HomeMy WebLinkAboutPROJECT INFORMATIONProject Summary Dab -- wrightsoft® Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE GRAND CARLTON, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 18837 Ducts 5998 Central vent (0 cfm) 0 Humidification 0 Piping 0 Equipment load 24834 Infiltration Method Construction quality Fireplaces 90 OF 75 OF 15 OF L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Btuh Structure 16243 Btuh Btuh Ducts 9055 Btuh Btuh Central vent (0 cfm) 0 Btuh Btuh Blower 0 Btuh Btuh Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24033 Btuh Simplified Average 0 Heating Cooling Area (W) 1646 1646 Volume (ft3) 15336 15336 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 97 51 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.047 cfm/Btuh 0 in H2O Latent Cooling Equipment Load Sizing Structure 2135 Btuh Ducts 2467 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 4603 Btuh Equipment total load 28635 Btuh Req. total capacity at 0.70 S HR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.85 Calculations approved byACCA to meet all requirements of M .►" wrightsoft RlghtSuite(sl Universal 2015 15.0.19 RSU08101 Itan pµ,S ;jar-01r�10:29:11 Ig Page 1 ACCA ...ick Calos\DocumentslWYNNE-THE GRAND CARLTON.rup Calc = Md8 Front Door faces: N -�+ wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-4666796 Email: QUICKC4LCS@PAL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 151.2 ft 32.0 ft 3 Room height 9.4 ft d 9.4 ft heat/cool 4 Room dimensions 14.0 x 18.0 ft 5 Room area 1631.5 ft2 252.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (atuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 0:143 ne ' 4.00 2 55 517 458 .1835 1166 0 0 D 0; �: 1Ac1om 1.270 'ne 35,56 7043 38 0 -1344 2662 0' _ 0 0 . 0 11 DO 0r390 me ! ... 10.92 _ w 11.' .._ .:.21 21 .. a 229 .. "° 238 _ .; 5 0 ..: ..` 0 ..... 0 ' 0 yJ 13A4ocs 0.143 se 4.00 2.55 150 130 522 332 0 0 0 0 11 I--G, 1A-c1om 1.270 se„ 35.56 70.95 20 0 711, 1419 0 0 0 0 W 13A flocs. 0143 s : 4.00 :, .2.55 40 _. . ,`: 40 ': , ;: ` "16D .. ,102 :•.. Q . _._ ' 0 w . 13A-4ocs 0.143 sw 4.00 2.55 395 395 1581 1005 169 169 677 431 W 13A-0ocs 0143 nw' -;. 2.55 320 258 1034 , , 657 ; '' 132 _` 108 432 275 . 9A Glom 1:270 nw .'A.'00 35.56 70.43 38 0 1344 2662 0 0 0 0 1Ac1om • 1)270 nwI 35.56 45.24 12 0 415 528 12 x Q 415 528 1A c1om:1270 , nw ..35.56 A5.24 12 = 0 : ` 427 _ . ;. 543 t 12 ` 0 427 . _ 543' P 12C-0sw 0.091 2.55 1.28 235 599 302 0 . 0 0 0 _ ,16A 30md,;, . 0.032 ; '.':;; 0:90 ,'.2 32 _235 1632 , 1032 , . - 1462 . ,::. 3785 _ °,., , .. 252 '. ,252 _."r ..226 . ';, 585 F 22A-tp1 0.989 - 27.69 , 0.00 1632 151 4186 0 252 32 886 0 tt,.-,. i 6 c) AE D excursion 0 154 Envelope loss/gain 15848 15400 3063 2515 12 a) Infiltration 2989 843 632 178 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 18837 16243 3696 2693 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18837 16243 3696 26M 15 Duct loads 32% 56% 5998 9055 32% 56% 1177 1501 Total room load 24834 25298 4872 4194 Air required (cfm) 1 1160 11601 12281 192 Calculations awroved bvACCAto meet all requirements of Manual J 8th Ed. wri htsoft' 2016-Mar-0110:29:11 9 RightSuite® Universal 2015 15.0.19 RSU08101 Page 1 ACC` ...idc Calcs\Documents\WYNNE-THE GRAND CARLTON.rup Calc = MJS Front Door faces: N wrightsoft, Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Calculations aDDroved bvACCAto meet all requirements of Manual J 8th Ed. wi htsoft® 2016-Mar-0110:29:11 9 RightSuite® Universal 2015 15.0.19 RSU08101 Page 2 �� r ...idt Calcs\Documents\WYNNE-THE GRAND CARLTON.rup Calc = MJ8 Front Door faces: N - - wrightsoft® Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M. BATH KITCHEN 2 Exposed wall 8.0 ft 0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 7.0 x 8.0 ft 1.0 x 192.0 ft 5 Room area 56.0 ft2 192.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz°F) (Btuh/ff=) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 '+ 0 0 0 �---D 1A-clom 1.270 ne 35.56 70.43 0. 0 0': 0 0. 0 0 0 1100 0.390 ne 10.92 11.31 0, 0 0 - 0 .. 0 A - 0 0. VN 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 LG 1A-clom 1.270 se 35.56, 70.95 0 0 0 0 0 0 0 0 W 13A-1140cs 0.143 s 4.00 2.55 ` : O '0 0 0 6 0 0 0 W 13A-4ocs 0.143 sw 4.00 2.55 75 75 301 191 0 0 0 0 W 13A-4ocs `0.143 'rw 4.00 -2.55 0 _ 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 70.43 0 0 0 0 0 0 0 0 1Aclom 1270 nw 35.56 - 45.24 „0 0 0 0 0 0 0. 0 1A-clom. -t= nw 35.56: 45.24 0 : 6 '0.. 0 .. 0'. 01 61 0 P 12C-Osw 0.091 - Z55 1.28 0 0 0 0 75 75 192 96 C 16A-30md 0.032 -. 0 90 2.32 . 56 56 50 130 192' 192 172 445 F 22A tpI , 0.969 - 27.69 0.00 56 8 222 0 192 0 0 0 6 c) AE D excursion S8 -56 Envelope loss/gain 573 283 364 486 12 a) Infiltration 158 45 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 731 328 364 486 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 731 328 364 486 15 Duct loads 32% 56% 233 183 32% 56% 116 271 Total room load 964 511 479 756 Air required (cfm) 45 23 22 35 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. htSOtit" 2016-Mar-M 10:29:11 WPI 9 RightSuite@ Universal 2015 15.0.19 RSU08101 Page 3 -ZC�` ...idc Calcs\Documents\WYNNE-THE GRAND CARLTON.rup Calc = MJS Front Door faces: N wrightsoftm Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICXCALCS@AOL.COM 1 Room name BATH BEDROOM 2 2 Exposed wall 5.0 ft 30.2 ft 3 Room height 9.4 ft heaticool 9.4 ft heat1cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 190.5 ft 5 Room area 45.0 ftZ 190.5 ft2 Ty Construction U-value Or HTM Area (ftZ) Load Area (ftZ) Load number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A flocs 0.143 ne 4.00 2:55 ' . .. 47 47 188 120 14t - 141 ; 565 359 :!A-c1om 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 �-- D 11 DO 0.390 ne • . 10192 11.31 0 0- a -0 0 0 ' ' 0 0 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 94 74 296 188 11 1Aclom 1.270 se 35.56 70.95 0 0 0 0 20 0 711 1419 W 13A-4ocs 0.143 's 4.00 - 2.55 _ ; - 0. 60,; 0 0 40, 40 160 102 W 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0. 9 9 38 24 W�G13A-4ocs 0A43 nw 4:00 ` 2.55 0 0 0 0 -0 0. 0 0 l 1A-c1om 1.270 nw 35:56 70.43 0 0 0 0 -0- 0' 0, ., 0 1A-c1om, 11.270 nw 35.56 45.24 0 0 '. 0 0• 0- 0 0 0 C %glom '. 1. 70 nw 35.56 95.24 0 0 " G 0 0 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0_ 0 C 16A-30md b.032 - 0.90 2`32 45 45 _ 40 104 ' 191 191 171 442 F . " 22A-tpl 0.989 . - 27.69 0.00 45 5 138 0 191 30 835 0 6 c) AED ecursion -26 145 Envelope loss/gain 367 198 2775 2679 12 a) Infiltration 99 28 598 169 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 466 226 3373 2847 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 466 226 3373 2847 15 Duct loads 32% 56% 148 125 32% 56% 1074 1587 Total room load 1 614 1 352 4447 4434 Air required (cfm) 29 16 208 203 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wri htsoft' 2016-Mar-0110:29:11 9 Right -Suite® Universal 2015 15.0.19 RSU08101 Page 4 ACC:A ...idc Calcs\Documents\WYNNE-THE GRAND CARLTON.rup Calc = MJS Front Door faces: N - - wrightsoft9 Right-M Worksheet Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466,6796 Email: QUICKCALCS@AAL.COM 1 Room name ENTRY LAUNDRY 2 Exposed wall 6.0 ft 6.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 6.0 x 10.0 ft 7.0 x 6.0 ft 5 Room area 60.0 ftz 1 42.0 ft' Ty Construction U-value Or HTM Area (ft=) I In Load Area (ft� Load number (Btuh/ftz-°F) (Btuh/ft') or perimeter (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-40cs 0.143 ne 4.00 - 2.56 0 :_ 0 0 0 0 '0 0 0 1Aclom 1.270 ne 35.56 70.43 0 0 0 0. 0 0 0 0 11D0 i0.390 .ne 10.92 11.31 0 0 0`. 0 0 0 ': 0 0 yJ 13A-4ocs 0.143 se 4.00 2.55 56 56 228 144 0 0 0 0 11 I-G 1Ac1om 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.55 _ 0 0 '0 0 - 0. 0 :... 0. 0 W 13A-4ocs 0.143 . sw 4.00 2.55 0 0 0 0. 56 56 226 144 �l 13A-4ocs_ 0.143 nw 4.00 2.55 0 0 0 0 '0 0 0 0 I-G 1Ac1om 1.270 nw 35.56 70.43 0. 0 0 0 0 0 0 0 IA-c1om 1.270 nw 3556 45.24 0 0 0 : 0 0 0 0 0 1Aclom 1.270 nw, 35.56 45.24 0 0 �0. ` 0';: 0 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 94 94 240 _ 121 66 66 168 84 G 16A 30md 6.032 - 0:90 2.32 60" 60 54 139 42 .42 .38 _ 97 F 22A-tpl 0.989 . - 77.69 0.60 60 6 166 _ 0 42 6 166 0 6 c) AED mcursion -` S7 Envelope loss/gain 685 358 597 288 12 a) infiltration 119 33 119 33 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 804 391 716 322 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 804 391 716 322 15 Duct loads 32% 56-1.256 218 32% 56% 228 179 Total room load 1060 610 944 501 Air required (cfm) 50 28 44 23 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. T��11r.. wri FrftsoTt' 2016-Mar-0110:29:11 F9 RightSuite® Universal 2015 15.0.19 RSU08101 Page 5 / � ...Ick Calcs\Documents\WYNNE-THE GRAND CARLTON.rup Calc = MJ8 Front Door faces. N wrightsoft, Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUia<CALCS@AOL.COM 1 Room name SITTING ROOM GREAT/DINING 2 Exposed wall 30.0 ft 25.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 20.0 x 10.0 ft 1.0 x 468.0 ft 5 Room area 200.0 ftz 468.0 ff2 Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (Btuh/ft'L°F) (Btuh(ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 ne 4.00 2.55 94 73 292 . 186 235 197 790 502 1 G D !A-clom 1.270 ne 35.56 70.43 0 0 0 0 38 0 1344 2662 11D0 0.390 ne 10.92 11.31 21 21 229 238 0 0 0- .0 yJ 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 t-G 1Aclom 1.270 se 35.56 70.95 0 0 0, 0 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.65 0_ 0 0 0, 0, .. 0 0 0 W 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 W 13A-4o6s : 0:143 nw 4.00 2.55 188 .150 601 ; , 382 0 0 0 `' 0 1Aclom 1.270 nw 35.56 70.43 38 0 1344 ° 2662 0 0 0 0 1Aclom 1.270 nw 35.56 .45.24 � 0 0 0 0 0. 0 0 0 1Aclom 1.270 nw, , 35.56 _. 45.24 0' 0 0 0 0 0 0 0' P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 200 200 179 . 464 .468 468 419 1086 F 22A-tpl 0.989 - 27.69 0.00 2W 30 831 0 4W 25 692 0 6 c) AE D e)cursion 402 -440 Envelope loss/gain 3477 4334 3245 3810 12 a) Infiltration 593 167 494 139 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 4070 4501 3739 3950 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4070 4501 3739 3950 15 Duct loads 320/a 56% 1296 2509 32% 56% 1191 2202 Total room load 5368 7010 4930 6151 Air required (cfm) 251 321 230 282 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. i htsofC 2016-Mar-0110:29:11 wr 9 RightSuiteO Universal 2015 15.0.19 RSU08101 Page 6 ��` ...Idc Calcs\Documents\WYNNE-THE GRAND CARLTON.rup Cale = MJ8 Front Door faces: N