HomeMy WebLinkAboutREVISIONA
r�
J
OFFICE USE ONLY:
DATE FILED:
REVISION FEE:
1. LOCATION/ST3j%ONTEREY
ADDRESS. . -
PERMIT# 1.603-0345
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING& CODE REGULATION DIVISION-
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
REVISED ENERGY CALCS
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
ST. LUCIE COUNTY
CERT. #:. 8898
BUSINESS NAME:
orpora ion
QUALIFIERS NAM
0 South US Ilwy. 1 Suite
ADDRESS:
CITY; Fort St. Lucie STATE:
ZIP:
PHONE (DAYTIME): -
FAX: 772
878-7 56
4. OWNER/BUILDER INFORMATION:
Wynne Building Corporation
NAME:
ADDRESS: outh USHwy. 1 Suite4O2
CITY:
STATE: FL
ZIP: 3
PHONE: (772) 878-5513
FAX:
(772) 878-1656
5. ARCHITECT/ENGINEER INFORMATION:
BRADEN & BRADEN
NAME:
ADDRESS:
CITY: STUART
STATE: FL
ZIP: 34996
PHONE (DAYTIME): (772) 287-8258
FAX:
Revised 07/22/2014
fi i � ,"•• '
FORNf R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:, THE GRAND CARLTON
Builder Name: 'ST. LLTC, COLN'NBUILDING19iVL IUN
Street: SPANISH LAKES
Permit Office: REVIEWED FOR CO- WL S CZ
City, State, Zip: FT. PIERCE, FL,
Permit Number. xEviE�ya: gy
Owner: ?),� ��j�Q ��
Jurisdiction: DATE
�,JO13
Design Location: FL, Fort Pierce
PLANS AS, P R-Nfr MUSYBE _1
.
1. New construction or existing New (From Plans)
9: Wall Types (1712.0 "sgft.)
Insulation Area
2. Single family or multiple family single-family,
a. -Concrete Block - Int Insul, Exterior
R=4.1 1312.00 ft2
3. Number of units, if multiple farriily 1
b. Frame -Wood, Adjacent
c: NIA
R=11.0 400.00 ft2
R= ft2
4: Number of Bedrooms 2
d. N/A
R=. ft2
5. is this a worst case? Yes
10. Ceiling Types (I720.0 sgft.).
Insulation Area
a: Under Attic (Vented)
R=30.0 1720:00 ft2
6. Conditioned floor area above grade .(ft2)- 1720
b; N/A
R= 'ft2
Conditioned floor area below -grade (ft2) 0
c. N/A
R= ft2
11. Ducts
ft2
7. Windows(141.3 sgft.) Description Area
A. Sup: Attic, Ret: Attic, AH: Attic
�6 147
a. U-Factor. Sgl, U=0:50 141.25 ft2,
SHGC: SHGC=0.25
b. U-Factor. N/A ft2
12. Cooling•systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.8 8EER:15,00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. WA ft2
a. Electric Heat Pump
35.0 HSPF:8.50
SHGC:
Area. Weighted Average Overhang.. Depth; 3.699 .ft.
Area. Weighted'Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1720.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Ede Insulation R=0.0 1720.00 ft2
g
b: Conservation.features
EF: 0.920
b. N/A R= ft2
None
c. N/A R= ft215.
Credits
Pstat
Glass/Floor Area: 0:082 Total Proposed Modified Loads: 43.30
PASS
Total Baseline Loads: 43.30
1 hereby certify that the plans and specifications covered by
Review of the plans and
EKE SxA��`
this calculation are in compliance with the Florida Energy
specifications covered by this
p
.y O
Code.
calculation indicates compliance
ski k;
Qwith
the Florida.Energy Code.
PREPARED BY: ._. _
Before construction is completed
DATE:
this. building will be inspected -for
compliance with Section 553.908
4v
w n
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
✓,� 5�
with the Florida Energy Code.
OWNER/q�G
BUILDING OFFICIAL:
DATE:
DATE:
-S9
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as,
certified factory -sealed in accordance with.R403.2.2.1.
- Compliance requires. an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402:4.1.2.
Ali
! � ;^ A -pit 4
6/21/201611:18.AM EnergyGauge®.USA-'FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014�
PROJECT
Title:
Building Type:.
Owner.
#ofUnits:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
THE GRAND CARLTON Bedrooms: 2
User Conditioned Area: 1720
Total Stories: 1
1 worst Case: Yes
Rotate Angle: 135
Cross Ventilation:
whole House Fan:
Single-family
New (From Plans)
Address Type:
Lot #
Block/SubDivision:-
PlatBook:
Street:
County:
City, State; Zip:
Street Address
SPANISH LAKES.
ST. LUCIE'COUNTY
FT. PIERCE,
FL
CLIMATE
V Design Location
IECC Design:Temp
TMY Site Zone. 97:5 % 2.5 %
Int Design Temp Heating .Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort.Pierce. FL ST_LUCIE CO_1NTL 2 �.39 90
70
75 722
_ 62 Low
BLOCKS
Number
Name:
Area Volume
1
Blocki
1720 13760
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
'Main
1,120 13760 Yes 4
2
1 Yes
Yes Yes
FLOORS
#
Floor Type_
Space Perimeter R Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge lnsulatio Main 187 It 0
1.720.ft2
1 0 0
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt.
Tested
Emitt , Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 1813`ft2 O.ft2 Light
0.6
No 0.9
No 0 18:4
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1720:ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing`Frac
^ Truss Type
1
Under Attic (Vented).
Main 30 1720. ft2
0.11
Wood
FILE Copy
6/21/201611:18 AM EnergyGauge@ USA-- FlaRes2o14 Section R405A.1 Compliant Software Page 2 of 4
FORM R405-2014
%
tea_
F/
WALLS
Adjacent
-#--0mt Io WaII-Type
Cavity Width Height Sheathing Framing Solar Below
Space a ValueFt �n-_Et- n Area R- talue-F-actioa._.Absor 1Grade°lo_
�
- 1 N=>SE Exterior Concrete Block - Int Insul
Main 4.1 48 8
384.0 ftz
0 0.6
0
-2 E=>SW Exterior Concrete Block - Int.lnsul
Main. 4.1 34 •8
272.0 ftz
0 0.6
0
-3 S=>NW Exterior Concrete Block - Int lnsul
Main 4.1 48 8
384.0 ftz
0 0.6
0
_ 4 W=>NE Exterior Concrete Block - Int Insul.
Main 4:1 34 8
272.0 ftz
0 0.6
0
_ 5 N=>SE Garage Frame - Wood
Main 11 50. 8
• 400.0 ftz
0 0.6
0
DOORS
# Ornt Door Type Space Storms
U-Value Width
Height
Area
Ft In
Ft In
1 S=>NW Insulated Main None
.28 3
6 8
20 ft2
WINDOWS
Orientationshown is the entered orientation => chan ed to Worst Case.
/ Wall
Overhang
V # Cimt. ID Frame Panes NFRC U-Factor SHGC:
Area :Depth _ Separation
Int Shade
Screening
1 N=>SE 1 Metal Single (Tinted)
Yes 0.5 0.25
27.0 ftz - 2•ft 0 in 1 It 4 in
Drapes/blinds
None
2 N=>SE 1 Metal Single. (Tinted)
Yes 0.5 0.25
40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
3 E=>SW 2 Metal Single (Tinted)
Yes 0.5 0.25
39.8 ftz 2 ft 0 in 1 ft 4 in
Drapes/blinds
None
4 W=>NE 4 Metal Single (Tinted)
Yes 0.5 0.25
13.5 ftz 2 ft 0 in 1 ft 4 in
Drapes/blinds
None
5 W=>NE 4 Metal Single (Tinted)
Yes 0.5 0.25
&0 ftz 2 ft 0 in 1.ft 4 in
Drapes/blinds
None
6 W=>NE 4 Metal .Single (Tinted)
Yes- 0.5 0.25
15.0 ft' 2 ft 0 in 1 ft 4 in
.Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 1040 ftz 1040 ftz
50 ft
8 ft.
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH. ACH 50
1 Wholehouse Proposed ACH(50) 000254.
1146.7 62.95 118.39 9,855
.5
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump None
HSPF:8.5
35 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit None
SEER: 15 34.8 kBtu/hr 1044 cfm
0.85. 1
sys#1
6/21/2016 11:18 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
,HOT WATER SYSTEM
# System Type SubType _
_
Location_
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.92 40 gal
50.gal
120 deg
_
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
fF
^
DUCTS
— Supply —
— Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location..
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool,
1
Attic 6 147 ftz
Attic
20 ftz Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
�an
Heating
Jan
Feb. H Fob kiMa r
Mar
W
Apr
Apr I
May rlJul
I'MayMJun rI Jul
Augn Aug
Sep
Sep
Oct:
Nov-
PQ
Dec
Venting
Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78
78
78 78 78.
78 ^
78
80
80
80
80
PM 80
80'
78
78- 78 78
78
78,
78
78
78
78
Cooling (WEH).
AM 78
78
78,
78 78 78
.78
78
78
78
78
78
PM 78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66
66
B6 66 68
68
68
68
68
68
68
PM 68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66
66
66 66 68
68
68
68
68
68
68
PM 68
68
68
68 68 .68
68.
,68
68
68
66
66
FILE Copy
6/21/2016 11:18 AM EnergyGauge® USA - FlaRes2014 Section R405'A.1 Compliant Software. Page 4 of 4
FORM R405-2014
TABLE 402 A.1
AIR BARRIER.AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name:
Street: SPANISH LAKES Permit Officei
City, State, Zip: FT. PIERCE., FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, :Fort Pierce
COMPONENT
CRITERIA
CHECK..
Air barrier and thermal barrier
A continuous airbarrier shall be installed in the building envelope.
Exterior thermal envelope contains.a continuous barrier..
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The.air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop .down stairs or knee wall doors_ to unconditioned
attic -spaces' shall be sealed.
Comers and headers shall be insulated and the junction ofthe:foundation
Walls
and sill plate shall be sealed.
The junction ofthe:top plate.and the top or exterior walls shall be'seale '.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and,
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall,be installed to maintain.permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl. space walls
Where provided- in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth: in unvented crawl spaces shall be covered with a .Class 'I
vapor retarder with overlapping joints:taped:
Shafts, penetrations:
Duch shafts, utility penetrations, and flue shaft -openings to exterior or
unconditioned_space.shall be sealed.
.Narrow cavities
Batts in narrowcavitie&shall be cut to fit, or narrow cavitiesshall be filled
by insulation that.on installation readily conforms to the available cavity
s aces. .
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed. lighting
Recessed light fixtures- installed in the building. thermal envelope shall be
airtight, IC rated, .and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall. extend behind piping and wiring..
Shower/tub on exterior wall
Exterior walls adjacent to showers and.tubs shall; be insulated,and,the air
barrier installed separating them from the showers and tubs.,
Electrical/phone box on
The air barrier shall' be installed behind electrical or communication boxes or
air sealed boxes shall :be installed.:
HVAC register boots
HVAC register boots that penetrate building thermal envelo b
sealed to the. sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. fireplaces shall. have
gasketed doors
6/21/20161.1:18 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1.of 1
i
FORM 'R405-2014
ENERGY PERFORMANCE LEVEL. (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE .INDEX*= 100
The lower the EnergyPerformance Index, the. more efficient the home.
SPANISH LAKES, FT. PIERCE, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
2. Singlefamily. or multiple family
Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1
1312.00 ft2
3. Number of units; if multiple family
1
b. Frame - Wood, Adjacent
R=11:0
400.00 ft2
c. N/A
R=
ft2
4. Number of.Bedrooms
2
d.. N/A
R=
ft2
5. Is this a worst case?
Yes
10. Ceiling Types
Insulation
Area
a. Under. Attic (Vented)
R=30:0
1720.00.ft2
6. Conditioned floor area (ft2)
1720
b. N/A
R=
ft2
7. Windows— Description
Area,
c. N/A
R=
ft2
a. U-Factor. Sgl, .U=0.50
141.25 ft2
11. Ducts
R ft2
SHGC: SHGC=0.25
a. Sup: Attic, Ret: Attic, AH: Attic
S 147
b. U-Factor. N/A
ftz
SHGC:
12. Cooling systems
kBfu/hr
Efriciency
c. U-Factor: N/A
ft2
a. Central Unit,
34.8 SEER:15.00
SHGC:
d. N/A
SHGCor:
13. Heatin9 y s stems
kBtu/hr
Efficiency
cY
Area Weighted Average Overhang Depth:
3.699 ft.
a. Electric Heat Pump
35.0
HSPF:8.50
Area Weighted Average SHGC:
0.250
8. Floor Types
Insulation
Area
14. Hot wat systems
a. Slab -On -Grade Edge.lnsulation
R=0.0
1720.00 ft2
a. Electric
Capt 40'gallonsEF:
b. N/A
R=
ft2
0.92
c. N/A
R=
ft2
b. Conservation.features
None
15: Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building.
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:Date:.
-�
Address of New Home:- 'City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index.'is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at-(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified. Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's: support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/21/201611:18 AM EnergyGauge® USA = FlaRes201.4 Section R405.4.1 Compliant Software P opy
�II�iF