Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE 6-5-17SCANNED FORM R405-2014 ST L`[lr BY f 011 Wf)" FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LICAUSI RESIDENCE Builder Name: Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: STEVE AND MARILYN LICAUSI Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2196.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1889.00 ft2 b. Frame - Wood, Adjacent 11.0 307.17 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A i ft2 5. Is this a worst case? No 10. Ceiling Types (2070.0 sgft.) Insulation Area a. Roof Deck (Unvented) 1 2070.00 ft2 6. Conditioned floor area above grade (ft2) 2070 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(237.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 140 a. U-Factor: Sgl, 1 175.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 62.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 30.0 SEER:16.00 c. 'U-Factor: N/A ft2 b. Central Unit 6.0 SEER:33.10 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Heat Pump 17.0 HSPF:13.50 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.263 14. Hot water systems 8. Floor Types (2070.0 sgft.) Insulation Area a. Electric Tankless Cap: 1 gallonsEF: a. Slab -On -Grade Edge Insulation 12070.00 ft2 b. Conservation features 0.980 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 63.41 Glass/Floor Area: 0.114 PASS Total Baseline Loads: 71.09 I hereby certify that the plans and specifications covered by Review of the plans and Sr'4T�p this calculation are in compliance with the Florida Energy specifications covered by this O�'Tii.E Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: - this building will be inspected for gip, compliance with Section 553.908 * °' I hereby certify that this b I�g,;alde* sin compliance Florida Statutes. with the Florida Energy G'Otj '1� WE OWNER/AGE T• BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 6/5/2017 11:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: LICAUSI RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2070 Lot # Owner: STEVE AND MARILYN LICAU Total Stories: 1 Block/SubDMsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 MAIN 1837 18263.7 2 WORKSHOP 233 2353.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M TOILET 24 242.4 No 0 1 Yes Yes Yes 2 M BATH 72 727.2 No 0 1 Yes Yes Yes 3 M WIC 81 818.1 No 0 1 Yes Yes Yes 4 MASTER BEDROO 269 2716.9 No 0 1 1 Yes Yes Yes 5 M CLST 18 181.8 No 0 1 No Yes Yes 6 CAFE 212 2141.2 No 0 1 Yes Yes Yes 7 FAMILY 265 2676.5 No 0 1 Yes Yes Yes 8 KITCHEN 218 2201.8 Yes 0 1 No Yes Yes 9 BEDROOM 3 174 1757.4 No 0 1 1 Yes Yes Yes 10 ENTRY 45 454.5 No 0 1 Yes Yes Yes 11 PASSTHROUGH .66 534.6 No 0 1 No Yes Yes 12 LAUNDRY 54 '437.4 No 0 1 Yes Yes Yes 13 STORAGE CLST 25 202.5 No 0 1 Yes Yes Yes 14 BEDROOM 2 140 1414 No 0 1 1 Yes Yes Yes 15 CLST 2 16 161.6 No 0 1 Yes Yes Yes 16 BATH 2 56 565.6 No 0 1 Yes Yes Yes 17 HALL 28 282.8 No 0 1 Yes Yes Yes 18 WORKSHOP CLST 14 141.4 No 0 1 No Yes Yes 19 WORKSHOP BATH 60 606 No 0 1 No Yes Yes 20 WORKSPACE 233 2353.3 No 0 1 Yes Yes Yes 6/5/201711:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M TOILET loft 0 24 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 12 ft 0 72 ft2 __e 1 0 0 3 Slab -On -Grade Edge Insulation M WIC 9 ft 0 81 ft2 1 0 0 4 Slab -On -Grade Edge Insulation MASTER BEDRO 14 ft 0 269 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation M CLST 1 ft 0 18 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation CAFE 19 ft 0 212 ft2 __e 1 0 0 7 Slab -On -Grade Edge Insulation FAMILY 28.2 ft 0 265 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 218 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation BEDROOM 3 13 ft 0 174 ft2 1 0 0 10SIab-On-Grade Edge Insulation ENTRY 5 ft 0 45 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation PASSTHROUGH 1 ft 0 66 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY 16 ft 0 54 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation STORAGE CLST 5 ft 0 25 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2 23 ft 0 140 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation CLST 2 2 ft 0 16 ft2 1 0 0 16SIab-On-Grade Edge Insulation BATH 2 15 ft 0 56 ft2 1 0 0 17SIab-On-Grade Edge Insulation HALL 4 ft 0 28 ft2 ____ 1 0 0 18SIab-On-Grade Edge Insulation WORKSHOP CL 1 ft 0 14 ft2 ____ 1 0 0 19SIab-On-Grade Edge Insulation WORKSHOP BA 1 ft 0 60 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation WORKSPACE 16.2 ft 0 233 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2315 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2070 ft2 N N 6/5/201.7 11:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 - FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) M TOILET 20 Blown 24 ft2 0.1 Wood 2 Under Attic (Unvented) M BATH 20 Blown 72 ft2 0.1 Wood 3 Under Attic (Unvented) MWIC 20 Blown 81ft2 0.1 Wood 4 Under Attic (Unvented) MASTER BEDRO 20 Blown 269 ft2 0.1 Wood 5 Under Attic (Unvented) M CLST 20 Blown 18 ft2 0.1 Wood 6 Under Attic (Unvented) CAFE 20 Blown 212 ft2 0.1 Wood 7 Under Attic (Unvented) FAMILY 20 Blown 265 ft2 0.1 Wood 8 Under Attic (Unvented) KITCHEN 20 Blown 218 ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 3 20 Blown 174 ft2 0.1 Wood 10 Under Attic (Unvented) ENTRY 20 Blown 45 ft2 0.1 Wood 11 Under Attic (Unvented) PASSTHROUGH 20 Blown 66 ft2 0.1 Wood 12 Under Attic (Unvented) LAUNDRY 20 Blown 54 ft2 0.1 Wood 13 Under Attic (Unvented) STORAGE CLST 20 Blown 25 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 2 20 Blown 140 ft2 .0.1 Wood 15 Under Attic (Unvented) CLST 2 20 Blown 16 ft2 0.1 Wood 16 Under Attic (Unvented) BATH 2 20 Blown 56 ft2 0.1 Wood 17 Under Attic (Unvented) HALL 20 Blown 28 ft2 0.1 Wood 18 Under Attic (Unvented) WORKSHOP CL 20 Blown 14 ft2 0.1 Wood 19 Under Attic (Unvented) WORKSHOP BA 20 Blown 60ft2 0.1 Wood 20 Under Attic (Unvented) WORKSPACE 20 Blown 233 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block - Ext InsulM TOILET 4.1 4 0 10 1 40.3 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext InsulM TOILET 4.1 6 0 10 1 60.5 ft2 0 0 0.6 0 _ 3 E Exterior Concrete Block - Ext Insul M BATH 4.1 12 0 10 1 121.0 ft2 0 0 0.6 0 _ 4 S Exterior Concrete Block- Ext Insul MWIC 4.1 9 0 10 1 90.8 ft2 0 0 0.6 0 _ 5 S Exterior Concrete Block - Ext InsdMASTER BE 4.1 14 0 10 1 141.2 ft2 0 0 0.6 0 6 S Exterior Concrete Block - Ext Insul CAFE 4.1 10 0 10 1 100.8 ft2 0 0 0.6 0 _ 7 W Exterior Concrete Block - Ext Insul CAFE 4.1 9 0 10 1 90.8 ft2 0 0 0.6 0 8 S Exterior Concrete Block - Ext Insul FAMILY 4.1 11 0 10 1 110.9 ft2 0 0 0.6 0 9 SW Exterior Concrete Block - Ext Insul FAMILY 4.1 4 3 10 1 42.9 ft2 0 0 0.6 0 10 W Exterior Concrete Block - Ext Insul FAMILY 4.1 13 0 10 1 131.1 ft2 0 0 0.6 0 11 N Exterior Concrete Block - Ext InstSEDROOM 3 4.1 12 0 10 1 121.0 ft2 0 0 0.6 0 12 E Exterior Concrete Block - Ext InstBEDROOM 3 4.1 1 0 10 1 10.1 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Ext Insul ENTRY 4.1 5 0 10 1 50.4 ft2 0 0 0.6 0 14 N Exterior Concrete Block - Ext InsuILAUNDRY 4.1 6 0 8 1 48.5 ft2 0 0 0.6 0 15 E Exterior Concrete Block - Ext InsuILAUNDRY 4.1 4 0 8 1 32.3 ft2 0 0 0.6 0 16 W Exterior Concrete Block - Ext InsuILAUNDRY 4.1 6 0 8 1 48.5 ft2 0 0 0.6 0 17 N Exterior Concrete Block - Ext InsiSTORAGE C 4.1 5 0 8 1 40.4 ft2 0 0 0.6 0 18 N Exterior Concrete Block - Ext InstBEDROOM 2 4.1 12 0 10 1 121.0 ft2 0 0 0.6 0 19 W Exterior Concrete Block - Ext InstBEDROOM 2 4.1 11 0 10 1 110.9 ft2 0 0 0.6 0 20 W Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 10 1 20.2 ft2 0 0 0.6 0 6/5/2017 11:50 AM EnergyGaugeB USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below It Ornt In Wall T1438Space 21 S Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 10 1 80.7 ft2 0 0 0.6 0 22 W Exterior Concrete Block - Ext Insul BATH 2 4.1 7 0 10 1 70.6 ft2 0 0 0.6 0 23 S Exterior Concrete Block - Ext Insul HALL 4.1 4 0 10 1 40.3 ft2 0 0 0.6 0 24 N Exterior Concrete Block - Ext InsLWORKSPAC 4.1 2 0 10 1 20.2 ft2 0 0 0.6 0 25 NE Exterior Concrete Block - Ext InsLWORKSPAC 4.1 4 3 10 1 42.9 ft2 0 0 0.6 0 26 E Exterior Concrete Block - Ext InsLWORKSPAC 4.1 10 0 10 1 100.8 ft2 0 0 0.6 0 _ 27 N Garage Frame - Wood W ORKSPAC 11 21 8 1 169.8 ft2 0 0 0.600000 0 28 E Garage Frame - Wood PASSTHROU 11 17 8 1 137.4 ft2 0 0 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 3 Vinyl Low-E Single Yes 0.45 0.25 6.0 ft2 1 ft 0 in 1 ft 4 in None None 2 S 5 Vinyl Low-E Single Yes 0.45 0.25 16.0 ft2 1 ft 0 in 1 ft 4 in None None 3 S 6 Vinyl Low-E Single Yes 0.45 0.25 12.0 ft2 1 ft 0 in 1 ft 4 in None None 4 W 7 Vinyl Low-E Single Yes 0.45 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None None 5 S 8 Vinyl Low-E Single Yes 0.45 0.25 45.0 ft2 1 ft 0 in 1 ft 4 in None None 6 SW 9 Vinyl Low-E Single Yes 0.65 0.3 21.3 ft2 1 ft 0 in 1 ft 4 in None None 7 W 10 Vinyl Low-E Single Yes 0.45 0.25 45.0 ft2 1 ft 0 in 1 ft 4 in None None 8 N 11 Vinyl Low-E Single Yes 0.45 0.25 10.0 ft2 1 ft 0 in 1 ft 4 in None None 9 N 13 Vinyl Low-E Single Yes 0.65 0.3 24.0 ft2 1 ft 0 in 1 ft 4 in None None 10 N 14 Vinyl Low-E Single Yes 0.45 0.25 6.0 ft2 1 ft 0 in 1 ft 4 in None None 11 N 18 Vinyl Low-E Single Yes 0.45 0.25 8.0 ft2 1 ft 0 in 1 ft 4 in None None 12 S 21 Vinyl Low-E Single Yes 0.65 0.3 16.7 ft2 1 ft 0 in 1 ft 4 in None None 13 W 22 Vinyl Low-E Single Yes 0.45 0.25 6.0 ft2 1 ft 0 in 1 ft 4 in None None 14 E 26 Vinyl Low-E Single Yes 0.45 0.25 6.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ft2 441 ft2 38 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000443 2405.3 132.05 248.34 .3234 7 6/5/2017 11:50 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 27 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:13.5 17 kBtu/hr 2 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 30 kBtu/hr 900 cfm 0.8 1 sys#1 2 Central Unit None SEER: 33.1 6 kBtu/hr 180 cfm 0.8 2 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.98 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS V -- Supply -- — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ftz Attic 14 ftz Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Heatin Feb [[ jj Mar Jan Feb [X] Mar Apr f Apr f May Jun Jul May 4 Jun Jul ]Au4 J1 Auge SeP f Oct Oct [ ] Nov [X] Nov Dec Dec Ventin Jan Feb [[XX]] Mar [X] Apr [ May [ Jun Jul E ) Aug [ Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68' PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/5/2017 11:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LICAUSI RESIDENCE Builder Name: Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: STEVE AND MARILYN LICAUSI Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top -or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/5/2017 11:50 AM - EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1. ,. . FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Sgl, U=0.45 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.30 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 4905 RIVER PLACE, FORT PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1889.00 ft2 b. Frame - Wood, Adjacent R=11.0 307.17 ft 1 c. N/A R= ftz 3 d. N/A R= ftz 10. Ceiling Types Insulation Area No a. Roof Deck (Unvented) R=20.0 2070.00 ftz 2070 b. N/A R= ft2 c. N/A R= ftz Area 11. Ducts R ftz 175.00 ftz a. Sup: Attic, Ret: Attic, AH: Garage 6 140 62.00 ftz 12. Cooling systems kBtu/hr Efficiency ftz a. Central Unit 30.0 SEER:16.00 b. Central Unit 6.0 SEER:33.10 ftz 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 27.0 COP:1.00 1.000 ft. b. Electric Heat Pump 17.0 HSPF:13.50 0.263 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2070.00 ftz b. N/A R= ftz c. N/A R= ftz 14. Hot water systems Cap: 1 gallons a. Electric EF: 0.98 b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/5/2017 11:50 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1