HomeMy WebLinkAboutENERGY EFFICIENCY CODE 6-5-17SCANNED
FORM R405-2014 ST L`[lr BY
f 011 Wf)"
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LICAUSI RESIDENCE
Builder Name:
Street: 4905 RIVER PLACE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: STEVE AND MARILYN LICAUSI
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2196.1 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1889.00 ft2
b. Frame - Wood, Adjacent
11.0 307.17 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
i ft2
5. Is this a worst case? No
10. Ceiling Types (2070.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
1 2070.00 ft2
6. Conditioned floor area above grade (ft2) 2070
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(237.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 140
a. U-Factor: Sgl, 1 175.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 62.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
30.0 SEER:16.00
c. 'U-Factor: N/A ft2
b. Central Unit
6.0 SEER:33.10
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Heat Pump
17.0 HSPF:13.50
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.263
14. Hot water systems
8. Floor Types (2070.0 sgft.) Insulation Area
a. Electric Tankless
Cap: 1 gallonsEF:
a. Slab -On -Grade Edge Insulation 12070.00 ft2
b. Conservation features
0.980
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 63.41
Glass/Floor Area: 0.114
PASS
Total Baseline Loads: 71.09
I hereby certify that the plans and specifications covered by
Review of the plans and
Sr'4T�p
this calculation are in compliance with the Florida Energy
specifications covered by this
O�'Tii.E
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: -
this building will be inspected for
gip,
compliance with Section 553.908
* °'
I hereby certify that this b I�g,;alde* sin compliance
Florida Statutes.
with the Florida Energy
G'Otj '1�
WE
OWNER/AGE T•
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
6/5/2017 11:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title:
LICAUSI RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2070
Lot #
Owner:
STEVE AND MARILYN
LICAU
Total Stories:
1
Block/SubDMsion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
4905 RIVER PLACE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
Zone
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
MAIN
1837
18263.7
2
WORKSHOP
233
2353.3
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
M TOILET
24
242.4 No
0
1
Yes
Yes
Yes
2
M BATH
72
727.2 No
0
1
Yes
Yes
Yes
3
M WIC
81
818.1 No
0
1
Yes
Yes
Yes
4
MASTER BEDROO
269
2716.9 No
0
1
1
Yes
Yes
Yes
5
M CLST
18
181.8 No
0
1
No
Yes
Yes
6
CAFE
212
2141.2 No
0
1
Yes
Yes
Yes
7
FAMILY
265
2676.5 No
0
1
Yes
Yes
Yes
8
KITCHEN
218
2201.8 Yes
0
1
No
Yes
Yes
9
BEDROOM 3
174
1757.4 No
0
1
1
Yes
Yes
Yes
10
ENTRY
45
454.5 No
0
1
Yes
Yes
Yes
11
PASSTHROUGH
.66
534.6 No
0
1
No
Yes
Yes
12
LAUNDRY
54
'437.4 No
0
1
Yes
Yes
Yes
13
STORAGE CLST
25
202.5 No
0
1
Yes
Yes
Yes
14
BEDROOM 2
140
1414 No
0
1
1
Yes
Yes
Yes
15
CLST 2
16
161.6 No
0
1
Yes
Yes
Yes
16
BATH 2
56
565.6 No
0
1
Yes
Yes
Yes
17
HALL
28
282.8 No
0
1
Yes
Yes
Yes
18
WORKSHOP CLST
14
141.4 No
0
1
No
Yes
Yes
19
WORKSHOP BATH
60
606 No
0
1
No
Yes
Yes
20
WORKSPACE
233
2353.3 No
0
1
Yes
Yes
Yes
6/5/201711:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
M TOILET
loft
0
24 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
M BATH
12 ft
0
72 ft2
__e
1
0
0
3 Slab -On -Grade Edge Insulation
M WIC
9 ft
0
81 ft2
1
0
0
4 Slab -On -Grade Edge Insulation
MASTER BEDRO
14 ft
0
269 ft2
____
1
0
0
5 Slab -On -Grade Edge Insulation
M CLST
1 ft
0
18 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
CAFE
19 ft
0
212 ft2
__e
1
0
0
7 Slab -On -Grade Edge Insulation
FAMILY
28.2 ft
0
265 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
KITCHEN
1 ft
0
218 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
BEDROOM 3
13 ft
0
174 ft2
1
0
0
10SIab-On-Grade Edge Insulation
ENTRY
5 ft
0
45 ft2
____
1
0
0
11SIab-On-Grade Edge Insulation
PASSTHROUGH
1 ft
0
66 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
LAUNDRY
16 ft
0
54 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
STORAGE CLST
5 ft
0
25 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
BEDROOM 2
23 ft
0
140 ft2
____
1
0
0
15SIab-On-Grade Edge Insulation
CLST 2
2 ft
0
16 ft2
1
0
0
16SIab-On-Grade Edge Insulation
BATH 2
15 ft
0
56 ft2
1
0
0
17SIab-On-Grade Edge Insulation
HALL
4 ft
0
28 ft2
____
1
0
0
18SIab-On-Grade Edge Insulation
WORKSHOP CL
1 ft
0
14 ft2
____
1
0
0
19SIab-On-Grade Edge Insulation
WORKSHOP BA
1 ft
0
60 ft2
____
1
0
0
20SIab-On-Grade Edge Insulation
WORKSPACE
16.2 ft
0
233 ft2
____
1
0
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip Metal 2315 ft2
0 ft2
Light
0.6
No 0.9
No
20
26.6
ATTIC
/
V # Type
Ventilation
Vent
Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
2070 ft2
N N
6/5/201.7 11:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 -
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) M TOILET
20
Blown
24 ft2
0.1
Wood
2
Under Attic (Unvented) M BATH
20
Blown
72 ft2
0.1
Wood
3
Under Attic (Unvented) MWIC
20
Blown
81ft2
0.1
Wood
4
Under Attic (Unvented) MASTER BEDRO
20
Blown
269 ft2
0.1
Wood
5
Under Attic (Unvented) M CLST
20
Blown
18 ft2
0.1
Wood
6
Under Attic (Unvented) CAFE
20
Blown
212 ft2
0.1
Wood
7
Under Attic (Unvented) FAMILY
20
Blown
265 ft2
0.1
Wood
8
Under Attic (Unvented) KITCHEN
20
Blown
218 ft2
0.1
Wood
9
Under Attic (Unvented) BEDROOM 3
20
Blown
174 ft2
0.1
Wood
10
Under Attic (Unvented) ENTRY
20
Blown
45 ft2
0.1
Wood
11
Under Attic (Unvented) PASSTHROUGH
20
Blown
66 ft2
0.1
Wood
12
Under Attic (Unvented) LAUNDRY
20
Blown
54 ft2
0.1
Wood
13
Under Attic (Unvented) STORAGE CLST
20
Blown
25 ft2
0.1
Wood
14
Under Attic (Unvented) BEDROOM 2
20
Blown
140 ft2
.0.1
Wood
15
Under Attic (Unvented) CLST 2
20
Blown
16 ft2
0.1
Wood
16
Under Attic (Unvented) BATH 2
20
Blown
56 ft2
0.1
Wood
17
Under Attic (Unvented) HALL
20
Blown
28 ft2
0.1
Wood
18
Under Attic (Unvented) WORKSHOP CL
20
Blown
14 ft2
0.1
Wood
19
Under Attic (Unvented) WORKSHOP BA
20
Blown
60ft2
0.1
Wood
20
Under Attic (Unvented) WORKSPACE
20
Blown
233 ft2
0.1
Wood
WALLS
Adjacent Cavity
Width
Height
Sheathing Framing Solar
Below
Space
1
E
Exterior Concrete Block - Ext InsulM TOILET
4.1
4
0 10
1
40.3 ft2
0
0
0.6
0
2
S
Exterior Concrete Block - Ext InsulM TOILET
4.1
6
0 10
1
60.5 ft2
0
0
0.6
0
_ 3
E
Exterior Concrete Block - Ext Insul M BATH
4.1
12
0 10
1
121.0 ft2
0
0
0.6
0
_ 4
S
Exterior Concrete Block- Ext Insul MWIC
4.1
9
0 10
1
90.8 ft2
0
0
0.6
0
_ 5
S
Exterior Concrete Block - Ext InsdMASTER BE
4.1
14
0 10
1
141.2 ft2
0
0
0.6
0
6
S
Exterior Concrete Block - Ext Insul CAFE
4.1
10
0 10
1
100.8 ft2
0
0
0.6
0
_ 7
W
Exterior Concrete Block - Ext Insul CAFE
4.1
9
0 10
1
90.8 ft2
0
0
0.6
0
8
S
Exterior Concrete Block - Ext Insul FAMILY
4.1
11
0 10
1
110.9 ft2
0
0
0.6
0
9
SW
Exterior Concrete Block - Ext Insul FAMILY
4.1
4
3 10
1
42.9 ft2
0
0
0.6
0
10
W
Exterior Concrete Block - Ext Insul FAMILY
4.1
13
0 10
1
131.1 ft2
0
0
0.6
0
11
N
Exterior Concrete Block - Ext InstSEDROOM 3
4.1
12
0 10
1
121.0 ft2
0
0
0.6
0
12
E
Exterior Concrete Block - Ext InstBEDROOM 3
4.1
1
0 10
1
10.1 ft2
0
0
0.6
0
13
N
Exterior Concrete Block - Ext Insul ENTRY
4.1
5
0 10
1
50.4 ft2
0
0
0.6
0
14
N
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
6
0 8
1
48.5 ft2
0
0
0.6
0
15
E
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
4
0 8
1
32.3 ft2
0
0
0.6
0
16
W
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
6
0 8
1
48.5 ft2
0
0
0.6
0
17
N
Exterior Concrete Block - Ext InsiSTORAGE C
4.1
5
0 8
1
40.4 ft2
0
0
0.6
0
18
N
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
12
0 10
1
121.0 ft2
0
0
0.6
0
19
W
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
11
0 10
1
110.9 ft2
0
0
0.6
0
20
W
Exterior Concrete Block - Ext Insul CLST 2
4.1
2
0 10
1
20.2 ft2
0
0
0.6
0
6/5/2017 11:50 AM EnergyGaugeB USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
It
Ornt
In
Wall T1438Space
21
S
Exterior
Concrete Block - Ext Insul BATH 2
4.1 8
0 10 1
80.7 ft2
0
0 0.6
0
22
W
Exterior
Concrete Block - Ext Insul BATH 2
4.1 7
0 10 1
70.6 ft2
0
0 0.6
0
23
S
Exterior
Concrete Block - Ext Insul HALL
4.1 4
0 10 1
40.3 ft2
0
0 0.6
0
24
N
Exterior
Concrete Block - Ext InsLWORKSPAC
4.1 2
0 10 1
20.2 ft2
0
0 0.6
0
25
NE
Exterior
Concrete Block - Ext InsLWORKSPAC
4.1 4
3 10 1
42.9 ft2
0
0 0.6
0
26
E
Exterior
Concrete Block - Ext InsLWORKSPAC
4.1 10
0 10 1
100.8 ft2
0
0 0.6
0
_ 27
N
Garage
Frame - Wood W ORKSPAC
11 21
8 1
169.8 ft2
0
0 0.600000
0
28
E
Garage
Frame - Wood PASSTHROU
11 17
8 1
137.4 ft2
0
0 0.600000
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade Screening
1
E
3
Vinyl Low-E Single Yes
0.45 0.25
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
2
S
5
Vinyl Low-E Single Yes
0.45 0.25
16.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
S
6
Vinyl Low-E Single Yes
0.45 0.25
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
4
W
7
Vinyl Low-E Single Yes
0.45 0.25
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
5
S
8
Vinyl Low-E Single Yes
0.45 0.25
45.0 ft2
1 ft 0 in
1 ft 4 in
None
None
6
SW 9
Vinyl Low-E Single Yes
0.65 0.3
21.3 ft2
1 ft 0 in
1 ft 4 in
None
None
7
W
10
Vinyl Low-E Single Yes
0.45 0.25
45.0 ft2
1 ft 0 in
1 ft 4 in
None
None
8
N
11
Vinyl Low-E Single Yes
0.45 0.25
10.0 ft2
1 ft 0 in
1 ft 4 in
None
None
9
N
13
Vinyl Low-E Single Yes
0.65 0.3
24.0 ft2
1 ft 0 in
1 ft 4 in
None
None
10
N
14
Vinyl Low-E Single Yes
0.45 0.25
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
11
N
18
Vinyl Low-E Single Yes
0.45 0.25
8.0 ft2
1 ft 0 in
1 ft 4 in
None
None
12
S
21
Vinyl Low-E Single Yes
0.65 0.3
16.7 ft2
1 ft 0 in
1 ft 4 in
None
None
13
W
22
Vinyl Low-E Single Yes
0.45 0.25
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
14
E
26
Vinyl Low-E Single Yes
0.45 0.25
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
441 ft2 441 ft2
38 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000443 2405.3 132.05
248.34
.3234
7
6/5/2017 11:50 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2014
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COPA
27 kBtu/hr
1
sys#1
2
Electric Heat Pump
None
HSPF:13.5
17 kBtu/hr
2
Ductless
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
Split
SEER: 16
30 kBtu/hr
900 cfm
0.8
1
sys#1
2
Central Unit
None
SEER: 33.1
6 kBtu/hr
180 cfm
0.8
2
Ductless
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric Tankless
Garage
0.98 1 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cent # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ftz
DUCTS
V
-- Supply --
— Return --
Air
CFM 25 CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1
Attic 6 140 ftz
Attic
14 ftz Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan
Heatin
Feb [[ jj Mar
Jan Feb [X] Mar
Apr
f Apr f
May Jun Jul
May 4 Jun Jul
]Au4
J1 Auge
SeP f
Oct
Oct
[ ] Nov
[X] Nov
Dec
Dec
Ventin
Jan Feb [[XX]] Mar
[X] Apr [
May [ Jun Jul
E ) Aug
[ Se [X]
Oct
[X] Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78
78
78 80
80
80
80
PM 80
80 80
80 78 78
78
78 78
78
78
78
Cooling (W EH)
AM 78
78 78
78 78 78
78
78 80
80
80
80
PM 80
80 80
80 78 78
78
78 78
78
78
78
Heating (W D)
AM 65
65 65
65 65 65
65
68 68
68
68
68'
PM 68
68 68
68 68 68
68
68 68
68
68
68
Heating (WEH)
AM 65
65 65
65 65 65
65
68 68
68
68
68
PM 68
68 68
68 68 68
68
68 68
68
68
68
6/5/2017 11:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LICAUSI RESIDENCE Builder Name:
Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: STEVE AND MARILYN LICAUSI Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top -or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
6/5/2017 11:50 AM - EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1.
,. .
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows-
Description
a. U-Factor:
Sgl, U=0.45
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.30
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
4905 RIVER PLACE, FORT PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1889.00 ft2
b. Frame - Wood, Adjacent
R=11.0
307.17 ft
1
c. N/A
R=
ftz
3
d. N/A
R=
ftz
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=20.0
2070.00 ftz
2070
b. N/A
R=
ft2
c. N/A
R=
ftz
Area
11. Ducts
R ftz
175.00 ftz
a. Sup: Attic, Ret: Attic, AH: Garage
6 140
62.00 ftz
12. Cooling systems
kBtu/hr
Efficiency
ftz
a. Central Unit
30.0
SEER:16.00
b. Central Unit
6.0
SEER:33.10
ftz
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
27.0 COP:1.00
1.000 ft.
b. Electric Heat Pump
17.0
HSPF:13.50
0.263
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2070.00 ftz
b. N/A R= ftz
c. N/A R= ftz
14. Hot water systems
Cap: 1 gallons
a. Electric
EF: 0.98
b. Conservation features
None
15. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/5/2017 11:50 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1