Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST FORM 2-13-19Planning & Development Services Building & Code Regulation Division FILE COPY e 230o Virginia Ave, Rm 201 ' Fort Pierce, Fl. 34982 Phone: 772-462-2165 Fax: 772-462-643CAN NED BY B`LOWER DOOR TEST FORM T �d� E��u��� RECEIVED � �u House Infiltration Test Certification Date: `L ( 13 Contractor: -- - -- --- Cob Address: L Construction: Prescriptive and Performance Method pQ ) Permit #: t I DH I (�tdlny�d� DZJ2.Io I a: 9 1 Jet foe, r e New Construction Complete M Ch-+ L. L C F1 1 3. 2019 Permitting Department St. Lucie County ( ) Existing — After Addition House Infiltration Test exults SLC Climate Zone 2 CFM (50) = 9 9 Test Date: Volume = I CL+-1+0 ACH (50) = CFM (50) x 50 / Volume = Mechanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less Pass ( j Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope FBC, Residential, Where the air infiltration rate of a dwelling unit Is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.L2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name.- I-M-Duct Services Address: 1915 Rio Vista Drive, Ft Pierce, FL 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Secitiork 114PM.L2 Climate Zone 2. Signature: ^kW_ Printed Name: Martin 19ein License/Certification #: 5061633 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 Maltp, NY 12020 (877)-274-1274 www-bpLorg BPI Martin l9ein SK CSMM8MVDC-FMDMMTMNS=EXPIRATION DATES)