Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLOWER DOOR TEST
V. - ._X.� Date: j 1 0-/ a. Contractor: Job Address: w- Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Permit #: 1712-_ () C, 2y Construction: ()() New Construction — Complete ( ) Existing — After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) = I 77q Test Date: Il -Z 1-i V Volume = f /, 04(. 5- ACH (50) = CFM (50) x 60 / Volume = It. �7:70 Mechanical Ventilation required less than 5 ACH Passing results must be & ACH (50) or less (,) Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: GFA International, Inc. Address: 607 NW Commodity Cove, Port St. Lucie, Florida I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: _&2�z«'? Altjl-c License/Certification #: e s�d0o3� NOV Permitting Department St. Lucie County, FL 0 i Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: f' �i�-! Permit#: / 7i Z— 0470 Lot#: , 4' Contractor: Address: 00,55Z r© Dr Construction: ❑ Post Construction Test ❑ Rough -in Test Test Conditions: Date: j 1-3 0�/ `� Floor Area (ft2): &7 Time: 14v.1 Primary Location of Supply Ductwork "a Indoor Temperature (F): �"'3 Primary Location of Return Ductwork wu•yS Outdoor Temperature (F): b g Total Leakage Test (Outside) Duct Leakage: ❑ Default ❑ Prop, Leak Free Proposed On = • 0'30 Test Pressure: -Z 5� (Pa) Baseline Duct Pressure (optional) (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Qass ❑ Fail Installed Pa 2 S 3 K 11 Total Leakage (cfm): 3 �• / Total Leakage per 100 sgft: 0• OZ o CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft. Testing Company Company Name: GFA International, Inc. Address: 607 NW Commodity Cove, Port St. Lucie, Florida 34986 I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 5t' Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. � �� Signature: /J,, /yam Printed Name: �11tf k a / `(6 wa,i License/Certificate #: REOM1174 goal 4 4 NOV 3 0.2018 Permitting Depart n ent St. Lucie Count,Yi °����