Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL STRUCTURAL COMPONENTSFlorida Building Code Online } Page 1 of 2 BCIS Home I Log In I User Reglstratlon I Hot Topics I Submit surcharge I Stats ti Facts Publications i FBC Staff I BCIS Site Map I Links I Search I FI rid - Product Approval 1 USER: Public User 8 .aran� Product Approval Menu > Product pr Application Search > Application List > Application Detail •1 FL # FL17147-R2 Application Type Revision Code Version 2017 'Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived El Product Manufacturer Huber Engineered Woods LLC Address/Phone/Email 10925 David Taylor Drive Suite 300 Charlotte, NC 28262 (704) 548-5442 kurt.koch@huber.com Authorized Signature Kurt Koch kurt.koch@huber.com Technical Representative Ken W. Hix Address/Phone/Email 1446 Hwy 334 Commerce, GA 30530 (706)336-3041 ken.hix@huber.com Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Walker Campbell 1446 Hwy 334 Commerce, GA 30530 (704) 562-1053 walker.campbell@huber.com Structural Components Products Introduced as a Result of New Technology Evaluation Report from a Product Evaluation Entity IAPMO Uniform Evaluation Services LLC. PFS Corporation 10/01/2018 IAPMO Uniform ES FL17147 R2 COI Certificate of Independence for Evaluation.odf Standard ICC-Evaluation Service AC310 Approved Evaluation Entity Year 2015 .File Copy https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvCo3EapiIlBd... 2/28/2018 Florida Building Code Online Page 2 of 2 Method i Date Submitted 10/20/2017 Date Validated 10/20/2017 Date Pending FBC Approval Date Approved 10/25/2017 Summary of Products FL # I Model, Number or Name Description 17147.1 ZIP System (R) Wall Sheathing ZIP System (R) Wall Sheathing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17147 R2 II ZIP Sheathino Install Manual-2013.Ddf Verified By: ICC Evaluation Service, LLC Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: limited to structural aspects of panel FL17147 R2 AE ESR-1474 (2).Ddf FL17147 R2 AE ESR1474.pdf 17147.2 ZIP System (R) Wall Sheathing Combination Wall Sheathing and Water Resistive Barrier Limits of Use Installation Instructions Approved for use in HVHZ: No FL17147 R2 II FL17147 ZIP Sheathing Install Manual - Approved for use outside HVHZ: Yes 2013.0f Impact Resistant: No Verified By: IAPMO Uniform Evaluation Services LLC. Design Pressure: N/A Created by Independent Third Party: Other: Evaluation Reports FL17147 R2 AE E1553 R0544 Huber Engineered Woods LLC.odf Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FIL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit• secuillt`:mi:TRI https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3EapiIIBd... 2/28/2018 ZIP System®Roof & Wall Sheathing „�ySfem"^ -------------IN.STALLATION-.MAN,UAL__ Contents 02 ZIP System® Sheathing Installation On Roofs. 03 ZIP System"" Tape Installation - Roof Panel Seams 04 ZIP System" Tape Installation - Roof Panel Seams (continued) 05 Roof. Covering Installation Instructions 06 ZIP System® Roof & Wall Sheathing Installation 07 ZIP System"" Tape Installation - Panel Seams ATTENTION: This installation guide is Intended to provide general information for the designer and end user. The following guidelines will help you safely and properly install the ZIP System® Roof & Wall wall sheathing. We urge you, and anyone installing this product, to read these guidelinesan order to minimize any risk of safety hazards and to prevent voiding any applicable warranties. This manual is a general Installation guide and, does not'cover every installation condition. Proper installation shall be deemed to mean the most restrictive requitement specfled by Huber. Engineered Woods (HEW), local building code, engineer or architect of record or other authority having jurisdiction. You are fully and solely responsible for all safety requirements and code compliance. For additional Information contact Huber Engineered Woods LLC. ZIP System® Roof & Wall SheathingSafety Guidelines - Follow all OSHA regulations and any other safety guidelines and safety ,practices during installation and construction. Use approved safety belts and/or harnesses or otherfall protection equipment. Install ZIP System panels and.tape only In dry conditions and on dry surfaces. Do not install In rain, snow, frost or other slippery conditions. - . Wear rubber -soled or other high -traction footwear while installing ZIP System 'sheathing in'a roof application. Do not wear footwear with worn soles or heels. Ensure the roofing surface is free from oil, chemicals; sawdust, dirt, tools, electric cords, air hoses, clothing and anything• else that might create a tripping hazard. Install temporary toe boards'along the ZIP System sheathing roof surface. What Is ZIP System? Roof & Walt Sheathing? ZIP System Roof & Wall sheathing is code -recognized as a wood structural panel, roofing underlayment (IMES ESR-1473), water -resistive barrier and air barrier (IMES ESR-1474). ZIP System Roof & Wall sheathing has a built-in moisture barrier that lets you say good-bye to building paper or housewrap on the walls and felt paper on the roof' Simply install the panels, tape the seams, and you have a structural wall sheathing, water - resistive barrier and air barrier or a structural roof sheathing and roofing underlayment.all from one product. FASTER. TIGHTER. ENERGY EFFICIENT. 08 ZIP Systems Roof & Wall Sheathing - Window Installation Flanged Windows & Brick Mould Windows 09 ZIP System® Roof & Wall Sheathing - Window Installation Brick Mould Windows (continued) 10 ZIP System® Roof & Wall Sheathing - Penetration Openings 1.1 ZIP System® Roof & Wall Sheathing Installation Details 12 ZIP System® Roof &.Wall Sheathing Installation Details (continued) ZIP System Roof & Wall sheathing can be used with a range of exterior claddings and roof coverings. Approved wall coverings include brick, vinyl, stone, wood fiber cement; wood and cedar shakes, traditional hard coat stucco and specified drainable EIFS applications, however it is not recommended for use with adhesively attached EIFS. Approved roof coverings include asphalt -fiberglass shingles, metal tiles and panels, day and concrete tiles, slate and slate -type shingles and. wood shakes and shingles. Follow all cladding.and roof covering manufacturer's installation instructions. ZIP System Roof & Wall sheathing can be used on buildings of Type III (Roof Applications ONLY) and Type V construction and construction. permitted under the IRC. ZIP.SysterriO Roof & Wall Sheathing Includes: - ZIP Systemsheathing panels with built-in moisture barrier with preprinted fastening and. tape guldes ZIP Systern tape Storage and Handling - . Set panel.stack on three supports (stickers) to keep off the ground. outdoors, cover panels loosely with waterproof protective material. Anchor covers on top of the stack, but keep away from sides and bottom to assure good air circulation. In high moisture environments, cut banding on the panel stack to prevent edge damage. ZIP System Roof & Wall Sheathing Notes and Limitations: Do not use on roofs with slopes less than 2112. Do not use abutted against general stone or masonry without providing a minimum of a 1/2" gap. Do not install ZIP System tape in temperatures less than 20" F ZIP System.products are not recommended for manufactured housing applications that are built under a federal building code administered by the U.S. Department of Housing and Urban Development (HUD). Do not use panel edge clips (H-Clips) with ZIP System Roof. & Wall sheathing without expressed written approval from Huber Engineered Woods." Do not use ZIP System tape to permanently seal around circular roof projections (plumbing vents, pipes, curved walls, etc.) Contents (continued) Wall Coverings - ZIP System Roof & Wall sheathing should be covered with the finished roof covering or exterior cladding within 180 days of installation. Finished roof and exterior cladding products should be installed per the manufacturer's installation Instructions. Per the recommendation of the Western Red Cedar Lumber Association and the U.S. Forest Products Laboratory, wood siding should be primed. before installation. When original roofing orcladclings are removed and replaced on existing ZIP System sheathing, the roof or walhshould be covered with an additional roofing upderlayment or water resistive -bander prior to installation of the new finished roofing or cladding. Note: In cladding systems requiring multiple layers of water-reslstive barriers, like traditional hard -coat stucco, ZIP System sheathing is intended only to replace the first layer. Wet Blown Cellulose. Insulation - In addition to-foliowing manufacturer installation instructions, we recommend a ma)dmum moisture content of the cellulose of less than 25'/o measured. at the inside surface of the ZIP System panel before closing the wall cavity. Secondary Coatings Do not apply•seoondary coatings or treatments to ZIP System Roof & Wall sheathing panels. with the exception of the following: HEW approved fire resistant coatings: Fire resistant coatings must be tested and approved by HEW for use with ZIP System panels. - Field applied water-soluble borate insecticide or fungicide treatments applied to the non overlay side of the: panel. See technical tip, "Termite Treatments on ZIP System Roof & Wall Sheathing," on zipsystem:com for more information. Permeable laminated radiant barrier foil or paint. For a radiant barrier foil or coating to: be considered permeable, it must have an applied permeance of five perms or greater as tested by the ASTM E 96 wet cup standard. For a radiant foil, the permeance evaluation would include any adhesive and/or backer used to laminate afoil. For a radiant paint/coating, the permeabce evaluation should be conducted at the applied thickness of the paint/coating. ZIP System Roof and Wall sheathing replaces only the first layer in muftFunderlaymem systems, Uge:support is not required by code with 1/2 (32116 span rated) and 5B (40I20 span rated). perlormance category sheathing if.the framing does not exceed 24" oc. and the total toad does not acaed 93 psf for 1/2 and Its pd far y8 performance categories. Thls is based on 11180 deflection criteriafor total load. ZIP System* Roof & Wall Sheathing Installation Manual ZIP System® Sheathing Installation on Roofs Overview: ZIP System Roof & Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape. ZIP Systemm Roof & Wall. Sheathing panels should be fully installed before the seam sealing tape is applied. In general, the ZIP System roof sheathing panels should be installed from the lowest point on the roof to the highest. It is at the discretion of the installer whether to apply tape from the top down or from the bottom up. However, working from the highest sections of the roof and working down will minimize foot, traffic on the tape. The following installation steps are presented as guidelines and a general outline of the installation process. These are manufacturer installation recommendations— please visit zipsystem.com.for a library of flashing and installation details. You are fully and solely responsible for all safety requirements, Good construction and safety practices should be followed at all times. Step 1. Ensure that the panel surface is dry and clean of any nails, sawdust, or other debris or protrusions prior to installing or walking on the panels. After ensuring compliance with all OSHA and local code safety guidelines, install ZIP System sheathing panels with the moisture barrier surface facing outside. The long edge (8) should be oriented perpendicular to the -framing members, and panels should be installed with the 4' edge seams staggered a minimum of 24'. 1/,8'spacing between square edges of all adjacent panels is recommended, in accordancewith industry standards for wood sheathing. (Tongue & Groove panels are designed to self -spade and do not require manual spacing on the 8' edges.) Step 2.. Ensure that.ZlP System panels span at least three framing members and a framing member supports the entire 4' edge of the panels. Fasten the ZIP System Roof & Wall sheathing panel to the framing members with code approved fasteners spaced at the appropriate edge and intermediate spacing.. It is the responsibility of the general contractorto verify -proper fastener type and spacing priorto installation. Apply the fasteners 3/8" from the panel ends and comers. An ideal Installation would be where fastener heads are flush with the panel surface. However, due to variations in materials and limitations on equipment, this may be difficult to achieve in some situations. It is not required to tape over overdriven fastener's unless the fastener head creates a hole through the entire panel thickness. Please see the technical tip,'OverddVen Fasteners in ZIP System Roof and Wall Sheathing," for more information. Step & Install temporary toe boards as necessary when applying the ZIP System sheathing panels up the slope of the roof planes. . 8' Panel Edges 1/a' s The unique edge. profile is designed to accorrirriodate incremental panel expansion and; does not require manual gapping along the 8' edges. 4' Panel Edges 118, Maintain 1/8' space where 4' edges meet. Unique edge profile is on 8' edges only. 03 - : . ZIP SystemTM Tape Installation - Roof Panel Seams Apply ZIP System tape after all ZIP System Roof & Wall sheathing panels are fully fastened to roof -framing members. Only ZIP System tape should be used to seal the seams of ZIP System panels.. Ensure that the panel surfaces are dry and free of any nails, sawdust and other debris, or protrusions. Avoid. stepping • on tape in high temperature environments. ZIP System tape is a contact tape that requires pressure for an adequate seal. Step 1. Apply ZIP System tape to every vertical and horizontal panel seam it is at the discretion of the installer whether to applytape from the top down or from the bottom up. However, working from the highest sections of the roof and working down will minirniie foot traffic on the tape. Ensure that the tape is centered over the seam within +/- 1/2" to provide adequate coverage and to ensure that wrinkles in the tape are minimized. Ensure that tape lengths are continuous across the 8' horizontal edge of the panels. If splices are unavoidable, create an overlapping splice Of at least 3. Apply'moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape. Use ZIP System tape gun or tape roller to apply pressure to the tape and smooth out any wrinkles. Take special care to remove any voids and/or trapped air at splice areas.and T-joints. Step 2. For valley areas of fraining, we recommend you use 6'wideZIP System tape. This tape Is wider than panel seam tape and is designed to give you optimal protection in valley areas. Starting from the bottom and working your way up, apply one continuous piece of 6" tape.so that the center of the tape is over the valley. seam. Use the. tape gun or tape.roller to apply pressure to the tape to ensure proper contact with the panel and to eliminate any wrinkles that might have occurred in the tape. Take special care to seat tape completely into the valley. Note: - It is Important to pay extra attention to valley taping as water is directed toward the valleys during rain events. Self -adhering Ice and water barriers may be required by code. ZIP System tape is not considered a replacement for self -adhering fee and water barriers. Therefore, when self -adhering ice and water barriers are required, they should be installed in addition to ZIP System tape. I E 3" overlap Second Tape Piece ZIP System° Roof & Wall Sheathing Installation Manual MI ZIP System'" Tape Installation - Roof Panel Seams (continued) Step 3. If 6" ZIP'System tape is not available, use two continuous pieces of 3.75" ZIP System panel seam tape over the entire length of the valley seam, overlapping the pieces on the valley seam by at least 1". Starting from the bottom, instail the first piece of tape overlapping the . valley seam by at least T". Use the tape gun or tape -roller to apply pressureto the tape to ensure proper contact with the panel and to eliminate any wrinkles that might have occurred in the tape. Apply the second piece of tape, overlapping the first piece in the valley seam by V. Repeat use of the tape gun or roller to make sure the tape is adequately adhered and tightly pressed into the valley seam. Note: It is important to pay extra attention to valley taping'as water is directed toward the valleys during,rain events. - Self -adhering Ice and water barriers may be required by code. ZIP System tape Is not considered a replacement for self -adhering Ice and water barriers. Therefore, when self -adhering Ice and water barriers are required, they should be installed in addition to ZIP System tape. Step 4. To provide temporary weather protection to roof/wall intersections of dormers or other wood -sheathed projections, apply 2" of the tape width up the vertical projection from where it intersects with the roof. The'remaining tape width can be adhered to the ZIP System roof sheathing panels. Use the tape gun or tape roller to apply pressure to the tape and smooth out any wrinkles. Step 5. Install ZIP System tape over hips and ridges by centering the tape over the peak seam. •Apply tape in sufficient length to completely extend the length of the hip or ridge. Starting from the lowest. point of the hip and working up, press tape into place keeping tape centered over the hip. Apply moderate pressure onto the surface of the tape to ensure a secure bond between.the panel and'the tape. Cut ridge tape. as required for ventilation prior to installing ridge vent. Step S. Tape overtbe.board nail holes once the toe boards are removed, working from the highest toe boards to the lowest. First piece of tape V overlap Second piece of tape Roof Covering Installation Instructions ZIP System. Roof & Wall sheathing is a code recognized sheathing and underlayment and is approved for use with the following roof coverings: - Asphalt -fiberglass. Shingles - Metal Roofs (shingles and panels) - Clay Tile Concrete Tile - Slate and Slate -type Shingles. Wood Shingles Wood Shakes When installing roof coverings, follow applicable codes and manufacturer's suggested instructions. Some roof coverings require a slip -sheet in addition to conventional underlayment. Where slip -sheets are required, they should be. installed over ZIP Systemsheathing panels. Note: Visit zipsystem.com for updates and installation details. Asphalt-ffbergless: Shingles Apply asphalt shingles directly to.ZIP System sheathing. For roofs with a slope of 2/12 or greater but less than 4/12, additional underlayment maybe required. Install asphait4iberglass shingles according to applicable codes and manufacturer's installation instructions. Metal Roof Coverings Metal roof coverings may be applied to ZIP System sheathing provided that the roof covering manufacturer's installation instructions and applicable codes are followed. Fasteners used to secure the ZIP System Roof & Wall sheathing panels to supporting framing.must be compatible With the specific.metal roof covering used. Galvanized fasteners shall be used with galvanized roof coverings, aluminum -zinc coated fasteners, shall be used with aluminum -zinc coated root coverings and 300 series stainless steel fasteners shall'be used with copper roofs. Stainless steel fasteners are acceptable with all metal roof types. In addition, metal roof flashing shall also be made of a material compatible with the specific metal roof covering used. Apply metal shingles on roofs with slopes of 3/12,or greater.. Clay and Concrete Tile,Roof Coverings ZIP System Roof & Wall sheathing is Intended to replace the first layer in a two -layer or multi -layer underlayment system. When installing clay or concrete tile roof coverings, follow the installation recommendations. of FRSA/rRI 07320. install tile.roofs according to applicable codes and manufacturer's installation instructions. Slate and Sfate-type Shingles Apply slate and slate -type shingles on roofs with slopes of 4/12 or greater. Install slate and slate -type shingles according to applicable codes and rnanufacturees installation instructions. Wood Shingles ZIP System Roof & Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of underlayment may be required by coda depending on the local climate. Apply wood shingles on roofs with slopes of 3112 or greater. Install wood shingles according to applicable: codes and manufacturer's installation instructions. Wood Shakes ZIP System Roof & Wail sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of undedayment may be required by code depending on the local climate. ZIP System roof sheathing is not to be construed as a replacement for lnterlayment: Apply wood shakes on roofs with -slopes of 4/12 or greater. Install wood shakes according to applicable codes and manufacturer's installation instructions. ZIP System0 Roof & Wall Sheathing Installation Manual ZIP System® Sheathing Installation on Walls Overview: ZIP System Roof & Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape. ZIP System® Roof & Wall Sheathing panels should be fully installed before the seam sealing tape is applied. The following installation steps are presented as a general outline of the installation process. These are manufacturer installation recommendations —please visit zipsystem.com for a library of flashing and installation details. You are fully and solely responsible for all safety requirements. Good construction and safety practices should be followed at all times. Step 1. Install ZIP .System Roof & Wall sheathing panels positioned With the water -resistive barrier facing outside. The panels may be installed with the long side of the panel oriented either horizontally or vertically to the framing members. Walls that are designed to resist lateral shear forces and sheathed with wood structural panels typically require solid framing or blocking behind all panel edges. If oriented horizontally, block horizontal joints if wall is designed for bracing, or as a shear wall. 1/8' spacing between.square edges of all adjacent panels is recommended in accordance with industry standards for wood sheathing installation. 8' Panel Edges Panel Edges 4" Panel. Edges II I� II 3 4 The unique edge profile:is ' Maintain 118" space where Maintain 118" space designed to accommodate 8' panel edges meat*. where9' edges meet incremental panel panel edges: Unique edge Unique edge profile is on expansion and does riot profile does not provide 8' edges only,• require manual gapping the full'116' recommended along the B' edges." space in this s luation.• Step 2: Fasten the panels to the framing members -with code approved fasteners. Space fasteners 6" o.c. along supported edges and 12" o.c. at Intermediate supports, unless otherwise specified by local code or the designer of record. It is the responsibility of the general contractor to verify proper fastener"type and spacing prior to installation. Apply the fasteners 3/8" from the ends and corners. An'ideal installation would be where fastener, heads are flush with the panel surface. However, due to variations in materials and limitations on equipment, this may be difficult to achieve in some situations. It. is not required to tape over overdriven fasteners unless the fastener head creates a hole through the entire panel thickness. Please see the technical tip "Overdriven Fasteners in Zip System Roof and Wall Sheathing," on zipsystem.com for more information. __ 07__ ZIP System'" Tape. Installation_- Wall Panel Seams Apply ZIP System tape after all ZIP System Roof & Wall sheathing panels are fully fastened to wail -framing members. Only ZIP System tape should be used to seal the seams of ZIP System panels. Ensure that the panel surface is dry and free of sawdust and dirt prior to taping. ZIP System tape is a contact tape that requires pressure for an adequate seal. Step 1. Tape all seams using ZIP System tape. Ensure that the tape is centered over the seam within +/- 1/2' to provide adequate coverage and that wrinkles in tape are minimal. Use the ZIP System'tape gun or roller to apply pressure to the tape and smooth out any wrinkles. Step 2. Wherever tape splices occur at a horizontal or vertical seam, create an. overlapping splice of at least 3 At T-joints, the tape pieces should overlap by at least 1". Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape. Use the ZIP System tape gun or roller to apply pressure to the tape and smooth out any wrinkles. Take special.care to remove any voids and/or trapped air at splice areas and T-joints. Step 3. Tape inside and outside comer seams. Note: Tape over any areas of the panel or tape that are damaged during construction. ZIP System® Roof & Wall Sheathing Installation.Manual ZIPS stem - Window Installation 01§CLAIMER The following steps represent a general overview for the proper installation of window flashing. Please deferto/consult Y the inslallatlon instructions of your window manufacturer as well as code requirements in.your lurisrrction for full Inslallatim details. Flanged Windows 1. Fasten the ZIP System sheathing to the wood frame and install. ZIP System tape to all wall panel seams,, as detailed in sections 02 and 03. f 2. ZIP System tape may be used as pan flashing if installed in accordance with flanged window installation details posted on zipsystem.com. Other adhesive -based flashing tapes (must meet [CC -ES Acceptance Criteria for Flashing Materials (AC148)) maybe used as pan flashing if installed per ASTM, 2112-07. Apply the flashing to cover the bottom of the opening, overhanging onto the sheathing by at least 2" and extending a minimum of 6" up each jamb. 3. Apply sealant around inside face of mounting flange. Sealant must be gapped at the sill to permit drainage. I nstall and level window per manufacturer's installation instructions. Verify sealant compatibility with window manufacturer. When using ZIP System tape as pan flashing, butyl, 100% silicone or polyurethane sealants are acceptable. Do not use latex or other water - based sealants.. 4. Out two pieces of ZIP System tape or another adhesive -backed flashing tape (must meet ICC- ES Acceptance Criteria for Flashing. Materials (AC148)) and apply to each of the window jamb. sill flashing. Once the tape Is, in place, use the tape gun or roller to seal the flashing to the sheathing. 5. ;Cut a length of ZIP System tape or another adhesive -backed flashing tape (must meet !CC - ES Acceptance Criteria. for Flashing Materials (AC148)) and apply to the header, .ensuring that the flashing overlaps the jamb flashings.' 1 Once the tape is in place, use the tape gun or roller to seal the flashing tothe sheathing. TO NOT tape bottom flange. 6. From the interior, apply low-pressure polyurethane foam (for windows) between the rough opening and the window frame. (Caulk sealant compatible with the sill flashing may be used at the sill if the opening between. the sill flashing and window is too narrow to allow the use of low-pressure polyurethane foam.), t When using ZIP System tape, butyl, 100% „ s silicone or polyurethane sealants are acceptable. - Do not use latex sealants with ZIP System tape. If using another flashing tape, follow 'the flashing manufacturer's recommendation in selecting a sealant compatible with that flashing. Bride Mould Windows 1. Fasten the.ZIP System sheathing to the wood frame and install ZIP System tape to all wall panel seams, as detailed in sections .02 and 03. i r 2. If recommended by the window manufacturer, cut a strip of wood to function as aback dam at the sill. The wood strip should have rough opening and a height and width of at least 112". Position the block at the inside edge of the window frame. ZIP System -Window Installation Brick Mould Windows (continued) 3. ZIP System tape may be used as pan flashing if installed in accordance with brick mould window Installation details posted on zipsystem.com. Other adhesive -based flashing tapes (must meet ICC-ES Acceptance Criteria for Flashing Materials (AC148)) maybe used as pan flashing if installed per ASTM 2112-07. Apply the flashing to cover the bottom of the opening, overhanging onto the sheathing by at Least 2° and extending -a minimum of 6" up each jamb. 4. Forvertical jambs, cut ZIP System tape or another adhesive -backed flashing tape (must meet ICC- ES Acceptance Criteria for Flashing Materials (AC148)) and apply to each of the window jambs. Ensure that they cover the, entire inside of the rough opening as well as overlap onto the sheathing by at least 2". Flashing shall also extend above the rough opening, such that It will project 1" beyond the exterior trim of the window. Once the tape is in place, use the tape gun or roller to'seal the. flashing to the sheathing. S: Apply sealant to jambs and header allowing for drainage at the sill in accordance with window manufacturer's installation instructions. When using ZIP System tape, use a butyl, polyurethane or 100 o silicone sealant. Do not use .latex or other water -based sealants with ZIP System tape: When using another flashing tape, follow the flashing manufac-turer's recommendations in selecting a sealant compatible. With that flashing. 6. Install and level window per manufacturer's installation instructions. DISCLAIMER. The following steps represent ageneral overview for the proper installation of window flashing. Please defer lo/cansult the installation instructions of your wirrdow manufacturer as well as code requirements in your jurisdiction forful Installation details. 7. Cut a piece of rigid head flashing so that when installed, it is flush with the edges of the exterior moulding of the window. Apply a bead of sealant to the back and bottom surface of the rigid head flashing. Use sealant recommended by the flashing manufacturer, 8. Secure the rigid head flashing to ZIP System wall sheathing. 9. Cut a length of ZIP System tape or.another adhesive -backed. flashing tape (must meet ICC-ES Acceptance Criteria for Flashing Materials (AC148)) and apply to the rigid head flashing, ensuring that the adhesive -backed flashing overlaps the jamb flashings. Once the tape is in place, use the tape gun or roller to seal the flashing to the sheathing. 10.. From the interior, apply low-pressure polyurethane foam (for windows) between the rough opening and the window frame. (Caulk sealant compatible with the sill flashing may be used at the sill if the opening x between the sill flashing and window is too narrow t to aloes the use of low-pressure polyurethane .toam ) When using ZIP System tape, butyl,100% silicone ' t; or polyurethane sealants are acceptable. Do not ' use latex or other water -based sealants: with. ZIP System tape. If using another flashing tape, follow the flashing manufacturer's recommendation in selecting a sealant compatible with that flashing. ZIP System? Roof & Wall Sheathing Installation Manual ZIP System - Penetration Openings DISCLAIMER: The following steps represent a general overview for the proper installation of penetration flashing. Please defer tolconsult your codeTequiremenis in yourjudsdiction for full installation details. WALL ASSEMBLY �l ZIPSYSTEmWALLSwwKNG JF //�� wwoGR LT.oAAtrµsTDOs OVERLAPTAPEA MINVAUMOF WNCHATAIIT.JOIRTs- FASTENS SYSTE"WALL SHEATHING AS REOUNIED BY DesIGNeR.oFaewnP Da LOCPL WALL ASSEMBLY ZIP SYSTEM® WALL SHEATHING WOOD OR LT, GA. METAL STUDS IIS-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED P90FILED EDGES — INSTALLZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING (MUST MEET ACMS) IN SEQUENCE FROM BOTTOM, SIDES, THEN TOP TO ENSURE SHINGLE LAP OF ADHESIVE BACKED FLASHING ZIP SYSTEM® TAPE (INSTALLED OVER ALLJOINTSIN ZIP SYSTEMS WALL SHEATHING), OVERLAP TAPE A MINIMUM OF 1-INCH ATALL TJOINTS USE. FLANGED ELECTRICAL BOXES OR MEMBRANE FLASHING TOPROVIDE .FLANGES FOR ELECTRICAL BOXES WALLAGSEMDLYY 21PSYSTEM9 WAL.SWATHING WOODOR LT. GA METµ STUDS t\ MUNCH GAP RECOMMENDED AT PANEL EDGES UNLESS WvsuwsY1TEM waATA EXTERIOR CORNERS FASTMAPSYSTFMAWALL SNEATHNGAS REQUIRED BV DESIGNER-0kREmRD oa IOGLL au=NG CODE WALLASSEMBLY ZIP SYSTEMS WALL SHEATHING WOOD OR LT. GA. METAL STUDS 118-INCH GAP RECOMMENDED AT PANEL EDGES. UNLESS OTHERWISE.PROVIDED BY MACHINEDPROFILED EDGES — 1 INSTALL ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING (MUST MEET AC148) IN SEQUENCE FROM aOT70M, SIDES. THEN TOP TO ENSURE SHINGLE LAP OF ADHESIVE BACKED FLASHING ZIP SYSTEMS TAPE (INSTALLED OVER ALL JOINTS IN ZIP SYSTEMS WALLSHEATHING), OVERLAP TAPE A MINIMUM OF I•INCH AT ALL TJOINTS \ _QSE.FLANGED VENT HOODS 11 ZIP System Sheathing Installation Details on Walls - visit zipsystem.com for more details. WALL ASSEMBLY VINYLNYOODlFIBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) ZIP SYSTEM® WALL SHEATHING WOOD OR LT. GA METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH.ZIP SYSTEM® TAPE OR.ADHESIVE BACKED FLASHING. (MUSTMEETAC148)- CODE APPROVED FLASHING WALLASSEMBLY VRNYUW000IRBER CEMENT q[MNG (INSTALLED IH AOCORUANCE WITH CLADOINGMANUFACTURER3 INSTALLATION RECQMNENDATIOL S) WOODRLT.WJ& GALLETAL STUDS WOOD OR LT. GA METAL STUDS 1/8•INCHW RECOMMEWM AT PANEL EDGES UNLESS OTHRWISE. PROVIDED BY MACEHMEOPRORLED EDGES ZIP SYSTEMA)TAPE'(IASTALLED OVER ALL JOINTS IN AP SYSTEMS WALL SHEATFING). OVERLAP TAPE A.MINMUM OF 14 NCH AT ALLT40INTS VS -INCH GAP. RECOMMENDED AT PANELEDGESUNLESS OTHERV/ISE PROVIDED BY MACHINEO PROPLLED EDGES FASTEN ZIP GYSTEMS WALL SHEATHWGAS REO IRED BY _ ESIGNEP OFRECDRD.OR LOCAL. WALL ASSEMBLY BRICK VENEER AIR SPACE,(AS PRESCRIBED BY LOCAL BUILDING CODE) ZIRSYSTEM® WALL SHEATHING WOOD OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED WITH,ZIP.SYSTEMO TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) CODE APPROVED BASE .FLASHING -� WEEP HOLES (AS PRESCRIBED BY LOCAL BUILDING CODE) - WALL ASSEMBLY BRICKVENEER AIR SP,ACE.(AS PRESCRIBED BY LOCAL BUILDING CODE) ZIP SYSTEMO WALL SHEATHING WOOD OH LT. OA. METAL BTUDS - 1M ANCH GAP RECOMMENDED AT PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES LP SYSTEMS TAPE (INSTALLED OVER ALL JOINTS IN ZIP Symms WALL SHEATHING).\\ 000 OVFRLAP TAPEA MWIMLIMOF 1-INCH AT ALLTJOINTS 1184NCH GAP RECOMMENDED AT \ PANEL EDGES UNLESS OTHERWISE PROVIDED BY MACHINED PROFILED EDGES �. FASTEN ZIPSYSTEMS WALL SHEATHING AS REQUIRED BY DESIGNER-0E-RECORD'OR LOCAL "" - - --- --- - - -- ' BUILDINGCODE Note: For optimal air leakage reduction, all untaped edges of the panels can be caulked, gasketed or sealed with a weather stripping material. ZIP System® Roof & Wall Sheathing Installation .Manual WALL BEYOND BACKDAM PER WINDOW MANUFACTURER'S INSTALLATION. RECOMMENDATIONS INSTALL CODE -RECOGNIZED SILUPAN FLASHING IN ROUGH OPENING PRIOR TO WINDOW INSTALLATION. TOP EDGE OF FLASHING TAPED WITH ZIP SYSTEM® TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) WEEPS (AS PRESCRIBED BY LOCAL BUILDING CODE) — CODE APPROVED FLASHING WALL ASSEMBLY BRICK VENEER AIRSPACE (AS PRESCRIBED BY LOCAL BUILDING CODE) ZIP SYSTEM® WALL SHEATHING WOOD OR LT. GA. METAL STUDS 12 ZIP System Sheathing Installation Details on Walls (continued) WALL ASSEMBLY BRICK VENEER AIR SPACE (AS PRESCRIBED BY LOCAL BUILDING CODE) ZIP SYSTEM@ WALL SHEATHING WOOD OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED WITH ZIP SYSTEM® TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) CODE APPROVED FLASHING WEEPS (AS PRESCRIBED BY LOCAL BUILDING CODE) — STEEL LINTEL INSTALL WINDOW IN ACCORDANCE WITH DETAILS 24A-24D OR 25A-25D. WALL BEYOND WALL.ASSEMBLY CODE APPROVED FLASHING Note: For optimal air leakage reduction, all untaped edges of the panels can be caulked, gasketed or sealed with a weather stripping material. Z PI SYSTEMS SHEATHING WITH HARD COAT.ST000O AT H-2* BLOCKFOUNDATION WALL-OPTIONA TRADITIONAL HARD -COAT STUCCO INSTALLED IN ACCORDANCE WITH THE LATH MANUFACTURER'S OR THE PORTLAND CEMENT ASSC. (PCA) RECOMMENDATIONS WITH THE MOST ONE LAYER OF WATER -RESISTIVE RESTRICTIVE CONTROLLUNG. VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO GRADE D BUILDING PAPER. a� ZIP SYSTEM® SHEATHING* TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING • , , .,. WITH ZIP SYSTEM® TAPE OR : .• ADHESIVE BACKED FLASHING. .t (MUST MEET AAMA 711 OR AC148) WOOD OR LT. GA. METAL STUDS ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT (ZIP SYSTEM TAPE MAY BE USED AS �THE/B]RIDGE FLASHING) - CODE -APPROVED �Q WEEP SCREED AT BASE OF WALL - VERTICAL AND HORIZONTAL CONTROL JOINTS AS NEEDED. DESIGNER -OF -RECORD TO SPECIFY TYPE AND LOCATION. MASONRY BLOCK WALL -ZIP SYSTEM® SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO -LAYER UNDERLAYMENT SYSTEM. SW im Sales Office:10925 David Taylor Drive Suite 300 - Charlotte, NC 28262 SHEATHING & TAPE Telephone: 800.933.9220 - mw4.zipsystem.com se construction details are provided to assist in the installation of DRAWING NOT TO SCALE �gV��ENGINEERED ` WOODS may not apply to every sauation. manuracturer accepts no responsibility or liability for the use of these or other construction details. ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT BLOCK FOUNDATION WALL- OPTION A WALL ASSEMBLY TRADITIONAL HARD -COAT STUCCO METAL LATH ONE LAYER WATER-RES. BARRIER ZIP SYSTEM® SHEATHING' WOOD OR LT. GA. METAL STUDS TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP SYSTEM@ TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC148) CODE -APPROVED WEEP SCREED AT BASE OF WALL ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER \ TRANSITION JOINT (ZIP SYSTEM TAPE MAY BE USED AS THE BRIDGE 1 FLASHING) MASONRY BLOCK WALL LATH TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP SYSTEM@ TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC148) TRADITIONAL HARD -COAT STUCCO INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S OR THE PORTLAND CEMENT ASSC. (PCA) RECOMMENDATIONS WITH THE MOST RESTRICTIVE CONTROLLLING. ONE LAYER OF WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A' PERFORMANCE AT LEAST EQUIVALENT TO GRADE D BUILDING PAPER. CODE -APPROVED WEEP SCREED AT BASE OF WALL ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT (ZIP SYSTEM TAPE MAY BE USED AS THE BRIDGE FLASHING) MASONRY BLOCK WALL HM2 F� 'ZIP SYSTEM@ SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO -LAYER UNDERLAYMENTu %#qT TO SCALE o Sales Office:10925 David Taylor Drive ft"q ENGINEERED c ystem Suite 300 - Charlotte NC 28262 SHEATHING 8 TAPE WOODS o Telephone: 800.933.9220 - www.zipsystem.com These construction details are provided to assist In the installation of ZIP System® product(s) and may not apply to every situation. Manutacturer accepts no responsibility or liability for the use of these or other construction details.