Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE.FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjeetName: THE GRAND CARLI;ON Builder Name: Street SPANISH LAKES Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. " ;'�� Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1712.0 sqft.) Insulation Area 2. Single family or multiple family Single-family Concrete Block - Int Insul, Exterior R=4.1 1312.00 ftz b. b. Frame - Wood, Adjacent R=11.0 400.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 2 d. NIA R= ft2 10. Ceiling Types (1720.0 sqft.) Insulation Area 5. Is this a worst cased Yes a. Under Attic (Vented) R=30.0 1720.00 ftZ 6. Conditioned floor area above grade (ft2) 1720 b. N/A R= ft? Conditioned floor area below grade (tt2) 0 c. NIA R= ft 11. Ducts R fIz 7. Windows(141.3 sgfL) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 168 a. U-Factor: Sgl, U=0.50 141.25 fie SHGC: SHGC=0.32 b. U-Factor. N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a a. Central Unit 34.8 SEER:15.00 c! U-Factor. NIA fN SHGC: 13. Heating systems kBhAr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 35.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.320 14. Hot water systems 8. Floor Types (1720.0 sgft.) Insulation Area a. Electric Cap: 40 gallonsEF: a. Stab-0a-Grade Edge Insulation R=0.0 1720.00 ftz b. Conservation Seatures 0.920 b. NIA R= ft2 None c. NIA R= ftz 15. Credits CF, WHF, Pstat Total Proposed Modified Loads: 42.52 Glass/Floor Area: 0.082 PASS Total Baseline Loads: 42.69 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Review of the plans and specifications covered by this -VFiE 5r4� Ot ,f t•� ` ' ?�p� Code. calculation indicates compliance.n `';::.�`�;�0 with the Florida Energy Code. k ti;'•.::,�°°°: , PREPA D BY Before construction is completed w DATE:I n this buildingwill be inspected for P compliance wlth section 553.g013 1.� „ 4_ t?..' �...00�"' I hereby certify that this building, as designed 's in co nce Florida Statutes. ry with the Florida Energy Code. / co WE OWNER/A T: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 2/2912016 8:27 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 ' PROJECT Title: Building Type: Owner: #of 15fs: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: THE GRAND CARLTON Bedrooms: 2 User Conditioned Area: 1720 Total Stories: 1 1 Worst Case: Yes Rotate Angle: 135 Cross Ventilation: No Whole House Fan: Yes Single-family New (From Plans) Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address SPANISH LAKES ST. LUCIE COUNTY FT. PIERCE, FL, CLIMATE v Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 ' Blockl 1720 13760 a SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1720 13760 Yes 4 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 187 ft 0 1720 ftz 1 0 0 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 1863 ftz 0 ftz Medium 0.75 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1720 ftz N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 1720 ftz 0.11 Wood 2/29/2016 8:27 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 i FORM R405-2014 WALLS V# Omt To Wall TypeAdjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 N=>SE Exterior Concrete Block - Int Insul Main 4.1 48 8 384.0 ft2 0 0.75 0 _ 2 E=>SW Exterior Concrete Block - Int Insul Main 4.1 34 8 272.0 ft? 0 0.76 0 _ 3 S=>NW Exterior Concrete Block - Int Irrsul Main 4.1 48 8 384.0 IF 0 0.75 0 _ 4 W=>NE Exterior Concrete Block - Int Insul Main 4.1 34 8 272.0 ft2 0 0.75 0 _ 5 N-SE Garage Frame - Wood Main 11 50 8 400.0 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>NW Insulated Main None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. V Wail Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N-SE 1 Metal Single (Tinted) Yes 0.5 0.32 27.0 ft2 2 ft 0 in 6 ft 0 in Drapestblinds None ' 2 N-->SE 1 Metal Single (Tinted) Yes 0.5 0.32 40.0 W 2 ft 0 in 6 ft 0 in Drapesibfinds None 3 E=>SW 2 Metal Single (Tinted) Yes 0.5 0.32 39.8 ft2 2 ft 0 in 6 ft 0 in Drapesiblinds None ' a 4 W=>NE 4 Metal Single (Tinted) Yes 0.5 0.32 13.5 ft 2 ft 0 in 6 ft 0 in Drapesiblinds None 5 W=>NE 4 Metal Single (Tinted) Yes 0.5 0.32 6.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 6 W=>NE 4 Metal Single (Tinted) Yes 0.5 0.32 15.0 fP 2 ft 0 in 6 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1040 fF 1040 ft2 50 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1146.7 62.95 118.39 .1855 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 35 kBtuJhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:16 34.8 kBtu/hr 1044 cfm 0.8 1 sys#1 2/29/2016 8:27 AM EnergyGauge® USA - FlaRes2014 Section R405A.1 Compliant Software Page 3 of 4 - t =nRM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM Collector Storage FSEC Cert # Company Name System Model # Collector Model # Area Volume FEF None None fF DUCTS — Supply — — Return — - Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 168 ftz Attic 25 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [[ jj Jan Heating [X] Jan [[ jj Feb [X] Feb Mar Mar [ j j ] Apr [ Apr [ ] May ] May t ] Jun ri Jun Jul rl Jul [X Au [ Au Sep rl Se Oct Oct XNov X Nov Nov Dec Dec Dec Venting [[ ]] Jan [[ ]] Feb X Mar [X] A r [ ] Ma [ l Jun Jul [ Aug Se Oct Thermostat Schedule: HERS 2006 Reference Hours 11 12 Schedule Type 1& 2 3 4 5 6 7 8 9 10 Cooling (WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PM 68 68 68 68 68 68 8 68 68 68 68 68 68 66 66 Heating (NEH) PM 68 68 68 68 68 66 68 68 68 68 66 66 212912016 8:27 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 =dRM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: Street: SPANISH LAKES Permit Office: " City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Wails and sill plate shall be sealed. • The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in Q esubstantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. She air barrier Shah be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed m the lauildm% thermal envelope shad be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Showerltub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. �iseplace An air barrier shall be installed on fireplace uuatts. Fireptaaes shall have gasketed doors goonin st•97 AR/ cncigyuaugew USA - FlaReS2014 Section R405.4.1 Compliant Software Page i of 1 , FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. SPANISH LAKES, FT. PIERCE, FL, 1. New construction or ebsting New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1312.00 ftz 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 400.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? yes 10. Ceiling Types Insulation Area a. Under Attic (vented) R=30.0 1720.00 ft2 6. Cond'itkmed floor area (ftz 1720 b. NIA R= ft2 7. Windows" Description Area c. N/A R= ftz a. U-Factor: Sgl, U=0.50 141.25 fie 11. Ducts R ft2 SHGC: SHGC=0.32 a. Sup: Attic, Ret Attic, AH: Attic 6 168 17 U-Factor. NIA ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A 4 ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A fF 13. Heating g systems kBtu/hr Efficiency Area Weighted Average overhang Depth: 2.000 ft. a. Electric Heat Pump 35.0 HSPF:8.50 Area Weighted Average SHGC: 0.320 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2 a. Electric Cap: 40 gallons b. N/A R= ft2 ER 0.92 c. NIA R= ft2 b. Conservation features None 15. Credits CF, WHF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) ©FtE WAP* in this home before final inspection. Otherwise, a new EPL Display Card will be completed - based on installed Code compliant features. er'®�' Builder Signature: `\rr: Date: Address of New Home: Cit Y y/FL Zipr t G;�r- ob 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation ' not DEFAULT. 2/28/2016 8:27 AM EnergyGauge® USA - FlaRes2014 -Section R405.4.1 Compliant Softwa c _, r1 e f