B`LOWER DOOR TEST FORM T �d� E��u��� RECEIVED
� �u
House Infiltration Test Certification
Date: `L ( 13
Contractor: -- - -- ---
Cob Address: L
Construction:
Prescriptive and Performance Method
pQ ) Permit #: t I
DH I (�tdlny�d� DZJ2.Io
I a: 9 1 Jet foe, r e
New Construction Complete
M Ch-+ L. L C
F1 1 3. 2019
Permitting Department
St. Lucie County
( ) Existing — After Addition
House Infiltration Test exults SLC Climate Zone 2
CFM (50) = 9 9 Test Date:
Volume = I CL+-1+0
ACH (50) = CFM (50) x 50 / Volume = Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less Pass ( j Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope
FBC, Residential,
Where the air infiltration rate of a dwelling unit Is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.L2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name.- I-M-Duct Services Address: 1915 Rio Vista Drive, Ft Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Secitiork 114PM.L2 Climate Zone 2.
Signature: ^kW_
Printed Name: Martin 19ein
License/Certification #: 5061633