 2nd Floor 38 Blown 1185 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below `, .• nmt_ In Wall TTpe Space R-Value Ft In Et In Area @-Vale Era nn AhSnr -C r3dE°l- 1 N=>SE Exterior Concrete Block - Int Insui 1st Floor 4.1 37 0 8.8 0 325.6 ft2 0 0 0.8 0 2 E=>SW Exterior Concrete Block - Int Insul 1 st Floor 4.1 31 0 8.8 0 272.8 ft2 0 0 0.8 0 3 Y_ S=>NW Exterior Concrete Block - Int Insul 1st Floor 4.1 15 0 8.8 0 132.0 ft2 0 0 0.8 0 4 W=>NE Exterior Concrete Block - Int Insul 1st Floor 4.1 18.5 0 8.8 0 162.8 ft2 0 0 0.8 0 _ 5 S=>NW Garage Frame - Wood Ist Floor 13 21 0 8.8 0 184.8 ft2 0 0.8 0 _ 6 W=>NE Garage Frame - Wood 1st Floor 13 6 0 8.8 0 52.8 ft2 0 0.8 0 _ 7 N=>SE Exterior Frame - Wood 2nd Floor 13 36.8 0 8 0 294.4 ft2 0 0.8 0 8 E=>SW Exterior Frame - Wood 2nd Floor 13 39.4 0 8 0 315.2 ft2 0 0.8 0 _ 9 S=>NW Exterior Frame - Wood 2nd Floor 13 36.8 0 8 0 294.4 ft2 0 0.8 0 10 W=>NE Exterior Frame - Wood 2nd Floor 13 39.4 0 8 0 315.2 ft2 0 0.23 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>NW Insulated 1st Floor None .4 2.6 8 20.8 f12 2 S=>NW Insulated 1st Floor None .4 3 6.8 20.4ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SE 1 Vinyl Low-E Double Yes 0.34 0.35 31.2 ft2 1 ft 0 in 12 ft 0 in None None 2 N=>SE 1 Vinyl Low-E Double Yes 0.57 0.32 40.8 ft2 1 ft 0 in 12 ft 0 in None None 3 E=>SW 2 Vinyl Low-E Double Yes 0.34 0.35 15.6 ft2 1 ft 0 in 12 ft 0 in None None 4 S=>NW 3 Vinyl Low-E Double Yes 0.34 0.35 2.5 ft2 6 ft 0 in 1 ft 0 in None None 5 S=>NW 3 Vinyl Low-E Double Yes 0.34 0.35 6.0 ft2 6 ft 0 in. 2 ft 0 in None None 6 N=>SE 7 Vinyl Low-E Double Yes 0.34 0.35 46.8 ft2 1 ft 0 in 0 ft 0 in None None 7 S=>NW 9 Vinyl Low-E Double Yes 0.34 0.35 16.0 ft2 1 ft 0 in 3 ft 0 in None None 8 S=>NW 9 Vinyl Low-E Double Yes 0.34 0.35 31.2 ft2 1 ft 0 in 3 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 462 ft2 462 ft2 64 ft 8.8 ft 13 7/17/2017 1:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 .. — I n L �n A A iVRIVI R`iVJ-GV i't • INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000264 1364.9 74.93 140.92 .244 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:9 42 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 43 kBtu/hr 1446 cfm 0.73 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS --- Supply __ # Location R-Value Area -- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 320.3 ft Attic 78.2 Rz Proposed Qn 2nd Floor --- cfm 78.8 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat: Y Gaoling [( ]Jan [[ ]]Feb [ 1j Mar Heating . [X] Jan [X] Feb [X] Mar Venting ([ ] Jan [[ II Feb [[XJJJJ Mar Ceiling Fans: Apr ) Ma X Jun (X] Juf X Au jXj Se [ Apr ]May [ Jun [ ] Jul 4 Aug Sep [ ]Oct [X A r [ j Ma (jjj Jun [ ]] Jul [ ))) Au Se IXl ] Oct [ Nov (X� NovOec Oct ki Nov Dec [ Dec 7/17/2017 1:35 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PILi 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/17/2017 1:35 PM EnergyGauge® USA - RaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. „ FL, 1. New construction or existing New (From Plans) 9. Walt Types Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 1219.20 ft' b. Concrete Block - Int Insul, Exterior R=4.1 893.20 ft 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 237.60 ft2 4. Number of Bedrooms 4 d. NIA R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=38.0 1185.00 ft2 6. Conditioned floor area (ft2) 1969 b. N/A R= ft2 c. NIA R= ft2 7. Windows- Description Area 11. Ducts R ft a. U-Factor: Dbl, U=0.34 149.29 ft2 a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 320.3 SHGC: SHGC--0.35 b. U-Factor. DbI, U=0.57 40.80 ft2 SHGC: SHGC=0.32 12. Cooling systems k6tu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 43.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 42.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.223 ft. Area Weighted Average SHGC: 0.344 8. Floor Types Insulation Area 14. Hot water systems Cap. 5gallons a. Stab -On -Grade Edge Insulation R=0.0 784.00 ft2 a. Electric EF0.95 b. Floor Over Other Space R=13.0 741.00 ft2 b. Conservation features c. other (see details) R= 444.00 ft2 None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: 8319 Cobblestone Dr Lot 1 Date: 12/26/2017 City/FL Zip: Fort Pierce, FL *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/17/2017 1:36 PM EnergyGauge@ USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number. ,FL, iVIANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. p R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not seated, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. O R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.21A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0,944 Us) when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing (Mandatory)AIi ducts, air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction or rough -in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes, or as authorized by Florida Statutes, to be "substantially leak free" by either of the following: 1. Post -construction test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. 2. Rough -in test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa) across the system, including the manufacturers air handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm (85 Umin) per 100 square feet (9.29 m2) of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 7/17/2017 1:35 PM EnergyGauga USA - FlaRes2014 - Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.2.3 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. 0 R403.3 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105'F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. • R403.4.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. R403.4.3 Heat traps (Mandatory). Storage water heaters not equipped with Integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets_ External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/z inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. © R403.4.4 Water heater efficiencies (Mandatory). 0 R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60`C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors. and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol, Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. 0 R403.5 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. p R403.6 Heating and cooling equipment (Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6, or the closest available size provided by the manufacturer's product lines_ The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 7/17/2017 1:35 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Cam Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling -only equipment. This selection shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multi -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multi -family units, the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment: The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F, and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15. The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil -fired pool and spa heaters. All gas- and -oil -fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shalt not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or solar energy source computed over an operating season. 13 RR404.1 Lighting equipment (Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low -voltage lighting shall not be required to utilize high -efficacy lamps. O R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19. Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 7/17/2017 1:35 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Express Arden LUCIE LEFT PG Builder Name: Street: Permit Office: City, State, Zip: FL, Permit Number: Owner: Express Homes Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered -with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 7/17/2017 1:35 PM EnergyGaugeg? USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Express Arden LUCIE LEFT PG Builder Name: Street: Permit Office: City, State, Zip: FL, Permit Number: Design Location: FL, ST_LUCIE_CO_INTL Jurisdiction: Cond. Floor Area:: 1969 sq.ft. Cond. Volume: 16379 cu ft. Envelope Leakage Test Results Regression Data: C n: us Leakage Characteristics CFM(50): Single or Multi Point Test Data I ELA: HOUSE PRESSURE I FLOW: I EgLA: ACH: ACH(50): S LA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and Flue dampers shall be closed, but not sealed beyond intended infiltration control measures: 3. Interior doors, if installed at the time of the test, shall be open: 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. SIGNATURE: PRINTED NAME: DATE: Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: :.vsc e�:%CS 7/17/2017 1:35 PM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR. BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Express Arden LUCIE LEFT PG Builder Name: Street: Permit Office: City, State, Zip: FL, Permit Number: Design Location: FL, ST_LUCIE_CO_INTL Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Divide by Leakage (Total Conditioned Floor Area) i = (Qn,Out) I I certify the tested duct leakage to outside, Qn, is not greater than the proposed duct leakage Qn specified on Form R405-2014. SIGNATURE: PRINTED NAME: DATE Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by an energy rater certified in accordance with Section 553.99, Florida Statutes. BUILDING OFFICIAL: DATE: �yOf 01E ST�� 7/17/2017 1:35 PM EnergyGaugeO USA - FlaRes2014 - Section R405AA Compliant S Page 1 of 1 Express Arden Lucie Left HVAC Load Calculations for Express Homes ErIE11 11 mi RHVACR85ImITnAL HVAG LOADS Prepared By: Kristin Kelly Florida Breeze 6928 Vickie Circle Suite B West Melbourne, FI 32904 321-951-8767 Friday, July 14, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. F Re copy Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Designed By: Project Date: Client Name: Company Name: Company Representative: Company Address: Company City: Company Phone: Reference City: Building Orientation: Daily Temperature Range: Latitude: Elevation: Altitude Factor: Kristin Kelly June 22, 2017 Express Homes Florida Breeze Kristin Kelly 6928 Vickie Circle Suite B West Melbourne, FI 32904 321-951-8767 Front door faces South Medium 27 Degrees 25 ft. 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter. 42 39.4 n/a n/a 70 n/a Summer: 95 78 47% 50%. 75 53 Total Building Supply CFM: 1,234 CFM Per Square ft.: u.bzI Square ft. of Room Area: 1,969 Square ft. Per Ton: 579 Volume (W): 16,379 Total Heating Required Including Ventilation Air: 29,733 Btuh 29.733 MBH Total Sensible Gain: 33,585 Btuh 82 % Total Latent Gain: 7,199 Btuh 18 % Total Cooling Required Including Ventilation Air: 40,784 Btuh 3.40 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\Users\Steve\Documents\EXPRESS 1969 ARDEN LUCIE LEFT 4EDB PG.rh9 Friday, July 14, 2017, 4:11 FM ad°+r _"'""E�iteSoftu"Ia"ra evel'opinhnt,'inc, Rhvac Rascdontialt� Light G`airiiiz"e'rctaN ' AG 1_aads -. � nda e ie f+>cpress nCac�e ft F'�` B u AFL Ce �Me haum 3293 Miscellaneous Re ort Sys m 1 W' ofe orse (J doo CS.utclo r Out .00 Irldo6r 1 dcor Grains In ut 0-a D We Bulb a .Hu Re H D B D erence Winter: 42 39.4 80% n/a 70 n/a Summer: 95 78 47% 50% 75 52.90 Duct Si`zin • In • uts Main Trunk - Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.01000 0.01000 Pressure Drop: 0.1000 in.wg:/100 ft. 0,1000 in.wg./l00 ft. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. t3,utsidertiDa aNO Mmll::!li:,il-mislim� Winter Summer Infiltration Specified: 0.500 AC/hr 0.260 AC/hr 136 CFM 71 CFM ... ...... _. -- Infiltration Actual: 0.500 AC/hr 0.260 AC/hr Above Grade Volume: X 16,379 Cu.ft. X 16,379 Cu.ft. 8,190 Cu.ft./hr 4,259 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 136 CFM 71 CFM Total Building Ventilation: 0 CFM 0 CFM --System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 35.94 = (0.68 X 0.999 X 52.90 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.500 AC/hr (136 CFM), Construction: Average Summer Infiltration Specified: 0.260 AC/hr (71 CFM), Construction: Average Duet L •n cl 1=ac or 5cenarfos t"�, �. see . 1 Atr o Tt , . =,escri lion Lola ; *eil rt Lea e nsu at an area I!�tDO No 1 Supply Attic 16B 0.12 6 532 0.12 6 591 No 1 Return Attic 16B F:\Users\Steve\Documents\EXPRESS 1969 ARDEN LUCIE LEFT 4EDB PG.rh9 Friday, July 14, 2-U1 i, 4:11 VM nnr l PrPvipw Scope Net Ton ft.' lion Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys CFM Sys CFM Duct Size Building 3.40 579 1,969 33,585 7,199 40,784 29,733 363 1,234 1,234 System 1 3.40 579 1,969 33,585 7,199 40,784 29,733 363; `1234; 1,234 15 Supply Duct Latent 329 329 Retum Duct 1,969 6,452 27,133 •2,045 4.825 8.497 31,958 1,772 27,961 363! 1, 34 1,234 Zone 1 5,5,5,5.5, 1-First Floor 784 14.327 1,970 16,297 18,482 240� ..652,. 652 5.5,5,5,5,, i. 5,5.5,5,5, 2-Second Floor 1,185 12,806 2,855 15.661 9,479 1231;583'; 583 5,5,5,5,5,I, 55 i F:IUsers\Steve\DocumentslEXPRESS 1969 ARDEN LUCIE LEFT 4ED6 PG.rh9 Friday, July 14, 2011, 4:11 FM rntal F3timina Summary Loads window, vinyl frame, u-value 0.34, SHvc u.�35 2A-v-d: Glazing -Double pane low-e (e = 0.60), sliding glass door, vinyl frame, u-value 0.57, SHGC 0.32 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable window, vinyl frame, u-value 0.55, SHGC 0.56 11J: Door -Metal - Fiberglass Core 13AB-Ofcs: Wall -Block, no blanket or board insulation, filled core, siding finish 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud cavity, no board insulation, siding finish, wood studs 166-38: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 22A-pm: Floor -Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 136, Summer CFM: 71 Ventilation: Winter CFM: 0, Summer CFM_0 Total Building Load Totals: 40.8 651 0 740 740 2.5 38 0 57 57 41.2 692 0 766 766 776.7 3,979 0 3,184 31184 1342 3,420 0 3,235 3,235 1969 1,434 0 2,815 2,815 129 4,262 0 0 0 15,877 0 13,286 13,286 6 1,200 1,380 2,580 1,075 5,701 6,776 0 0 0 9,656 2,374 11,658 14,032 4,200 2,550 1,560 4,110 29,733 7,199 33,585 40,784 Total Building Supply CFM: 1,234 CFM Per Square ft.: 0. Square ft. of Room Area: 1,969 579 Square ft. Per Ton: 579 Volume (ft'): 16,379 Bu a�#4fla 5 Total Heating Required Including Ventilation Air: R AM Btuh 29.733 MBH 29,733 Total Sensible Gain: 33,585 Btuh 82 % Total Latent Gain: Total Cooling Required Including Ventilation Air: 7,199 40,784 Btuh 18 % Btuh 3.40 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J•8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:1Users\Steve\Documents\EXPRESS 1969 ARDEN LUCIE LEFT 4EDB PG.rh9 Friday, July 14, 101 1, 4:1 l rrivi F onda BTeeza �a Soffsuai`��Deve,lopitie'nf4lnc,� E pr ss Arden LL[10 L�eit kk pa7 6A „ System 1 Whole House Summary Loads eampanent Area Sen Lat en TAm Gan G 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 146.8 1,401 0 2,489 2,489 window, vinyl frame, u-value 0.34, SHGC 0.35 2A-v-d: Glazing -Double pane low-e (e = 0.60), sliding 40.8 651 0 740 740 glass door, vinyl frame, u-value 0.57, SHGC 0.32 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 2.5 38 0 57 57 window, vinyl frame, u-value 0.55, SHGC 0.66 11J: Door -Metal - Fiberglass Core 41.2 692 0 766 766 13AB-Ofcs: Wall -Block, no blanket or board insulation, 776.7 3,979 0 3,184 3,184 filled core, siding finish 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 1342 3,420 0 3,235 3,235 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1969 1,434 0 2,815 2,815 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 22A-pm: Floor -Slab on grade, No edge insulation, no 129 4,262 0 0 0 insulation below floor, any floor cover, passive, heavy _dryor light wet soil Subtotals for structure: 15,877 0 13,286 13,286 People: 6 1,200 1,380 2,580 Equipment: 1,075 5,701 6,776 Lighting: 0 Ductwork: 9,656 2,374 0 11,658 0 14,032 Infiltration: Winter CFM: 136, Summer CFM: 71 4,200 2,550 1,560 4,110 Ventilation: Winter CFM: 0, Summer CFM: 0 Q - -.-_--__._0 System 1 Whole House Load Totals: 29,733 7,199 33,585 40,784 -C;iack�l=�"'gyres Supply CFM: 1,234 CFM Per Square ft.: 0.627 Square ft. of Room Area: 1,969 Square ft. Per Ton: 579 Volume (ft'): 16,379 S;stzm Load.`s Total Heating Required Including Ventilation Air: 29,733 Btuh 29.733 MBH Total Sensible Gain: 33,585 Btuh 82 % Total Latent Gain: 7,199 Btuh 18 % Total Cooling Required Including Ventilation Air: 40,784 Btuh 3.40 Tons (Based On Sensible + Latent) >�ioes' Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i F:1UserslSteve\Documents\EXPRESS 1969 ARDEN LUCIE LEFT 4EDB PG.rh9 Friday, July 14, 2017. 4:11 PM "Rhvac �Rssiclaiifial & L"t" hCGommeacial`t1VAC Loa s � e oEEwYar� D�veloprtienf,lnc. $Fiortda tease mass Amen Lf: " eR �pX�lEzourna F� 32934 Pa a 7 Equipment Data - System I - Whole House Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency: Air Source Heat Pump 25HBC542A'*30 FV4CNB006 CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Air Source Heat Pump 3646152 45133 16 SEER Air Source Heat Pump 25HBC542A**30 CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Air Source Heat Pump 42000 9 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODS: 95F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 33,585 Btuh, Lat. gain: 7,199 Btuh, Sen. loss: 29,733 Btuh, Entering clg. coil DB: 79.7F, Entering clg. coil WB: 64.6F, Entering htg. coil DB: 65.6F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1234 CFM, Req. htg. airflow: 363 CFM F:\Users\Steve\DocumentslEXPRESS 1969 ARDEN LUCIE LEFT 4EDB PG.rh9 Friday, July 14, 2017, 4:11 PM Rti�a`c ResEtieritial & Ligh'f Contcneia15H1lAG' Noad&' k "e ;`r a ='Elitie So "axle` eve optrierit "Inc! �`xpre fivxien U+�cr"e efl pJo cis tease Page 8 Melbourne, . _ 329�4 S stem 1 Room Load Summafy Hl;g Mt Run Ru C g C*lg Min Act 0o Area Sens tg D ct Duct Se s Lat Cl Sys No S B u CF Size Ve 13tuh 13tuh CFM CFM --Zone 1-- 1 First Floor 784 18,482 240 5,5,5,5, - 14,327 1,970 652 652 5,5,5,5, 5,5,5 2 Second Floor 1,185 9,479 123 5,5,5,5, - 12,806 2,855 583 583 5,5,5,5, 5,5,5,5 Duct Latent 329 Return Duct 1,772 _ T 6,452 2,045 _ _ _ System 1 total 1,969 29,733 363 33,585 _ 7,199 _ _ 1,234_ 1,234 ' System 1 Main Trunk Size: 15 in. Velocity: 1,008 ft./min Loss per 100 ft.: 0.093 in.wg Duct size results above are from Manual D Ductsize. Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize report for duct velocities and other data. �cx3li , - S st2 Su. iman C*oot' .9 Se si l ate t Se sibi� to Tota n S 0 1t BfiJ,h B uh Btuh Net Required: 3.40 82% / 18% 33,585 7,199 40,784 �> Actual: 3.76 90% / 10% 40,589 4,544 45,133 E ' en "Oats ,ui Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HBC542A"30 25HBC542A*'30 Indoor Model: FV4CNB006 Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 9 HSPF 16 SEER Sound: 0 0 Capacity: 42,000 Btuh 45,133 Btuh Sensible Capacity: n/a 40,589 Btuh Latent Capacity: n/a 4,544 Btuh AHRI Reference No.: n/a 3646152 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 95F, SOWS: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: 33,585 Btuh, Lat. gain: 7,199 Btuh. Sen. loss: 29,733 Btuh, Entering clg. coil DB:79.7F, Entering clg. coil WB: 64.6F, Entering htg. coil DS: 65.6F, 3 6 I Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1234 CFM, Req. htg. airflow: 363 CFM F:\Users\Steve\DocumentslEXPRESS 1969 ARDEN LUCIE LEFT 4EDB PG.rh9 Friday, July 14, 2017, 4:11 PM yqq WrQidi�nkgsdNro� Contractor Florida Breeze Mechanical License # CAG1814113 Building Plan # County, Town, Municipality, Jurisdiction Header Information Home Address (Street or Lot -A, Block, Subdivision) REQUIRED ATTACHMENTS' Form RPER 1.01 8 Mar 10 ATTACHED Manual J1 Form (and supporting worksheets): Yes ❑X No ❑ or MJ1AE Form' (and supporting worksheets): Yes ❑ No ❑X OEM performance data (heating, cooling, blower): Yes ❑X No ❑ Manual D Friction Rate N/orksheet: Yes ❑ No ❑X Duct distribution system sketch: Yes ❑ No ❑X HVAC ••! CALCULATION (IRC M1401.3) Design Conditions Building Construction Information_ Winter Design Conditions OF Building Orientation (Front door faces) South Outdoor temperature 42 70 OF North, East. West. South, Northeast, Northwest, Southeast, Southwest indoor temperature Number of bedrooms 5 Total heat loss 29733 BfU/h Conditioned floor 1969 Sq Ft Summer design Conditions area Outdoor temperature 95 of Number of occupants 6 Indoor temperature 75 of Windows Roof Grains difference 53 G Gr @ 50 % Rh Eave overhang depth 9 9 Ft Sensible heat gain 33585 Btt.t/h Internal shade �_ Eave Latent heat gain 7199 Btu/h Blinds, drapes, etc Depth Window Total heat gain 40784 Btu/h Number of skylights EQUIPMENTHVAC • 41 Heating E ui ment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump Heating CFM 1446 CFM Furnace, Heat pump, Boiler, etc. Air conditioner, Heat pump, etc Model 25HBC542A**30 Model 25HBC542A**30 Cooling CFM 1446 CFM Heating output capacity 42000 Btu/h Sensible cooling capacity 40589 Btu/h Heat pumps - capacity at winter design outdoor conditions ra Latent tooting capacity 4544 BtU/h Auxiliary heat output capacity Btu/h Total cooling capacity 45133 Btu/h WAC DUCT DISTRIBUTION SYSTEM ! .i Design airflow 12 37 CFM Longest supply duct: 64 Ft Duct Materials Used (circle) Trunk Duct: Duct board Flex, Sheet metal, External Static Pressure (ESP) 0.32 IWC Longest return duct: -3-0 Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) 0L25 IWC Total Effective Length (TEL) 90 Ft Available Static Pressure (ASP) 0.073 IWC Friction Rate: 0.08 IWC ASP = ESP - CPL Friction Rate = (ASP - 100) - TEL Contractor's Printed Name Kristin Kelly Contractor's Signature Branch Duct: Duct board, lex Sheet metal, Lined sheet metal, Other (specify) Date 1 /10/2016 ' The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. Air Conditioning Contractors of America Manual'S (Residential Equipment Selection) Project Information Cooling Design Information Name: Outdoor Design Temp: 91 'F db Summer City: Outdoor Design Temp: 43 °F db IWinter State: Altitude: = Altitude Adjustment: 1.00 Indoor Design Temp: 75 °F db F 50 %RH F 63 °F wb Manual J Load Calculations Total Load Sensible Latent SHR Heat Loss 40784 33585 7199 0.823 OEM Information Airflow Calculations Design TD for Airflow 18 Design Sensible CFM r 1696 Manufacturer. lCarrier I Furnace Model #: I. AFUE:= Coil or Fan -Coil Model #: 1 FV4CNF006T00 �� Condenser Model #: 125HBC542000 1 SEER: 16.0 HSPF: 9.00 (A) Manufacturer's Cooling Performance Data Lower Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature 67 45,650 1 31,320 14,330 F5.686 Rated CFM @Design RA Temperature f 1225 63 42,218 35,720 6.498 FO.846 Rated CFM @ Rated RA Temperature 62 41,360 36.820 4,540 0.89 (B) Manufacturer's Cooling Performance Data Higher Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFPA @ Rated RA Temperature 67 47,450 35,190 12.260 0.742 Rated CFPA @ Design RA Temperature 1325 63 44,074 40,510 3.564 0.919 Rated CFM @ Rated RA Temperature F 41.840 F 1.390 0.968 1wanucaccucGc s 1,ovn19 rncconnancc vacs tuuerpoiaceo) Design Return Air Outdoor Temperature = 95 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR 43,244 1,890 0.958 Excess Latent Capacity Calculation + -2,655 -2.655 Capacity @ Design CFM / RA (F wb) 1696 63 46,133 40,589 4,544 0.899 Equipment Capacity as a % of Design F 110.66 . 120.85% 33.12% Manufacturer's Heat Pump Data Capacity Capacity Balance Supplemental @@ 4� @@ 170 P� Heat Required 41,790 0 24,580 25.8 15.87 Manufacturer's Furnace Data Input Output Desired Calculated Capacity CapacityAFUE Temp. �Airflow � It